208 resultados para Motion perception


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relaxation rates provide important information about tissue microstructure. Multi-parameter mapping (MPM) estimates multiple relaxation parameters from multi-echo FLASH acquisitions with different basic contrasts, i.e., proton density (PD), T1 or magnetization transfer (MT) weighting. Motion can particularly affect maps of the apparent transverse relaxation rate R2(*), which are derived from the signal of PD-weighted images acquired at different echo times. To address the motion artifacts, we introduce ESTATICS, which robustly estimates R2(*) from images even when acquired with different basic contrasts. ESTATICS extends the fitted signal model to account for inherent contrast differences in the PDw, T1w and MTw images. The fit was implemented as a conventional ordinary least squares optimization and as a robust fit with a small or large confidence interval. These three different implementations of ESTATICS were tested on data affected by severe motion artifacts and data with no prominent motion artifacts as determined by visual assessment or fast optical motion tracking. ESTATICS improved the quality of the R2(*) maps and reduced the coefficient of variation for both types of data-with average reductions of 30% when severe motion artifacts were present. ESTATICS can be applied to any protocol comprised of multiple 2D/3D multi-echo FLASH acquisitions as used in the general research and clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the impact of in-plane coronary artery motion on coronary magnetic resonance angiography (MRA) and coronary MR vessel wall imaging. Free-breathing, navigator-gated, 3D-segmented k-space turbo field echo ((TFE)/echo-planar imaging (EPI)) coronary MRA and 2D fast spin-echo coronary vessel wall imaging of the right coronary artery (RCA) were performed in 15 healthy adult subjects. Images were acquired at two different diastolic time periods in each subject: 1) during a subject-specific diastasis period (in-plane velocity <4 cm/second) identified from analysis of in-plane coronary artery motion, and 2) using a diastolic trigger delay based on a previously implemented heart-rate-dependent empirical formula. RCA vessel wall imaging was only feasible with subject-specific middiastolic acquisition, while the coronary wall could not be identified with the heart-rate-dependent formula. For coronary MRA, RCA border definition was improved by 13% (P < 0.001) with the use of subject-specific trigger delay (vs. heart-rate-dependent delay). Subject-specific middiastolic image acquisition improves 3D TFE/EPI coronary MRA, and is critical for RCA vessel wall imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a realistic simulator for the Computed Tomography (CT) scan process for motion analysis. In fact, we are currently developing a new framework to find small motion from the CT scan. In order to prove the fidelity of this framework, or potentially any other algorithm, we present in this paper a simulator to simulate the whole CT acquisition process with a priori known parameters. In other words, it is a digital phantom for the motion analysis that can be used to compare the results of any related algorithm with the ground-truth realistic analytical model. Such a simulator can be used by the community to test different algorithms in the biomedical imaging domain. The most important features of this simulator are its different considerations to simulate the best the real acquisition process and its generality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The velocity of a liquid slug falling in a capillary tube is lower than predicted for Poiseuille flow due to presence of menisci, whose shapes are determined by the complex interplay of capillary, viscous, and gravitational forces. Due to the presence of menisci, a capillary pressure proportional to surface curvature acts on the slug and streamlines are bent close to the interface, resulting in enhanced viscous dissipation at the wedges. To determine the origin of drag-force increase relative to Poiseuille flow, we compute the force resultant acting on the slug by integrating Navier-Stokes equations over the liquid volume. Invoking relationships from differential geometry we demonstrate that the additional drag is due to viscous forces only and that no capillary drag of hydrodynamic origin exists (i.e., due to hydrodynamic deformation of the interface). Requiring that the force resultant is zero, we derive scaling laws for the steady velocity in the limit of small capillary numbers by estimating the leading order viscous dissipation in the different regions of the slug (i.e., the unperturbed Poiseuille-like bulk, the static menisci close to the tube axis and the dynamic regions close to the contact lines). Considering both partial and complete wetting, we find that the relationship between dimensionless velocity and weight is, in general, nonlinear. Whereas the relationship obtained for complete-wetting conditions is found in agreement with the experimental data of Bico and Quere [J. Bico and D. Quere, J. Colloid Interface Sci. 243, 262 (2001)], the scaling law under partial-wetting conditions is validated by numerical simulations performed with the Volume of Fluid method. The simulated steady velocities agree with the behavior predicted by the theoretical scaling laws in presence and in absence of static contact angle hysteresis. The numerical simulations suggest that wedge-flow dissipation alone cannot account for the entire additional drag and that the non-Poiseuille dissipation in the static menisci (not considered in previous studies) has to be considered for large contact angles.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a previous work we have shown that sinusoidal whole-body rotations producing continuous vestibular stimulation, affected the timing of motor responses as assessed with a paced finger tapping (PFT) task (Binetti et al. (2010). Neuropsychologia, 48(6), 1842-1852). Here, in two new psychophysical experiments, one purely perceptual and one with both sensory and motor components, we explored the relationship between body motion/vestibular stimulation and perceived timing of acoustic events. In experiment 1, participants were required to discriminate sequences of acoustic tones endowed with different degrees of acceleration or deceleration. In this experiment we found that a tone sequence presented during acceleratory whole-body rotations required a progressive increase in rate in order to be considered temporally regular, consistent with the idea of an increase in "clock" frequency and of an overestimation of time. In experiment 2 participants produced self-paced taps, which entailed an acoustic feedback. We found that tapping frequency in this task was affected by periodic motion by means of anticipatory and congruent (in-phase) fluctuations irrespective of the self-generated sensory feedback. On the other hand, synchronizing taps to an external rhythm determined a completely opposite modulation (delayed/counter-phase). Overall this study shows that body displacements "remap" our metric of time, affecting not only motor output but also sensory input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: A new magnetic resonance imaging approach for detection of myocardial late enhancement during free-breathing was developed. METHODS AND RESULTS: For suppression of respiratory motion artifacts, a prospective navigator technology including real-time motion correction and a local navigator restore was implemented. Subject specific inversion times were defined from images with incrementally increased inversion times acquired during a single dynamic scout navigator-gated and real-time motion corrected free-breathing scan. Subsequently, MR-imaging of myocardial late enhancement was performed with navigator-gated and real-time motion corrected adjacent short axis and long axis (two, three and four chamber) views. This alternative approach was investigated in 7 patients with history of myocardial infarction 12 min after i. v. administration of 0.2 mmol/kg body weight gadolinium-DTPA. CONCLUSION: With the presented navigator-gated and real-time motion corrected sequence for MR-imaging of myocardial late enhancement data can be completely acquired during free-breathing. Time constraints of a breath-hold technique are abolished and optimized patient specific inversion time is ensured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seeing seems effortless, despite the need to segregate and integrate visual information that varies in quality, quantity, and location. The extent to which seeing passively recapitulates the external world is challenged by phenomena such as illusory contours, an example of visual completion whereby borders are perceived despite their physical absence in the image. Instead, visual completion and seeing are increasingly conceived as active processes, dependent on information exchange across neural populations. How this is instantiated in the brain remains controversial. Divergent models emanate from single-unit and population-level electrophysiology, neuroimaging, and neurostimulation studies. We reconcile discrepant findings from different methods and disciplines, and underscore the importance of taking into account spatiotemporal brain dynamics in generating models of brain function and perception.