210 resultados para Rectum prosthesis
Resumo:
OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.
Resumo:
Avec 95% de bons résultats à 10 ans, on peut considérer aujourd'hui que l'arthroplastie totale du genou est un traitement fiable des gonarthroses chez des patients âgés à demande fonctionnelle raisonnable. Les quatre complications potentielles principales après la mise en place d'une prothèse totale du genou sont le descellement aseptique, l'infection, le manque de flexion et les douleurs persistantes. En cas de problème avec une prothèse totale du genou, il faut toujours exclure la présence d'une infection avant d'envisager une autre raison. Les innovations actuelles en arthroplastie du genou doivent viser à améliorer les résultats chez les patients jeunes et actifs i.e. tant au niveau de la conception des nouveaux implants, voire des matériaux plus résistants, que des techniques chirurgicales elles-mêmes. Total knee arthroplasty: current advances and results With a 95% success rate at 10 years, total knee arthroplasty can be regarded today as a reliable way of treating knee osteoarthritis in elderly patients with reasonable functional demands. The four main potential complications after placing of a total knee prosthesis are aseptic loosening, infection, lack of flexion and persistent pain. If a problem arises with a total knee prosthesis, infection must always be ruled out before considering other causes. Current innovations in knee arthroplasty should be aimed at improving results in young and active patients, i.e. in regard to both the design of new implants, or tougher materials, and to the surgical techniques themselves.
Resumo:
BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.
Resumo:
The usefulness and limitations of the carcinoembryonic antigen (C.E.A.) radioimmunoassay for the evaluation of tumour resection and for the detection of tumour relapse were studied in patients with large-bowel carcinoma. The level of plasma-C.E.A. was determined before any treatment in a group of 101 patients with histologically proven adenocarcinoma of the colon and rectum. 71% of all patients and 63% of cases with localised tumour (Dukes A and B) had a preoperative C.E.A. value of 5 ng. per ml. or higher. This limit was reached by only 1 of 90 apparently healthy, non-smoking blood-donors. Among 45 patients for whom a complete tumour resection was reported, all patients except 5 showed a drop of C.E.A. to normal values after surgery. The 5 patients whose C.E.A. did not fall to below 5 ng. per ml. showed a subsequent rise in C.E.A. level and were all found later to have a tumour relapse. The results indicate that an incomplete drop of circulating C.E.A. level one month after surgery has a bad prognostic significance. 22 of these patients were followed up by repeated C.E.A. radioimmunoassay for several months after surgery. 8 showed a progressive increase in C.E.A. levels preceding clinical diagnosis of tumour relapse by two to ten months. 6 other patients showed a moderate increase in C.E.A. levels, suggesting a tumour relapse not yet clinically detectable. The remaining 8 patients showed no increase in C.E.A. level above 5 ng. per ml. and no clinical symptoms of relapse. The results demonstrate that relapses of colon and rectum carcinoma can be detected by increased C.E.A. levels months before the appearance of any clinical evidence.
Resumo:
L'évaluation des résultats des arthroplasties totales du genou demande une évaluation du geste thérapeutique ou clinique, mais doit également tenir compte de l'impact de ce geste sur l'état de santé global du patient (somatique, psychologique, social) et intégrer son degré de satisfaction. La complexité croissante des instruments de mesure du suivi a de quoi décourager le chirurgien praticien déjà surchargé par son activité clinique quotidienne. L'apparition des scores, des études prospectives et des analyses statistiques, telles les courbes de survie, ont certainement permis une appréciation plus objective de nos résultats, tout en accroissant nos connaissances et en améliorant notre pratique quotidienne. La question aujourd'hui n'est plus de savoir si un suivi clinique de nos patients est utile, mais plutôt de choisir les bons instruments et de définir les buts de l'analyse tout en cherchant comment implanter cette démarche de manière réaliste dans nos pratiques. Les scores classiques, aussi imparfaits soient-ils, restent pour l'instant utiles. Largement diffusés à travers le monde, appliqués de manière prospective, ces outils de suivi orientés vers la clinique et la radiologie sont le fondement du suivi prospectif des implants. Au quotidien, ils permettent un suivi en temps réel des implants d'un service ou d'une institution. Cependant, leur faiblesse intrinsèque résidant dans l'inaptitude à saisir le point de vue du patient, il semble inéluctable d'y adjoindre des instruments psychométriques. Dans l'avenir, la recherche devrait se concentrer vers le développement d'outils adaptés, capables de cerner avec une plus grande précision l'attente des patients et de technologies accessibles à chaque praticien pour mesurer objectivement les capacités fonctionnelles de leurs patients avec plus d'acuité. Le développement de systèmes permettant une évaluation objective de la fonction quotidienne du patient revêt un intérêt tout particulier. Parallèlement, un effort doit être fait au niveau des sociétés spécialisées nationales et internationales pour harmoniser leurs protocoles de suivi.
Resumo:
Elbow arthroplasty is increasingly performed in patients with rheumatic and post-traumatic arthritis. Data on elbow periprosthetic joint infection (PJI) are limited. We investigated the characteristics and outcome of elbow PJI in a 14-year cohort of total elbow arthroplasties in a single centre. Elbow prosthesis, which were implanted between 1994 and 2007 at Schulthess Clinic in Zurich, were retrospectively screened for infection. PJI was defined as periprosthetic purulence, the presence of sinus tract or microbial growth. A Kaplan-Meier survival method and Cox proportional hazard analysis were performed. Of 358 elbow prostheses, PJI was identified in 27 (7.5%). The median patient age (range) was 61 (39-82) years; 63% were females. Seventeen patients (63%) had a rheumatic disorder and ten (37%) had osteoarthritis. Debridement and implant retention was performed in 78%, followed by exchange or removal of the prosthesis (15%) or no surgery (7%).The relapse-free survival (95% CI) was 79% (63-95%) after 1 year and 65% (45-85%) after 2 years. The outcome after 2 years was significantly better when patients were treated according to the algorithm compared to patients who were not (100% vs. 33%, p <0.05). In 21 patients treated with debridement and retention, the cure rate was also higher when the algorithm was followed (100% vs. 11%, p <0.05). The findings of the present study suggest that the treatment algorithm developed for hip and knee PJI can be applied to elbow PJI. With proper patient selection and antimicrobial therapy, debridement and retention of the elbow prosthesis is associated with good treatment outcome.
Resumo:
For successful treatment of prosthetic joint infection, the identification of the infecting microorganism is crucial. Cultures of synovial fluid and intraoperative periprosthetic tissue represent the standard method for diagnosing prosthetic joint infection. Rapid and accurate diagnostic tools which can detect a broad range of causing microorganisms and their antimicrobial resistance are increasingly needed. With newer diagnostic techniques, such as sonication of removed implants, microcalorimetry, molecular methods and mass spectrometry, the sensitivity has been significantly increased. In this article, we describe the conventional and newer diagnostic techniques with their advantages and potential future applications.
Resumo:
Stents have a long history in traditional valve surgery as both, porcine biological valves as well as pericardial valves are mounted on stents prior to implantation. Recently stent-mounted biological devices have been compressed up to the point, where they can be passed through a catheter. Various routes can be distinguished for implantation: open access, the trans-vascular route in antegrade or retrograde fashion, as well as direct trans-apical or trans-atrial access. Direct access has the potentialforvideo-endoscopic valve replacement. In theory, as well as in the experimental setting, valved stents have been implanted in tricuspid and caval position respectively, as well as in pulmonary, mitral and aortic locations. The largest clinical experience has been achieved in pulmonary position whereas current efforts target the aortic position.
Resumo:
BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.
Resumo:
Introduction: Several methods have already been proposed to improve the mobility of reversed prostheses (lateral or inferior displacement, increase of the glenosphere size). However, the effect of these design changes have only been evaluated on the maximal range of motion and were not related to activities of daily living (ADL). Our aim was thus to measure the effect of these design changes and to relate it to 4 typical ADL. Methods: CT data were used to reconstruct a accurate geometric model of the scapula and humerus. The Aequalis reversed prosthesis (Tornier) was used. The mobility of a healthy shoulder was compared to the mobility of 4 different reversed designs: 36 and 42 mm glenospheres diameters, inferior (4 mm) and lateral (3.2 mm) glenospheres displacements. The complete mobility map of the prosthesis was compared to kinematics measurement on healthy subjects for 4 ADL: 1) hand to contra lateral shoulder, 2) hand to mouth, 3) combing hair, 4) hand to back pocket. The results are presented as percentage of the allowed movement of the prosthestic shouder relative to the healthy shoulder, considered as the control group. Results: None of the tested designs allowed to recover a full mobility. The differences of allowed range of motion among each prosthetic designs appeared mainly in two of the 4 movements: hand to back pocket and hand to contra lateral shoulder. For the hand to back pocket, the 36 had the lowest mobility range, particularly for the last third of the movement. The 42 appeared to be a good compromise for all ADL activities. Conclusion: Reverse shoulder prostheses does not allow to recover a full range of motion compared to healthy shoulders, even for ADL. The present study allowed to obtain a complete 3D mobility map for several glenosphere positions and sizes, and to relate it to typical ADL. We mainly observed an improved mobility with inferior displacement and increased glenosphere size. We would suggest to use larger glenosphere, whenever it is possible.
Resumo:
A 56-year-old patient admitted to hospital for the suspicion of an acute coronary syndrome underwent coronary angiography without detection of significant lesions. Seven days later the echocardiography showed acute severe aortic valve insufficiency. Intraoperatively we found a perforated leaflet probably due to lesion during transcatheter procedure.
Resumo:
In locally advanced cervical cancer, (18)F-fluorodeoxyglucose (FDG) positron emission tomography - computed tomography (PET/CT) has become important in the initial evaluation of disease extent. It is superior to other imaging modalities for lymph node status and distant metastasis. PET-defined cervical tumor volume predicts progression-free and overall survival. Higher FDG uptake in both primary and regional lymph nodes is strongly predictive of worse outcome. FDG-PET is useful for assessing treatment response 3 months after completing concurrent chemo-radiotherapy (CRT) and predicting long-term survival, and in suspected disease recurrence. In the era of image-guided adaptive radiotherapy, accurately defining disease areas is critical to avoid irradiating normal tissue. Based on additional information provided by FDG-PET, radiation treatment volumes can be modified and higher doses to FDG-positive lymph nodes safely delivered. FDG-PET/CT has been used for image-guided brachytherapy of FDG-avid tumor volume, while respecting low doses to bladder and rectum. Despite survival improvements due to CRT in cervical cancer, disease recurrences continue to be a major problem. Biological rationale exists for combining novel non-cytotoxic agents with CRT, and drugs targeting specific molecular pathways are under clinical development. The integration of these targeted therapies in clinical trials, and the need for accurate predictors of radio-curability is essential. New molecular imaging tracers may help identifying more aggressive tumors. (64)Cu-labeled diacetyl-di(N(4)-methylthiosemicarbazone) is taken up by hypoxic tissues, which may be valuable for prognostication and radiation treatment planning. PET/CT imaging with novel radiopharmaceuticals could further impact cervical cancer treatment as surrogate markers of drug activity at the tumor microenvironment level. The present article reviews the current and emerging role of PET/CT in the management of cervical cancer.
Resumo:
57 patients with acute intussusception were admitted to the Children's Hospital Zurich between 1972 and 1979. All were treated surgically. One died, 7 needed a bowel resection, 9 intussusceptions were difficult and 32 easy to reduce. The retrospectively reviewed data show that the classic symptomatology, beginning suddenly in a healthy male (60%) under 3 years of age (91%) with attacks of colicky pain (81%), vomiting (93%), a palpable abdominal mass (72%) and rectal bleeding (72%), appears during the course of illness or may not be present at all. This leads to misdiagnosis, wrong treatment and worsening of the pathology. Blood per rectum, the most typical symptom, was present in the first hours of illness in only 5%, vomiting in 44% and colicky pain in 33% of the patients. A high degree of awareness is therefore necessary to diagnose intussusception during the first hours of illness, and particular stress must be laid on the accuracy of the diagnosis because reducibility and resection rate depend directly on the duration of the symptoms.