161 resultados para SIMPLE ASSAY
Resumo:
Raltegravir (RAL), maraviroc (MVC), darunavir (DRV), and etravirine (ETV) are new antiretroviral agents with significant potential for drug interactions. This work describes a sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of plasma drug levels. Single-step extraction of RAL, MVC, DRV, ETV and RTV from plasma (100 microl) is performed by protein precipitation using 600 microl of acetonitrile, after the addition of 100 microl darunavir-d(9) (DRV-d(9)) at 1000 ng/ml in MeOH/H(2)O 50/50 as internal standard (I.S.). The mixture is vortexed, sonicated for 10 min, vortex-mixed again and centrifuged. An aliquot of supernatant (150 microl) is diluted 1:1 with a mixture of 20 mM ammonium acetate/MeOH 40/60 and 10 microl is injected onto a 2.1 x 50 mm Waters Atlantis-dC18 3 microm analytical column. Chromatographic separations are performed using a gradient program with 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electrospray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring detection in the positive mode. The method has been validated over the clinically relevant concentrations ranging from 12.5 to 5000 ng/ml, 2.5 to 1000 ng/ml, 25 to 10,000 ng/ml, 10 to 4000 ng/ml, and 5 to 2000 ng/ml for RAL, MRV, DRV, ETV and RTV, respectively. The extraction recovery for all antiretroviral drugs is always above 91%. The method is precise, with mean inter-day CV% within 5.1-9.8%, and accurate (range of inter-day deviation from nominal values -3.3 to +5.1%). In addition our method enables the simultaneous assessment of raltegravir-glucuronide. This is the first analytical method allowing the simultaneous assay of antiretroviral agents targeted to four different steps of HIV replication. The proposed method is suitable for the Therapeutic Drug Monitoring Service of these new regimen combinations administered as salvage therapy to patients having experienced treatment failure, and for whom exposure, tolerance and adherence assessments are critical.
Resumo:
Abstract We introduce a label-free technology based on digital holographic microscopy (DHM) with applicability for screening by imaging, and we demonstrate its capability for cytotoxicity assessment using mammalian living cells. For this first high content screening compatible application, we automatized a digital holographic microscope for image acquisition of cells using commercially available 96-well plates. Data generated through both label-free DHM imaging and fluorescence-based methods were in good agreement for cell viability identification and a Z'-factor close to 0.9 was determined, validating the robustness of DHM assay for phenotypic screening. Further, an excellent correlation was obtained between experimental cytotoxicity dose-response curves and known IC values for different toxic compounds. For comparable results, DHM has the major advantages of being label free and close to an order of magnitude faster than automated standard fluorescence microscopy.
Resumo:
Because of the large variability in the pharmacokinetics of anti-HIV drugs, therapeutic drug monitoring in patients may contribute to optimize the overall efficacy and safety of antiretroviral therapy. An LC-MS/MS method for the simultaneous assay in plasma of the novel antiretroviral agents rilpivirine (RPV) and elvitegravir (EVG) has been developed to that endeavor. Plasma samples (100 μL) extraction is performed by protein precipitation with acetonitrile, and the supernatant is subsequently diluted 1:1 with 20-mM ammonium acetate/MeOH 50:50. After reverse-phase chromatography, quantification of RPV and EVG, using matrix-matched calibration samples, is performed by electrospray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The stable isotopic-labeled compounds RPV-(13) C6 and EVG-D6 were used as internal standards. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<6.4%), as well as EVG and RPV short and long-term stability in plasma. Calibration curves were validated over the clinically relevant concentrations ranging from 5 to 2500 ng/ml for RPV and from 50 to 5000 ng/ml for EVG. The method is precise (inter-day CV%: 3-6.3%) and accurate (3.8-7.2%). Plasma samples were found to be stable (<15%) in all considered conditions (RT/48 h, +4°C/48 h, -20°C/3 months and 60°C/1 h). Selected metabolite profiles analysis in patients' samples revealed the presence of EVG glucuronide, that was well separated from parent EVG, allowing to exclude potential interferences through the in-source dissociation of glucuronide to parent drug. This new, rapid and robust LCMS/MS assay for the simultaneous quantification of plasma concentrations of these two major new anti-HIV drugs EVG and RPV offers an efficient analytical tool for clinical pharmacokinetics studies and routine therapeutic drug monitoring service. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
We describe an improved multiple-locus variable-number tandem-repeat (VNTR) analysis (MLVA) scheme for genotyping Staphylococcus aureus. We compare its performance to those of multilocus sequence typing (MLST) and spa typing in a survey of 309 strains. This collection includes 87 epidemic methicillin-resistant S. aureus (MRSA) strains of the Harmony collection, 75 clinical strains representing the major MLST clonal complexes (CCs) (50 methicillin-sensitive S. aureus [MSSA] and 25 MRSA), 135 nasal carriage strains (133 MSSA and 2 MRSA), and 13 published S. aureus genome sequences. The results show excellent concordance between the techniques' results and demonstrate that the discriminatory power of MLVA is higher than those of both MLST and spa typing. Two hundred forty-two genotypes are discriminated with 14 VNTR loci (diversity index, 0.9965; 95% confidence interval, 0.9947 to 0.9984). Using a cutoff value of 45%, 21 clusters are observed, corresponding to the CCs previously defined by MLST. The variability of the different tandem repeats allows epidemiological studies, as well as follow-up of the evolution of CCs and the identification of potential ancestors. The 14 loci can conveniently be analyzed in two steps, based upon a first-line simplified assay comprising a subset of 10 loci (panel 1) and a second subset of 4 loci (panel 2) that provides higher resolution when needed. In conclusion, the MLVA scheme proposed here, in combination with available on-line genotyping databases (including http://mlva.u-psud.fr/), multiplexing, and automatic sizing, can provide a basis for almost-real-time large-scale population monitoring of S. aureus.
Resumo:
The antifungal agent fluconazole (FLC) is widely used in clinical practice. Monitoring FLC levels is useful in complicated clinical settings and in experimental infection models. A bioassay using Candida pseudotropicalis, a simple and cost-effective method, is validated only for FLC levels ranging from 5 to 40 mg/liter. An extension of the analytical range is needed to cover most yeast MICs. A new bioassay in RPMI agar containing methylene blue was developed using C. albicans DSY1024, a mutant rendered hypersusceptible to FLC constructed by the deletion of the multidrug efflux transporter genes CDR1, CDR2, CaMDR1, and FLU1. Reproducible standard curves were obtained with FLC concentrations in plasma ranging from 1 to 100 mg/liter (quadratic regression coefficient > 0.997). The absolute sensitivity was 0.026 microg of FLC. The method was internally validated according to current guidelines for analytical method validation. Both accuracy and precision lied in the required +/-15% range. FLC levels measured by bioassay and by high-performance liquid chromatography (HPLC) performed with 62 plasma samples from humans and rats showed a strong correlation (coefficients, 0.979 and 0.995, respectively; percent deviations of bioassay from HPLC values, 0.44% +/- 15.31% and 2.66% +/- 7.54%, respectively). In summary, this newly developed bioassay is sensitive, simple, rapid, and inexpensive. It allows nonspecialized laboratories to determine FLC levels in plasma to within the clinically relevant concentration range and represents a useful tool for experimental treatment models.
Resumo:
We have compared a multiplexed bead-based assay (BBA) with an enzyme immunoassay (EIA) and immunofluorescence assay (IFA) for the assessment of the Epstein-Barr virus (EBV) serostatus. Three hundred and ninety-three sera, classified according to IFA results as seronegative (n=100), acute infection (n=100), past infection (n=100) and indeterminate (n=93), were tested by BBA and EIA. Overall, the three methods gave similar results with a relatively high (75.2%) concordance with the consensus interpretation of the serostatus. The most significant discordances were: (i) 58 samples had uninterpretable results for BBA, in majority due to the detection of non-antigen specific antibody binding by control beads. (ii) almost half the samples positive for anti-Epstein-Barr nuclear antigen (EBNA) IgG by BBA or EIA were negative by IFA. Among the latter, only a minority had a history of immunocompromise or treatment, or detectable anti-early antigen antibody. This discrepancy probably reflects a poor sensitivity of IFA for anti-EBNA IgG detection. EIA and BBA had a similar performance and had substantial practical advantages over IFA with respect to testing for EBV serostatus.
Resumo:
Tumour immunologists strive to develop efficient tumour vaccination and adoptive transfer therapies that enlarge the pool of tumour-specific and -reactive effector T-cells in vivo. To assess the efficiency of the various strategies, ex vivo assays are needed for the longitudinal monitoring of the patient's specific immune responses providing both quantitative and qualitative data. In particular, since tumour cell cytolysis is the end goal of tumour immunotherapy, routine immune monitoring protocols need to include a read-out for the cytolytic efficiency of Ag-specific cells. We propose to combine current immune monitoring techniques in a highly sensitive and reproducible multi-parametric flow cytometry based cytotoxicity assay that has been optimised to require low numbers of Ag-specific T-cells. The possibility of re-analysing those T-cells that have undergone lytic activity is illustrated by the concomitant detection of CD107a upregulation on the surface of degranulated T-cells. To date, the LiveCount Assay provides the only possibility of assessing the ex vivo cytolytic activity of low-frequency Ag-specific cytotoxic T-lymphocytes from patient material.
Resumo:
We present a combined shape and mechanical anisotropy evolution model for a two-phase inclusion-bearing rock subject to large deformation. A single elliptical inclusion embedded in a homogeneous but anisotropic matrix is used to represent a simplified shape evolution enforced on all inclusions. The mechanical anisotropy develops due to the alignment of elongated inclusions. The effective anisotropy is quantified using the differential effective medium (DEM) approach. The model can be run for any deformation path and an arbitrary viscosity ratio between the inclusion and host phase. We focus on the case of simple shear and weak inclusions. The shape evolution of the representative inclusion is largely insensitive to the anisotropy development and to parameter variations in the studied range. An initial hardening stage is observed up to a shear strain of gamma = 1 irrespective of the inclusion fraction. The hardening is followed by a softening stage related to the developing anisotropy and its progressive rotation toward the shear direction. The traction needed to maintain a constant shear rate exhibits a fivefold drop at gamma = 5 in the limiting case of an inviscid inclusion. Numerical simulations show that our analytical model provides a good approximation to the actual evolution of a two-phase inclusion-host composite. However, the inclusions develop complex sigmoidal shapes resulting in the formation of an S-C fabric. We attribute the observed drop in the effective normal viscosity to this structural development. We study the localization potential in a rock column bearing varying fraction of inclusions. In the inviscid inclusion case, a strain jump from gamma = 3 to gamma = 100 is observed for a change of the inclusion fraction from 20% to 33%.
Resumo:
Management of musculoskeletal tumours usually begins with the appearance of a lump or bump, or the onset of unspecific symptoms. A poor initial work-up, a faulty biopsy or an inadequate resection may have a severe impact on the prognosis, including re-interventions, amputation, local recurrence or systemic spread of the disease. The patient with a suspicious lesion should be referred to a "sarcoma centers" where a planned and well-performed diagnostic work-up will allow a precise diagnosis in terms of histology and staging. After a multidisciplinary discussion of the case, an accurate treatment plan is established. Such an approach allows an adequate patient management, often with a positive impact on the survival and functional outcome.
Resumo:
A simple method determining airborne monoethanolamine has been developed. Monoethanolamine determination has traditionally been difficult due to analytical separation problems. Even in recent sophisticated methods, this difficulty remains as the major issue often resulting in time-consuming sample preparations. Impregnated glass fiber filters were used for sampling. Desorption of monoethanolamine was followed by capillary GC analysis and nitrogen phosphorous selective detection. Separation was achieved using a specific column for monoethanolamines (35% diphenyl and 65% dimethyl polysiloxane). The internal standard was quinoline. Derivatization steps were not needed. The calibration range was 0.5-80 μg/mL with a good correlation (R(2) = 0.996). Averaged overall precisions and accuracies were 4.8% and -7.8% for intraday (n = 30), and 10.5% and -5.9% for interday (n = 72). Mean recovery from spiked filters was 92.8% for the intraday variation, and 94.1% for the interday variation. Monoethanolamine on stored spiked filters was stable for at least 4 weeks at 5°C. This newly developed method was used among professional cleaners and air concentrations (n = 4) were 0.42 and 0.17 mg/m(3) for personal and 0.23 and 0.43 mg/m(3) for stationary measurements. The monoethanolamine air concentration method described here was simple, sensitive, and convenient both in terms of sampling and analytical analysis.
Resumo:
BACKGROUND: The activity of the renin-angiotensin system is usually evaluated as plasma renin activity (PRA, ngAI/ml per h) but the reproducibility of this enzymatic assay is notoriously scarce. We compared the inter and intralaboratory reproducibilities of PRA with those of a new automated chemiluminescent assay, which allows the direct quantification of immunoreactive renin [chemiluminescent immunoreactive renin (CLIR), microU/ml]. METHODS: Aliquots from six pool plasmas of patients with very low to very high PRA levels were measured in 12 centres with both the enzymatic and the direct assays. The same methods were applied to three control plasma preparations with known renin content. RESULTS: In pool plasmas, mean PRA values ranged from 0.14 +/- 0.08 to 18.9 +/- 4.1 ngAI/ml per h, whereas those of CLIR ranged from 4.2 +/- 1.7 to 436 +/- 47 microU/ml. In control plasmas, mean values of PRA and of CLIR were always within the expected range. Overall, there was a significant correlation between the two methods (r = 0.73, P < 0.01). Similar correlations were found in plasmas subdivided in those with low, intermediate and high PRA. However, the coefficients of variation among laboratories found for PRA were always higher than those of CLIR, ranging from 59.4 to 17.1% for PRA, and from 41.0 to 10.7% for CLIR (P < 0.01). Also, the mean intralaboratory variability was higher for PRA than for CLIR, being respectively, 8.5 and 4.5% (P < 0.01). CONCLUSION: The measurement of renin with the chemiluminescent method is a reliable alternative to PRA, having the advantage of a superior inter and intralaboratory reproducibility.
Resumo:
Mouse mammary tumor virus (MMTV) infection of adult mice induces a strong response to superantigen (Sag) in their draining lymph nodes, which results from the presentation of Sag by MMTV-infected B cells to Sag-reactive T cells. To date, infection with physiologically relevant doses of MMTV can be detected in vivo only after several days of Sag-mediated T-cell-dependent amplification of infected B cells. Furthermore, no efficient in vitro system of detecting MMTV infection is available. Such a model would allow the dissection of the early phase of infection, the assessment of the contributions of different cell types, and the screening of large panels of molecules for their potential roles in infection and Sag response. For these reasons, we have established an in vitro model for detecting infection which is as sensitive and reproducible as the in vivo model. We found that the viral envelope (Env) protein is crucial for target cell infection but not for presentation of Sag. Furthermore, we show that infection of purified B cells with MMTV induces entry of Sag-responsive T cells into the cell cycle, while other professional antigen-presenting cells, such as dendritic cells, are much less efficient in inducing a response.
Resumo:
Background: Modelling epidemiological knowledge in validated clinical scores is a practical mean of integrating EBM to usual care. Existing scores about cardiovascular disease have been largely developed in emergency settings, but few in primary care. Such a toll is needed for general practitioners (GP) to evaluate the probability of ischemic heart disease (IHD) in patients with non-traumatic chest pain. Objective: To develop a predictive model to use as a clinical score for detecting IHD in patients with non-traumatic chest-pain in primary care. Methods: A post-hoc secondary analysis on data from an observational study including 672 patients with chest pain of which 85 had IHD diagnosed by their GP during the year following their inclusion. Best subset method was used to select 8 predictive variables from univariate analysis and fitted in a multivariate logistic regression model to define the score. Reliability of the model was assessed using split-group method. Results: Significant predictors were: age (0-3 points), gender (1 point), having at least one cardiovascular risks factor (hypertension, dyslipidemia, diabetes, smoking, family history of CVD; 3 points), personal history of cardiovascular disease (1 point), duration of chest pain from 1 to 60 minutes (2 points), substernal chest pain (1 point), pain increasing with exertion (1 point) and absence of tenderness at palpation (1 point). Area under the ROC curve for the score was of 0.95 (IC95% 0.93; 0.97). Patients were categorised in three groups, low risk of IHD (score under 6; n = 360), moderate risk of IHD (score from 6 to 8; n = 187) and high risk of IHD (score from 9-13; n = 125). Prevalence of IHD in each group was respectively of 0%, 6.7%, 58.5%. Reliability of the model seems satisfactory as the model developed from the derivation set predicted perfectly (p = 0.948) the number of patients in each group in the validation set. Conclusion: This clinical score based only on history and physical exams can be an important tool in the practice of the general physician for the prediction of ischemic heart disease in patients complaining of chest pain. The score below 6 points (in more than half of our population) can avoid demanding complementary exams for selected patients (ECG, laboratory tests) because of the very low risk of IHD. Score above 6 points needs investigation to detect or rule out IHD. Further external validation is required in ambulatory settings.
Resumo:
Although p53-gene mutations occur with significant frequency in diffuse low-grade and high-grade astrocytomas, and are postulated to play an important role in tumorigenesis in these cases, the role of the p53 gene in pilocytic astrocytomas remains unclear. Published data using DNA-based assays for p53-gene analysis in these tumors have shown contradictory results in mutation frequency (0-14%). It is not known whether these heterogeneous results stem from the biological diversity of this tumor group or from technical problems. To re-evaluate p53-gene status in pilocytic tumors, we analyzed 18 tumors chosen to represent the clinical and biological heterogeneity of this tumor type with respect to anatomical location, patient age, gender, ethnic origin (Caucasian or Japanese) and the concomitant occurrence of neurofibromatosis type 1 (NF1). All primary tumors were histologically diagnosed as pilocytic astrocytoma (WHO grade I), except for one anaplastic pilocytic astrocytoma (WHO grade III) which developed in an NF1 patient and recurred as glioblastoma multiforme (WHO grade IV). p53 mutations were detected using an assay in yeast which tests the transcriptional activity of p53 proteins synthesized from tumor mRNA-derived p53-cDNA templates. None of 18 tumors, including 3 NF1-related tumors, showed p53-gene mutations between and including exons 4 and 11. We conclude that p53-gene mutations are extremely rare findings in pilocytic astrocytomas, and are absent even in those exceptional cases in which malignant progression of such tumors has occurred.