133 resultados para Initial solution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An image analysis method is presented which allows for the reconstruction of the three-dimensional path of filamentous objects from two of their projections. Starting with stereo pairs, this method is used to trace the trajectory of DNA molecules embedded in vitreous ice and leads to a faithful representation of their three-dimensional shape in solution. This computer-aided reconstruction is superior to the subjective three-dimensional impression generated by observation of stereo pairs of micrographs because it enables one to look at the reconstructed molecules from any chosen direction and distance and allows quantitative analysis such as determination of distances, curvature, persistence length, and writhe of DNA molecules in solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Le captopril, inhibiteur de l'enzyme de conversion de l'angiotensine, est largement utilisé dans le traitement de l'hypertension artérielle et de l'insuffisance cardiaque chez l'adulte et l'enfant . De par son instabilité en milieu aqueux (oxydation en captopril disulfure), il n'est actuellement commercialisé que sous forme de comprimés. La prescription fréquente de doses faibles et variables en pédiatrie justifiait le développement d'une forme orale liquide, tant sur le plan pratique et économique, que sur celui de la sécurité d'administration. Cependant toutes les formulations orales liquides publiées présentent une stabilité courte, ne dépassant guère 1 mois. Objectif: Développer une forme orale liquide de captopril d'une stabilité d'au moins 6 mois. Méthode: Sur la base des données de la littérature, élaboration de 8 formulations liquides différentes de captopril 1 mg/ml (concentration permettant le prélèvement d'un volume adéquat pour une administration en pédiatrie). Mise au point d'une « stability indicating method » par HPLC par des tests de dégradation accélérée à la chaleur (100°C), en milieu acide, basique, en présence d'un agent oxydant et de la lumière. Sélection de la formulation la plus stable durant le premier mois. Etude de stabilité sur 2 ans de 3 lots (3 échantillons/lot) dans leur conditionnement final à température ambiante (TA), au frigo et à 40° ± 2°C. Contrôle microbiologique au début et à la fin de l'étude selon la méthode de la Ph. Eur. (Ed. 3). Résultats: La formule retenue est une solution aqueuse de captopril 1 mg/ml additionnée d'EDTA 1 mg/ml comme stabilisateur et conditionnée dans des flacons VERAL en verre brun de 60 ml. Après dégradation dans les conditions définies ci-dessus, le pic du captopril est nettement séparé sur les chromatogrammes de ceux des produits de dégradation. Après 2 ans, la concentration mesurée est de 104.6% (±0.32%) au frigo, 103.6% (±0.86%) à TA et 96.5 % (±0.02%) à 40°C. Aucune croissance n'a été observée sur la durée de l'étude. Discussion et conclusion: La solution de captopril 1 mg/ml mise au point est simple à préparer. En partant du principe actif pur et en présence d'EDTA comme complexant, les traces de métaux éventuellement présents n'induisent pas l'oxydation du captopril et par conséquent le recours à d'autres stabilisateurs n'est pas nécessaire. La méthode HPLC développée est une « stability indicating method ». Les résultats de l'étude ont montré que cette solution a une durée de validité de 2 ans au frigo et à TA. Compte tenu du fait que la préparation ne contient pas d'agent antimicrobien, une conservation au frigo (2 - 8°C) est toutefois recommandée. La formule proposée présente un réel avantage en pédiatrie tant sur le plan de la sécurité d'administration que sur celui de l'économie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven tesla (T) MR imaging is potentially promising for the morphologic evaluation of coronary arteries because of the increased signal-to-noise ratio compared to lower field strengths, in turn allowing improved spatial resolution, improved temporal resolution, or reduced scanning times. However, there are a large number of technical challenges, including the commercial 7 T systems not being equipped with homogeneous body radiofrequency coils, conservative specific absorption rate constraints, and magnified sample-induced amplitude of radiofrequency field inhomogeneity. In the present study, an initial attempt was made to address these challenges and to implement coronary MR angiography at 7 T. A single-element radiofrequency transmit and receive coil was designed and a 7 T specific imaging protocol was implemented, including significant changes in scout scanning, contrast generation, and navigator geometry compared to current protocols at 3 T. With this methodology, the first human coronary MR images were successfully obtained at 7 T, with both qualitative and quantitative findings being presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: A hybrid intervention is a joint procedure involving the interventional cardiologist and the cardiac surgeon. At our institution we have opted for this type of approach in congenital heart disease since 2005. We report here our initial experience. Cases: 1. A 3 year old boy with double aortic arch and multiple muscular ventricular septal defects (VSD),was readdressed for pulmonary band (PAB) removal and residual VSD closure after previous palliation. After surgical removal of the PAB, the surgeon provided a minimal transventricular access for placement of a 6mm Amplatzer® muscular VSD occluder by the cardiologist under transoesophageal guidance. The patient was extubated the same day and discharged after 5 days. 2. An 8 year old girl with Williams syndrome was followed for two large VSDs and severe peripheral pulmonary arteries (PA) stenosis. The membranous VSD was closed surgically, the muscular VSD during the same operation by direct placement of a 12 mm Amplatzer® muscular VSD occluder. During rewarming, balloon angioplasty of peripheral PA stenosis was achieved under fluoroscopy. Patient was extubated the following day and discharged after 8 days. 3. A 9 year old boy post tetralogy of Fallot repair had severe distal stenosis of the right ventricular to PA conduit.With patient on partial cardiopulmonary bypass, an incision was made on the conduit and a CP 8 Zig 16 stent placed on the stenosis. The child passed on full bypass and the definitive placement of the stent achieved. The child was extubated at the end of the intervention and discharged after 6 days. 4. A newborn presented at 2 days life with complex aortic arch anatomy: left aortic arch and right descending thoracic aorta perfused directly from a right arterial duct and left PA atresia. The arterial duct was stented with a Genesis XD stent dilated at 7mm. Two days later the cardiac surgeon made banded the right PA. The child was extubated after the operation and discharged a week later. Conclusion: Hybrid approach opens new ways of correction or palliation in congenital heart disease with encouraging results and less morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

rejection can lead to loss of function. Histological reading of endomyocardial biopsy remains the "gold standard" for guiding immunosuppression, despite its methodological limitations (sampling error and interobserver variability). The measurement of the T2 relaxation time has been suggested for detection of allograft rejection, on the pathophysiological basis that the T2 relaxation time prolongs with local edema resulting from acute allograft rejection. Using breath-held cardiac magnetic resonance T2 mapping at 1.5 T, Usman et al. (CircCardiovascImaging2012) detected moderate allograft rejection (grade 2R, ISHLT 2004). With modern immunosuppression grade 2R rejection has become a rare event, but the need remains for a technique that permits the discrimination of absent (grade 0R) and mild rejection (grade 1R). We therefore investigated whether an increase of magnetic field strength to 3T and the use of real-time navigator-gated respiration compensation allow for an increase in the sensitivity of T2 relaxation time detection that is necessary to achieve this discrimination. Methods: Eighteen patients received EMB (Tan et al., ArchPatholLabMed2007) and cardiac T2 mapping on the same day. Reading of T2 maps was blinded to the histological results. For final analysis, 3 cases with known 2R rejection at the time of T2 mapping were added, yielding 21 T2 mapping sessions. A respiration-navigator-gated radial gradient-recalled-echo pulse sequence (resolution 1.17 mm2, matrix 2562, trigger time 3 heartbeats, T2 preparation duration TET2 Prep = 60/30/0 ms) was applied to obtain 3 short-axis T2 maps (van Heeswijk et al., JACCCardiovascImaging2012), which were segmented according to AHA guidelines (Cerqueira et al, Circulation2001). The highest segmental T2 values were grouped according to histological rejection grade and differences were analyzed by Student's t-test, except for the non-blinded cases with 2R rejection. The degree of discrimination was determined using the Spearman's ranked correlation test. Results: The high-quality T2 maps allowed for visual differentiation of the rejection degrees (Figure 1), and the correlation of T2 mapping with the histological grade of acute cellular rejection was significant (Spearman's r = 0.56, p = 0.007). The 0R (n = 15) and 1R (n = 3) degrees demonstrated significantly different T2 values (46.9 ± 5.0 and 54.3 ± 3.0 ms, p = 0.02, Figure 2). Cases with 2R rejection showed clear T2 elevation (T2 = 60.3 ± 16.2 ms). Conclusions: This pilot study demonstrates that non-invasive free-breathing cardiac T2 mapping at 3T discriminates between no and mild cardiac allograft rejection. Confirmation of these encouraging results in a larger cohort should consider a study able to show equivalency or superiority of T2 mapping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The major task of policy makers and practitioners when confronted with a resource management problem is to decide on the potential solution(s) to adopt from a range of available options. However, this process is unlikely to be successful and cost effective without access to an independently verified and comprehensive available list of options. There is currently burgeoning interest in ecosystem services and quantitative assessments of their importance and value. Recognition of the value of ecosystem services to human well-being represents an increasingly important argument for protecting and restoring the natural environment, alongside the moral and ethical justifications for conservation. As well as understanding the benefits of ecosystem services, it is also important to synthesize the practical interventions that are capable of maintaining and/or enhancing these services. Apart from pest regulation, pollination, and global climate regulation, this type of exercise has attracted relatively little attention. Through a systematic consultation exercise, we identify a candidate list of 296 possible interventions across the main regulating services of air quality regulation, climate regulation, water flow regulation, erosion regulation, water purification and waste treatment, disease regulation, pest regulation, pollination and natural hazard regulation. The range of interventions differs greatly between habitats and services depending upon the ease of manipulation and the level of research intensity. Some interventions have the potential to deliver benefits across a range of regulating services, especially those that reduce soil loss and maintain forest cover. Synthesis and applications: Solution scanning is important for questioning existing knowledge and identifying the range of options available to researchers and practitioners, as well as serving as the necessary basis for assessing cost effectiveness and guiding implementation strategies. We recommend that it become a routine part of decision making in all environmental policy areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A few studies have suggested an association between prenatal exposure to methylmercury and decreased heart rate variability (HRV) related to autonomic heart function, but no study has examined this association using baroreflex sensitivity (BRS). In this study we assessed the distribution of BRS and immediate orthostatic hypotension (IOH) in young Seychellois adults and their associations with exposure to prenatal and recent postnatal methylmercury. METHODS: Subjects in the Seychelles Child Development Study (SCDS) main cohort were evaluated at age 19 years. Non-invasive beat-to-beat blood pressure (BP) monitoring (Finapres, Ohmeda) was performed at rest and during active standing in 95 consecutive subjects. Recent postnatal mercury exposure was measured in subjects' hair at the age of 19 years and prenatal exposure in maternal hair grown during pregnancy. BRS was estimated by sequence analysis to identify spontaneous ascending and descending BP ramps. HRV was estimated by the following markers: PNN50 (relative numbers of normal-to-normal intervals which are shorter by more than 50 ms than the immediately following normal-to-normal intervals); rMSSD (root mean of the squared sum of successive interval differences); LF/HF (low frequency/high frequency component ratio); ratio of the mean expiratory/inspiratory RR intervals (EI ratio); and the ratio between the longest RR interval 30 s after active standing and the shortest RR interval at 15 s (Max30/Min15). IOH was estimated by the deepest BP fall within the first 15 s after active standing up. RESULTS: Prenatal MeHg exposures were similar in boys and girls (6.7±4.3, 6.7±3.8 ng/g) but recent postnatal mercury levels were higher in males than females (11.2±5.8 vs 7.9±4.3 ng/g, p=0.003). Markers of autonomic heart rate control were within the normal range (BRS: 24.8±7 ms/mm Hg, PNN50: 24.9±6.8%, rMSSD: 68±22, LF/HF: 0.61±0.28) in both sexes. After standing, 51.4% of subjects had a transient systolic BP drop>40 mm Hg, but only 5.3% reported dizziness or had syncope. Prenatal and recent postnatal MeHg levels, overall, were not associated with BRS, E/I ratio, PNN50, rMSSD, LF/HF ratio, Max30/Min15 ratio, and IOH. CONCLUSIONS: This study provides no support for the hypothesis that prenatal or recent postnatal MeHg exposure from fish consumption is associated with impaired autonomic heart rate control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. METHODS: A free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. RESULTS: The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3) . Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. CONCLUSION: The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.