159 resultados para BREATHING


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The arms race between predators and prey has led to morphological and behavioral adaptations. Different antipredator strategies can coexist within a population if each strategy is the result of a trade-off with competing demands. Antipredator behavior can be associated with morphological traits, like color patterns, either because in the context of sexual selection, coloration signals the ability to avoid predators or because coloration is a naturally selected trait useful in avoiding predators. Because in the barn owl (Tyto alba), heritable eumelanic plumage coloration is associated with the glucocorticoid-dependent response to stress, we tested whether antipredator behavior is also related to this trait. Compared with small-spotted nestlings, individuals displaying larger black spots hissed more intensely in the presence of humans, feigned death longer, had a lower breathing rate under stress, and were more docile when handled. Cross-fostering experiments showed that the covariation between the spot size and the duration of feigning death was inherited from the biological mother, whereas covariation between spot size and docility was inherited from the biological father. Our results confirm that melanin-based coloration is associated with suites of behavioral traits, which are under both genetic and environmental influence. Coloration can thus evolve as a direct or indirect response to predation, but it can also be a signal of antipredator strategies to potential mates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies have demonstrated that poultry house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at three different stages of the birds' growth; samples of air taken from within the breathing zones of individual poultry house employees as they caught the chickens ready to be transported for slaughter were also analysed. Quantitative polymerase chain reaction (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 26 +/- 1.9 mg m(-3) and endotoxin concentration was 6198 +/- 2.3 EU m(-3) air, >6-fold higher than the Swiss occupational recommended value (1000 EU m(-3)). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively, reaching values of 53 (+/-2.6) x 10(7) cells m(-3) air and 62 (+/-1.9) x 10(6) m(-3) air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: In the present study, the impact of the two different fat suppression techniques was investigated for free breathing 3D spiral coronary magnetic resonance angiography (MRA). As the coronary arteries are embedded in epicardial fat and are adjacent to myocardial tissue, magnetization preparation such as T(2)-preparation and fat suppression is essential for coronary discrimination. MATERIALS AND METHODS: Fat-signal suppression in three-dimensional (3D) thin- slab coronary MRA based on a spiral k-space data acquisition can either be achieved by signal pre-saturation using a spectrally selective inversion recovery pre-pulse or by spectral-spatial excitation. In the present study, the performance of the two different approaches was studied in healthy subjects. RESULTS: No significant objective or subjective difference was found between the two fat suppression approaches. CONCLUSION: Spectral pre-saturation seems preferred for coronary MRA applications due to the ease of implementation and the shorter cardiac acquisition window.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To assess the long-term outcome, safety, and efficacy of partial cricotracheal resection (PCTR) for subglottic stenosis in a group of children and infants weighing less than 10 kg at the time of the surgery. STUDY DESIGN: Historical cohort study. SETTING: Academic tertiary medical center. SUBJECTS AND METHODS: Thirty-six children weighing less than 10 kg at the time of the surgery were compared to a group of 65 children who weighed more than 10 kg. The Kaplan Meier method and Cox regression were carried out to detect differences in decannulation time and rates and to examine the influence of various parameters (i.e., comorbidities, type of surgery, and complications requiring revision surgery) at the time of decannulation. Evaluation of the long-term outcome was based on questionnaires assessing breathing, voice, and swallowing. RESULTS: Decannulation rate was 92 percent (33/36) for the group of children weighing less than 10 kg. No significant differences were found between the two body weight groups with respect to the aforementioned covariates. The median follow-up period was nine years (range, 1-23 yrs). Questionnaire responses revealed completely normal breathing and swallowing in 72 percent and 90 percent of the children, respectively. Seventy-one percent of the patients considered their voice to be rough or weak. CONCLUSION: PCTR in infants and children weighing less than 10 kg is a safe and efficient technique with similar long-term results when compared to results seen in older and heavier children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Research suggests that respiratory patterns may reflect general dimensions of emotional response. In this study, we investigated the relationships between judgments of affective valence (pleasantness) and arousal and respiratory responses to acoustic stimuli. Sixteen environmental noises and 16 musical fragments of 30 s duration were presented to 31 participants, while respiration, skin conductance level and heart rate were recorded. Judgments of valence and arousal were registered using the 9-point Self-Assessment Manikin. For noises, breathing accelerated and minute ventilation augmented with decreases in pleasantness for low-arousal stimuli and with increases in arousal for positive stimuli. For music, breathing accelerated and minute ventilation augmented with increases both in rated valence and arousal. Skin conductance level increased with arousal ratings for music but not for noises, whereas mean heart rate increased with rated arousal for noises but not for music. Although both noises and music are sound-vibrations, differences in the relationships between affective judgments and physiological responses were found suggesting differences in the processing of the two types of acoustic stimuli. [Authors]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Descriptors: music performance anxiety, respiration, hyperventilation Surveys indicate that high-anxious musicians may suffer from hyperventilation (HV) before or during performance. Reported symptoms include shortness of breath, fast/ deep breathing and thumping heart. However, no study has yet tested if these selfreported symptoms reflect actual cardiorespiratory activity. Themain goal of this study was to determine if MPA is manifested physiologically in specific correlates of cardiorespiratory activity associated with HV.We studied 74 professional music students from Swiss Music Academies. In this study, we compared the most anxious students (highanxious; n 5 20) with the least anxious students (low-anxious; n 5 23) based on their self-reported performance anxiety. We measured cardiorespiratory patterns with the Lifeshirt system, end-tidal CO2 with a capnograph (EtCO2, a good non-invasive estimator of HV), self-perceived physiological activation and affective experience in three situations on different days: baseline, performance without audience, and performance with audience. Comparing measures for the private vs. the public concert, high- compared to low-anxious students showed a significant drop in EtCO2 before the public concert and reported larger increases in anxiety, tension, palpitations and breathing difficulties. In contrast, heart rate, respiratory rate and volume did not differ significantly between groups. The results of this study support the hypothesis thatMPA may be associated with a tendency to hyperventilate and, thus, point to a potential hyperventilation problem in high-anxious music students.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cet article présente les résultats de la revue systématique: Yang M, Yan Y, Yin X, et al. Chest physiotherapy for pneumonia in adults. Cochrane Database of Systematic Reviews 2010, Issue 2. Art. No.: CD006338. DOI: 10.1002/14651858.CD006338.pub2. PMID: 20166082.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capsule Boldness defines the extent to which animals are willing to take risks in the presence of a predator. Late, but not early, in the breeding season, Israeli nestling Barn Owls displaying larger black feather spots were more docile, feigned death longer and had a lower breathing rate when handled than smaller-spotted nestlings. Larger-spotted breeding females were less docile if heavy but more more docile if light. The covariation between personality (boldness vs. timid) and melanin-based colouration is therefore conditional on environmental factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate the impact of in-plane coronary artery motion on coronary magnetic resonance angiography (MRA) and coronary MR vessel wall imaging. Free-breathing, navigator-gated, 3D-segmented k-space turbo field echo ((TFE)/echo-planar imaging (EPI)) coronary MRA and 2D fast spin-echo coronary vessel wall imaging of the right coronary artery (RCA) were performed in 15 healthy adult subjects. Images were acquired at two different diastolic time periods in each subject: 1) during a subject-specific diastasis period (in-plane velocity <4 cm/second) identified from analysis of in-plane coronary artery motion, and 2) using a diastolic trigger delay based on a previously implemented heart-rate-dependent empirical formula. RCA vessel wall imaging was only feasible with subject-specific middiastolic acquisition, while the coronary wall could not be identified with the heart-rate-dependent formula. For coronary MRA, RCA border definition was improved by 13% (P < 0.001) with the use of subject-specific trigger delay (vs. heart-rate-dependent delay). Subject-specific middiastolic image acquisition improves 3D TFE/EPI coronary MRA, and is critical for RCA vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While 3D thin-slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k-space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k-space gradient-echo and spiral k-space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T(2) preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R-R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) (both P < 0.001) and image quality. The single spiral per R-R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6-fold increase in SNR. The double-interleaf spiral approach showed a 50% reduction in scanning time, a 1.8-fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be "traded" for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare volume-targeted and whole-heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. MATERIALS AND METHODS: Six healthy adult subjects underwent a navigator-gated and -corrected (NAV) free breathing volume-targeted cardiac-triggered inversion recovery (IR) 3D steady-state free precession (SSFP) coronary MRA sequence (t-CMRA) (spatial resolution = 1 x 1 x 3 mm(3)) and high spatial resolution IR 3D SSFP whole-heart coronary MRA (WH-CMRA) (spatial resolution = 1 x 1 x 2 mm(3)) after the administration of an intravascular contrast agent B-22956. Subjective and objective image quality parameters including maximal visible vessel length, vessel sharpness, and visibility of coronary side branches were evaluated for both t-CMRA and WH-CMRA. RESULTS: No significant differences (P = NS) in image quality were observed between contrast-enhanced t-CMRA and WH-CMRA. However, using an intravascular contrast agent, significantly longer vessel segments were measured on WH-CMRA vs. t-CMRA (right coronary artery [RCA] 13.5 +/- 0.7 cm vs. 12.5 +/- 0.2 cm; P < 0.05; and left circumflex coronary artery [LCX] 11.9 +/- 2.2 cm vs. 6.9 +/- 2.4 cm; P < 0.05). Significantly more side branches (13.3 +/- 1.2 vs. 8.7 +/- 1.2; P < 0.05) were visible for the left anterior descending coronary artery (LAD) on WH-CMRA vs. t-CMRA. Scanning time and navigator efficiency were similar for both techniques (t-CMRA: 6.05 min; 49% vs. WH-CMRA: 5.51 min; 54%, both P = NS). CONCLUSION: Both WH-CMRA and t-CMRA using SSFP are useful techniques for coronary MRA after the injection of an intravascular blood-pool agent. However, the vessel conspicuity for high spatial resolution WH-CMRA is not inferior to t-CMRA, while visible vessel length and the number of visible smaller-diameter vessels and side-branches are improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. MATERIALS AND METHODS: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 +/- 5.0; SNR ao: 37.6 +/- 8.4; CNR coro-fat: 25.3 +/- 4.5; LAD: 128.0 cm +/- 8.8; RCA: 74.6 cm +/- 12.4; Sharpness: 66.6 % +/- 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 +/- 3.8; SNR ao: 33.8 +/- 11.4; CNR coro-fat: 19.9 +/- 3.3; LAD: 112.5 cm +/- 13.8; RCA: 69.6 cm +/- 16.6; Sharpness: 58.9 % +/- 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. CONCLUSION: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.