133 resultados para Safety glass.
Resumo:
Linezolid is used off-label to treat multidrug-resistant tuberculosis (MDR-TB) in absence of systematic evidence. We performed a systematic review and meta-analysis on efficacy, safety and tolerability of linezolid-containing regimes based on individual data analysis. 12 studies (11 countries from three continents) reporting complete information on safety, tolerability, efficacy of linezolid-containing regimes in treating MDR-TB cases were identified based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Meta-analysis was performed using the individual data of 121 patients with a definite treatment outcome (cure, completion, death or failure). Most MDR-TB cases achieved sputum smear (86 (92.5%) out of 93) and culture (100 (93.5%) out of 107) conversion after treatment with individualised regimens containing linezolid (median (inter-quartile range) times for smear and culture conversions were 43.5 (21-90) and 61 (29-119) days, respectively) and 99 (81.8%) out of 121 patients were successfully treated. No significant differences were detected in the subgroup efficacy analysis (daily linezolid dosage ≤600 mg versus >600 mg). Adverse events were observed in 63 (58.9%) out of 107 patients, of which 54 (68.4%) out of 79 were major adverse events that included anaemia (38.1%), peripheral neuropathy (47.1%), gastro-intestinal disorders (16.7%), optic neuritis (13.2%) and thrombocytopenia (11.8%). The proportion of adverse events was significantly higher when the linezolid daily dosage exceeded 600 mg. The study results suggest an excellent efficacy but also the necessity of caution in the prescription of linezolid.
Resumo:
BACKGROUND: To ensure vaccines safety, given the weaknesses of the national pharmacovigilance system in Cameroon, there is a need to identify effective interventions that can contribute to improving AEFI reporting. OBJECTIVE: To assess the effect of: (i) sending weekly SMS, or (ii) weekly supervisory visits on AEFI reporting rate during a meningitis immunization campaign conducted in Cameroon in 2012 using the meningitis A conjugate vaccine (MenAfriVac?). METHODS: Health facilities that met the inclusion criteria were randomly assigned to receive: (i) a weekly standardized SMS, (ii) a weekly standardized supervisory visits or (iii) no intervention. The primary outcome was the reported AEFI incidence rate from week 5 to 8 after the immunization campaign. Poisson regression model was used to estimate the effect of interventions after adjusting for health region, type of health facility, type and position of health workers as well as the cumulative number of AEFI reported from weeks 1 to 4. RESULTS: A total of 348 (77.2%) of 451 health facility were included, and 116 assigned to each of three groups. The incidence rate of reported AEFI per 100 health facility per week was 20.0 (15.9-24.1) in the SMS group, 40.2 (34.4-46.0) in supervision group and 13.6 (10.1-16.9) in the control group. Supervision led to a significant increase of AEFI reporting rate compared to SMS [adjusted RR=2.1 (1.6-2.7); p<0.001] and control [RR=2.8(2.1-3.7); p<0.001)] groups. The effect of SMS led to some increase in AEFI reporting rate compared to the control group, but the difference was not statistically significant [RR=1.4(0.8-1.6); p=0.07)]. CONCLUSION: Supervision was more effective than SMS or routine surveillance in improving AEFI reporting rate. It should be part of any AEFI surveillance system. SMS could be useful in improving AEFI reporting rates but strategies need to be found to improve its effectiveness, and thus maximize its benefits.
Resumo:
BACKGROUND: Cardiac arrest causes ischaemic brain injury. Arterial carbon dioxide tension (PaCO2) is a major determinant of cerebral blood flow. Thus, mild hypercapnia in the 24 h following cardiac arrest may increase cerebral blood flow and attenuate such injury. We describe the Carbon Control and Cardiac Arrest (CCC) trial. METHODS/DESIGN: The CCC trial is a pilot multicentre feasibility, safety and biological efficacy randomized controlled trial recruiting adult cardiac arrest patients admitted to the intensive care unit after return of spontaneous circulation. At admission, using concealed allocation, participants are randomized to 24 h of either normocapnia (PaCO2 35 to 45 mmHg) or mild hypercapnia (PaCO2 50 to 55 mmHg). Key feasibility outcomes are recruitment rate and protocol compliance rate. The primary biological efficacy and biological safety measures are the between-groups difference in serum neuron-specific enolase and S100b protein levels at 24 h, 48 h and 72 h. Secondary outcome measure include adverse events, in-hospital mortality, and neurological assessment at 6 months. DISCUSSION: The trial commenced in December 2012 and, when completed, will provide clinical evidence as to whether targeting mild hypercapnia for 24 h following intensive care unit admission for cardiac arrest patients is feasible and safe and whether it results in decreased concentrations of neurological injury biomarkers compared with normocapnia. Trial results will also be used to determine whether a phase IIb study powered for survival at 90 days is feasible and justified. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12612000690853 .
Resumo:
OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.
Resumo:
Over the years, transfusion medicine has been faced to many different problems, notably those related to transmission of pathogens. Major progresses have been accomplished in terms of security. However, nowadays, the discipline is confronted to the day-to-day variability and availability of blood products. More and more donors are excluded from blood donation due to various reasons, and the donor selection criteria have increased over the years, influencing the number of donors able to give blood. This paradox represents one of the constraints that transfusion medicine should resolve in the future. This paper presents some aspects either common or different between France and Switzerland.
Resumo:
OBJECTIVE: To assess safety up to 1 year of follow-up associated with prasugrel and clopidogrel use in a prospective cohort of patients with acute coronary syndromes (ACS). METHODS: Between 2009 and 2012, 2286 patients invasively managed for ACS were enrolled in the multicentre Swiss ACS Bleeding Cohort, among whom 2148 patients received either prasugrel or clopidogrel according to current guidelines. Patients with ST-elevation myocardial infarction (STEMI) preferentially received prasugrel, while those with non-STEMI, a history of stroke or transient ischaemic attack, age ≥75 years, or weight <60 kg received clopidogrel or reduced dose of prasugrel to comply with the prasugrel label. RESULTS: After adjustment using propensity scores, the primary end point of clinically relevant bleeding events (defined as the composite of Bleeding Academic Research Consortium, BARC, type 3, 4 or 5 bleeding) at 1 year, occurred at a similar rate in both patient groups (prasugrel/clopidogrel: 3.8%/5.5%). Stratified analyses in subgroups including patients with STEMI yielded a similar safety profile. After adjusting for baseline variables, no relevant differences in major adverse cardiovascular and cerebrovascular events were observed at 1 year (prasugrel/clopidogrel: cardiac death 2.6%/4.2%, myocardial infarction 2.7%/3.8%, revascularisation 5.9%/6.7%, stroke 1.0%/1.6%). Of note, this study was not designed to compare efficacy between prasugrel and clopidogrel. CONCLUSIONS: In this large prospective ACS cohort, patients treated with prasugrel according to current guidelines (ie, in patients without cerebrovascular disease, old age or underweight) had a similar safety profile compared with patients treated with clopidogrel. CLINICAL TRIAL REGISTRATION NUMBER: SPUM-ACS: NCT01000701; COMFORTABLE AMI: NCT00962416.
Resumo:
The worldwide antibiotic crisis has led to a renewed interest in phage therapy. Since time immemorial phages control bacterial populations on Earth. Potent lytic phages against bacterial pathogens can be isolated from the environment or selected from a collection in a matter of days. In addition, phages have the capacity to rapidly overcome bacterial resistances, which will inevitably emerge. To maximally exploit these advantage phages have over conventional drugs such as antibiotics, it is important that sustainable phage products are not submitted to the conventional long medicinal product development and licensing pathway. There is a need for an adapted framework, including realistic production and quality and safety requirements, that allowsa timely supplying of phage therapy products for 'personalized therapy' or for public health or medical emergencies. This paper enumerates all phage therapy product related quality and safety risks known to the authors, as well as the tests that can be performed to minimize these risks, only to the extent needed to protect the patients and to allow and advance responsible phage therapy and research.
Resumo:
Sucroferric oxyhydroxide (VELPHORO(®)) is a polynuclear iron-based phosphate binder recently approved for the treatment of hyperphosphataemia in patients with chronic kidney disease (CKD). As a number of the available phosphate binders do not provide the optimal combination of good efficacy, adequate tolerability and low pill burden, sucroferric oxyhydroxide constitutes a promising alternative. Among the attributes of an ideal phosphate binder is minimal absorption and, hence, low risk of systemic toxicity. Accordingly, the iron-releasing properties and absorption, distribution, metabolism and excretion (ADME) profile of sucroferric oxyhydroxide, as well as the possibility of iron accumulation and toxicity, were investigated in a series of preclinical studies. The effect of sucroferric oxyhydroxide on the progression of vascular calcification was also investigated. Sucroferric oxyhydroxide exhibited a high phosphate-binding capacity and low iron-releasing properties across the physiological pH range found in the gastrointestinal tract. In the ADME studies, uptake of (59)Fe-radiolabelled sucroferric oxyhydroxide was low in rats and dogs (<1% from a 50 mg Fe/kg bodyweight dose), with the majority of absorbed iron located in red blood cells. Long-term (up to 2 years) administration of sucroferric oxyhydroxide in rats and dogs was associated with modest increases in tissue iron levels and no iron toxicity. Moreoever, in uraemic rats, sucroferric oxyhydroxide was associated with reduced progression of vascular calcification compared with calcium carbonate. In conclusion, sucroferric oxyhydroxide offers a new option for the treatment of hyperphosphataemia, with a high phosphate-binding capacity, minimal iron release, and low potential for iron accumulation and toxicity.
Resumo:
In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.
Resumo:
PURPOSE: To develop a consensus opinion regarding capturing diagnosis-timing in coded hospital data. METHODS: As part of the World Health Organization International Classification of Diseases-11th Revision initiative, the Quality and Safety Topic Advisory Group is charged with enhancing the capture of quality and patient safety information in morbidity data sets. One such feature is a diagnosis-timing flag. The Group has undertaken a narrative literature review, scanned national experiences focusing on countries currently using timing flags, and held a series of meetings to derive formal recommendations regarding diagnosis-timing reporting. RESULTS: The completeness of diagnosis-timing reporting continues to improve with experience and use; studies indicate that it enhances risk-adjustment and may have a substantial impact on hospital performance estimates, especially for conditions/procedures that involve acutely ill patients. However, studies suggest that its reliability varies, is better for surgical than medical patients (kappa in hip fracture patients of 0.7-1.0 versus kappa in pneumonia of 0.2-0.6) and is dependent on coder training and setting. It may allow simpler and more precise specification of quality indicators. CONCLUSIONS: As the evidence indicates that a diagnosis-timing flag improves the ability of routinely collected, coded hospital data to support outcomes research and the development of quality and safety indicators, the Group recommends that a classification of 'arising after admission' (yes/no), with permitted designations of 'unknown or clinically undetermined', will facilitate coding while providing flexibility when there is uncertainty. Clear coding standards and guidelines with ongoing coder education will be necessary to ensure reliability of the diagnosis-timing flag.
Resumo:
Fear of risk provides a rationale for protracted economic downturns. We develop a real business cycle model where investors with decreasing relative risk aversion choose between a risky and a safe technology that exhibit decreasing returns. Because of a feedback effect from the interest rate to risk aversion, two equilibria can emerge: a standard equilibrium and a "safe" one in which investors invest in safer assets. We refer to the dynamics of this second equilibrium as a safety trap because it is self-reinforcing as investors accumulate more wealth and show it to be consistent with Japan's lost decade.