285 resultados para Metagenomic comparison of endemic viruses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The analysis of conservation between the human and mouse genomes resulted in the identification of a large number of conserved nongenic sequences (CNGs). The functional significance of this nongenic conservation remains unknown, however. The availability of the sequence of a third mammalian genome, the dog, allows for a large-scale analysis of evolutionary attributes of CNGs in mammals. We have aligned 1638 previously identified CNGs and 976 conserved exons (CODs) from human chromosome 21 (Hsa21) with their orthologous sequences in mouse and dog. Attributes of selective constraint, such as sequence conservation, clustering, and direction of substitutions were compared between CNGs and CODs, showing a clear distinction between the two classes. We subsequently performed a chromosome-wide analysis of CNGs by correlating selective constraint metrics with their position on the chromosome and relative to their distance from genes. We found that CNGs appear to be randomly arranged in intergenic regions, with no bias to be closer or farther from genes. Moreover, conservation and clustering of substitutions of CNGs appear to be completely independent of their distance from genes. These results suggest that the majority of CNGs are not typical of previously described regulatory elements in terms of their location. We propose models for a global role of CNGs in genome function and regulation, through long-distance cis or trans chromosomal interactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Primary intellectual abilities (PIA) are a confounder in epidemiological studies on neurotoxicity. A good measure of this confounder should be independent of age as PIA is an intrinsic ability. Furthermore, as PIA is related to health endpoints, any measure of PIA should reveal this association. This study is aimed at comparing vocabulary test, diploma and age at end of schooling properties as measures of PIA in a non-exposed population of workers. METHODS: The design was a cross-sectional study of 413 non-exposed workers (203 women and 210 men) selected from a health check-up center. The effect of age on the vocabulary score was assessed using an analysis of covariance adjusted for diploma. Relationships between neuropsychological performances and vocabulary score, diploma and end of schooling age were, respectively, assessed using multiple linear regressions adjusted for age and gender. RESULTS: Vocabulary score increased significantly with age, both for men and women. The increase was 0.14 word per year for women, and 0.18 word per year for men. The explained variance of the models evaluating the relationships between age at end of schooling, diploma, vocabulary test, and neuropsychological performances was quite similar for the three measures of PIA. CONCLUSIONS: Vocabulary score was found to be age-related, even after adjustment for diploma. No difference was found between these three variables in terms of their relationship to neuropsychological endpoints. Moreover, the literature shows that vocabulary test performances are influenced by exposure to neurotoxic agents. These results suggest that vocabulary score could be of interest for participants of similar ages and similar diplomas. Otherwise, the other two variables would be better PIA measures in neurotoxicology studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compare the primary sex ratio (proportion o haploid eggs laid by queens) and the secondary sex ratio (proportion of male pupae produced) in the Argentine ant Iridomyrmex humilis with the aim of investigating whether workers control the secondary sex ratio by selectively eliminating male brood. The proportion of haploid eggs produced by queens was close to 0.5 in late winter, decreased to less than 0.3 in spring and summer, and increased again to a value close to 0.5 in fall. Laboratory experiments indicate that temperture is a proximate factor influencing the primary sex ratio with a higher proportion of haploid eggs being laid at colder temperatures. Production of queen pupae ceased in mid-June, about three weeks before that of male pupae. After this time only worker pupae were produced. During the period of production of sexuals, the proportion of male pupae ranged from 0.30 to 0.38. Outside this period no males were reared although haploid eggs were produced all the year round by queens. Workers thus exert a control on the secondary sex ratio by eliminating a proportion of the male brood during the period of sexual production and eliminating all the males during the remainder of the cycle. These data are consistent with workers preferring a more female-biased sex ratio than queens. The evolutionary significance of the production of male eggs by queens all the year round is as yet unclear. It may be a mechanism allowing queen replacement in the case of the death of the queens in the colony.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: There are guidelines on how to develop a food challenge protocol, but at present there is no gold standard guidance on method, and separate units produce differing protocols. METHODS: We performed a retrospective analysis of 200 patients' data from the paediatric allergy units in Lausanne and Geneva, Western Switzerland, and St Thomas' Hospital (STH), UK. RESULTS: St Thomas' Hospital has a younger cohort with a lower overall mean spIgE (2.36 kU/l vs 8.00 kU/l, P = 0.004). The target peanut protein volumes differed: Switzerland 4.4 g vs STH 8.4 g. Despite this, the dose actually achieved in positive challenges was not significantly different (2.33 g vs 1.49 g, P = 0.16). 26% of challenges reacted at 4 g or more of peanut protein. CONCLUSIONS: The differences in results highlight how the variation in reasoning behind food challenge alters the outcome. Standardization of food challenges would allow easy comparison between hospitals and geographical areas for research purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is increasing evidence to suggest that the presence of mesoscopic heterogeneities constitutes the predominant attenuation mechanism at seismic frequencies. As a consequence, centimeter-scale perturbations of the subsurface physical properties should be taken into account for seismic modeling whenever detailed and accurate responses of the target structures are desired. This is, however, computationally prohibitive since extremely small grid spacings would be necessary. A convenient way to circumvent this problem is to use an upscaling procedure to replace the heterogeneous porous media by equivalent visco-elastic solids. In this work, we solve Biot's equations of motion to perform numerical simulations of seismic wave propagation through porous media containing mesoscopic heterogeneities. We then use an upscaling procedure to replace the heterogeneous poro-elastic regions by homogeneous equivalent visco-elastic solids and repeat the simulations using visco-elastic equations of motion. We find that, despite the equivalent attenuation behavior of the heterogeneous poro-elastic medium and the equivalent visco-elastic solid, the seismograms may differ due to diverging boundary conditions at fluid-solid interfaces, where there exist additional options for the poro-elastic case. In particular, we observe that the seismograms agree for closed-pore boundary conditions, but differ significantly for open-pore boundary conditions. This is an interesting result, which has potentially important implications for wave-equation-based algorithms in exploration geophysics involving fluid-solid interfaces, such as, for example, wave field decomposition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Given the adverse impact of image noise on the perception of important clinical details in digital mammography, routine quality control measurements should include an evaluation of noise. The European Guidelines, for example, employ a second-order polynomial fit of pixel variance as a function of detector air kerma (DAK) to decompose noise into quantum, electronic and fixed pattern (FP) components and assess the DAK range where quantum noise dominates. This work examines the robustness of the polynomial method against an explicit noise decomposition method. The two methods were applied to variance and noise power spectrum (NPS) data from six digital mammography units. Twenty homogeneously exposed images were acquired with PMMA blocks for target DAKs ranging from 6.25 to 1600 µGy. Both methods were explored for the effects of data weighting and squared fit coefficients during the curve fitting, the influence of the additional filter material (2 mm Al versus 40 mm PMMA) and noise de-trending. Finally, spatial stationarity of noise was assessed.Data weighting improved noise model fitting over large DAK ranges, especially at low detector exposures. The polynomial and explicit decompositions generally agreed for quantum and electronic noise but FP noise fraction was consistently underestimated by the polynomial method. Noise decomposition as a function of position in the image showed limited noise stationarity, especially for FP noise; thus the position of the region of interest (ROI) used for noise decomposition may influence fractional noise composition. The ROI area and position used in the Guidelines offer an acceptable estimation of noise components. While there are limitations to the polynomial model, when used with care and with appropriate data weighting, the method offers a simple and robust means of examining the detector noise components as a function of detector exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Efficacy and tumour selectivity of photodynamic therapy with two clinically approved sensitizers (mTHPC, verteporfin) were assessed for focal intracavitary photodynamic therapy (PDT) in rodents with malignant pleural mesothelioma (MPM) at recommended drug-light conditions and at escalating sensitizer dosages. MPM tumours were generated in 15 Fischer rats by subpleural mediastinal tumour cell injection followed after 5 days by intracavitary PDT with light delivery monitored by in situ dosimetry. Animals were intravenously sensitized either with mTHPC (0.1 mg/kg, n = 3; 0.2 mg/kg, n = 3) followed after 4 days by illumination with 20 J/cm(2) at 652 nm, or with verteporfin (0.6 mg/kg, n = 3; 1.2 mg/kg, n = 3) followed after 20 min by illumination with 100 J/cm(2) at 689 nm. Three untreated tumour-bearing animals served as controls. Histological evaluation of the treated tumour and of adjacent normal organs was performed 10 days after tumour implantation. The extent of PDT-induced tumour necrosis was compared to the non-necrosed area and expressed in percentage. A locally invasive growing MPM tumour (3.1 +/- 1 mm diameter) without spontaneous necrosis diameter was found in all animals. For both sensitizers, focal intracavitary PDT was well tolerated at drug-light conditions recommended for clinical applications. Mediastinal organs were spared for both sensitizers but verteporfin resulted in a higher extent of tumour necrosis (80%) than mTHPC (50%). Drug dose escalation revealed a higher extent of PDT-related tumour necrosis for both sensitizers (mTHPC 55%, verteporfin 88%), however, verteporfin-PDT was associated with a higher toxicity than mTHPC-PDT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Few studies compare the variabilities that characterize environmental (EM) and biological monitoring (BM) data. Indeed, comparing their respective variabilities can help to identify the best strategy for evaluating occupational exposure. The objective of this study is to quantify the biological variability associated with 18 bio-indicators currently used in work environments. METHOD: Intra-individual (BV(intra)), inter-individual (BV(inter)), and total biological variability (BV(total)) were quantified using validated physiologically based toxicokinetic (PBTK) models coupled with Monte Carlo simulations. Two environmental exposure profiles with different levels of variability were considered (GSD of 1.5 and 2.0). RESULTS: PBTK models coupled with Monte Carlo simulations were successfully used to predict the biological variability of biological exposure indicators. The predicted values follow a lognormal distribution, characterized by GSD ranging from 1.1 to 2.3. Our results show that there is a link between biological variability and the half-life of bio-indicators, since BV(intra) and BV(total) both decrease as the biological indicator half-lives increase. BV(intra) is always lower than the variability in the air concentrations. On an individual basis, this means that the variability associated with the measurement of biological indicators is always lower than the variability characterizing airborne levels of contaminants. For a group of workers, BM is less variable than EM for bio-indicators with half-lives longer than 10-15 h. CONCLUSION: The variability data obtained in the present study can be useful in the development of BM strategies for exposure assessment and can be used to calculate the number of samples required for guiding industrial hygienists or medical doctors in decision-making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We prospectively compared the diagnostic value of C-reactive protein (CRP) and white blood cell counts for detection of neonatal septicaemia. Sensitivity and specifity in receiver operating characteristics, and positive and negative predictive value of CRP and white blood cell count were compared in 195 critically ill preterm and term newborns clinically suspected of infection. Blood cultures were positive in 33 cases. During the first 3 days after birth CRP elevation (sensitivity 75%, specifity 86%), leukopenia (67%/90%), neutropenia (78%/80%) and immature to total neutrophil count (I/T) ratio (78%/73%) were good diagnostic parameters, as opposed to band forms with absolute count (84%/66%) or percentage (79%/71%), thrombocytopenia (65%/57%) and toxic granulations (44%/94%). Beyond 3 days of age elevated CRP (88%/87%) was the best parameter. Increased total (84%/66%) or percentage band count (79%/71%) were also useful. Leukocytosis (74%/56%), increased neutrophils (67%/65%), I/T ratio (79%/47%), thrombocytopenia (65%/57%) and toxic granulations had a low specifity. The positive predictive value of CRP was 32% before and 37% after 3 days of age, that of leukopenia was 37% in the first 3 days. CONCLUSION: During the first 3 days of life CRP, leukopenia and neutropenia were comparably good tests while after 3 days of life CRP was the best single test in early detection of neonatal septicaemia. Serial CRP estimations confirm the diagnosis, monitor the course of infection and the efficacy of antibiotic treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most widely used formula for estimating glomerular filtration rate (eGFR) in children is the Schwartz formula. It was revised in 2009 using iohexol clearances with measured GFR (mGFR) ranging between 15 and 75 ml/min × 1.73 m(2). Here we assessed the accuracy of the Schwartz formula using the inulin clearance (iGFR) method to evaluate its accuracy for children with less renal impairment comparing 551 iGFRs of 392 children with their Schwartz eGFRs. Serum creatinine was measured using the compensated Jaffe method. In order to find the best relationship between iGFR and eGFR, a linear quadratic regression model was fitted and a more accurate formula was derived. This quadratic formula was: 0.68 × (Height (cm)/serum creatinine (mg/dl))-0.0008 × (height (cm)/serum creatinine (mg/dl))(2)+0.48 × age (years)-(21.53 in males or 25.68 in females). This formula was validated using a split-half cross-validation technique and also externally validated with a new cohort of 127 children. Results show that the Schwartz formula is accurate until a height (Ht)/serum creatinine value of 251, corresponding to an iGFR of 103 ml/min × 1.73 m(2), but significantly unreliable for higher values. For an accuracy of 20 percent, the quadratic formula was significantly better than the Schwartz formula for all patients and for patients with a Ht/serum creatinine of 251 or greater. Thus, the new quadratic formula could replace the revised Schwartz formula, which is accurate for children with moderate renal failure but not for those with less renal impairment or hyperfiltration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Protein-energy malnutrition is highly prevalent in aged populations. Associated clinical, economic, and social burden is important. A valid screening method that would be robust and precise, but also easy, simple, and rapid to apply, is essential for adequate therapeutic management. OBJECTIVES: To compare the interobserver variability of 2 methods measuring food intake: semiquantitative visual estimations made by nurses versus calorie measurements performed by dieticians on the basis of standardized color digital photographs of servings before and after consumption. DESIGN: Observational monocentric pilot study. SETTING/PARTICIPANTS: A geriatric ward. The meals were randomly chosen from the meal tray. The choice was anonymous with respect to the patients who consumed them. MEASUREMENTS: The test method consisted of the estimation of calorie consumption by dieticians on the basis of standardized color digital photographs of servings before and after consumption. The reference method was based on direct visual estimations of the meals by nurses. Food intake was expressed in the form of a percentage of the serving consumed and calorie intake was then calculated by a dietician based on these percentages. The methods were applied with no previous training of the observers. Analysis of variance was performed to compare their interobserver variability. RESULTS: Of 15 meals consumed and initially examined, 6 were assessed with each method. Servings not consumed at all (0% consumption) or entirely consumed by the patient (100% consumption) were not included in the analysis so as to avoid systematic error. The digital photography method showed higher interobserver variability in calorie intake estimations. The difference between the compared methods was statistically significant (P < .03). CONCLUSIONS: Calorie intake measures for geriatric patients are more concordant when estimated in a semiquantitative way. Digital photography for food intake estimation without previous specific training of dieticians should not be considered as a reference method in geriatric settings, as it shows no advantages in terms of interobserver variability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Finding genes that are differentially expressed between conditions is an integral part of understanding the molecular basis of phenotypic variation. In the past decades, DNA microarrays have been used extensively to quantify the abundance of mRNA corresponding to different genes, and more recently high-throughput sequencing of cDNA (RNA-seq) has emerged as a powerful competitor. As the cost of sequencing decreases, it is conceivable that the use of RNA-seq for differential expression analysis will increase rapidly. To exploit the possibilities and address the challenges posed by this relatively new type of data, a number of software packages have been developed especially for differential expression analysis of RNA-seq data. RESULTS: We conducted an extensive comparison of eleven methods for differential expression analysis of RNA-seq data. All methods are freely available within the R framework and take as input a matrix of counts, i.e. the number of reads mapping to each genomic feature of interest in each of a number of samples. We evaluate the methods based on both simulated data and real RNA-seq data. CONCLUSIONS: Very small sample sizes, which are still common in RNA-seq experiments, impose problems for all evaluated methods and any results obtained under such conditions should be interpreted with caution. For larger sample sizes, the methods combining a variance-stabilizing transformation with the 'limma' method for differential expression analysis perform well under many different conditions, as does the nonparametric SAMseq method.