173 resultados para thermal lens technique.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
L' évaluation quantitative des dangers et des expositions aux nanomatériaux se heurte à de nombreuses incertitudes qui ne seront levées qu'à mesure de la progression des connaissances scientifiques de leurs propriétés. L' une des conséquences de ces incertitudes est que les valeurs limites d'exposition professionnelle définies actuellement pour les poussières ne sont pas nécessairement pertinentes aux nanomatériaux. En l'absence de référentiel quantitatif et, à la demande de la DGS pour éclairer les réflexions de l' AFNOR et de l'ISO sur le sujet, une démarche de gestion graduée des risques (control banding) a été élaborée au sein de l' Anses. Ce développement a été réalisé à l'aide d'un groupe d'experts rapporteurs rattaché au Comité d'experts spécialisés évaluation des risques liés aux agents physiques, aux nouvelles technologies et aux grands aménagements. La mise en oeuvre de la démarche de gestion graduée des risques proposée repose sur quatre grandes étapes: 1. Le recueil des informations. Cette étape consiste à réunir les informations disponibles sur les dangers du nanomatériau manufacturé considéré ; ainsi que sur l'exposition potentielle des personnes aux postes de travail (observation sur le terrain, mesures, etc.). 2. L'attribution d'une bande de danger. Le danger potentiel du nanomatériau manufacturé présent, qu'il soit brut où incorporé dans une matrice (liquide ou solide) est évalué dans cette étape. La bande danger attribuée tient compte de la dangerosité du produit bulk ou de sa substance analogue à l'échelle non-nanométrique, de la bio-persistance du matériau (pour les matériaux fibreux), de sa solubilité et de son éventuelle réactivité. 3. Attribution d'une bande d'exposition. La bande d'exposition du nanomatériau manufacturé considéré ou du produit en contenant est définie par le niveau de potentiel d'émission du produit. Elle tient compte de sa forme physique (solide, liquide, poudre aérosol), de sa pulvérulence et de sa volatilité. Le nombre de travailleurs, la fréquence, la durée d'exposition ainsi que la quantité mise en oeuvre ne sont pas pris en compte, contrairement à une évaluation classique des risques chimiques. 4. Obtention d'une bande de maîtrise des risques. Le croisement des bandes de dangers et d'exposition préalablement attribuées permet de défi nir le niveau de maîtrise du risque. Il fait correspondre les moyens techniques et organisationnels à mettre en oeuvre pour maintenir le risque au niveau le plus faible possible. Un plan d'action est ensuite défi ni pour garantir l'effi cacité de la prévention recommandée par le niveau de maîtrise déterminé. Il tient compte des mesures de prévention déjà existantes et les renforce si nécessaire. Si les mesures indiquées par le niveau de maîtrise de risque ne sont pas réalisables, par exemple, pour des raisons techniques ou budgétaires, une évaluation de risque approfondie devra être réalisée par un expert. La gestion graduée des risques est une méthode alternative pour réaliser une évaluation qualitative de risques et mettre en place des moyens de prévention sans recourir à une évaluation quantitative des risques. Son utilisation semble particulièrement adaptée au contexte des nanomatériaux manufacturés, pour lequel les choix de valeurs de référence (Valeurs limites d'exposition en milieu professionnel) et des techniques de mesurage appropriées souffrent d'une grande incertitude. La démarche proposée repose sur des critères simples, accessibles dans la littérature scientifi que ou via les données techniques relatives aux produits utilisés. Pour autant, sa mise en oeuvre requiert des compétences minimales dans les domaines de la prévention des risques chimiques (chimie, toxicologie, etc.), des nanosciences et des nanotechnologies.
Resumo:
Cerebral blood flow can be studied in a multislice mode with a recently proposed perfusion sequence using inversion of water spins as an endogenous tracer without magnetization transfer artifacts. The magnetization transfer insensitive labeling technique (TILT) has been used for mapping blood flow changes at a microvascular level under motor activation in a multislice mode. In TILT, perfusion mapping is achieved by subtraction of a perfusion-sensitized image from a control image. Perfusion weighting is accomplished by proximal blood labeling using two 90 degrees radiofrequency excitation pulses. For control preparation the labeling pulses are modified such that they have no net effect on blood water magnetization. The percentage of blood flow change, as well as its spatial extent, has been studied in single and multislice modes with varying delays between labeling and imaging. The average perfusion signal change due to activation was 36.9 +/- 9.1% in the single-slice experiments and 38.1 +/- 7.9% in the multislice experiments. The volume of activated brain areas amounted to 1.51 +/- 0.95 cm3 in the contralateral primary motor (M1) area, 0.90 +/- 0.72 cc in the ipsilateral M1 area, 1.27 +/- 0.39 cm3 in the contralateral and 1.42 +/- 0.75 cm3 in the ipsilateral premotor areas, and 0.71 +/- 0.19 cm3 in the supplementary motor area.
Resumo:
Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.
Resumo:
Objectifs: Evaluer la faisabilité, les résultats préliminaires à court et long terme du vissage percutané de vissage trans -isthmique sous anesthésie locale et contrôle scannerdes lyses isthmiques de bas grades.Matériels et méthodes: Etude prospective monocentrique réalisée sur 10 patients ayant une lyse isthmique grade 1 et 2 résistant au traitement médical conventionnel. Une évaluationclinique était réalisée à un mois, 3 mois, 6 mois et un an post-opératoire par un évaluateur indépendant. L'indication est posée en concertation avec le service dechirurgie orthopédique.Résultats: Les lyses isthmiques étaient situées en L5-S1 avec 6 grades 1 et 4 grades 2. L'échelle analogique de la douleur (VAS) variait de 6 a 9 avec une moyenne de 7,8.L'indication opératoire chirurgicale était posée pour tous les patients par arthrodèse postérieure lombo -sacree. Pour chaque patient 2 vis étaient positionnées soitun total de 20 vis. Un suivi clinique était réalisé de 28 a 36 mois. L'EVA et ODI diminuaient de 7,8 +/- 1,7 à 1,9 +/- 1,2 et de 62,3 +/- 17,2 à 15,1 +/- 6,0respectivement. L'ensemble des résultats était stable dans le temps en particulier à long terme.Conclusion: La fixation précise de la lyse isthmique améliore la symptomatologie et probablement évite un glissement vertébral plus important , un suivi à plus long terme surune serie de patients plus importante devrait confirmer cette hypothèse.
Resumo:
INTRODUCTION: Quantitative sensory testing (QST) is widely used in human research to investigate the integrity of the sensory function in patients with pain of neuropathic origin, or other causes such as low back pain. Reliability of QST has been evaluated on both sides of the face, hands and feet as well as on the trunk (Th3-L3). In order to apply these tests on other body-parts such as the lower lumbar spine, it is important first to establish reliability on healthy individuals. The aim of this study was to investigate intra-rater reliability of thermal QST in healthy adults, on two sites within the L5 dermatome of the lumbar spine and lower extremity. METHODS: Test-retest reliability of thermal QST was determined at the L5-level of the lumbar spine and in the same dermatome on the lower extremity in 30 healthy persons under 40 years of age. Results were analyzed using descriptive statistics and intraclass correlation coefficient (ICC). Values were compared to normative data, using Z-transformation. RESULTS: Mean intraindividual differences were small for cold and warm detection thresholds but larger for pain thresholds. ICC values showed excellent reliability for warm detection and heat pain threshold, good-to-excellent reliability for cold pain threshold and fair-to-excellent reliability for cold detection threshold. ICC had large ranges of confidence interval (95%). CONCLUSION: In healthy adults, thermal QST on the lumbar spine and lower extremity demonstrated fair-to-excellent test-retest reliability.