297 resultados para CT colonography (virtual colonoscopy)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The quality of colon cleansing is a major determinant of quality of colonoscopy. To our knowledge, the impact of bowel preparation on the quality of colonoscopy has not been assessed prospectively in a large multicenter study. Therefore, this study assessed the factors that determine colon-cleansing quality and the impact of cleansing quality on the technical performance and diagnostic yield of colonoscopy. METHODS: Twenty-one centers from 11 countries participated in this prospective observational study. Colon-cleansing quality was assessed on a 5-point scale and was categorized on 3 levels. The clinical indication for colonoscopy, diagnoses, and technical parameters related to colonoscopy were recorded. RESULTS: A total of 5832 patients were included in the study (48.7% men, mean age 57.6 [15.9] years). Cleansing quality was lower in elderly patients and in patients in the hospital. Procedures in poorly prepared patients were longer, more difficult, and more often incomplete. The detection of polyps of any size depended on cleansing quality: odds ratio (OR) 1.73: 95% confidence interval (CI)[1.28, 2.36] for intermediate-quality compared with low-quality preparation; and OR 1.46: 95% CI[1.11, 1.93] for high-quality compared with low-quality preparation. For polyps >10 mm in size, corresponding ORs were 1.0 for low-quality cleansing, OR 1.83: 95% CI[1.11, 3.05] for intermediate-quality cleansing, and OR 1.72: 95% CI[1.11, 2.67] for high-quality cleansing. Cancers were not detected less frequently in the case of poor preparation. CONCLUSIONS: Cleansing quality critically determines quality, difficulty, speed, and completeness of colonoscopy, and is lower in hospitalized patients and patients with higher levels of comorbid conditions. The proportion of patients who undergo polypectomy increases with higher cleansing quality, whereas colon cancer detection does not seem to critically depend on the quality of bowel preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the dual-energy CT behavior of cocaine and heroin and of typical adulterants, and to evaluate the elemental composition of pure cocaine and heroin compared with cocaine and heroin in bodypacks. METHODS: Pure heroin and pure synthetic cocaine samples, eight different adulterants, and in each case ten different bodypacks containing cocaine or heroin, were imaged at 80, 100, 120, and 140 kVp in a dual source CT system at two different degrees of compression. Two radiologists, blinded to the samples, measured the attenuation. The dual-energy index (DEI) was calculated. We performed atomic mass spectrometry for the elemental analysis of pure cocaine, pure heroin, and heroin and cocaine in bodypacks, and 140 kVp in a dual-source CT system. RESULTS: Inter- and intra-observer agreement for attenuation measurements was good (r = 0.61-0.72; p < 0.01). The cocaine bodypacks had a positive DEI of 0.029, while the pure drugs and the heroin bodypacks had a negative DEI (-0.051 to -0.027). Levamisole was the only substance which expressed a positive DEI of 0.011, while the remaining adulterants had negative DEIs ranging between -0.015 and -0.215. Atomic mass spectrometry revealed a concentration of tin in the cocaine bodypack that was 67 times higher than in the pure synthetic cocaine sample. CONCLUSIONS: The different DEIs of bodypacks containing cocaine and heroin allow them to be distinguished with dual-energy CT. Although the material properties of pure cocaine, pure heroin, or common drug extenders do not explain the differences in DEI, tin contamination during illicit natural cocaine production may be a possible explanation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Diagnostik des plötzlichen Herztods durch bildgebende Techniken ist bislang unzureichend evaluiert. Als Validierungsoption für postmortale koronarangiographische Methoden steht der Sektionsbefund zur Verfügung. Sequenziell postmortal durchgeführte alternative angiographische Methoden sind denkbar. Schließlich bietet die ante mortem durchgeführte Koronarangiographie (CA) - ggf. In Verbindung mit der perkutanen transluminalen Koronarangioplastie (PTCA) - weitere Vergleichsmöglichkeiten. Neben deskriptiven sind hier auch potenziell funktionelle Aussagen zum Stenosegrad möglich.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: "Virtual" autopsy by postmortem computed tomography (PMCT) can replace medical autopsy to a certain extent but has limitations for cardiovascular diseases. These limitations might be overcome by adding multiphase PMCT angiography. OBJECTIVE: To compare virtual autopsy by multiphase PMCT angiography with medical autopsy. DESIGN: Prospective cohort study. (ClinicalTrials.gov: NCT01541995) SETTING: Single-center study at the University Medical Center Hamburg-Eppendorf, Hamburg, Germany, between 1 April 2012 and 31 March 2013. PATIENTS: Hospitalized patients who died unexpectedly or within 48 hours of an event necessitating cardiopulmonary resuscitation. MEASUREMENTS: Diagnoses from clinical records were compared with findings from both types of autopsy. New diagnoses identified by autopsy were classified as major or minor, depending on whether they would have altered clinical management. RESULTS: Of 143 eligible patients, 50 (35%) had virtual and medical autopsy. Virtual autopsy confirmed 93% of all 336 diagnoses identified from antemortem medical records, and medical autopsy confirmed 80%. In addition, virtual and medical autopsy identified 16 new major and 238 new minor diagnoses. Seventy-three of the virtual autopsy diagnoses, including 32 cases of coronary artery stenosis, were identified solely by multiphase PMCT angiography. Of the 114 clinical diagnoses classified as cardiovascular, 110 were confirmed by virtual autopsy and 107 by medical autopsy. In 11 cases, multiphase PMCT angiography showed "unspecific filling defects," which were not reported by medical autopsy. LIMITATION: These results come from a single center with concerted interest and expertise in postmortem imaging; further studies are thus needed for generalization. CONCLUSION: In cases of unexpected death, the addition of multiphase PMCT angiography increases the value of virtual autopsy, making it a feasible alternative for quality control and identification of diagnoses traditionally made by medical autopsy. PRIMARY FUNDING SOURCE: University Medical Center Hamburg-Eppendorf.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Virtual reality (VR) simulators are widely used to familiarize surgical novices with laparoscopy, but VR training methods differ in efficacy. In the present trial, self-controlled basic VR training (SC-training) was tested against training based on peer-group-derived benchmarks (PGD-training). METHODS: First, novice laparoscopic residents were randomized into a SC group (n = 34), and a group using PGD-benchmarks (n = 34) for basic laparoscopic training. After completing basic training, both groups performed 60 VR laparoscopic cholecystectomies for performance analysis. Primary endpoints were simulator metrics; secondary endpoints were program adherence, trainee motivation, and training efficacy. RESULTS: Altogether, 66 residents completed basic training, and 3,837 of 3,960 (96.8 %) cholecystectomies were available for analysis. Course adherence was good, with only two dropouts, both in the SC-group. The PGD-group spent more time and repetitions in basic training until the benchmarks were reached and subsequently showed better performance in the readout cholecystectomies: Median time (gallbladder extraction) showed significant differences of 520 s (IQR 354-738 s) in SC-training versus 390 s (IQR 278-536 s) in the PGD-group (p < 0.001) and 215 s (IQR 175-276 s) in experts, respectively. Path length of the right instrument also showed significant differences, again with the PGD-training group being more efficient. CONCLUSIONS: Basic VR laparoscopic training based on PGD benchmarks with external assessment is superior to SC training, resulting in higher trainee motivation and better performance in simulated laparoscopic cholecystectomies. We recommend such a basic course based on PGD benchmarks before advancing to more elaborate VR training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is, aside skin cancer, the most common malignancy occurring after solid organ transplant in adults. Fluorodeoxyglucose (FDG) positron emission tomography (PET) has proved useful in the management of lymphomas. METHODS: We report our experience with the use of FDG-PET inline with computed tomography (CT) scanning in the management of four transplant recipients with histologically confirmed PTLD, including three monomorphic PTLDs and one polymorphic PTLD. RESULTS: FDG-PET/CT scan at diagnosis showed increased FDG uptake in all examined PTLD lesions, and the disease was upstaged on the basis of FDG-PET/CT scan results over conventional CT scanning in one patient. At the end of treatment, PET/CT scans no longer demonstrated FDG uptake in the original PTLD lesions in all patients. Complete remission of disease persisted for at least 1 year after diagnosis in all. CONCLUSIONS: Our results strongly support that FDG-PET scanning is highly specific for diagnosis and follow-up of PTLD. The clinical relevance of including FDG-PET/CT scanning in the management of PTLD should be evaluated in a larger prospective cohort study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background¦Erythrocyte MCV might be used as an inexpensive marker to predict and¦optimize the efficacy and tolerability of thiopurine therapy in IBD patients.¦Aim and methods¦This retrospective observational study aimed to assess the monitoring¦performances of MCV in patients under 3 months or more thiopurine treatment followed up¦in the Swiss IBD Cohort Study. All available MCV, white blood cells (WBC) and 6¦thioguanine nucleotide (6TGN) measurements, among others, were recorded. An IBD¦"flare" was defined as a composite outcome encompassing treatment change,¦colonoscopy, histology, CT scan or MRI reports showing active IBD lesions, occurrence of¦intestinal surgery and IBD-related hospitalisations. Whether MCV measurements predicted¦efficacy of thiopurine treatment was investigated by assessing the statistical association¦between the occurrence of IBD "flares", and the current or recent MCV values, taking into¦account the patient clustering and longitudinal aspect of data.¦Results¦140 patients (77 women), mean age 38 years (17-74), 104 diagnosed with¦Crohn's disease, 36 with ulcerative colitis, mean disease duration 8 years (0.25-36),¦receiving either azathioprine (n=125) or 6-mercaptopurine (n=15) were included, most of¦them over 3-year follow up.¦Thiopurines increased mean patient MCV by an average 5.8±5.2 fL, while¦patientsfluctuated by ±4.3 fL around their individual mean (p<0.001). They decreased¦WBC by an average of 2.4+/- 2.6 G/L (p<0.001).¦Significant associations were observed between the probability of flare occurrence and low¦current MVC (p=0.017) or high current WBC (p=0.009) and, with a relative risk of 3.7% for¦every fL of MCV decrease or 8% for every G/L of WBC increase. Both markers revealed¦some memory effect.¦Despite this, the performance of MCV and WBC to predict IBD "flare" remained rather¦limited, as it is less accurate than the 6-TGN-level , although only determined in a¦subgroup of patients in this study.¦Conclusion¦MCV and WBC deserve to be observed to check and monitor therapeutic¦exposure to thiopurine agents in IBD patients. Unfortunately, their predictive performance¦precludes their privileged use for optimization of therapy. Further prospective studies¦should suitably include the systematic measurement of metabolite concentration.