127 resultados para Validation of measures


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The updated Vienna Prediction Model for estimating recurrence risk after an unprovoked venous thromboembolism (VTE) has been developed to identify individuals at low risk for VTE recurrence in whom anticoagulation (AC) therapy may be stopped after 3 months. We externally validated the accuracy of the model to predict recurrent VTE in a prospective multicenter cohort of 156 patients aged ≥65 years with acute symptomatic unprovoked VTE who had received 3 to 12 months of AC. Patients with a predicted 12-month risk within the lowest quartile based on the updated Vienna Prediction Model were classified as low risk. The risk of recurrent VTE did not differ between low- vs higher-risk patients at 12 months (13% vs 10%; P = .77) and 24 months (15% vs 17%; P = 1.0). The area under the receiver operating characteristic curve for predicting VTE recurrence was 0.39 (95% confidence interval [CI], 0.25-0.52) at 12 months and 0.43 (95% CI, 0.31-0.54) at 24 months. In conclusion, in elderly patients with unprovoked VTE who have stopped AC, the updated Vienna Prediction Model does not discriminate between patients who develop recurrent VTE and those who do not. This study was registered at www.clinicaltrials.gov as #NCT00973596.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The Prestroke Independence, Sex, Age, National Institutes of Health Stroke Scale (ISAN) score was developed recently for predicting stroke-associated pneumonia (SAP), one of the most common complications after stroke. The aim of the present study was to externally validate the ISAN score. METHODS: Data included in the Athens Stroke Registry between June 1992 and December 2011 were used for this analysis. Inclusion criteria were the availability of all ISAN score variables (prestroke independence, sex, age, National Institutes of Health Stroke Scale score). Receiver operating characteristic curves and linear regression analyses were used to determine the discriminatory power of the score and to assess the correlation between actual and predicted pneumonia in the study population. Separate analyses were performed for patients with acute ischemic stroke (AIS) and intracerebral hemorrhage (ICH). RESULTS: The analysis included 3204 patients (AIS: 2732, ICH: 472). The ISAN score demonstrated excellent discrimination in patients with AIS (area under the curve [AUC]: .83 [95% confidence interval {CI}: .81-.85]). In the ICH group, the score was less effective (AUC: .69 [95% CI: .63-.74]). Higher-risk groups of ISAN score were associated with an increased relative risk of SAP; risk increase was more prominent in the AIS population. Predicted pneumonia correlated very well with actual pneumonia (AIS group: R(2) = .885; β-coefficient = .941, P < .001; ICH group: R(2) = .880, β-coefficient = .938, P < .001). CONCLUSIONS: In our external validation in the Athens Stroke Registry cohort, the ISAN score predicted SAP very accurately in AIS patients and demonstrated good discriminatory power in the ICH group. Further validation and assessment of clinical usefulness would strengthen the score's utility further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To develop and test the Parental PELICAN Questionnaire, an instrument to retrospectively assess parental experiences and needs during their child's end-of-life care. BACKGROUND: To offer appropriate care for dying children, healthcare professionals need to understand the illness experience from the family perspective. A questionnaire specific to the end-of-life experiences and needs of parents losing a child is needed to evaluate the perceived quality of paediatric end-of-life care. DESIGN: This is an instrument development study applying mixed methods based on recommendations for questionnaire design and validation. METHOD: The Parental PELICAN Questionnaire was developed in four phases between August 2012-March 2014: phase 1: item generation; phase 2: validity testing; phase 3: translation; phase 4: pilot testing. Psychometric properties were assessed after applying the Parental PELICAN Questionnaire in a sample of 224 bereaved parents in April 2014. Validity testing covered the evidence based on tests of content, internal structure and relations to other variables. RESULTS: The Parental PELICAN Questionnaire consists of approximately 90 items in four slightly different versions accounting for particularities of the four diagnostic groups. The questionnaire's items were structured according to six quality domains described in the literature. Evidence of initial validity and reliability could be demonstrated with the involvement of healthcare professionals and bereaved parents. CONCLUSION: The Parental PELICAN Questionnaire holds promise as a measure to assess parental experiences and needs and is applicable to a broad range of paediatric specialties and settings. Future validation is needed to evaluate its suitability in different cultures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was the validation of a brief form of the Perceived Neighborhood Social Cohesion questionnaire using data from 5065 men from the "Cohort Study on Substance-Use Risk Factors." A 9-item scale covering three factors was proposed. Excellent indices of internal consistency were measured (α = .93). The confirmatory factor analyses resulted in acceptable fit indices supporting measurement invariance across French and German forms. Significant correlations were found between the brief form of the Perceived Neighborhood Social Cohesion questionnaire, and satisfaction and self-reported health, providing evidence of the concurrent validity of the scale. Perceived neighborhood social cohesion, and depression and suicide attempts were negatively associated, sustaining the protective effect of perceived social cohesion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have designed and validated a novel generic platform for production of tetravalent IgG1-like chimeric bispecific Abs. The VH-CH1-hinge domains of mAb2 are fused through a peptidic linker to the N terminus of mAb1 H chain, and paired mutations at the CH1-CL interface mAb1 are introduced that force the correct pairing of the two different free L chains. Two different sets of these CH1-CL interface mutations, called CR3 and MUT4, were designed and tested, and prototypic bispecific Abs directed against CD5 and HLA-DR were produced (CD5xDR). Two different hinge sequences between mAb1 and mAb2 were also tested in the CD5xDR-CR3 or -MUT4 background, leading to bispecific Ab (BsAbs) with a more rigid or flexible structure. All four Abs produced bound with good specificity and affinity to CD5 and HLA-DR present either on the same target or on different cells. Indeed, the BsAbs were able to efficiently redirect killing of HLA-DR(+) leukemic cells by human CD5(+) cytokine-induced killer T cells. Finally, all BsAbs had a functional Fc, as shown by their capacity to activate human complement and NK cells and to mediate phagocytosis. CD5xDR-CR3 was chosen as the best format because it had overall the highest functional activity and was very stable in vitro in both neutral buffer and in serum. In vivo, CD5xDR-CR3 was shown to have significant therapeutic activity in a xenograft model of human leukemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. METHODS: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. RESULTS: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). CONCLUSION: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. ADVANCES IN KNOWLEDGE: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.