218 resultados para SYNCHROTRON RADIATION SOURCES
Resumo:
Aim: When planning SIRT using 90Y microspheres, the partition model is used to refine the activity calculated by the body surface area (BSA) method to potentially improve the safety and efficacy of treatment. For this partition model dosimetry, accurate determination of mean tumor-to-normal liver ratio (TNR) is critical since it directly impacts absorbed dose estimates. This work aimed at developing and assessing a reliable methodology for the calculation of 99mTc-MAA SPECT/CT-derived TNR ratios based on phantom studies. Materials and methods: IQ NEMA (6 hot spheres) and Kyoto liver phantoms with different hot/background activity concentration ratios were imaged on a SPECT/CT (GE Infinia Hawkeye 4). For each reconstruction with the IQ phantom, TNR quantification was assessed in terms of relative recovery coefficients (RC) and image noise was evaluated in terms of coefficient of variation (COV) in the filled background. RCs were compared using OSEM with Hann, Butterworth and Gaussian filters, as well as FBP reconstruction algorithms. Regarding OSEM, RCs were assessed by varying different parameters independently, such as the number of iterations (i) and subsets (s) and the cut-off frequency of the filter (fc). The influence of the attenuation and diffusion corrections was also investigated. Furthermore, both 2D-ROIs and 3D-VOIs contouring were compared. For this purpose, dedicated Matlab© routines were developed in-house for automatic 2D-ROI/3D-VOI determination to reduce intra-user and intra-slice variability. Best reconstruction parameters and RCs obtained with the IQ phantom were used to recover corrected TNR in case of the Kyoto phantom for arbitrary hot-lesion size. In addition, we computed TNR volume histograms to better assess uptake heterogeneityResults: The highest RCs were obtained with OSEM (i=2, s=10) coupled with the Butterworth filter (fc=0.8). Indeed, we observed a global 20% RC improvement over other OSEM settings and a 50% increase as compared to the best FBP reconstruction. In any case, both attenuation and diffusion corrections must be applied, thus improving RC while preserving good image noise (COV<10%). Both 2D-ROI and 3D-VOI analysis lead to similar results. Nevertheless, we recommend using 3D-VOI since tumor uptake regions are intrinsically 3D. RC-corrected TNR values lie within 17% around the true value, substantially improving the evaluation of small volume (<15 mL) regions. Conclusions: This study reports the multi-parameter optimization of 99mTc MAA SPECT/CT images reconstruction in planning 90Y dosimetry for SIRT. In phantoms, accurate quantification of TNR was obtained using OSEM coupled with Butterworth and RC correction.
Resumo:
OBJECTIVE: This article analyses the influence of treatment duration on survival in patients with invasive carcinoma of the cervix treated by radical radiation therapy. METHOD: Three hundred and sixty patients with FIGO stage IB-IIIB carcinoma of the cervix were treated in Lausanne (Switzerland) with external radiation and brachytherapy as first line therapy. Median therapy duration was 45 days. Patients were classified according to the duration of the therapies, taking 60 days (the 75th percentile) as an arbitrary cut-off. RESULTS: The 5-year survival was 61% (S.E. = 3%) for the therapy duration group of less than 60 days and 53% (S.E. = 7%) for the group of more than 60 days. In terms of univariate hazard ratio (HR), the relative difference between the two groups corresponds to a 50% increase of deaths (HR = 1.53, 95% CI = 1.03-2.28) for the longer therapy duration group (P = 0.044). In a multivariate analysis, the magnitude of estimated relative hazards for the longer therapies are confirmed though significance was reduced (HR = 1.52, 95% CI = 0.94-2.45, P = 0.084). CONCLUSION: These findings suggest that short treatment duration is a factor associated with longer survival in carcinoma of the cervix.
Resumo:
Radiotherapy is successfully used to treat cancer. Emerging evidence, however, indicates that recurrences after radiotherapy are associated with increased local invasion, metastatic spreading and poor prognosis. Radiation-induced modifications of the tumor microenvironment have been proposed to contribute to increased aggressive tumor behavior, an effect also referred to as tumor bed effect, but the putative mechanisms involved have remained largely elusive. We have recently demonstrated that irradiation of the prospective tumor stroma impairs de novo angiogenesis through sustained inhibition of proliferation, migration and sprouting of endothelial cells. Experimental tumors growing within a pre-irradiated field have reduced tumor angiogenesis and tumor growth, increased hypoxia, necrosis, local invasion and distant metastasis. Mechanisms of progression involve adaptation of tumor cells to local hypoxic conditions as well as selection of cells with invasive and metastatic capacities. The matricellular protein CYR61 and integrin αVβ5 emerged as molecules that cooperate to mediate lung metastasis. Cilengitide, a small molecular inhibitor of αV integrins prevented lung metastasis formation. These results represent a conceptual advance to the understanding of the tumor bed effect and indicate that αV integrin inhibition might be a potential therapeutic approach for preventing metastasis in patients at risk for post-radiation recurrences.
Resumo:
BACKGROUND: To assess functional results, complications, and success of larynx preservation in patients with recurrent squamous cell carcinoma after radiotherapy. METHODS: From a database of 40 patients who underwent supracricoid partial laryngectomy (SCPL) with cricohyoidoepiglottopexy (CHEP) from June 2001 to April 2006, eight patients were treated previously with radiotherapy due to squamous cell carcinoma of the glottic region and were treated for recurrence at the site of the primary cancer. RESULTS: SCPL with CHEP was performed in six men and two women with a mean age of 67 years due to recurrence and/or persistence at a mean time of 30 months postradiotherapy (in case #8 after concomitant chemoradiotherapy). Bilateral neck dissection at levels II-V was performed in six patients. Only case #8 presented metastasis in one node. In case #5, Delphian node was positive. It was possible to preserve both arytenoids in five cases. Definitive surgical margins were negative. Complications were encountered in seven patients. Follow-up was on average 44 months (range: 20-67 months). Organ preservation in this series was 75%, and local control was 87%. Overall 5-year survival was 50%. CONCLUSIONS: In selected patient with persistence and/or recurrence after radiotherapy due to cancer of the larynx, SCPL with CHEP seems to be feasible with acceptable local control and toxicity. Complications may occur as in previously non-irradiated patients. These complications must be treated conservatively to avoid altering laryngeal function.
Resumo:
BACKGROUND: Sorafenib (Sb) is a multiple kinase inhibitor targeting both tumour cell proliferation and angiogenesis that may further act as a potent radiosensitizer by arresting cells in the most radiosensitive cell cycle phase. This phase I open-label, noncontrolled dose escalation study was performed to determine the safety and maximum tolerated dose (MTD) of Sb in combination with radiation therapy (RT) and temozolomide (TMZ) in 17 patients with newly diagnosed high-grade glioma. METHODS: Patients were treated with RT (60 Gy in 2 Gy fractions) combined with TMZ 75 mg m(-2) daily, and Sb administered at three dose levels (200 mg daily, 200 mg BID, and 400 mg BID) starting on day 8 of RT. Thirty days after the end of RT, patients received monthly TMZ (150-200 mg m(-2) D1-5/28) and Sb (400 mg BID). Pharmacokinetic (PK) analyses were performed on day 8 (TMZ) and on day 21 (TMZ&Sb) (Clinicaltrials ID: NCT00884416). RESULTS: The MTD of Sb was established at 200 mg BID. Dose-limiting toxicities included thrombocytopenia (two patients), diarrhoea (one patient) and hypercholesterolaemia (one patient). Sb administration did not affect the mean area under the curve(0-24) and mean Cmax of TMZ and its metabolite 5-amino-imidazole-4-carboxamide (AIC). Tmax of both TMZ and AIC was delayed from 0.75 (TMZ alone) to 1.5 h (combined TMZ/Sb). The median progression-free survival was 7.9 months (95% confidence interval (CI): 5.4-14.55), and the median overall survival was 17.8 months (95% CI: 14.7-25.6). CONCLUSIONS: Although Sb can be combined with RT and TMZ, significant side effects and moderate outcome results do not support further clinical development in malignant gliomas. The robust PK data of the TMZ/Sb combination could be useful in other cancer settings.
Resumo:
BACKGROUND: The purpose of this study was to determine the long-term outcomes of patients undergoing endocavitary contact radiation therapy (ECR) for stage I rectal cancer. METHODS: A database of patients treated with ECR for biopsy-proven rectal adenocarcinoma from July 1986 to June 2006 was reviewed retrospectively. Only patients with primary, non-metastatic, ultrasonographically staged T1 N0 and T2 N0 cancer who had no adjuvant treatment were included. Patients received a median of 90 (range 60-190) Gy contact radiation, delivered transanally by a 50-kV X-ray tube in two to five fractions. RESULTS: Of 149 patients, 77 (40 T1, 37 T2) met the inclusion criteria. Median age was 74 (range 38-104) years, and median follow-up 69 (range 10-219) months. ECR failed in 21 patients (27 per cent) (persistent disease, four; recurrence, 17), of whom ten remained disease free after salvage therapy. The estimated 5-year disease-free survival rate was 74 (95 per cent confidence interval 63 to 83) per cent after ECR alone, and 87 (76 to 93) per cent when survival after salvage therapy for recurrence was included. CONCLUSION: ECR is a minimally invasive treatment option for early-stage rectal cancer. However, similar to other local therapies, ECR has a worse oncological outcome than radical surgery.
Resumo:
OBJECTIVE: Examination of the rate of grade III or grade IV radiation dermatitis during treatment of head and neck cancer (HNC) with radiotherapy (RT) and concurrent cetuximab in EORTC centres. MATERIALS AND METHOD: A questionnaire was sent to all members of the EORTC Radiation Oncology Group and Head and Neck Group (111 institutions) to evaluate the widespread use of cetuximab and radiotherapy in HNC and to estimate the frequency of grades III and IV skin reactions in the radiation portals associated with this protocol. Co-morbidities, RT schedules and co-medications were also recorded. RESULTS: We received responses from 28 institutions in 11 countries. A total of 125 HNC patients from 15 institutions were treated with cetuximab and concurrent RT. Information about the skin reactions was available from 71 patients. Of these 36 had no grade III/IV adverse effects in the RT field, 15 had a grade III and 20 had grade IV radiation dermatitis. No detectable relation of grades III and IV radiation dermatitis with co-morbidities such as liver insufficiency or renal dysfunction was found. CONCLUSION: According to the results of the questionnaire, grade III/IV radiation dermatitis is observed in 49% of HNC patients treated with cetuximab and concurrent RT. A systematic clinical monitoring of cutaneous side effects during RT plus cetuximab is advised to ensure the safety of this protocol.
Resumo:
PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.
Resumo:
False identity documents constitute a potential powerful source of forensic intelligence because they are essential elements of transnational crime and provide cover for organized crime. In previous work, a systematic profiling method using false documents' visual features has been built within a forensic intelligence model. In the current study, the comparison process and metrics lying at the heart of this profiling method are described and evaluated. This evaluation takes advantage of 347 false identity documents of four different types seized in two countries whose sources were known to be common or different (following police investigations and dismantling of counterfeit factories). Intra-source and inter-sources variations were evaluated through the computation of more than 7500 similarity scores. The profiling method could thus be validated and its performance assessed using two complementary approaches to measuring type I and type II error rates: a binary classification and the computation of likelihood ratios. Very low error rates were measured across the four document types, demonstrating the validity and robustness of the method to link documents to a common source or to differentiate them. These results pave the way for an operational implementation of a systematic profiling process integrated in a developed forensic intelligence model.