206 resultados para total internal reflection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Population aging leads to a considerable increase in the prevalence of specific diseases. We aimed to assess if those changes were already reflected in an Internal Medicine ward. Methods : Anonymous data was obtained from the administrative database of the department of internal medicine of the Lausanne University Hospital (CHUV). All hospitalizations of adult (>=18 years) patients occurring between 2003 and 2011 were included. Infections, cancers and diseases according to body system (heart, lung...) were defined by the first letter of the ICD-10 code for the main cause of hospitalization. Specific diseases (myocardial infarction, heart failure...) were defined by the first three letters of the ICD-10 codes for the main cause of hospitalization. Results : Data from 32,741 hospitalizations occurring between 2003 and 2011 was analyzed. Cardiovascular (ICD-10 code I) and respiratory (ICD-10 code J) diseases ranked first and second, respectively, and their ranks did not change during the study period (figure). Digestive and endocrine diseases decreased while psychiatric diseases increased from rank 9 in 2003 to rank 6 in 2011 (figure). Among specific diseases, pneumonia (organism unspecified, code J18) ranked first in 2003 and second in 2011. Acute myocardial infarction (code I21) ranked second in 2003 and third in 2011. Chronic obstructive pulmonary disease with acute lower respiratory infection (code J44) ranked third in 2003 and decreased to rank 8 in 2011. Conversely, heart failure (code I50) increased from rank 8 in 2003 to rank 1 in 2011 and delirium (not induced by alcohol and other psychoactive substances, code F05) increased from below rank 20 in 2003 to rank 4 in 2011. For more details, see table. Conclusion : In less than 10 years, considerable changes occurred in the presentation of patients attending an Internal Medicine ward. The changes in diseases call for adaptations in hospital staff and logistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctors must regularly adjust their patients' care according to recent relevant publications. The chief residents from the Department of Internal Medicine of a university hospital present some major themes of internal medicine treated during the year 2008, such as heart failure, diabetes, COPD, and thromboembolic disease. Emphasis will be placed primarily on changes in the daily hospital practice induced by these recent studies. This variety of topics illustrates both the broad spectrum of the current internal medicine, and the many uncertainties associated with modem medical practice based on evidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Post-prescription review of hospital antibiotic therapy may contribute to more appropriate use. We estimated the impact of a standardised review of intravenous antibiotic therapy three days after prescription in two internal medicine wards of a university hospital. In one ward, we assessed the charts of patients under intravenous antibiotic therapy using a standardised review process and provided feedback to the prescriber. There was no intervention in the other ward. After six months we crossed the allocation between the two wards. In all, 204 courses of antibiotic therapy were included in the intervention periods and 226 in the control periods. Post-prescription review led to proposals for modification in 46% of antibiotic courses. Time to treatment modification was 22% shorter in the intervention periods compared with the control periods (3.9+/-5.2 days vs 5.0+/-6.0 days, P=0.007). Patients included in the intervention group had lower antibiotic consumption than patients in the control group, but the intervention had no significant impact on the overall antibiotic consumption of the two wards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections after total joint arthroplasty are rare but come with severe consequences. Timely, adequate and standardized treatment beginning at the onset of symptoms will have a major impact on the handling of this dreaded complication. In absences of clear guidelines, errors are often committed, with occasionally severe consequences for the patient. In this article, the 10 most frequent errors starting with diagnostics till antibiotic and surgical treatment will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: All kinds of blood manipulations aim to increase the total hemoglobin mass (tHb-mass). To establish tHb-mass as an effective screening parameter for detecting blood doping, the knowledge of its normal variation over time is necessary. The aim of the present study, therefore, was to determine the intraindividual variance of tHb-mass in elite athletes during a training year emphasizing off, training, and race seasons at sea level. METHODS: tHb-mass and hemoglobin concentration ([Hb]) were determined in 24 endurance athletes five times during a year and were compared with a control group (n = 6). An analysis of covariance was used to test the effects of training phases, age, gender, competition level, body mass, and training volume. Three error models, based on 1) a total percentage error of measurement, 2) the combination of a typical percentage error (TE) of analytical origin with an absolute SD of biological origin, and 3) between-subject and within-subject variance components as obtained by an analysis of variance, were tested. RESULTS: In addition to the expected influence of performance status, the main results were that the effects of training volume (P = 0.20) and training phases (P = 0.81) on tHb-mass were not significant. We found that within-subject variations mainly have an analytical origin (TE approximately 1.4%) and a very small SD (7.5 g) of biological origin. CONCLUSION: tHb-mass shows very low individual oscillations during a training year (<6%), and these oscillations are below the expected changes in tHb-mass due to Herythropoetin (EPO) application or blood infusion (approximately 10%). The high stability of tHb-mass over a period of 1 year suggests that it should be included in an athlete's biological passport and analyzed by recently developed probabilistic inference techniques that define subject-based reference ranges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some years ago, a parish in Geneva decided to reduce heating costs by insulating its church to make it more energy efficient. Three years after the last renovations, it was observed that the internal surfaces of the naves had already become dusty compared with the customary frequency of 10-12 years. Dust even deposited on various surfaces during religious services. Our investigation showed that nearly all the dust found inside the church may in fact be soot from incense and candle combustion. Incense appears to be a significant source of polycyclic aromatic hydrocarbons. With a mechanical ventilation system and petrol lamps resembling candles the problem can be resolved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the past decade, significant interest has been expressed in relating the spatial statistics of surface-based reflection ground-penetrating radar (GPR) data to those of the imaged subsurface volume. A primary motivation for this work is that changes in the radar wave velocity, which largely control the character of the observed data, are expected to be related to corresponding changes in subsurface water content. Although previous work has indeed indicated that the spatial statistics of GPR images are linked to those of the water content distribution of the probed region, a viable method for quantitatively analyzing the GPR data and solving the corresponding inverse problem has not yet been presented. Here we address this issue by first deriving a relationship between the 2-D autocorrelation of a water content distribution and that of the corresponding GPR reflection image. We then show how a Bayesian inversion strategy based on Markov chain Monte Carlo sampling can be used to estimate the posterior distribution of subsurface correlation model parameters that are consistent with the GPR data. Our results indicate that if the underlying assumptions are valid and we possess adequate prior knowledge regarding the water content distribution, in particular its vertical variability, this methodology allows not only for the reliable recovery of lateral correlation model parameters but also for estimates of parameter uncertainties. In the case where prior knowledge regarding the vertical variability of water content is not available, the results show that the methodology still reliably recovers the aspect ratio of the heterogeneity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.