133 resultados para TRABECULAR PATTERN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deletions on the short arm of chromosome 4 cause Wolf-Hirschhorn syndrome (WHS) and Pitt-Rogers-Danks syndrome (PRDS). WHS is associated with severe growth and mental retardation, microcephaly, a characteristic facies and congenital malformations. The PRDS phenotype is similar to WHS but generally less severe. Seizures occur in the majority of WHS and PRDS patients. Sgrò et al. [17] described a stereotypic electroclinical pattern in four unrelated WHS patients, consisting of intermittent bursts of 2-3 Hz high voltage slow waves with spike wave activity in the parietal areas during drowsiness and sleep associated with myoclonic jerks. We report a patient with PRDS and the typical EEG pattern and review 14 WHS patients with similar EEG findings reported in the literature. CONCLUSION: Awareness and recognition of the characteristic electroclinical findings in Wolf-Hirschhorn syndrome and Pitt-Rogers-Danks syndrome might help in the early diagnosis of such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte : Identifier les patients avec une hémorragie sous-arachnoïdienne spontanée chez qui l'angio-CT suffit pour exclure des anévrysmes rompus.Méthodes : Une étude rétrospective a été effectuée de tous les patients avec une hémorragie sous-arachnoïdienne qui ont eu un angio-CT ainsi qu'une angiographie par cathéter dans le but d'exclure un anévrysme. Les cas négatifs de l'angio-CT (sans anévrysmes) ont été classés d'après leur schéma hémorragique au CT dans les catégories suivantes : « anévrysmale », « périmésencéphalique » puis « sans hémorragie ».Résultats : Deux-cent-quarante-et-un patients ont été inclus. Une sensibilité de 96.4% et une spécificité de 96.0% ont été observée pour l'exclusion d'anévrysmes par l'angio-CT. Parmi les 78 cas négatifs de l'angio-CT, chacun des 35 cas avec un motif hémorragique périmésencéphalique ou sans hémorragie au CT n'ont pas eu d'anévrysmes démontrés à l'angiographie par cathéter.Conclusions: L'angio-CT est fiable pour exclure les anévrysmes rompus lorsqu'un motif hémorragique périmésencéphalique ou pas d'hémorragie sont visibles au CT à une semaine depuis le début des symptômes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: In the milder form of primary hyperparathyroidism (PHPT), cancellous bone, represented by areal bone mineral density at the lumbar spine by dual-energy x-ray absorptiometry (DXA), is preserved. This finding is in contrast to high-resolution peripheral quantitative computed tomography (HRpQCT) results of abnormal trabecular microstructure and epidemiological evidence for increased overall fracture risk in PHPT. Because DXA does not directly measure trabecular bone and HRpQCT is not widely available, we used trabecular bone score (TBS), a novel gray-level textural analysis applied to spine DXA images, to estimate indirectly trabecular microarchitecture. Objective: The purpose of this study was to assess TBS from spine DXA images in relation to HRpQCT indices and bone stiffness in radius and tibia in PHPT. Design and Setting: This was a cross-sectional study conducted in a referral center. Patients: Participants were 22 postmenopausal women with PHPT. Main Outcome Measures: Outcomes measured were areal bone mineral density by DXA, TBS indices derived from DXA images, HRpQCT standard measures, and bone stiffness assessed by finite element analysis at distal radius and tibia. Results: TBS in PHPT was low at 1.24, representing abnormal trabecular microstructure (normal ≥1.35). TBS was correlated with whole bone stiffness and all HRpQCT indices, except for trabecular thickness and trabecular stiffness at the radius. At the tibia, correlations were observed between TBS and volumetric densities, cortical thickness, trabecular bone volume, and whole bone stiffness. TBS correlated with all indices of trabecular microarchitecture, except trabecular thickness, after adjustment for body weight. Conclusion: TBS, a measurement technology readily available by DXA, shows promise in the clinical assessment of trabecular microstructure in PHPT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Less-lethal weapons are used in law enforcement to neutralize combative individuals and to disperse riot crowds. Local police recently used such an impact weapon, the Flash-Ball, in two different situations. This gun fires large rubber bullets with kinetic energies around 200 J. Although it is designed to avoid skin penetration, impacts at such energies may still create major trauma with associated severe injuries to internal organs. This is a report of 2 patients shot with the Flash-Ball who required medical attention. One could be discharged quickly, but the other required hospitalization for heart and lung contusion. Both patients required advanced investigations including computed tomography (CT) scan. The medical literature on injuries induced by less-lethal impact weapons is reviewed. Impacts from the Flash-Ball can cause significant injury to internal organs, even without penetration. Investigations as for other high-energy blunt traumas are called for in these cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Altered bone micro-architecture is an important factor in accounting for fragility fractures. Until recently, it has not been possible to gain information about skeletal microstructure in a way that is clinically feasible. Bone biopsy is essentially a research tool. High-resolution peripheral Quantitative Computed Tomography, while non-invasive, is available only sparsely throughout the world. The trabecular bone score (TBS) is an imaging technology adapted directly from the Dual Energy X-Ray Absorptiometry (DXA) image of the lumbar spine. Thus, it is potentially readily and widely available. In recent years, a large number of studies have demonstrated that TBS is significantly associated with direct measurements of bone micro-architecture, predicts current and future fragility fractures in primary osteoporosis, and may be a useful adjunct to BMD for fracture detection and prediction. In this review, we summarize its potential utility in secondary causes of osteoporosis. In some situations, like glucocorticoid-induced osteoporosis and in diabetes mellitus, the TBS appears to out-perform DXA. It also has apparent value in numerous other disorders associated with diminished bone health, including primary hyperparathyroidism, androgen-deficiency, hormone-receptor positive breast cancer treatment, chronic kidney disease, hemochromatosis, and autoimmune disorders like rheumatoid arthritis. Further research is both needed and warranted to more clearly establish the role of TBS in these and other disorders that adversely affect bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the prognostic significance of scleroderma capillary pattern (SD-pattern) in patients with Raynaud's phenomenon. Thirty patients with a capillaroscopy examination suggestive of scleroderma (megacapillaries and/or avascularity) but without clinical criteria of scleroderma (ARA criteria) were reevaluated 6 years after the initial clinical and capillaroscopy examinations. SD-pattern abnormalities were classified according to a semiquantitative method. Eight out of the 28 evaluated patients (28%) developed a scleroderma spectrum disorder (SDS). The presence of avascularity and/or a mean of more than two megacapillaries digit greatly enhanced the percentage of evolution toward SDS (70%/88% respectively). Most of the patients with few enlarged capillaries and no capillary rarefaction at entry had primary acrocyanosis (11/15). None of them developed SDS. The microangiopathy disappeared during the follow-up period in most of these patients (14/15). These results confirm the prognostic value of SD-pattern capillary abnormalities for SDS. Primary acrocyanosis, a benign clinical entity should be considered in presence of few megacapillaries and without capillary rarefaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated behavioral adaptability, which could be defined as a blend between stability and flexibility of the limbs movement and their inter-limb coordination, when individuals received informational constraints. Seven expert breaststroke swimmers performed three 200-m in breaststroke at constant submaximal intensity. Each trial was performed randomly in a different coordination pattern: 'freely-chosen', 'maximal glide' and 'minimal glide'. Two underwater and four aerial cameras enabled 3D movement analysis in order to assess elbow and knee angles, elbow-knee pair coordination, intra-cyclic velocity variations of the center of mass, stroke rate and stroke length and inter-limb coordination. The energy cost of locomotion was calculated from gas exchanges and blood lactate concentration. The results showed significantly higher glide, intra-cyclic velocity variations and energy cost under 'maximal glide' compared to 'freely-chosen' instructional conditions, as well as higher reorganization of limb movement and inter-limb coordination (p<0.05). In the 'minimal glide' condition, the swimmers did not show significantly shorter glide and lower energy cost, but they exhibited significantly lower deceleration of the center of mass, as well as modified limb movement and inter-limb coordination (p<0.05). These results highlight that a variety of structural adaptations can functionally satisfy the task-goal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to assess the effect of iStent (trabecular micro-bypass stent) implantation in combination with phacoemulsification on IOP and glaucoma medications and to compare this to the outcome of phacoemulsification alone. Patients and Methods: A retrospective consecutive comparative review was undertaken. 131 eyes with ocular hypertension and medically controlled glaucoma underwent phacoemulsification alone (n = 78 group I) or combined with gonioscopic-guided implantation of one iStent (n = 31, group II) or two iStents (n = 22, group III). Patients were assessed at postoperative weeks 1, 3 and 6, and months 3 and 6. Pre- and post-operative measures included visual acuity, IOP and glaucoma medications. Results: Post-operatively at 6 months, mean IOP decreased from 16.3 mmHg to 14.2 mmHg in group I (p < 0.01), from 16.7 mmHg to 15.1 mmHg in group II (p < 0.16) and from 17.0 to 13.8 in group III (p = 0.05). Mean glaucoma medication decreased from 1.9 to 1.6 in group I (8 %, p = 0.12), from 2.5 to 0.8 in group II (27 %, p = 0.04), and from 2.1 to 1.0 in group III (45 %, p < 0.01). Conclusions: iStent implantation resulted in similar IOP reduction to phacoemulsification alone but achieved a significantly greater reduction in glaucoma medications. This may improve compliance and quality of life, and reduce health care costs in patients with early to moderate glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to determine the impact of trabecular bone score on the probability of fracture above that provided by the clinical risk factors utilized in FRAX. We performed a retrospective cohort study of 33,352 women aged 40-99 years from the province of Manitoba, Canada, with baseline measurements of lumbar spine trabecular bone score (TBS) and FRAX risk variables. The analysis was cohort-specific rather than based on the Canadian version of FRAX. The associations between trabecular bone score, the FRAX risk factors and the risk of fracture or death were examined using an extension of the Poisson regression model and used to calculate 10-year probabilities of fracture with and without TBS and to derive an algorithm to adjust fracture probability to take account of the independent contribution of TBS to fracture and mortality risk. During a mean follow-up of 4.7 years, 1754 women died and 1639 sustained one or more major osteoporotic fractures excluding hip fracture and 306 women sustained one or more hip fracture. When fully adjusted for FRAX risk variables, TBS remained a statistically significant predictor of major osteoporotic fractures excluding hip fracture (HR/SD 1.18, 95 % CI 1.12-1.24), death (HR/SD 1.20, 95 % CI 1.14-1.26) and hip fracture (HR/SD 1.23, 95 % CI 1.09-1.38). Models adjusting major osteoporotic fracture and hip fracture probability were derived, accounting for age and trabecular bone score with death considered as a competing event. Lumbar spine texture analysis using TBS is a risk factor for osteoporotic fracture and a risk factor for death. The predictive ability of TBS is independent of FRAX clinical risk factors and femoral neck BMD. Adjustment of fracture probability to take account of the independent contribution of TBS to fracture and mortality risk requires validation in independent cohorts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabecular bone score (TBS) is a recently-developed analytical tool that performs novel grey-level texture measurements on lumbar spine dual X-ray absorptiometry (DXA) images, and thereby captures information relating to trabecular microarchitecture. In order for TBS to usefully add to bone mineral density (BMD) and clinical risk factors in osteoporosis risk stratification, it must be independently associated with fracture risk, readily obtainable, and ideally, present a risk which is amenable to osteoporosis treatment. This paper summarizes a review of the scientific literature performed by a Working Group of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis. Low TBS is consistently associated with an increase in both prevalent and incident fractures that is partly independent of both clinical risk factors and areal BMD (aBMD) at the lumbar spine and proximal femur. More recently, TBS has been shown to have predictive value for fracture independent of fracture probabilities using the FRAX® algorithm. Although TBS changes with osteoporosis treatment, the magnitude is less than that of aBMD of the spine, and it is not clear how change in TBS relates to fracture risk reduction. TBS may also have a role in the assessment of fracture risk in some causes of secondary osteoporosis (e.g., diabetes, hyperparathyroidism and glucocorticoid-induced osteoporosis). In conclusion, there is a role for TBS in fracture risk assessment in combination with both aBMD and FRAX.