190 resultados para Simulation Testing
Resumo:
Background: Bacteria form biofilms on the surface of orthopaedic devices, causing persistent infections. Monitoring biofilm formation on bone grafts and bone substitutes is challenging due to heterogeneous surface characteristics. We analyzed various bone grafts and bone substitutes regarding their propensity for in-vitro biofilm formation caused by S. aureus and S. epidermidis. Methods: Beta-tricalciumphosphate (b-TCP, ChronOsTM), processed human spongiosa (TutoplastTM) and PMMA (PalacosTM) were investigated. PE was added as a growth control. As test strains S. aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) were used. Test materials were incubated with 105 cfu/ml. After 24 h, test materials were removed and washed, followed by a standardised sonication protocol. The resulting sonication fluid was plated and bacterial counts were enumerated and expressed as cfu/sample. Sonicated samples were transferred to a microcalorimeter (TA Instrument) and heat flow monitored over a 24 h period with a precision of 0.0001°C and a sensitiviy of 200 μW. Experiments were performed in triplicates to calculate the mean ± SD. One-way ANOVA analysis was used for statistical analysis. Results: Bacterial counts (log10 cfu/sample) were highest on b-TCP (S. aureus 7.67 ± 0.17; S. epidermidis 8.14 ± 0.05) while bacterial density (log10 cfu/surface) was highest on PMMA (S. aureus 6.12 ± 0.2, S. epidermidis 7.65 ± 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (b-TCP and Tutoplast, p <0.001) compared to the smooth materials (PMMA and PE) with no differences between b-TCP and TutoplastTM (p >0.05) or PMMA and PE (p >0.05). In contrast, for S. epidermidis biofilms the detection time was different (p <0.001) between all materials except between Tutoplast and PE (p >0.05). Conclusion: Our results demonstrate biofilm formation with both strains on all tested materials. Microcalorimetry was able to detect quantitatively the amount of biofilm. Further studies are needed to see whether calorimetry is a suitable tool also to monitor approaches to prevent and treat infections associated with bone grafts and bone substitutes.
Resumo:
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.
Resumo:
Miniature diffusion size classifiers (miniDiSC) are novel handheld devices to measure ultrafine particles (UFP). UFP have been linked to the development of cardiovascular and pulmonary diseases; thus, detection and quantification of these particles are important for evaluating their potential health hazards. As part of the UFP exposure assessments of highwaymaintenance workers in western Switzerland, we compared a miniDiSC with a portable condensation particle counter (P-TRAK). In addition, we performed stationary measurements with a miniDiSC and a scanning mobility particle sizer (SMPS) at a site immediately adjacent to a highway. Measurements with miniDiSC and P-TRAK correlated well (correlation of r = 0.84) but average particle numbers of the miniDiSC were 30%âeuro"60% higher. This difference was significantly increased for mean particle diameters below 40 nm. The correlation between theminiDiSC and the SMPSduring stationary measurements was very high (r = 0.98) although particle numbers from the miniDiSC were 30% lower. Differences between the three devices were attributed to the different cutoff diameters for detection. Correction for this size dependent effect led to very similar results across all counters.We did not observe any significant influence of other particle characteristics. Our results suggest that the miniDiSC provides accurate particle number concentrations and geometric mean diameters at traffic-influenced sites, making it a useful tool for personal exposure assessment in such settings.
The cost of inappropriateness of coagulation testing [I costi dell'inappropriatezza in coagulazione]
Resumo:
Background. Laboratory utilization has steadily increased with a corresponding increase in overall costs; several authors have attempted to measure the impact of inappropriateness on clinical outcomes but data are insufficient. The aim of the study is to assess the cost of inappropriateness of test-ordering behaviour for second-level coagulation tests (hemorrhagic diathesisand thrombophilia). Methods. We reviewed all second-level coagulation testrequests received by our department during a six months period. Clinicians must fill out a specific order form for these kind of tests, containing all informations deemed necessary for the laboratory specialist to evaluatethe appropriateness of the request. We identified all inappropriate requests and counted the numbers and types of all coagulation tests that were not performed during the period. An analysis of the laboratory activity costs was done in order to calculate the global costof each test in our department and to estimate the savings achieved. Results. On a total of 1664 second-level coagulationtest requests, we estimated 150 as completely inappropriate. We found an overall of 295 inappropriate testswhich were not performed. This resulted in an economic saving of 20.000 euro in 6 months. Conclusions. The analysis of cost of our intervention shows the urgent need for a definite and sustained reduction in inappropriate requests of second-level coagulation tests. Even though we estimated only the economic aspect of inappropriate testing, this is also associated with the overuse of diagnostic tests which entailsthe risk of generating erroneous results with potentialnegative consequences on patients' health.
Resumo:
OBJECTIVES: Kaposi's sarcoma (KS), invasive cervical carcinoma (ICC) and non-Hodgkin lymphoma (NHL) have been listed as AIDS-defining cancers (ADCs) by the Centers for Disease Control and Prevention since 1993. Despite this, HIV screening is not universally mentioned in ADC treatment guidelines. We examined screening practices at a tertiary centre serving a population where HIV seroprevalence is 0.4%. METHODS: Patients with KS, ICC, NHL and Hodgkin lymphoma (HL), treated at Lausanne University Hospital between January 2002 and July 2012, were studied retrospectively. HIV testing was considered part of the oncology work-up if performed between 90 days before and 90 days after the cancer diagnosis date. RESULTS: A total of 880 patients were examined: 10 with KS, 58 with ICC, 672 with NHL and 140 with HL. HIV testing rates were 100, 11, 60 and 59%, and HIV seroprevalence was 60, 1.7, 3.4 and 5%, respectively. Thirty-seven patients (4.2%) were HIV-positive, of whom eight (22%) were diagnosed at oncology work-up. All newly diagnosed patients had CD4 counts < 200 cells/μL and six (75%) had presented to a physician 12-236 weeks previously with conditions warranting HIV testing. CONCLUSIONS: In our institution, only patients with KS were universally screened. Screening rates for other cancers ranged from 11 to 60%. HIV seroprevalence was at least fourfold higher than the population average. As HIV-positive status impacts on cancer patient medical management, HIV screening should be included in oncology guidelines. Further, we recommend that opt-out screening should be adopted in all patients with ADCs and HL.
Resumo:
We perform direct numerical simulations of drainage by solving Navier- Stokes equations in the pore space and employing the Volume Of Fluid (VOF) method to track the evolution of the fluid-fluid interface. After demonstrating that the method is able to deal with large viscosity contrasts and to model the transition from stable flow to viscous fingering, we focus on the definition of macroscopic capillary pressure. When the fluids are at rest, the difference between inlet and outlet pressures and the difference between the intrinsic phase average pressure coincide with the capillary pressure. However, when the fluids are in motion these quantities are dominated by viscous forces. In this case, only a definition based on the variation of the interfacial energy provides an accurate measure of the macroscopic capillary pressure and allows separating the viscous from the capillary pressure components.
Resumo:
According to the annual report of the World Anti-Doping Agency, steroids are the most frequently detected class of doping agents. Detecting the misuse of endogenously occurring steroids, i.e. steroids such as testosterone that are produced naturally by humans, is one of the most challenging issues in doping control analysis. The established thresholds for urinary concentrations or concentration ratios such as the testosterone/epitestosterone quotient are sometimes inconclusive owing to the large biological variation in these parameters.For more than 15 years, doping control laboratories focused on the carbon isotope ratios of endogenous steroids to distinguish between naturally elevated steroid profile parameters and illicit administration of steroids. A variety of different methods has been developed throughout the last decade and the number of different steroids under investigation by isotope ratio mass spectrometry has recently grown considerably. Besides norandrosterone, boldenone was found to occur endogenously in rare cases and the misuse of corticosteroids or epitestosterone can now be detected with the aid of carbon isotope ratios as well. In addition, steroids excreted as sulfoconjugates were investigated, and the first results regarding hydrogen isotope ratios recently became available.All of these will be presented in detail within this review together with some considerations on validation issues and on identification of parameters influencing steroidal isotope ratios in urine.
Resumo:
DNA condensation observed in vitro with the addition of polyvalent counterions is due to intermolecular attractive forces. We introduce a quantitative model of these forces in a Brownian dynamics simulation in addition to a standard mean-field Poisson-Boltzmann repulsion. The comparison of a theoretical value of the effective diameter calculated from the second virial coefficient in cylindrical geometry with some experimental results allows a quantitative evaluation of the one-parameter attractive potential. We show afterward that with a sufficient concentration of divalent salt (typically approximately 20 mM MgCl(2)), supercoiled DNA adopts a collapsed form where opposing segments of interwound regions present zones of lateral contact. However, under the same conditions the same plasmid without torsional stress does not collapse. The condensed molecules present coexisting open and collapsed plectonemic regions. Furthermore, simulations show that circular DNA in 50% methanol solutions with 20 mM MgCl(2) aggregates without the requirement of torsional energy. This confirms known experimental results. Finally, a simulated DNA molecule confined in a box of variable size also presents some local collapsed zones in 20 mM MgCl(2) above a critical concentration of the DNA. Conformational entropy reduction obtained either by supercoiling or by confinement seems thus to play a crucial role in all forms of condensation of DNA.
Resumo:
We have modeled numerically the seismic response of a poroelastic inclusion with properties applicable to an oil reservoir that interacts with an ambient wavefield. The model includes wave-induced fluid flow caused by pressure differences between mesoscopic-scale (i.e., in the order of centimeters to meters) heterogeneities. We used a viscoelastic approximation on the macroscopic scale to implement the attenuation and dispersion resulting from this mesoscopic-scale theory in numerical simulations of wave propagation on the kilometer scale. This upscaling method includes finite-element modeling of wave-induced fluid flow to determine effective seismic properties of the poroelastic media, such as attenuation of P- and S-waves. The fitted, equivalent, viscoelastic behavior is implemented in finite-difference wave propagation simulations. With this two-stage process, we model numerically the quasi-poroelastic wave-propagation on the kilometer scale and study the impact of fluid properties and fluid saturation on the modeled seismic amplitudes. In particular, we addressed the question of whether poroelastic effects within an oil reservoir may be a plausible explanation for low-frequency ambient wavefield modifications observed at oil fields in recent years. Our results indicate that ambient wavefield modification is expected to occur for oil reservoirs exhibiting high attenuation. Whether or not such modifications can be detected in surface recordings, however, will depend on acquisition design and noise mitigation processing as well as site-specific conditions, such as the geologic complexity of the subsurface, the nature of the ambient wavefield, and the amount of surface noise.
Resumo:
OBJECTIVE: HIV-1 post-exposure prophylaxis (PEP) is frequently prescribed after exposure to source persons with an undetermined HIV serostatus. To reduce unnecessary use of PEP, we implemented a policy including active contacting of source persons and the availability of free, anonymous HIV testing ('PEP policy'). METHODS: All consultations for potential non-occupational HIV exposures i.e. outside the medical environment) were prospectively recorded. The impact of the PEP policy on PEP prescription and costs was analysed and modelled. RESULTS: Among 146 putative exposures, 47 involved a source person already known to be HIV positive and 23 had no indication for PEP. The remaining 76 exposures involved a source person of unknown HIV serostatus. Of 33 (43.4%) exposures for which the source person could be contacted and tested, PEP was avoided in 24 (72.7%), initiated and discontinued in seven (21.2%), and prescribed and completed in two (6.1%). In contrast, of 43 (56.6%) exposures for which the source person could not be tested, PEP was prescribed in 35 (81.4%), P < 0.001. Upon modelling, the PEP policy allowed a 31% reduction of cost for management of exposures to source persons of unknown HIV serostatus. The policy was cost-saving for HIV prevalence of up to 70% in the source population. The availability of all the source persons for testing would have reduced cost by 64%. CONCLUSION: In the management of non-occupational HIV exposures, active contacting and free, anonymous testing of source persons proved feasible. This policy resulted in a decrease in prescription of PEP, proved to be cost-saving, and presumably helped to avoid unnecessary toxicity and psychological stress.
Resumo:
Using Monte Carlo simulations and reanalyzing the data of a validation study of the AEIM emotional intelligence test, we demonstrated that an atheoretical approach and the use of weak statistical procedures can result in biased validity estimates. These procedures included stepwise regression-and the general case of failing to include important theoretical controls-extreme scores analysis, and ignoring heteroscedasticity as well as measurement error. The authors of the AEIM test responded by offering more complete information about their analyses, allowing us to further examine the perils of ignoring theory and correct statistical procedures. In this paper we show with extended analyses that the AEIM test is invalid.