182 resultados para Jaw Fixation Techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to review our experience in percutaneous endoscopic gastrostomy (PEG) performed in patients with cancer of the upper aerodigestive tract. Descriptive retrospective study of 142 patients (115 males, 27 females), mean age 62.4 years (25-84 years), with head and neck or esophageal cancer, who underwent PEG tube insertion between January 2006 and December 2008. The studied parameters were indications, success rate, rate and type of complications, and their management. Percutaneous endoscopic gastrostomy was inserted before chemoradiation therapy in 80% and during or after cancer treatment in 20% of the patients. PEG placement was possible in 137 patients (96%). Major complications were observed in 9 (7%) and minor complications in 22 (17%) of the 137 patients. Seven of the 9 patients with a major complication needed revision surgery. The mortality directly related to the procedure was 0.7%. Percutaneous endoscopic gastrostomy tube insertion has a high success rate. In patients with upper aerodigestive tract cancer, PEG should be the first choice for enteral nutrition when sufficient oral intake is not possible. Although apparently easy, the procedure may occasionally lead to severe complications. Therefore, a strict technique and knowledge of clinical signs of possible complications are mandatory.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess the specific risks of injury to neural and vascular structures inherent in two approaches to transobturator surgery for inserting a suburethral sling, i.e. the outside-in (standard technique) and inside-out approaches. MATERIALS AND METHODS The study comprised seven cadavers, providing 14 obturator regions. Five specimens had a tape inserted outside-in on one side, and inside-out on the other; of the remaining two cadavers, one had an inside-out tape and one an outside-in tape, bilaterally. After tape insertion, the cadavers were dissected. Particular attention was paid to the distances between the tape and the deep external pudendal vessels, and between the tape and the posterior branch of the obturator nerve. RESULTS With the inside-out technique, the safety margins were reduced, and the external pudendal vessels and the posterior branch of the obturator nerve were at greater risk of injury. CONCLUSION The two techniques are not equivalent, with a lower risk of injury to vascular and nerve structures with the outside-in technique.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In Alzheimer's disease (AD) the olfactory system, including the olfactory bulb, a limbic paleocortex is severely damaged. The occurrence of early olfactory deficits and the presence of senile plaques and neurofibrillary tangles in olfactory bulb were reported previously by a few authors. The goal of the present study was to analyze the occurrence of AD-type degenerative changes in the peripheral part of the olfactory system and to answer the question whether the frequency and severity of changes in the olfactory bulb and tract are associated with those of the cerebral cortex in AD. MATERIAL AND METHODS: In 110 autopsy cases several cortical areas and the olfactory bulb and tract were analyzed using histo- and immunohistochemical techniques. Based on a semiquantitative analysis of cortical senile plaques, neurofibrillary tangles and curly fibers, the 110 cases were divided into four groups: 19 cases with severe (definite AD), 14 cases with moderate, 58 cases with discrete and 19 control cases without AD-type cortical changes. RESULTS: The number of cases with olfactory involvement was very high, more than 84% in the three groups with cortical AD-type lesions. Degenerative olfactory changes were present in all 19 definite AD cases, and in two of the 19 controls. The statistical analysis showed a significant association between the peripheral olfactory and cortical degenerative changes with respect to their frequency and severity (P < 0.001). Neurofibrillary tangles and neuropil threads appear in the olfactory system as early as in entorhinal cortex. CONCLUSION: The results indicate a close relationship between the olfactory and cortical degenerative changes and indicate that the involvement of the olfactory bulb and tract is one of the earliest events in the degenerative process of the central nervous system in AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Résumé de l'ouvrage) Dans cet ouvrage réunissant théologiens et philosophes, le corps contemporain est pensé par rapport à ce qui l'excède, ce qui le met en scène, ce qui le reprend, ce qui le transforme aujourd'hui. Dans une première partie, l'ouvrage propose des éclairages sur le corps à partir de ce qui met en question sa vision strictement rationnelle. Puis, trois auteurs évoquent les différentes manières dont la Bible, la philosophie et la littérature contemporaine mettent en scène les corps. Dans une troisième partie, sont abordées des questions plus spécifiquement reliées à la tradition catholique, au christianisme primitif et à la pratique de l'ascèse. Enfin, quatre contributions explorent le défi posé par la déréalisation du corps dans nos sociétés d'aujourd'hui, avec, pour clore l'ensemble, une réflexion sur le dualisme qui traverse le questionnement sur le corps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Odor detection and discrimination by olfactory systems in vertebrates and invertebrates depend both on the selective expression of individual olfactory receptor genes in subpopulations of olfactory sensory neurons, and on the targeting of the encoded proteins to the exposed, ciliated endings of sensory dendrites. Techniques to visualize the expression and localization of olfactory receptor gene products in vivo have been essential to reveal the molecular logic of peripheral odor coding and to permit investigation of the developmental and cellular neurobiology of this sensory system. Here, we describe methods for detection of olfactory receptor transcripts and proteins in the antennal olfactory organ of the fruit fly, Drosophila melanogaster, an important genetic model organism. We include protocols both for antennal cryosections and whole-mount antennae. These methods can be adapted for detection of receptor expression in other olfactory and gustatory tissues in Drosophila, as well as in the chemosensory systems of other insects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).