151 resultados para Radiation dose reduction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phase sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging and therefore new and otherwise inaccessible information. The use of gratings as optical elements in hard X-ray phase imaging overcomes some of the problems that have impaired the wider use of phase contrast in X-ray radiography and tomography. So far, to separate the phase information from other contributions detected with a grating interferometer, a phase-stepping approach has been considered, which implies the acquisition of multiple radiographic projections. Here we present an innovative, highly sensitive X-ray tomographic phase-contrast imaging approach based on grating interferometry, which extracts the phase-contrast signal without the need of phase stepping. Compared to the existing phase-stepping approach, the main advantages of this new method dubbed "reverse projection" are not only the significantly reduced delivered dose, without the degradation of the image quality, but also the much higher efficiency. The new technique sets the prerequisites for future fast and low-dose phase-contrast imaging methods, fundamental for imaging biological specimens and in vivo studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Polyomavirus-associated nephropathy (PVAN) is a serious complication and cause of graft loss in kidney transplant recipients. In the absence of specific antiviral drugs, early detection of the disease and reduction of immunosuppressive regimen is the cornerstone of therapy. Cidofovir, a nucleoside analogue, has been found to inhibit BK virus (BKV) replication in vitro and has been proposed as treatment of refractory PVAN at low doses; however, its efficacy has never been demonstrated in randomized controlled trials. METHODS: Cidofovir therapy (0.5 mg/kg at a 2-week interval for eight consecutive doses) was initiated in two patients with biopsy-proven PVAN and persistent BKV DNA viraemia (> or = 10,000 copies/ml despite sustained reduction of the immunosuppressive regimen). In addition to these two case reports, we performed a critical review of the literature on the use of cidofovir in PVAN. RESULTS: No significant decrease of BKV viral load in blood was observed during cidofovir therapy and in follow-up of the two patients treated with cidofovir. Our literature review identified 21 publications reporting the use of cidofovir for the treatment of PVAN. All were case reports or small series. The efficacy of cidofovir therapy could not be assessed in 17 of these publications because of lack of data or concomitant reduction of immunosuppressive regimen. The four remaining publications were case reports. CONCLUSIONS: In vitro and clinical data to support the efficacy of cidofovir in the treatment of PVAN are currently lacking. More promising compounds should be identified for further clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: When planning SIRT using 90Y microspheres, the partition model is used to refine the activity calculated by the body surface area (BSA) method to potentially improve the safety and efficacy of treatment. For this partition model dosimetry, accurate determination of mean tumor-to-normal liver ratio (TNR) is critical since it directly impacts absorbed dose estimates. This work aimed at developing and assessing a reliable methodology for the calculation of 99mTc-MAA SPECT/CT-derived TNR ratios based on phantom studies. Materials and methods: IQ NEMA (6 hot spheres) and Kyoto liver phantoms with different hot/background activity concentration ratios were imaged on a SPECT/CT (GE Infinia Hawkeye 4). For each reconstruction with the IQ phantom, TNR quantification was assessed in terms of relative recovery coefficients (RC) and image noise was evaluated in terms of coefficient of variation (COV) in the filled background. RCs were compared using OSEM with Hann, Butterworth and Gaussian filters, as well as FBP reconstruction algorithms. Regarding OSEM, RCs were assessed by varying different parameters independently, such as the number of iterations (i) and subsets (s) and the cut-off frequency of the filter (fc). The influence of the attenuation and diffusion corrections was also investigated. Furthermore, both 2D-ROIs and 3D-VOIs contouring were compared. For this purpose, dedicated Matlab© routines were developed in-house for automatic 2D-ROI/3D-VOI determination to reduce intra-user and intra-slice variability. Best reconstruction parameters and RCs obtained with the IQ phantom were used to recover corrected TNR in case of the Kyoto phantom for arbitrary hot-lesion size. In addition, we computed TNR volume histograms to better assess uptake heterogeneityResults: The highest RCs were obtained with OSEM (i=2, s=10) coupled with the Butterworth filter (fc=0.8). Indeed, we observed a global 20% RC improvement over other OSEM settings and a 50% increase as compared to the best FBP reconstruction. In any case, both attenuation and diffusion corrections must be applied, thus improving RC while preserving good image noise (COV<10%). Both 2D-ROI and 3D-VOI analysis lead to similar results. Nevertheless, we recommend using 3D-VOI since tumor uptake regions are intrinsically 3D. RC-corrected TNR values lie within 17% around the true value, substantially improving the evaluation of small volume (<15 mL) regions. Conclusions: This study reports the multi-parameter optimization of 99mTc MAA SPECT/CT images reconstruction in planning 90Y dosimetry for SIRT. In phantoms, accurate quantification of TNR was obtained using OSEM coupled with Butterworth and RC correction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Sorafenib (Sb) is a multiple kinase inhibitor targeting both tumour cell proliferation and angiogenesis that may further act as a potent radiosensitizer by arresting cells in the most radiosensitive cell cycle phase. This phase I open-label, noncontrolled dose escalation study was performed to determine the safety and maximum tolerated dose (MTD) of Sb in combination with radiation therapy (RT) and temozolomide (TMZ) in 17 patients with newly diagnosed high-grade glioma. METHODS: Patients were treated with RT (60 Gy in 2 Gy fractions) combined with TMZ 75 mg m(-2) daily, and Sb administered at three dose levels (200 mg daily, 200 mg BID, and 400 mg BID) starting on day 8 of RT. Thirty days after the end of RT, patients received monthly TMZ (150-200 mg m(-2) D1-5/28) and Sb (400 mg BID). Pharmacokinetic (PK) analyses were performed on day 8 (TMZ) and on day 21 (TMZ&Sb) (Clinicaltrials ID: NCT00884416). RESULTS: The MTD of Sb was established at 200 mg BID. Dose-limiting toxicities included thrombocytopenia (two patients), diarrhoea (one patient) and hypercholesterolaemia (one patient). Sb administration did not affect the mean area under the curve(0-24) and mean Cmax of TMZ and its metabolite 5-amino-imidazole-4-carboxamide (AIC). Tmax of both TMZ and AIC was delayed from 0.75 (TMZ alone) to 1.5 h (combined TMZ/Sb). The median progression-free survival was 7.9 months (95% confidence interval (CI): 5.4-14.55), and the median overall survival was 17.8 months (95% CI: 14.7-25.6). CONCLUSIONS: Although Sb can be combined with RT and TMZ, significant side effects and moderate outcome results do not support further clinical development in malignant gliomas. The robust PK data of the TMZ/Sb combination could be useful in other cancer settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Whole pelvis intensity modulated radiotherapy (IMRT) is increasingly being used to treat cervical cancer aiming to reduce side effects. Encouraged by this, some groups have proposed the use of simultaneous integrated boost (SIB) to target the tumor, either to get a higher tumoricidal effect or to replace brachytherapy. Nevertheless, physiological organ movement and rapid tumor regression throughout treatment might substantially reduce any benefit of this approach. PURPOSE: To evaluate the clinical target volume - simultaneous integrated boost (CTV-SIB) regression and motion during chemo-radiotherapy (CRT) for cervical cancer, and to monitor treatment progress dosimetrically and volumetrically to ensure treatment goals are met. METHODS AND MATERIALS: Ten patients treated with standard doses of CRT and brachytherapy were retrospectively re-planned using a helical Tomotherapy - SIB technique for the hypothetical scenario of this feasibility study. Target and organs at risk (OAR) were contoured on deformable fused planning-computed tomography and megavoltage computed tomography images. The CTV-SIB volume regression was determined. The center of mass (CM) was used to evaluate the degree of motion. The Dice's similarity coefficient (DSC) was used to assess the spatial overlap of CTV-SIBs between scans. A cumulative dose-volume histogram modeled estimated delivered doses. RESULTS: The CTV-SIB relative reduction was between 31 and 70%. The mean maximum CM change was 12.5, 9, and 3 mm in the superior-inferior, antero-posterior, and right-left dimensions, respectively. The CTV-SIB-DSC approached 1 in the first week of treatment, indicating almost perfect overlap. CTV-SIB-DSC regressed linearly during therapy, and by the end of treatment was 0.5, indicating 50% discordance. Two patients received less than 95% of the prescribed dose. Much higher doses to the OAR were observed. A multiple regression analysis showed a significant interaction between CTV-SIB reduction and OAR dose increase. CONCLUSIONS: The CTV-SIB had important regression and motion during CRT, receiving lower therapeutic doses than expected. The OAR had unpredictable shifts and received higher doses. The use of SIB without frequent adaptation of the treatment plan exposes cervical cancer patients to an unpredictable risk of under-dosing the target and/or overdosing adjacent critical structures. In that scenario, brachytherapy continues to be the gold standard approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: BK virus associated nephropathy occurs in 1-10% of kidney transplant recipients and may be a cause of graft loss. This infection is difficult to manage because of the absence of specific therapy. Cidofovir, a DNA polymerase inhibitor approved for the treatment of CMV retinitis, has shown in vitro activity against BK virus and some clinical efficacy when used at low-dose in uncontrolled series. Objective: To assess the efficacy of low-dose Cidofovir in the treatment of BK virus associated nephropathy. Method: Two adult kidney transplant recipients with biopsy-proven BK nephropathy and persistent high viremia (>10,000 copies/ml) despite 3-month reduction of immunosuppressive therapy were treated by Cidofovir 0.5 mg/kg fortnightly for a total of 16 weeks (8 doses). Clinical response was assessed by following BK viremia. Results: No decrease in BK viremia was observed at any point during cidofovir therapy (see figure). Creatinine clearance remained stable during therapy and no side-effects of Cidofovir were observed. Conclusions: Low-dose Cidofovir therapy was not associated with a clearance or with a significant decrease of BK viremia. This pilot study does not confirm previous reports suggesting clinical efficacy of Cidofovir for BK virus associated nephropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Preclinical data indicate activity of mammalian target of rapamycin inhibitors and synergistic activity together with radiotherapy in glioblastoma. The aim of this trial is to assess the therapeutic activity of temsirolimus (CCI-779), an intravenous mTOR inhibitor, in patients with newly diagnosed glioblastoma with unmethylated O6 methlyguanine-DNA-methlytransferase (MGMT)promoter. Methods: Patients (n=257) with newly diagnosed glioblastoma after open surgical biopsy or resection fulfilling basic eligibility criteria underwent a central MGMT promoter analysis using quantitative methylation specific PCR. Patients with glioblastoma harboring an unmethylated MGMT promoter (n=111) were randomized 1:1 between radiotherapy (60 Gy; 5 times 2 Gy per week) plus concomitant and six cycles of maintenance temozolomide or radiotherapy plus weekly temsirolimus at 25 mg flat dose to be continued until progression or undue toxicity. Primary endpoint was overall survival at 12 months (OS12). Sample size of the investigational treatment arm required 54 patients to assess adequacy of temsirolimus activity set at 80%. More than 38 patients alive at 12 months in the per protocol population was considered a positive signal. A control arm of 54 patients treated with the standard of care was implemented to evaluate the assumptions on OS12. Results: Between December 2009 and October 2012, 111 pts in 14 centers were randomized and treated. Median age was 55 and 58 years in the temsirolimus and standard arm, respectively. Most patients (95.5%) had a WHO performance status of 0 or 1. Both therapies were properly administered with a median of 13 cycles of maintenance temsirolimus. In the per protocolpopulation, exactly 38 patients treated with temsirolimus (out of 54 eligible) reached OS12. In the intention to treat population OS12 was 72.2% [95% CI (58.2, 82.2)] in the temozolomide arm and 69.6% [95% CI (55.8, 79.9) in the temsirolimus arm [HR=1.16 95% CI (0.77, 1.76), p=0.47]. Conclusions: The therapeutic activity of temsirolimus in patients with newly diagnosed glioblastoma with an unmethylated MGMT promoter is too low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efavirenz dosage adjustment in several patients with high EFV levels and presenting CNS toxicity have been successfully achieved in Switerland over the past seven years but many others have not beneficiated from dosage reduction owing to the lack of prospective studies evaluating the safety and clinical benefit of reduced dosage regimens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dans la prise en charge des maladies oncologiques, la priorité est évidemment d'assurer le contrôle de la maladie (soit le taux de récidive local et la survie globale), surtout lorsque celle-ci est diagnostiquée tôt, à un stade précoce. Cependant, lorsque la maladie est plus avancée et que ce contrôle ne peut être assuré de façon raisonnable, l'accent de la prise en charge est surtout axé sur le confort du patient. Le principe est de fournir à celui-ci, dans la mesure du possible, une qualité de vie acceptable, avec notamment des douleurs bien contrôlées.Dans le cadre de ce travail de thèse, nous nous sommes intéressés à la prise en charge palliative des lymphomes non hodgkiniens (LNH) de bas grade. La survie de ces patients peut être relativement longue (de 5 à 10 ans selon les séries), cependant, le traitement est rarement à visée curative, contrairement aux lymphomes de haut grade, dont la survie est bien moindre, mais avec une chance de guérison après un traitement intensif.Plusieurs études cliniques, à la fois prospectives et rétrospectives, ont démontré l'intérêt d'une irradiation à faible dose {2x2 Gy) lors d'atteintes tymphomateuses à l'origine de symptômes gênants (douleurs, compression par une masse, dyspnée, entre autres). Etant donné la facilité d'administration de ce traitement (seulement 2 séances de radiothérapie sont nécessaires), et sa quasi absence de survenue d'effets secondaires avec cette faible dose totale (4 Gy), nous avons voulu y apporter une contribution suisse.Notre étude rétrospective a permis d'inclure 43 patients entre le CHUV et les HUG. Les résultats que nous avons obtenus sont également dans la ligne des autres études parues, avec un excellent contrôle local, soit un soulagement rapide et durable des symptômes dans la majorité des cas.Nous espérons que ce travail de thèse, publié sous forme d'un article dans « International Journal of Radiation Oncology, Biology, Physics », permettra une prise en charge plus optimale des ces patients en leur apportant un traitement facile à administrer, efficace, sans effets secondaires dans la majorité des cas, et pouvant être répété un grand nombre de fois si nécessaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the rate of tumor recurrence within the irradiated volume after initial low-dose irradiation of limited-stage small-cell lung cancer (SCLC), to assess the tolerance of a sequential combination of low-dose chest irradiation followed by chemotherapy, and to confirm the responsiveness of limited-stage SCLC to low-dose irradiation. METHODS AND MATERIALS: In this pilot study, 26 patients with limited-stage SCLC were treated by first-line 20-Gy thoracic irradiation followed 3 weeks later by chemotherapy (cisplatin, doxorubicin, and etoposide for six cycles). RESULTS: We present our final results with a median follow-up of surviving patients of 7 years. The response rate to this low-dose irradiation was 83%, with an overall response rate to radiochemotherapy of 96% and a median survival of 21 months. No unexpected early or late toxicity was observed. The rate of initial isolated local failure was 8%, which compares favorably with other published series using higher doses of radiochemotherapy. CONCLUSION: An initial chest irradiation of 20 Gy before chemotherapy could be sufficient to reduce the risk of local failure during the time of survival of patients with limited-stage SCLC. Potential advantages of this treatment may be the prevention of resistance mechanisms to radiotherapy induced by preliminary chemotherapy and a reduced radiation-induced toxicity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A nation-wide survey on radiation doses in diagnostic and interventional radiology was conducted in Switzerland in 1998 aiming at establishing their collective radiological impact on the Swiss population. The study consisted on the one hand of surveying the frequency of more than 250 types of examinations, covering conventional radiology, mammography, fluoroscopy, angiography, interventional radiology, CT, bone densitometry, conventional tomography and dental radiology. On the other hand, for each type of examination the associated patient dose was established by modeling. The results of this study show that about 9.5 million diagnostic and interventional examinations are performed annually in Switzerland (1.34 per caput) and that the associated annual collective dose is of the order of 7100 person.Sv (1.0 mSv per caput). Switzerland is similar to other European countries in terms of the frequency of examinations and the collective dose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. MATERIALS AND METHODS: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. RESULTS: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10cm from the PTV border the Tomotherapy up to 35cm. CONCLUSIONS: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35cm from the PTV border (for a 390 cm(3) large PTV).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To study the dosimetric properties and clinical implementation of a carotid dose sparing irradiation protocol using helical Tomotherapy in early stage laryngeal cancer.Materials and Methods: We have developed a simple treatment planning algorithm for carotid sparing. We have compared carotid and critical organ doses and planned target volume (PTV) dose with our standard laryngeal irradiation protocol. Dose constraints were the following: maximum point dose to the carotids <35 Gy, to the spinal cord <30 Gy, and PTV was covered at >95% of the prescribed dose (70 Gy in 2 Gy per fraction). A daily megavoltage CT was done to account for patient movement and anatomy modification. To date, 7 patients have been treated with this protocol in our department.Results: Our early results showed a significant reduction in the carotid dose with an average maximum dose of 35.8 Gy. The average maximum spinal cord dose was 25.8 Gy. PTV was covered without important "hot spots". Average maximum dose in the PTV was 74.1 Gy with an average absolute maximum dose of 75.2 Gy. To date, the clinical outcomes have been excellent.Conclusion: Helical Tomotherapy allows a significant decrease of carotid dose without dangerous spinal cord overdose. There was no important overdose in the PTV that can potentially increase the late complication risks. Daily control imaging brings added security especially when working with such high-dose gradients. We think further studies and longer follow-up are needed to investigate the clinical outcomes such as the local control rate and the vascular late toxicities.