211 resultados para MECHANICAL FLOCCULATION UNIT
Resumo:
Hospitalization in older patients is frequently associated with functional decline. Hospital factors and inadapted process of care are factors leading to this decline. Acute care units specifically developed for older patients can prevent functional decline. These units usually include a comprehensive geriatric evaluation, an interdisciplinary meeting, protocols for the treatment of geriatric syndromes and specific teaching for the care team. Globally, patients' cares are organized to preserve and improve functional performances. This article presents a pilot unit inspired by this model.
Resumo:
Neurally adjusted ventilatory assist or NAVA is a new assisted ventilatory mode which, in comparison with pressure support, leads to improved patient-ventilator synchrony and a more variable ventilatory pattern. It also improves arterial oxygenation. With NAVA, the electrical activity of the diaphragm is recorded through a nasogastric tube equipped with electrodes. This electrical activity is then used to pilot the ventilator. With NAVA, the patient's respiratory pattern controls the ventilator's timing of triggering and cycling as well as the magnitude of pressurization, which is proportional to inspiratory demand. The effect of NAVA on patient outcome remains to be determined through well-designed prospective studies.
Resumo:
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
Cell-wall mechanical properties play a key role in the growth and the protection of plants. However, little is known about genuine wall mechanical properties and their growth-related dynamics at subcellular resolution and in living cells. Here, we used atomic force microscopy (AFM) stiffness tomography to explore stiffness distribution in the cell wall of suspension-cultured Arabidopsis thaliana as a model of primary, growing cell wall. For the first time that we know of, this new imaging technique was performed on living single cells of a higher plant, permitting monitoring of the stiffness distribution in cell-wall layers as a function of the depth and its evolution during the different growth phases. The mechanical measurements were correlated with changes in the composition of the cell wall, which were revealed by Fourier-transform infrared (FTIR) spectroscopy. In the beginning and end of cell growth, the average stiffness of the cell wall was low and the wall was mechanically homogenous, whereas in the exponential growth phase, the average wall stiffness increased, with increasing heterogeneity. In this phase, the difference between the superficial and deep wall stiffness was highest. FTIR spectra revealed a relative increase in the polysaccharide/lignin content.
Resumo:
BACKGROUND: Tracheal intubation may be more difficult in morbidly obese (MO) patients than in the non-obese. The aim of this study was to evaluate clinically if the use of the Video Intubation Unit (VIU), a video-optical intubation stylet, could improve the laryngoscopic view compared with the standard Macintosh laryngoscope in this specific population. METHODS: We studied 40 MO patients (body mass index >35 kg/m(2)) scheduled for bariatric surgery. Each patient had a conventional laryngoscopy and a VIU inspection. The laryngoscopic grades (LG) using the Cormack and Lehane scoring system were noted and compared. Thereafter, the patients were randomised to be intubated with one of the two techniques. In one group, the patients were intubated with the help of the VIU and in the control group, tracheal intubation was performed conventionally. The duration of intubation, as well as the minimal SpO(2) achieved during the procedure, were measured. RESULTS: Patient characteristics were similar in both groups. Seventeen patients had a direct LG of 2 or 3 (no patient had a grade of 4). Out of these 17 patients, the LG systematically improved with the VIU and always attained grade 1 (P<0.0001). The intubation time was shorter within the VIU group, but did not attain significance. There was no difference in the SpO(2) post-intubation. CONCLUSION: In MO patients, the use of the VIU significantly improves the visualisation of the larynx, thereby improving the intubation conditions.
Resumo:
Patients admitted to the neurocritical care unit (NCCU) often have serious conditions that can be associated with high morbidity and mortality. Pharmacologic agents or neuroprotectants have disappointed in the clinical environment. Current NCCU management therefore is directed toward identification, prevention, and treatment of secondary cerebral insults that evolve over time and are known to aggravate outcome. This strategy is based on a variety of monitoring techniques including use of intraparenchymal monitors. This article reviews parenchymal brain oxygen monitors, including the available technologies, practical aspects of use, the physiologic rationale behind their use, and patient management based on brain oxygen.
Resumo:
We present a combined shape and mechanical anisotropy evolution model for a two-phase inclusion-bearing rock subject to large deformation. A single elliptical inclusion embedded in a homogeneous but anisotropic matrix is used to represent a simplified shape evolution enforced on all inclusions. The mechanical anisotropy develops due to the alignment of elongated inclusions. The effective anisotropy is quantified using the differential effective medium (DEM) approach. The model can be run for any deformation path and an arbitrary viscosity ratio between the inclusion and host phase. We focus on the case of simple shear and weak inclusions. The shape evolution of the representative inclusion is largely insensitive to the anisotropy development and to parameter variations in the studied range. An initial hardening stage is observed up to a shear strain of gamma = 1 irrespective of the inclusion fraction. The hardening is followed by a softening stage related to the developing anisotropy and its progressive rotation toward the shear direction. The traction needed to maintain a constant shear rate exhibits a fivefold drop at gamma = 5 in the limiting case of an inviscid inclusion. Numerical simulations show that our analytical model provides a good approximation to the actual evolution of a two-phase inclusion-host composite. However, the inclusions develop complex sigmoidal shapes resulting in the formation of an S-C fabric. We attribute the observed drop in the effective normal viscosity to this structural development. We study the localization potential in a rock column bearing varying fraction of inclusions. In the inviscid inclusion case, a strain jump from gamma = 3 to gamma = 100 is observed for a change of the inclusion fraction from 20% to 33%.
Resumo:
Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.
Resumo:
BACKGROUND: Empirical antibacterial therapy in hospitals is usually guided by local epidemiologic features reflected by institutional cumulative antibiograms. We investigated additional information inferred by aggregating cumulative antibiograms by type of unit or according to the place of acquisition (i.e. community vs. hospital) of the bacteria. MATERIALS AND METHODS: Antimicrobial susceptibility rates of selected pathogens were collected over a 4-year period in an university-affiliated hospital. Hospital-wide antibiograms were compared with those selected by type of unit and sampling time (<48 or >48 h after hospital admission). RESULTS: Strains isolated >48 h after admission were less susceptible than those presumably arising from the community (<48 h). The comparison of units revealed significant differences among strains isolated >48 h after admission. When compared to hospital-wide antibiograms, susceptibility rates were lower in the ICU and surgical units for Escherichia coli to amoxicillin-clavulanate, enterococci to penicillin, and Pseudomonas aeruginosa to anti-pseudomonal beta-lactams, and in medical units for Staphylococcus aureus to oxacillin. In contrast, few differences were observed among strains isolated within 48 h of admission. CONCLUSIONS: Hospital-wide antibiograms reflect the susceptibility pattern for a specific unit with respect to community-acquired, but not to hospital-acquired strains. Antibiograms adjusted to these parameters may be useful in guiding the choice of empirical antibacterial therapy.
Resumo:
Traditionally, studies dealing with muscle shortening have concentrated on assessing its impact on conduction velocity, and to this end, electrodes have been located between the end-plate and tendon regions. Possible morphologic changes in surface motor unit potentials (MUPs) as a result of muscle shortening have not, as yet, been evaluated or characterized. Using a convolutional MUP model, we investigated the effects of muscle shortening on the shape, amplitude, and duration characteristics of MUPs for different electrode positions relative to the fibre-tendon junction and for different depths of the MU in the muscle (MU-to-electrode distance). It was found that the effects of muscle shortening on MUP morphology depended not only on whether the electrodes were between the end-plate and the tendon junction or beyond the tendon junction, but also on the specific distance to this junction. When the electrodes lie between the end-plate and tendon junction, it was found that (1) the muscle shortening effect is not important for superficial MUs, (2) the sensitivity of MUP amplitude to muscle shortening increases with MU-to-electrode distance, and (3) the amplitude of the MUP negative phase is not affected by muscle shortening. This study provides a basis for the interpretation of the changes in MUP characteristics in experiments where both physiological and geometrical aspects of the muscle are varied.