401 resultados para Complication
Resumo:
Peri-insular hemispherotomy is a surgical technique used in the treatment of drug-resistant epilepsy of hemispheric origin. It is based on the exposure of insula and semi-circular sulci, providing access to the lateral ventricle through a supra- and infra-insular window. From inside the ventricle, a parasagittal callosotomy is performed. The basal and medial portion of the frontal lobe is isolated. Projections to the anterior commissure are interrupted at the time of amygdala resection. The hippocampal tail and fimbria-fornix are disrupted posteriorly. We report our experience of 18 cases treated with this approach. More than half of them presented with congenital epilepsy. Neuronavigation was useful in precisely determining the center and extent of the craniotomy, as well as the direction of tractotomies and callosotomy, allowing minimal exposure and blood loss. Intra-operative monitoring by scalp EEG on the contralateral hemisphere was used to follow the progression of the number of interictal spikes during the disconnection procedure. Approximately 90% of patients were in Engel's Class I. We observed one case who presented with transient postoperative neurological deterioration probably due to CSF overdrainage and documented one case of incomplete disconnection in a patient presenting with hemimegalencephaly who needed a second operation. We observed a good correlation between a significant decrease in the number of spikes at the end of the procedure and seizure outcome. Peri-insular hemispherotomy provides a functional disconnection of the hemisphere with minimal resection of cerebral tissue. It is an efficient technique with a low complication rate. Intra-operative EEG monitoring might be used as a predictive factor of completeness of the disconnection and consequently, seizure outcome.
Resumo:
Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.
Resumo:
BACKGROUND: Long-lasting food impactions requiring endoscopic bolus removal occur frequently in patients with eosinophilic esophagitis (EoE) and harbor a risk for severe esophageal injuries. We evaluated whether treatment with swallowed topical corticosteroids is able to reduce the risk of occurrence of this complication. METHODS: We analyzed data from the Swiss EoE Cohort Study. Patients with yearly clinic visits, during which standardized assessment of symptoms, endoscopic, histologic, and laboratory findings was carried out, were included. RESULTS: A total of 206 patients (157 males) were analyzed. The median follow-up time was 5 years with a total of 703 visits (mean 3.41 visits/patient). During the follow-up period, 33 patients (16 % of the cohort) experienced 42 impactions requiring endoscopic bolus removal. We evaluated the following factors regarding the outcome 'bolus impaction' by univariate logistic regression modeling: swallowed topical corticosteroid therapy (OR 0.503, 95%-CI 0.255-0.993, P = 0.048), presence of EoE symptoms (OR 1.150, 95%-CI 0.4668-2.835, P = 0.761), esophageal stricture (OR 2.832, 95%-CI 1.508-5.321, P = 0.001), peak eosinophil count >10 eosinophils/HPF (OR 0.724, 95%-CI 0.324-1.621, P = 0.433), blood eosinophilia (OR 1.532, 95%-CI 0.569-4.118, P = 0.398), and esophageal dilation (OR 1.852, 95%-CI 1.034-3.755, P = 0.017). In the multivariate model, the following factors were significantly associated with bolus impaction: swallowed topical corticosteroid therapy (OR 0.411, 95%-CI 0.203-0.835, P = 0.014) and esophageal stricture (OR 2.666, 95%-CI 1.259-5.645, P = 0.01). Increasing frequency of use of swallowed topical steroids was associated with a lower risk for bolus impactions. CONCLUSIONS: Treatment of EoE with swallowed topical corticosteroids significantly reduces the risk for long-lasting bolus impactions.
Resumo:
Objective. Mandibular osteoradionecrosis (ORN) is a serious complication of radiotherapy (RT) in head and neck cancer patients. The aim of this study was to analyze the incidence of and risk factors for mandibular ORN in squamous cell carcinoma (SCC) of the oral cavity and oropharynx.Study Design. Case series with chart review.Setting. University tertiary care center for head and neck oncology.Subjects and Methods. Seventy-three patients treated for stage I to IV SCC of the oral cavity and oropharynx between 2000 and 2007, with a minimum follow-up of 2 years, were included in the study. Treatment modalities included both RT with curative intent and adjuvant RT following tumor surgery. The log-rank test and Cox model were used for univariate and multivariate analyses.Results. The incidence of mandibular ORN was 40% at 5 years. Using univariate analysis, the following risk factors were identified: oral cavity tumors (P < .01), bone invasion (P < .02), any surgery prior to RT (P < .04), and bone surgery (P < .0001). By multivariate analysis, mandibular surgery proved to be the most important risk factor and the only one reaching statistical significance (P < .0002).Conclusion. Mandibular ORN is a frequent long-term complication of RT for oral cavity and oropharynx cancers. Mandibular surgery before irradiation is the only independent risk factor. These aspects must be considered when planning treatment for these tumors.
Resumo:
BACKGROUND: Infectious keratitis after PRK remains a rare but potentially devastating complication. HISTORY AND SIGNS: Medical records of 3 male patients with infectious keratitis after uneventful PRK for myopia and astigmatism were reviewed retrospectively. PRK was performed using the Wavelight Allegretto excimer laser. Postoperative care included a bandage contact lens (BCL) for 5 days, topical antibiotics, ketorolac, and artificial tears. THERAPY AND OUTCOME: Keratitis presented 2 - 4 days postoperatively. In one case, each culture was negative (case 1), and was positive for Streptococcus pneumoniae (case 2) and Staphylococcus aureus (case 3). Final BSCVA (best spectacle corrected visual acuity) after intensive antibiotic treatment and removal of BCL were 1.0 (case 1), 0.9 (case 2) and 0.3 correctable to 0.8 with pinhole (case 3). CONCLUSIONS: Postoperative broad-spectrum antibiotics are mandatory after PRK to prevent infectious keratitis. However, resistant organisms are more and more common. The presence of a bandage soft contact lens after surgery is an unfavourable element that may increase risk of infection. Based on our case series, we suggest limiting soft contact lens wear during the two postoperative days even if the corneal ulceration is not healed.
Resumo:
The neurogenic shock is a common complication of spinal cord injury, especially when localized at the cervical level. Characterized by a vasoplegia (hypotension) and bradycardia, the neurogenic shock is secondary to the damage of the sympathetic nervous system. The clinical presentation often includes tetraplegia, with or without respiratory failure. Early treatment aims to minimize the occurrence of secondary spinal cord lesions resulting from systemic ischemic injuries. Medical management consists in a standardized ABCDE approach, in order to stabilize vital functions and immobilize the spine. The hospital care includes performing imaging, further measures of neuro-resuscitation, and coordinated surgical assessment and treatment of any other injury.
Resumo:
Infections after total joint arthroplasty are rare but come with severe consequences. Timely, adequate and standardized treatment beginning at the onset of symptoms will have a major impact on the handling of this dreaded complication. In absences of clear guidelines, errors are often committed, with occasionally severe consequences for the patient. In this article, the 10 most frequent errors starting with diagnostics till antibiotic and surgical treatment will be discussed.
Resumo:
Spinal cord compression due to cervical exostoses is a rare but recognized complication of hereditary multiple exostosis (HME), an autosomal dominant disorder. This disease, also called multiple osteochondromatosis, is characterised by osteocartilaginous exostoses, typically involving the juxtaepiphyseal regions of long bones. Complications such as transformation to sarcoma (1 to 5%) or neurological compression (of the spinal cord, 1 to 9%) can arise during the course of the disease. We report the case of a 64-year-old man with progressive difficulties in walking over many years, ascribed to congenital rachitism. A diagnosis of HME was not made until late in the disease course. Investigations revealed cervical myelopathy due to vertebral exostosis as well as multiple exostoses in other sites. His gait was not improved after surgical decompression. A better knowledge of this disease could have prevented this neurological complication.
Resumo:
BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.
Resumo:
Cocaine use, often not recognized, is a frequent cause of consultation in the emergency room or by primary care physicians. The use of cocaine causes numerous cardiovascular and pulmonary side effects. In this context, the occurrence of a pneumothorax represents a specific complication, often misunderstood by primary care physicians. We describe here three cases of patients who suffered from subcutaneous emphysema and pneumothorax after taking cocaine and emphasize the importance of always keeping in mind the possibility of illicit substance use in such cases, especially among young and healthy patients.
Resumo:
La pose d'un cathéter veineux central peut se faire par plusieurs abords. La connaissance de l'anatomie, du matériel, la maîtrise des détails de la procédure pour chaque type d'abord et une attention particulière à l'asepsie sont des prérequis importants pour limiter les risques de complications et pour donner une information complète et exhaustive au patient. Cet article peut être utilisé comme base pour le développement d'une check-list, utile pour les médecins qui doivent procéder à la pose d'un cathéter veineux central mais qui ne possèdent pas encore une maîtrise du geste. Several approaches exist for central vein catheterization. Mastery of the various steps of this procedure and understanding of the basics of asepsis are critical to prevent any complication. They also built the basis for an exhaustive communication with the patient, to obtain an informed consent. This article can in addition be used to develop a checklist in order to (self-)assess competence in procedural skills
Resumo:
BACKGROUND: Anaemia represents a common complication of inflammatory bowel disease (IBD). Most studies on anaemia in IBD patients have been performed in tertiary referral centres (RC) and data from gastroenterologic practices (GP) are lacking. We investigated the frequency and severity of anaemia in IBD patients from tertiary referral centres and gastroenterologic practices compared to the general population. METHODS: Data were acquired from patients included in the Swiss IBD Cohort Study. IBD activity was evaluated by CDAI and modified Truelove and Witts severity index (MTWSI). Anaemia was defined as haemoglobin ≤120g/L in women and ≤130g/L in men. RESULTS: 125 patients from RC (66 with Crohn's disease (CD) and 59 with ulcerative colitis (UC)) and 116 patients from GP (71 CD and 45 UC) were included and compared to 6074 blood donors. Anaemia was found in 21.2% (51/241) of the IBD patients and more frequently in patients from RC as compared to GP and healthy controls (28.8% vs. 12.9% vs. 3.4%; P<0.01). IBD patients from RC suffered more frequently from active disease compared to IBD patients in GP (36% vs. 23%, P=0.032). Supplementation therapy (iron, vitamin B12, folic acid) was performed in 40% of anaemic IBD patients in GP as compared to 43% in RC. CONCLUSIONS: Anaemia is a common complication in patients with IBD and significantly more prevalent in patients from referral centres as compared to patients from gastroenterologic practices. Physicians treating IBD patients should pay attention to the presence of anaemia and ensure sufficient supplementation therapy.
Resumo:
RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.
Resumo:
Glucocorticoïds are widely used in medicine and associated with numerous complications. Whenever possible, dosage reduction or treatment withdrawal should be considered as soon as possible depending on the underlying disease being treated. Administration of glucocorticoids induces a physiologic negative feed-back on the hypothalamic-pituitary-adrenal (HPA) axis and three clinical situations can be distinguished during treatment withdrawal: reactivation of the disease for which the glucocorticoids were prescribed, acute adrenal insufficiency and steroid withdrawal syndrome. Acute adrenal insufficiency is a feared complication but probably rare. It is usually seen during stress situations and can be observed long after steroid withdrawal. There is no good predictive marker to anticipate acute adrenal insufficiency and clinical evaluation of the patient remains a key element in its diagnosis. If adrenal insufficiency is suspected, HPA suppression can be assessed with dynamic tests. During stress situation, steroid administration is then recommended depending on the severity of the stress.
Resumo:
RESUME L'objectif de ce travail est de rappeler l'historique des hépatectomies majeures, les bases anatomiques et les techniques opératoires de la chirurgie du foie. Puis, à partir de 212 cas d'exérèses majeures recencées entre 1992 et 2001 dans le service de Chirurgie Viscérale du CHUV, les facteurs de risques, la mortalité et la morbidité des hépatectomies majeures seront étudiés et comparés avec les données récentes de la littérature. L'anatomie hépatique peut être considérée de plusieurs façons morphologiquement (poids, faces, lobe droit, gauche et caudé...), fonctionnellement (segmentation en fonction de la distribution des pédicules portes et de la localisation des veines hépatiques) et chirurgicalement. La terminologie est rappelée (hépatectomies «typique », «atypique », «réglée », «majeure »...). A partir de ces données, les exérèses du foie sont ensuite classées. Les techniques d'hépatectomies sont expliquées, en rappelant les principes généraux, et les voies d'abord. Puis, les techniques de contrôle de l'hémostase, la reconstruction des voies biliaires, les méthodes utilisées par rapport à la tranche de section hépatique et à la loge d'hépatectomie sont discutées, Les acquisitions récentes sont abordées. Sur les 494 hépatecomies réalisées entre janvier 1992 et août 2001, 212 sont majeures. Elles sont reparties en 7 groupes selon l'exérèse (lobectomie G ou D, hépatecomie G ou D etc...). `Sur ces 212 résections, 177 cas concernaient des lésions malignes et 35 cas des lésions bénignes. Les indications ont été classées en 4 groupes : cancer primitif du foie, métastases hépatiques, maladies bénignes (par exemple l'échinococcose alvéolaire), et 8 cas classés dans le groupe «autres ». Une intervention en urgence a été réalisée dans 7 cas. Le bilan préopératoire comprend un bilan biologique et morphologique. Une embolisation de l'artère hépatique a été réalisées dans 6 cas, alors qu'une embolisation dans la veine porte a été faite dans 17 cas. Les modalités chirurgicales (voies d'abord, contrôle vasculaire, drainage biliaire post- opératoire, transfusions per- opératoires, et interventions extra- hépatiques) sont expliqués. En fin, les méthodes statistiques utilisées sont rappelées. Il n'y a pas eu de décès per- opératoire. La mortalité post- opératoire dans les 30 jours a été de 3,3 % (7 cas) et la mortalité globale hospitalière de 5,2 %. Dans cette série, 132 patients n'ont eu aucune complication. La morbidité est de 17% si on considère les complications majeures, ayant concerné 36 patients, mais de 37,75 si l'on considère toutes les complications. Les complications chirurgicales sont le faite d'hémorragie, de fuite biliaire et d'infection du foyer opératoire. Dans notre étude, 33 facteurs de risque ont été analysés. L'analyse statistique uni- variée met den évidence les facteurs de risque suivants : Le nombre de culots de sang transfusés, la présence d'une hépatite, celle d'une cirrhose, le tabagisme, la lobectomie droite, et la présence d'une hypertension artérielle. L'analyse multi variée réalisée a permis de faire ressortir une combinaison de facteur de risque avec une valeur statistique significative et de réaliser une échelle et un score de gravité en fonction des facteurs de risques obtenus dans l'analyse uni variée. Le taux de mortalité globale hospitalière obtenu dans notre série (5,2%) est comparable aux résultats reportés dans d'autres séries.