126 resultados para Big Four Banks
Resumo:
Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.
Resumo:
In solid organ transplantation, ischemia/reperfusion (IR) injury during organ procurement, storage and reperfusion is an unavoidable detrimental event for the graft, as it amplifies graft inflammation and rejection. Intracellular mitogen-activated protein kinase (MAPK) signaling pathways regulate inflammation and cell survival during IR injury. The four best-characterized MAPK subfamilies are the c-Jun NH2-terminal kinase (JNK), extracellular signal- regulated kinase-1/2 (ERK1/2), p38 MAPK, and big MAPK-1 (BMK1/ERK5). Here, we review the role of MAPK activation during myocardial IR injury as it occurs during heart transplantation. Most of our current knowledge regarding MAPK activation and cardioprotection comes from studies of preconditioning and postconditioning in nontransplanted hearts. JNK and p38 MAPK activation contributes to myocardial IR injury after prolonged hypothermic storage. p38 MAPK inhibition improves cardiac function after cold storage, rewarming and reperfusion. Small-molecule p38 MAPK inhibitors have been tested clinically in patients with chronic inflammatory diseases, but not in transplanted patients, so far. Organ transplantation offers the opportunity of starting a preconditioning treatment before organ procurement or during cold storage, thus modulating early events in IR injury. Future studies will need to evaluate combined strategies including p38 MAPK and/or JNK inhibition, ERK1/2 activation, pre- or postconditioning protocols, new storage solutions, and gentle reperfusion.
Resumo:
Independent regulatory agencies are the institutional foundations of the regulatory state that, during the past 15 years, has gained prominence throughout Europe. This article studies the rise of independent authorities in European countries by comparing regulatory agencies and central banks. Delegation to independent central banks and to independent regulatory agencies is similar in many respects. In both cases, agents are deliberately made independent from political principals through a specific institutional design. Moreover, it has been argued that delegation to both central banks and regulatory agencies is linked to the need for policy-makers to improve the credibility of policy commitments, to the wish of incumbent politicians to tie the hands of future majorities, and to the extent to which the institutional contexts safeguard policy stability. Through an analysis of the formal independence of central banks and regulatory agencies in Western Europe, this article identifies an empirical puzzle that casts doubts on the accuracy of current explanations. Veto players and the uncertainty of incumbent policy-makers in respect to their re-election prospects matter for delegation to both central banks and regulatory agencies, but in opposite ways. Making sense of these anomalies is necessary to achieve a better understanding of delegation to independent authorities.
Resumo:
Two doses of synthetic atrial natriuretic peptide (0.5 and 5.0 micrograms/min) and its vehicle were infused intravenously for 4 hours in eight salt-loaded normal volunteers, and the effect on blood pressure, heart rate, renal hemodynamics, solute excretion, and secretion of vasoactive hormones was studied. The 0.5 micrograms/min infusion did not alter blood pressure or heart rate, whereas the 5.0 micrograms/min infusion significantly reduced the mean pressure by 20/9 mm Hg after 2.5 to 3 hours and increased the heart rate slightly. Inulin clearance was not significantly changed, but the mean p-aminohippurate clearance fell by 13 and 32% with the lower and higher doses, respectively. Urinary excretion of sodium and chloride increased slightly with the lower dose. With the higher dose, a marked increase in urinary excretion of sodium, chloride, and calcium was observed, reaching a peak during the second hour of the infusion. Potassium and phosphate excretion did not change significantly. A brisk increase in urine flow rate and fractional water excretion was seen only during the first hour of the high-dose infusion. Signs and symptoms of hypotension were observed in two subjects. No change in plasma renin activity, angiotensin II, or aldosterone was observed during either infusion, but a marked increase occurred after discontinuation of the high-dose infusion. In conclusion, the 5 micrograms/min infusion induced a transient diuretic effect, delayed maximal natriuretic activity, and a late fall in blood pressure, with no change in inulin clearance but a dose-related decrease in p-aminohippurate clearance. Despite large amounts of sodium excreted and blood pressure reduction, no counterregulatory changes were observed in the renin-angiotensin-aldosterone system or plasma vasopressin levels during the infusion.
Resumo:
This study presents the validation of a French version of the Career Adapt-Abilities Scale in four Francophone countries. The aim was to re-analyze the item selection and then compare this newly developed French-language form with the international form 2.0. Exploratory factor analysis was used as a tool for item selection, and confirmatory factor analysis (CFA) verified the structure of the CAAS French-language form. Measurement equivalence across the four countries was tested using multi-group CFA. Adults and adolescents (N=1,707) participated from Switzerland, Belgium, Luxembourg, and France. Items chosen for the final version of the CAAS French-language form are different to those in the CAAS international form 2.0 and provide an improvement in terms of reliability. The factor structure is replicable across country, age, and gender. Strong evidence for metric invariance and partial evidence for scalar invariance of the CAAS French-language form across countries is given. The CAAS French-language and CAAS international form 2.0 can be used in a combined form of 31 items. The CAAS French-language form will certainly be interesting for practitioners using interventions based on the life design paradigm or aiming at increasing career adapt-ability.
Resumo:
RATIONALE: Limited-channel portable monitors (PMs) are increasingly used as an alternative to polysomnography (PSG) for the diagnosis of obstructive sleep apnoea (OSA). However, recommendations for the scoring of PM recordings are still lacking. Pulse-wave amplitude (PWA) drops, considered as surrogates for EEG arousals, may increase the detection sensitivity for respiratory events in PM recordings. OBJECTIVES: To investigate the performance of four different hypopnoea scoring criteria, using 3% or 4% oxygen desaturation levels, including or not PWA drops as surrogates for EEG arousals, and to determine the impact of measured versus reported sleep time on OSA diagnosis. METHODS: Subjects drawn from a population-based cohort underwent a complete home PSG. The PSG recordings were scored using the 2012 American Academy of Sleep Medicine criteria to determine the apnoea-hypopnoea index (AHI). Recordings were then rescored using only parameters available on type 3 PM devices according to different hypopnoea criteria and patients-reported sleep duration to determine the 'portable monitor AHIs' (PM-AHIs). MAIN RESULTS: 312 subjects were included. Overall, PM-AHIs showed a good concordance with the PSG-based AHI although it tended to slightly underestimate it. The PM-AHI using 3% desaturation without PWA drops showed the best diagnostic accuracy for AHI thresholds of ≥5/h and ≥15/h (correctly classifying 94.55% and 93.27% of subjects, respectively, vs 80.13% and 87.50% with PWA drops). There was a significant but modest correlation between PWA drops and EEG arousals (r=0.20, p=0.0004). CONCLUSION: Interpretation of PM recordings using hypopnoea criteria which include 3% desaturation without PWA drops as EEG arousal surrogate showed the best diagnosis accuracy compared with full PSG.
Resumo:
The Swiss financial centre witnessed an important shift during the 1960s: the number of foreign banks and their importance in relation to the domestic banking sector significantly increased. Faced with this rapid development, Swiss bank representatives and political and monetary authorities reacted strongly. This paper investigates the evolution of the regulatory response by Swiss banking policy actors to the proliferation of foreign financial in- stitutions. In 1969, those reactions led to the adoption of a discriminatory regime, setting higher entry barriers for foreign banks than for domestic institutions. After examining possible reasons for the attractiveness of Switzerland to foreign banks, this paper will analyse the concerns and fears of the domestic banking sector and its regulators. In this regard, it appears that issues such as mere competition, preservation of the international reputation of the Swiss banks and anti-inflationary monetary policy were central to the chosen regulatory regime. Moreover, this paper shows that foreign banks were used as scapegoats in the evolution of the Swiss system of banking supervision. They were more tightly regulated, yet the general framework remained very lax.