257 resultados para Free distance
Resumo:
The authors developed a free-breathing black-blood coronary magnetic resonance (MR) angiographic technique with a potential for exclusive visualization of the coronary blood pool. Results with the MR angiographic technique were evaluated in eight healthy subjects and four patients with coronary disease identified at conventional angiography. This MR angiographic technique accurately depicted luminal disease in the patients and permitted visualization of extensive continuous segments of the native coronary tree in both the healthy subjects and the patients. Black-blood coronary MR angiography provides an alternative source of contrast enhancement.
Resumo:
BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.
Resumo:
OBJECTIVES: To evaluate morbidity associated with the radial forearm free flap donor site and to compare functional and aesthetic outcomes of ulnar-based transposition flap (UBTF) vs split-thickness skin graft (STSG) closure of the donor site.¦DESIGN: Case-control study.¦SETTING: Tertiary care institution.¦PATIENTS: The inclusion criteria were flap size not exceeding 30 cm(2), patient availability for a single follow-up visit, and performance of surgery at least 6 months previously. Forty-four patients were included in the study and were reviewed. Twenty-two patients had UBTF closure, and 22 had STSG closure.¦MAIN OUTCOME MEASURES: Variables analyzed included wrist mobility, Michigan Hand Outcomes Questionnaire scores, pinch and grip strength (using a dynamometer), and hand sensitivity (using monofilament testing over the radial nerve distribution). In analyses of operated arms vs nonoperated arms, variables obtained only for the operated arms included Vancouver Scar Scale scores and visual analog scale scores for Aesthetics and Overall Arm Function.¦RESULTS: The mean (SD) wrist extension was significantly better in the UBTF group (56.0° [10.4°] for nonoperated arms and 62.0° [9.7°] for operated arms) than in the STSG group (59.0° [7.1°] for nonoperated arms and 58.4° [12.1°] for operated arms) (P = .02). The improvement in wrist range of motion for the UBTF group approached statistical significance (P = .07). All other variables (Michigan Hand Outcomes Questionnaire scores, pinch and grip strength, hand sensitivity, and visual analog scale scores) were significantly better for nonoperated arms vs operated arms, but no significant differences were observed between the UBTF and STSG groups.¦CONCLUSIONS: The radial forearm free flap donor site carries significant morbidity. Donor site UBTF closure was associated with improved wrist extension and represents an alternative method of closure for small donor site defects.
Resumo:
OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.
Resumo:
Résumé: Les environnements hémodynamiques, favorisant ou protégeant contre la formation de la plaque, induisent tout deux une augmentation de la production d'anion superoxide dans les cellules endothéliales (ECs). Par ailleurs, une régulation différente de l'expression des gènes a été décrite dans les cellules exposées à ces différentes conditions. Dans le but d'investiguer le rôle de l'augmentation du stress oxydatif dans l'expression des gènes régulée par le flux, nous avons d'abord exposé les EC à un flux unidirectionnel, non pulsé. Dans ces conditions, l'état oxydatif des cellules endothéliales est augmenté de façon transitoire. L'expression du gène de l'endothéline 1 (ET-1) est aussi induite de façon transitoire par un tel flux, alors que l'expression du gène de la nitiric oxyde synthase endothéliale (NOS III) est stimulé de façon durable. Au contraire, un flux unidirectionnel pulsé, qui induit une augmentation durable de la production d'anion superoxide, augmente aussi de façon durable l'expression des gènes de ET-1 comme de NOS III. Un flux oscillatoire (favorisant la plaque), qui lui aussi ,a des effets à long terme sur la production d'anion superoxide, a uniquement augmenté l'expression de ET-1. De plus, l'utilisation d'un antioxydant, a seulement partiellement inhibé la stimulation de l'expression du gène NOS III par le flux unidirectionnel pulsé, alors qu'il a complètement abrogé la stimulation de l'expression du gène ET-1 par le flux unidirectionnel pulsé et oscillatoire. Ceci suggère que les forces mécaniques régulent l'expression des gènes dans les EC par un double mécanisme dépendant et indépendant du stress oxidatif des cellules. Par ailleurs, ces résultats supportent ultérieurement l'hypothèse que la balance entre la réponse oxidative et anti-oxidante dans les cellules endothéliales exposées à un environnement hémodynamique est une des clés de la prédisposition à un dysfonctionnement endothélial observé dans des régions exposées à des flux perturbés. Abstract: Both plaque-free and plaque-prone hemodynamic environments induce an increase in the oxidative state of endothelial cells (ECs), whereas differential gene expression regulation was described in cells exposed to these conditions. In order to investigate the role of the increased oxidative state in flow-regulation of gene expression, we first exposed EC to non-pulsed unidirectional shear stress. These conditions only slightly increases ECs oxidative state and endothelin-1 (ET-1) mRNA expression, whereas endothelial nitric oxide synthase (NOS III) mRNA level were significantly up-regulated. On the contrary, both ET-1 and NOS III gene expression were significantly induced in EC exposed to pulsed-unidirectional flow (plaque-free). Only ET-1 gene expression was up-regulated by oscillatory flow (plaque-prone). Moreover, use of an antioxidant only partially inhibited NOS III gene up-regulation by unidirectional flow, whereas it completely abrogated ET-1 gene up-regulation by unidirectional and oscillatory flows. Thus suggesting that mechanical forces regulate gene expression in ECs both via oxidative stress-dependent and -independent mechanisms.
Resumo:
BACKGROUND: We investigated whether the free β-human chorionic gonadotropin (free β-hCG) would provide additional information to that provided by total hCG alone and thus be useful in future epidemiological studies relating hCG to maternal breast cancer risk. MATERIALS & METHODS: Cases (n = 159) and controls (n = 286) were a subset of our previous study within the Northern Sweden Maternity Cohort on total hCG during primiparous pregnancy and breast cancer risk. RESULTS: The associations between total hCG (hazard ratio: 0.79; 95% CI: 0.49-1.27), free β-hCG (hazard ratio: 0.85; 95% CI: 0.33-2.18) and maternal risk of breast cancer were very similar in all analyses and mutual adjustment for either one had minor effects on the risk estimates. CONCLUSION: In the absence of a reliable assay on intact hCG, total hCG alone can be used in epidemiological studies investigating hCG and breast cancer risk, as free β-hCG does not appear to provide any additional information.
Resumo:
A cutaneous horn was observed close to the free margin of the inferior right eyelid in a 26-year-old-male patient. A minimal resection was primarily performed. Histopathologic study disclosed a precancerous keratosis. As the tumor had not been entirely excised, a complementary resection was performed secondarily to obtain the entire resection of the tumor.
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.
Resumo:
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.
Resumo:
BACKGROUND: Microvascular decompression (MVD) is the reference technique for pharmacoresistant trigeminal neuralgia (TN). OBJECTIVE: To establish whether the safety and efficacy of Gamma Knife surgery for recurrent TN are influenced by prior MVD. METHODS: Between July 1992 and November 2010, 54 of 737 patients (45 of 497 with >1 year of follow-up) had a history of MVD (approximately half also with previous ablative procedure) and were operated on with Gamma Knife surgery for TN in the Timone University Hospital. A single 4-mm isocenter was positioned in the cisternal portion of the trigeminal nerve at a median distance of 7.6 mm (range, 3.9-11.9 mm) anterior to the emergence of the nerve. A median maximum dose of 85 Gy (range, 70-90 Gy) was delivered. RESULTS: The median follow-up time was 39.5 months (range, 14.1-144.6 months). Thirty-five patients (77.8%) were initially pain free in a median time of 14 days (range, 0-180 days), much lower compared with our global population of classic TN (P = .01). Their actuarial probabilities of remaining pain-free without medication at 3, 5, 7, and 10 years were 66.5%, 59.1%, 59.1%, and 44.3%. The hypoesthesia actuarial rate at 1 year was 9.1% and remained stable until 12 years (median, 8 months). CONCLUSION: Patients with previous MVD showed a significantly lower probability of initial pain cessation compared with our global population with classic TN (P = .01). The toxicity was low (only 9.1% hypoesthesia); furthermore, no patient reported bothersome hypoesthesia. However, the probability of maintaining pain relief without medication was 44.3% at 10 years, similar to our global series of classic TN (P = .85). ABBREVIATIONS: BNI, Barrow Neurological InstituteCI, confidence intervalCTN, classic trigeminal neuralgiaGKS, Gamma Knife surgeryHR, hazard ratioMVD, microvascular decompressionTN, trigeminal neuralgia.
Resumo:
Peroxisome proliferator-activated receptor alpha (PPARalpha) is an important transcription factor in liver that can be activated physiologically by fasting or pharmacologically by using high-affinity synthetic agonists. Here we initially set out to elucidate the similarities in gene induction between Wy14643 and fasting. Numerous genes were commonly regulated in liver between the two treatments, including many classical PPARalpha target genes, such as Aldh3a2 and Cpt2. Remarkably, several genes induced by Wy14643 were upregulated by fasting independently of PPARalpha, including Lpin2 and St3gal5, suggesting involvement of another transcription factor. Using chromatin immunoprecipitation, Lpin2 and St3gal5 were shown to be direct targets of PPARbeta/delta during fasting, whereas Aldh3a2 and Cpt2 were exclusive targets of PPARalpha. Binding of PPARbeta/delta to the Lpin2 and St3gal5 genes followed the plasma free fatty acid (FFA) concentration, consistent with activation of PPARbeta/delta by plasma FFAs. Subsequent experiments using transgenic and knockout mice for Angptl4, a potent stimulant of adipose tissue lipolysis, confirmed the stimulatory effect of plasma FFAs on Lpin2 and St3gal5 expression levels via PPARbeta/delta. In contrast, the data did not support activation of PPARalpha by plasma FFAs. The results identify Lpin2 and St3gal5 as novel PPARbeta/delta target genes and show that upregulation of gene expression by PPARbeta/delta is sensitive to plasma FFA levels. In contrast, this is not the case for PPARalpha, revealing a novel mechanism for functional differentiation between PPARs.