223 resultados para Carotid endarterectomy, carotid stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We carried out a retrospective review of 155 patients with lumbar spinal stenosis who had been treated surgically and followed up regularly: 77 were evaluated at a mean of 6.5 years (5 to 8) after surgery by two independent observers. The outcome was assessed using the scoring system of Roland and Morris, and the rating system of Prolo, Oklund and Butcher. Instability was determined according to the criteria described by White and Panjabi. A significant decrease in low back pain and disability was seen. An excellent or good outcome was noted in 79% of patients; 9% showed secondary radiological instability. Surgical decompression is a safe and efficient procedure. In the absence of preoperative radiological evidence of instability, fusion is not required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In endoscopic sinus surgery, knowledge of the course of the internal ethmoida and orbital arteries is crucial.The maxillary and the internal carotid arteries of cadavers were injected with radio-opaque , red colorede silicone. The ethmoidal regions were perpared and plastinated using the standard S10 technique. On some specimens, the ophtalmic and ethmoidal arteries were dissected prior to plastination. The plastinated specimens of the ethmoidal blocks were successfullyintroduced into clinical teaching of sinus anatomy and surgery as an aid to study vaascularization an dits relationship to surgical procedures. Among the advantages of this method are the long-lasting preservation of dissected tissue, visualization of arteries during endoscopic and radiological examinations, and invaluable teachjing and training resources for endoscopic sinus surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Measures of the degree of lumbar spinal stenosis (LSS) such as antero-posterior diameter of the canal, and dural sac cross sectional area vary, and do not correlate with symptoms or results of surgery. We created a grading system, comprised of seven categories, based on the morphology of the dural sac and its contents as seen on T2 axial images. The categories take into account the ratio of rootlet/ CSF content. Grade A indicates no significant compression, grade D is equivalent to a total myelograhic block. We compared this classification with commonly used criteria of severity of stenosis. Methods: Fifty T2 axial MRI images taken at disc level from 27 symptomatic LSS patients undergoing decompressive surgery were classified twice by two radiologists and three spinal surgeons working at different institutions and countries. Dural sac cross-sectional surface area and AP diameter of the canal were measured both at disc and pedicle level from DICOM images using OsiriX software. Intraand inter-observer reliability were assessed using Cohen's, Fleiss' kappa statistics, and t test. Results: For the morphological grading the average intra-and inter observer kappas were 0.76 and 0.69+, respectively, for physicians working in the study originating country. Combining all observers the kappa values were 0.57 ± 0.19. and 0.44 ± 0.19, respectively. AP diameter and dural sac cross-sectional area measurements showed no statistically significant differences between observers. No correlation between morphological grading and AP diameter or dural sac crosssectional areawas observed in 13 (26%) and 8 cases (16%), respectively. Discussion: The proposed morphological grading relies on the identification of the dural sac and CSF better seen on full MRI series. This was not available to the external observers, which might explain the lower overall kappa values. Since no specific measurement tools are needed the grading suits everyday clinical practice and favours communication of degree of stenosis between practising physicians. The absence of a strict correlation with the dural sac surface suggests that measuring the surface alone might be insufficient in defining LSS as it is essentially a mismatch between the spinal canal and its contents. This grading is now adopted in our unit and further studies concentrating on relation between morphology, clinical symptoms and surgical results are underway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Lumbar spinal stenosis (LSS) treatment is based primarily on the clinical criteria providing that imaging confirms radiological stenosis. The radiological measurement more commonly used is the dural sac cross-sectional area (DSCA). It has been recently shown that grading stenosis based on the morphology of the dural sac as seen on axial T2 MRI images, better reflects severity of stenosis than DSCA and is of prognostic value. This radiological prospective study investigates the variability of surface measurements and morphological grading of stenosis for varying degrees of angulation of the T2 axial images relative to the disc space as observed in clinical practice. MATERIALS AND METHODS: Lumbar spine TSE T2 three-dimensional (3D) MRI sequences were obtained from 32 consecutive patients presenting with either suspected spinal stenosis or low back pain. Axial reconstructions using the OsiriX software at 0°, 10°, 20° and 30° relative to the disc space orientation were obtained for a total of 97 levels. For each level, DSCA was digitally measured and stenosis was graded according to the 4-point (A-D) morphological grading by two observers. RESULTS: A good interobserver agreement was found in grade evaluation of stenosis (k = 0.71). DSCA varied significantly as the slice orientation increased from 0° to +10°, +20° and +30° at each level examined (P < 0.0001) (-15 to +32% at 10°, -24 to +143% at 20° and -29 to +231% at 30° of slice orientation). Stenosis definition based on the surface measurements changed in 39 out of the 97 levels studied, whereas the morphology grade was modified only in two levels (P < 0.01). DISCUSSION: The need to obtain continuous slices using the classical 2D MRI acquisition technique entails often at least a 10° slice inclination relative to one of the studied discs. Even at this low angulation, we found a significantly statistical difference between surface changes and morphological grading change. In clinical practice, given the above findings, it might therefore not be necessary to align the axial cuts to each individual disc level which could be more time-consuming than obtaining a single series of axial cuts perpendicular to the middle of the lumbar spine or to the most stenotic level. In conclusion, morphological grading seems to offer an alternative means of assessing severity of spinal stenosis that is little affected by image acquisition technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif Evaluer l'évolution à long-terme d'une population de patients pédiatriques souffrant de sténose aortique congénitale et ayant subi une intervention chirurgicale sur cette valve, et déterminer les facteurs de risques associés à une ré-intervention. Patients et méthode De 1985 à 2009, 77 patients, en moyenne âgés de 5.8 ± 5-6 ans, ont été suivis dans notre Service durant 14.8 ± 9-1 années. Résultats La première intervention montre d'excellents résultats avec 86% des patients ayant un gradient aortique résiduel < 50 mmHg et seulement 7% avec une nouvelle fuite aortique >1. La survie à long terme est de 91% A 25 ans. A un intervalle de 7.6 ± 5-3 ans, 30 patients 011t nécessité une ré-intervention (39%), principalement à cause d'une récidive de la sténose aortique. Le pourcentage de patients libre de ré¬intervention était de 97, 89, 75, 53, and 42% à respectivement 1, 10,15, 20, et 25 ans. Les facteurs de risques cle ré-interventions étaient le gradient aortique residuel plus élevé (p=0.00 01), la fuite aortique post-intervention >1 (p=0.02), la valvuloplasty au ballon préalable (p-0.04) et l'épaisseur augmentée de la paroi postérieure du ventricule gauche (p=o.i). Conclusions L'intervention chirurgicale sur la valve aortique est un procédé sûr et efficace pour les sténoses aortiques congénitales et démontre d'excellents résultats au niveau de la survie. Cependant le taux de ré-intervention est élevé et influencé par le gradient aortique résiduel plus élevé, la fuite aortique post-intervention >1, la valvuloplasty au ballon préalable et l'épaisseur augmentée de la paroi postérieure du ventricule gauche. L'étude démontre qu'un suivi à long-terme est recommandé pour ces patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We examined whether making smokers aware that they had developed peripheral atherosclerosis would improve smoking cessation. METHODS: Smokers selected from the general population were randomly allocated to undergo high-resolution B-mode ultrasonography of their carotid and femoral arteries. All smokers received quit-smoking counseling. Smokers with > or =1 atherosclerotic plaque were given two photographs of a plaque with a relevant explanation. Quit rates were assessed by telephone 6 months later. RESULTS: Seventy-nine smokers did not undergo ultrasonography (A). Among the 74 smokers submitted to ultrasonography, 20 had no plaque (B) and 54 had > or =1 plaque (C). Quit rates were, respectively, 6.3, 5.0, and 22.2% in groups A, B, and C. Quit rates were higher in smokers submitted to ultrasonography (B + C vs A; P = 0.031) and in those receiving photographs (C vs A + B; P = 0.003). Smoking cessation was independently associated with intervention C (OR = 6.2; 95% CI = 1.8-21) and a white-collar job but not with age or gender. CONCLUSIONS: Providing smokers with photographs demonstrating atherosclerosis on their own person was an effective adjunct to physician's advice to quit smoking. Since ultrasonography is used increasingly often in clinical practice for cardiovascular risk stratification, this can provide an additional opportunity and means to deter smokers from smoking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Acute exposure to high altitude stimulates free radical formation in lowlanders, yet whether this persists during chronic exposure in healthy, well-adapted and maladapted highlanders suffering from chronic mountain sickness (CMS) remains to be established. METHODS: Oxidative-nitrosative stress (as determined by the presence of the biomarkers ascorbate radical [A •- ], via electron paramagnetic resonance spectroscopy, and nitrite [NO 2 2 ], via ozone-based chemiluminescence) was assessed in venous blood of 25 male highlanders in Bolivia living at 3,600 m with CMS (n 5 13, CMS 1 ) and without CMS (n 5 12, CMS 2 ). Twelve age- and activity-matched, healthy, male lowlanders were examined at sea level and during acute hypoxia. We also measured fl ow-mediated dilatation (FMD), arterial stiffness defined by augmentation index normalized for a heart rate of 75 beats/min (AIx-75), and carotid intima-media thickness (IMT). RESULTS: Compared with normoxic lowlanders, oxidative-nitrosative stress was moderately increased in the CMS 2 group ( P , .05), as indicated by elevated A •- (3,191 457 arbitrary units [AU] vs 2,640 445 AU) and lower NO 2 2 (206 55 nM vs 420 128 nM), whereas vascular function remained preserved. This was comparable to that observed during acute hypoxia in lowlanders in whom vascular dysfunction is typically observed. In contrast, this response was markedly exaggerated in CMS 1 group (A •- , 3,765 429 AU; NO 2 2 , 148 50 nM) compared with both the CMS 2 group and lowlanders ( P , .05). This was associated with systemic vascular dysfunction as indicated by lower ( P , .05 vs CMS 2 ) FMD (4.2% 0.7% vs 7.6% 1.7%) and increased AIx-75 (23% 8% vs 12% 7%) and carotid IMT (714 127 m M vs 588 94 m M). CONCLUSIONS: Healthy highlanders display a moderate, sustained elevation in oxidative-nitrosative stress that, unlike the equivalent increase evoked by acute hypoxia in healthy lowlanders, failed to affect vascular function. Its more marked elevation in patients with CMS may contribute to systemic vascular dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although gravity drainage has been the standard technique for cardiopulmonary bypass (CPB), the development of min imally invasive techniques for cardiac surgery has renewed interest in using vacuum assisted venous drainage (VAVD) Dideco (Mirandola, Italy) has modified the D903 Avant oxygenator to apply a vacuum to its venous reservoir. The impact of VAVD on blood damage with this device is analyzed. Six calves (mean body weight, 71.3 +/- 4.1 kg) were con nected to CPB by jugular venous and carotid arterial cannu lation, with a flow rate of 4-4.51 L/min for 6 h. They were assigned to gravity drainage (standard D903 Avant oxygen ator, n = 3) or VAVD (modified D903 Avant oxygenator, n = 3). The animals were allowed to survive for 7 days. A standard battery of blood samples was taken before bypass, throughout bypass, and 24 h, 48 h, and 7 days after bypass. Analysis of variance was used for repeated measurements. Thrombocyte and white blood cell counts, corrected by hematocrit and normalized by prebypass values, were not significantly different between groups throughout all study periods. The same holds true for hemolytic parameters (lactate dehydrogenase [LDH] and plasma hemoglobin). Both peaked at 24 hr in the standard and VAVD groups: LDH, 2,845 +/- 974 IU/L vs. 2,537 +/- 476 IU/L (p = 0.65), respectively; and plasma hemoglobin, 115 +/- 31 mg/L vs. 89 +/- 455 mg/L (p = 0.45), respectively. In this experimental setup with prolonged perfusion time, VAVD does not increase trauma to blood cells in comparison with standard gravity drainage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical decision-making in lumbar spinal stenosis involves assessment of clinical parameters and the severity of the radiological stenosis. We suspected that surgeons based surgical decisions more on dural sac cross-sectional area (DSCA) than on the morphology of the dural sac. We carried out a survey among members of three European spine societies. The axial T2-weighted MR images from ten patients with varying degrees of DSCA and morphological grades according to the recently described morphological classification of lumbar spinal stenosis, with DSCA values disclosed in half the assessed images, were used for evaluation. We provided a clinical scenario to accompany the images, which were shown to 142 responding physicians, mainly orthopaedic surgeons but also some neurosurgeons and others directly involved in treating patients with spinal disorders. As the primary outcome we used the number of respondents who would proceed to surgery for a given DSCA or morphological grade. Substantial agreement among the respondents was observed, with severe or extreme stenosis as defined by the morphological grade leading to surgery. This decision was not dependent on the number of years in practice, medical density or specialty. Disclosing the DSCA did not alter operative decision-making. In all, 40 respondents (29%) had prior knowledge of the morphological grading system, but their responses showed no difference from those who had not. This study suggests that the participants were less influenced by DSCA than by the morphological appearance of the dural sac. Classifying lumbar spinal stenosis according to morphology rather than surface measurements appears to be consistent with current clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esophageal intramural pseudodiverticulosis is a rare pathology whose etiology is unknown, but which is frequently associated with three highly prevalent entities: esophageal reflux disease, esophageal candidosis and alcoholic esophagitis. With conservative treatment the course of these pathologies is usually benign. However, some severe cases are resistant to conservative treatment and may require more aggressive management. We here present the case of patient suffering from a severe esophagitis complicated by chronic mediastinitis with life-threatening repercussions, requiring esophagectomy as treatment.