110 resultados para Angles subtraction
Resumo:
This study investigated behavioral adaptability, which could be defined as a blend between stability and flexibility of the limbs movement and their inter-limb coordination, when individuals received informational constraints. Seven expert breaststroke swimmers performed three 200-m in breaststroke at constant submaximal intensity. Each trial was performed randomly in a different coordination pattern: 'freely-chosen', 'maximal glide' and 'minimal glide'. Two underwater and four aerial cameras enabled 3D movement analysis in order to assess elbow and knee angles, elbow-knee pair coordination, intra-cyclic velocity variations of the center of mass, stroke rate and stroke length and inter-limb coordination. The energy cost of locomotion was calculated from gas exchanges and blood lactate concentration. The results showed significantly higher glide, intra-cyclic velocity variations and energy cost under 'maximal glide' compared to 'freely-chosen' instructional conditions, as well as higher reorganization of limb movement and inter-limb coordination (p<0.05). In the 'minimal glide' condition, the swimmers did not show significantly shorter glide and lower energy cost, but they exhibited significantly lower deceleration of the center of mass, as well as modified limb movement and inter-limb coordination (p<0.05). These results highlight that a variety of structural adaptations can functionally satisfy the task-goal.
Resumo:
L'expérience LHCb sera installée sur le futur accélérateur LHC du CERN. LHCb est un spectromètre à un bras consacré aux mesures de précision de la violation CP et à l'étude des désintégrations rares des particules qui contiennent un quark b. Actuellement LHCb se trouve dans la phase finale de recherche et développement et de conception. La construction a déjà commencé pour l'aimant et les calorimètres. Dans le Modèle Standard, la violation CP est causée par une phase complexe dans la matrice 3x3 CKM (Cabibbo-Kobayashi-Maskawa) de mélange des quarks. L'expérience LHCb compte utiliser les mesons B pour tester l'unitarité de cette matrice, en mesurant de diverses manières indépendantes tous les angles et côtés du "triangle d'unitarité". Cela permettra de surdéterminer le modèle et, peut-être, de mettre en évidence des incohérences qui seraient le signal de l'existence d'une physique au-delà du Modèle Standard. La reconstruction du vertex de désintégration des particules est une condition fondamentale pour l'expérience LHCb. La présence d'un vertex secondaire déplacé est une signature de la désintégration de particules avec un quark b. Cette signature est utilisée dans le trigger topologique du LHCb. Le Vertex Locator (VeLo) doit fournir des mesures précises de coordonnées de passage des traces près de la région d'interaction. Ces points sont ensuite utilisés pour reconstruire les trajectoires des particules et l'identification des vertices secondaires et la mesure des temps de vie des hadrons avec quark b. L'électronique du VeLo est une partie essentielle du système d'acquisition de données et doit se conformer aux spécifications de l'électronique de LHCb. La conception des circuits doit maximiser le rapport signal/bruit pour obtenir la meilleure performance de reconstruction des traces dans le détecteur. L'électronique, conçue en parallèle avec le développement du détecteur de silicium, a parcouru plusieurs phases de "prototyping" décrites dans cette thèse.<br/><br/>The LHCb experiment is being built at the future LHC accelerator at CERN. It is a forward single-arm spectrometer dedicated to precision measurements of CP violation and rare decays in the b quark sector. Presently it is finishing its R&D and final design stage. The construction already started for the magnet and calorimeters. In the Standard Model, CP violation arises via the complex phase of the 3 x 3 CKM (Cabibbo-Kobayashi-Maskawa) quark mixing matrix. The LHCb experiment will test the unitarity of this matrix by measuring in several theoretically unrelated ways all angles and sides of the so-called "unitary triangle". This will allow to over-constrain the model and - hopefully - to exhibit inconsistencies which will be a signal of physics beyond the Standard Model. The Vertex reconstruction is a fundamental requirement for the LHCb experiment. Displaced secondary vertices are a distinctive feature of b-hadron decays. This signature is used in the LHCb topology trigger. The Vertex Locator (VeLo) has to provide precise measurements of track coordinates close to the interaction region. These are used to reconstruct production and decay vertices of beauty-hadrons and to provide accurate measurements of their decay lifetimes. The Vertex Locator electronics is an essential part of the data acquisition system and must conform to the overall LHCb electronics specification. The design of the electronics must maximise the signal to noise ratio in order to achieve the best tracking reconstruction performance in the detector. The electronics is being designed in parallel with the silicon detector development and went trough several prototyping phases, which are described in this thesis.
Resumo:
Background: Phacoemulsification is known to induce postoperative intraocular pressure (IOP) reduction, the degree of which varies according to glaucoma subtype and race. The authors set out to investigate the effect of cataract surgery on IOP, in a Swiss Caucasian population, and identify ocular predictive factors. Patients and Methods: 234 consecutive cases of 188 patients undergoing phacoemulsification between January 2011 and December 2012 were retrospectively reviewed and data collected. Exclusion criteria included acute angle closure, malignant glaucoma and pre-existing or subsequent glaucoma surgery. Pre- and post-operative visual acuity, IOP, gonioscopic findings, glaucoma medications, and laser treatments were recorded for eligible eyes. All eyes received the same postoperative regimen. Using multivariate analysis the predictive power of preoperative IOP, iridocorneal angle width, axial length on IOP reduction following phacoemulsification at months 3, 6 and 12 postoperatively were assessed. Eyes with narrow angles were compared against those with open angles. Results: 172 eyes of 121 patients met the inclusion criteria; mean age was 70.3 years (SD ± 10.7 years), with 77 males. Preoperatively median IOP was 16 mmHg (range 9-32 mmHg), mean number of glaucoma medications was 1.2 (SD ± 1.1), median visual acuity was 0.28 LogMAR (range 0-2.3LogMar). At 3 months post-operatively mean IOP decreased to 14 mmHg (p < 0.01) and remained statistically significantly reduced until 12 months, mean number of glaucoma medications was reduced to 1.0 and mean Snellen visual acuity increased to 0.8. Multivariate analysis revealed that pre-operative IOP and iridocorneal angle width (at 3 months) were significant predictive indicators of IOP reduction. At 12 months, IOP reduction was similar between open and narrow angle groups and total IOP reduction was no longer statistically significant. No intraoperative complications were recorded. Conclusions: Intraocular pressure reduction following phacoemulsification was greatest during the very early post-operative period, particularly in narrow angle patients. By one year, angle size was no longer predictive of IOP lowering, however pre-operative IOP and number of anti-glaucoma medications remained correlated with total IOP reduction.
Resumo:
The effects of footwear and inclination on running biomechanics over short intervals are well documented. Although recognized that exercise duration can impact running biomechanics, it remains unclear how biomechanics change over time when running in minimalist shoes and on slopes. Our aims were to describe these biomechanical changes during a 50-minute run and compare them to those observed in standard shoes. Thirteen trained recreational male runners ran 50 minutes at 65% of their maximal aerobic velocity on a treadmill, once in minimalist shoes and once in standard shoes, 1 week apart in a random order. The 50-minute trial was divided into 5-minute segments of running at 0%, +5%, and -5% of treadmill incline sequentially. Data were collected using photocells, high-speed video cameras, and plantar-pressure insoles. At 0% incline, runners exhibited reduced leg stiffness and plantar flexion angles at foot strike and lower plantar pressure at the forefoot and toes in minimalist shoes from minute 34 of the protocol onward. However, only reduced plantar pressure at the toes was observed in standard shoes. Overall, similar biomechanical changes with increased exercise time were observed on the uphill and downhill inclines. The results might be due to the unfamiliarity of subjects to running in minimalist shoes.
Resumo:
The present work was undertaken to investigate, in young healthy volunteers, the relationships between the forward propagation times of arterial pressure waves and the timing of reflected waves observable on the aortic pulse, in the course of rapid changes in body position. 20 young healthy subjects, 10 men, and 10 women, were examined on a tilt table at two different tilt angles, -10° (Head-down) and + 45° (Head-up). In each position, carotid-femoral (Tcf) and carotid-tibial forward propagation times (Tct) were measured with the Complior device. In each position also, the central aortic pressure pulse was recorded with radial tonometry, using the SphygmoCor device and a generalized transfer function, so as to evaluate the timing of reflected waves reaching the aorta in systole (onset of systolic reflected wave, sT1r) and diastole (mean transit time of diastolic reflected wave, dMTT). The position shift from Head-up to Head-down caused a massive increase in both Tct (women from 130 ± 10 to 185 ± 18 msec P < 0.001, men from 136 ± 9 to 204 ± 18 msec P < 0.001) and dMTT (women from 364 ± 35 to 499 ± 33 msec P < 0.001, men from 406 ± 22 to 553 ± 21 msec P < 0.001). Mixed model regression showed that the changes in Tct and dMTT observed between Head-up and Head-down were tightly coupled (regression coefficient 2.1, 95% confidence interval 1.9-2.3, P < 0.001). These results strongly suggest that the diastolic waves observed on central aortic pulses reconstructed from radial tonometric correspond at least in part to reflections generated in the lower limbs.