97 resultados para used equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Working in a NGO often involves providing life saving resources (food, medicine, equipment, water, etc) to needy populations around the globe. Such duty requires highly dedicated employees and humanitarian workers are said to face a hign degree of pressure in their daily work. Despite the evidence of taxing work demands, and a high potential for stress related problems, very few studies on occupational chronic stress have specifically looked at NGO workers. Assuming that "field stress" can relay to workers at headquarters, we carried out an exploratory study about occupational health among employees of a NGO's headquarters. We sent a questionnaire to all employees (N=130) of a NGO headquarters located in Switzerland. We used the TST questionnaire (French version of the Langner's questionnaire on psychiatric symptoms) to identify cases with potential mental health problems. We also included in the questionnaire some items about motivation, acknowledgment, work-life balance, job demand, and autonomy. A total of 75 employees answered our questionnaire (57% response rate). 44% of our sample were men (n=33) and 56% were women (n=42). The mean age was of 40 years (SD=7.6). 56% were working at the headquarters of the NGO in questions as of 2 years or less. Not surprisingly, a majority of respondents reported to be highly motivated (74%) and the meaning of work was important for 80% of them. However, 35% indicated having problems in conciliating their private and professional life. Most frequent reported symptoms included feeling "weak all over" (81%), having "trouble getting asleep often" (35%), "clogging in nose" (35%), feeling "nervous often" (33%), and "memory not all right" (33%). The score for psychiatric symptoms was high in 8 (11%) employees whose health might therefore be at risk. In comparison, other sudies showed that this proportion was 9% for French teachers and 16% for sales personnel1. Results show that symptoms of mental health problems do occur among NGO workers. Some of these symptoms are known to be linked to occupational stress. Chronic stress manifests itself first in non-specific symptoms (e.g. fatigue) and later in specific pathologies. This could explain the relatively low proportion of cases with a high score in Langner's scale than was expected. Therefore, we hypothesize a healthy worker effect. The fact that our sample is 40 years old in average, and that the turnover is quite high can also support this hypothesis. Further research is needed in order to better understand occupational stress in this specific population. An upcoming study will investigate the role of organizational factors associated with health complaints. Therefore, a longitudinal survey including quantitative and qualitative methods is appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Les tumeurs sont diverses et hétérogènes, mais toutes partagent la capacité de proliférer sans contrôle. Une prolifération dérégulée de cellules couplée à une insensibilité à une réponse apoptotique constitue une condition minimale pour que l'évolution d'une tumeur se produise. Un des traitements les plus utilisés pour traité le cancer à l'heure actuelle sont les chimiothérapies, qui sont fréquemment des composés chimiques qui induisent des dommages dans l'ADN. Les agents anticancéreux sont efficaces seulement quand les cellules tumorales sont plus aisément tuées que le tissu normal environnant. L'efficacité de ces agents est en partie déterminée par leur capacité à induire l'apoptose. Nous avons récemment démontré que la protéine RasGAP est un substrat non conventionnel des caspases parce elle peut induire à la fois des signaux anti et pro-apoptotiques, selon l'ampleur de son clivage par les caspases. A un faible niveau d'activité des caspases, RasGAP est clivé, générant deux fragments (le fragment N et le fragment C). Le fragment N semble être un inhibiteur général de l'apoptose en aval de l'activation des caspases. À des niveaux plus élevés d'activité des caspases, la capacité du fragment N de contrecarrer l'apoptose est supprimée quand il est clivé à nouveau par les caspases. Ce dernier clivage produit deux nouveaux fragments, N 1 et N2, qui contrairement au fragment N sensibilisent efficacement des cellules cancéreuses envers des agents chimiothérapeutiques. Dans cette étude nous avons prouvé qu'un peptide, appelé par la suite TAT-RasGAP317-326, qui est dérivé du fragment N2 de RasGAP et est rendu perméable aux cellules, sensibilise spécifiquement des cellules cancéreuses à trois génotoxines différentes utilisées couramment dans des traitements anticancéreux, et cela dans des modèles in vitro et in vivo. Il est important de noté que ce peptide semble ne pas avoir d'effet sur des cellules non cancéreuses. Nous avons également commencé à caractériser les mécanismes moléculaires expliquant les fonctions de sensibilisation de TAT-RasGAP317-326. Nous avons démontré que le facteur de transcription p53 et une protéine sous son activité transcriptionelle, nommée Puma, sont indispensables pour l'activité de TAT-RasGAP317-326. Nous avons également prouvé que TAT-RasGAP317-326 exige la présence d'une protéine appelée G3BP1, une protéine se liant a RasGAP, pour potentialisé les effets d'agents anticancéreux. Les données obtenues dans cette étude montrent qu'il pourrait être possible d'augmenter l'efficacité des chimiothérapies à l'aide d'un composé capable d'augmenter la sensibilité des tumeurs aux génotoxines et ainsi pourrait permettre de traiter de manière plus efficace des patients sous traitement chimiothérapeutiques. Summary Tumors are diverse and heterogeneous, but all share the ability to proliferate without control. Deregulated cell proliferation coupled with suppressed apoptotic sensitivity constitutes a minimal requirement upon which tumor evolution occurs. One of the most commonly used treatments is chemotherapy, which frequently uses chemical compounds that induce DNA damages. Anticancer agents are effective only when tumors cells are more readily killed than the surrounding normal tissue. The efficacy of these agents is partly determined by their ability to induce apoptosis. We have recently demonstrated that the protein RasGAP is an unconventional caspase substrate because it can induce both anti- and pro-apoptotic signals, depending on the extent of its cleavage by caspases. At low levels of caspase activity, RasGAP is cleaved, generating an N-terminal fragment (fragment N) and a C-terminal fragment (fragment C). Fragment N appears to be a general Mocker of apoptosis downstream of caspase activation. At higher levels of caspase activity, the ability of fragment N to counteract apoptosis is suppressed when it is further cleaved. This latter cleavage event generates two fragments, N1 and N2, which in contrast to fragment N potently sensitizes cancer cells toward DNA-damaging agents induced apoptosis. In the present study we show that a cell permeable peptide derived from the N2 fragment of RasGAP, thereafter called TAT-RasGAP317-326, specifically sensitizes cancer cells to three different genotoxins commonly used in chemotherapy in vitro and in vivo models. Importantly this peptide seems not to have any effect on non cancer cells. We have also started to characterize the molecular mechanisms underlying the sensitizing functions of TAT-RasGAP317-326. We have demonstrated that the p53 transcription factor and a protein under its transcriptional activity, called Puma, are required for the activity of TATRasGAP317-326. We have also showed that TAT-RasGAP317-326 requires the presence of a protein called G3BP1, which have been shown to interact with RasGAP, to increase the effect of the DNA-damaging drug cisplatin. The data obtained in this study showed that it is possible to increase the efficacy of current used chemotherapies with a compound able to increase the efficacy of genotoxins which could be beneficial for patients subjected to chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Determining a specific death cause may facilitate individualized therapy in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) decreased mortality in the Cardiac Resynchronization in Heart Failure trial by reducing pump failure and sudden cardiac death (SCD). This study analyzes predictors of specific causes of death. METHODS AND RESULTS: Univariate and multivariate analyses used 8 baseline and 3-month post-randomization variables to predict pump failure and SCD (categorized as "definite," "probable," and "possible"). Of 255 deaths, 197 were cardiovascular. There were 71 SCDs with a risk reduction by CRT of 0.47 (95% confidence interval 0.29-0.76; P = .002) with similar reductions in SCD classified as definite, probable, and possible. Univariate SCD predictors were 3-month HF status (mitral regurgitation [MR] severity, plasma brain natriuretic peptide [BNP], end-diastolic volume, and systolic blood pressure), whereas randomization to CRT decreased risk. Multivariate SCD predictors were randomization to CRT 0.56 (0.53-0.96, P = .035) and 3-month MR severity 1.82 (1.77-2.60, P = .0012). Univariate pump failure death predictors related to baseline HF state (quality of life score, interventricular mechanical delay, end-diastolic volume, plasma BNP, MR severity, and systolic pressure), whereas randomization to CRT and nonischemic cardiomyopathy decreased risk; multivariate predictors of pump failure death were baseline plasma BNP and systolic pressure and randomization to CRT. CONCLUSION: CRT decreased SCD in patients with systolic HF and ventricular dyssynchrony. SCD risk was increased with increased severity of MR (including the 3-month value for MR as a time-dependent covariate) and reduced by randomization to CRT. HF death was increased related to the level of systolic blood pressure, log BNP, and randomization to CRT. These results emphasize the importance and interdependence of HF severity to mortality from pump failure and SCD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real time glycemia is a cornerstone for metabolic research, particularly when performing oral glucose tolerance tests (OGTT) or glucose clamps. From 1965 to 2009, the gold standard device for real time plasma glucose assessment was the Beckman glucose analyzer 2 (Beckman Instruments, Fullerton, CA), which technology couples glucose oxidase enzymatic assay with oxygen sensors. Since its discontinuation in 2009, today's researchers are left with few choices that utilize glucose oxidase technology. The first one is the YSI 2300 (Yellow Springs Instruments Corp., Yellow Springs, OH), known to be as accurate as the Beckman(1). The YSI has been used extensively for clinical research studies and is used to validate other glucose monitoring devices(2). The major drawback of the YSI is that it is relatively slow and requires high maintenance. The Analox GM9 (Analox instruments, London), more recent and faster, is increasingly used in clinical research(3) as well as in basic sciences(4) (e.g. 23 papers in Diabetes or 21 in Diabetologia). This article is protected by copyright. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New products available for food creations include a wide variety of "supposed" food grade aerosol sprays. However, the gas propellants used cannot be considered as safe. The different legislations available did not rule any maximum residue limits, even though these compounds have some limits when used for other food purposes. This study shows a preliminary monitoring of propane, butane and dimethyl ether residues, in cakes and chocolate after spraying, when these gases are used as propellants in food aerosol sprays. Release kinetics of propane, butane and dimethyl ether were measured over one day with sprayed food, left at room temperature or in the fridge after spraying. The alkanes and dimethyl ether analyses were performed by headspace-gas chromatography-mass spectrometry/thermal conductivity detection, using monodeuterated propane and butane generated in situ as internal standards. According to the obtained results and regardingthe extrapolations of the maximum residue limits existing for these substances, different delays should be respected according to the storage conditions and the gas propellant to consume safely the sprayed food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.