258 resultados para test device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare species have restricted geographic ranges, habitat specialization, and/or small population sizes. Datasets on rare species distribution usually have few observations, limited spatial accuracy and lack of valid absences; conversely they provide comprehensive views of species distributions allowing to realistically capture most of their realized environmental niche. Rare species are the most in need of predictive distribution modelling but also the most difficult to model. We refer to this contrast as the "rare species modelling paradox" and propose as a solution developing modelling approaches that deal with a sufficiently large set of predictors, ensuring that statistical models aren't overfitted. Our novel approach fulfils this condition by fitting a large number of bivariate models and averaging them with a weighted ensemble approach. We further propose that this ensemble forecasting is conducted within a hierarchic multi-scale framework. We present two ensemble models for a test species, one at regional and one at local scale, each based on the combination of 630 models. In both cases, we obtained excellent spatial projections, unusual when modelling rare species. Model results highlight, from a statistically sound approach, the effects of multiple drivers in a same modelling framework and at two distinct scales. From this added information, regional models can support accurate forecasts of range dynamics under climate change scenarios, whereas local models allow the assessment of isolated or synergistic impacts of changes in multiple predictors. This novel framework provides a baseline for adaptive conservation, management and monitoring of rare species at distinct spatial and temporal scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Vertebral fracture is one of the major osteoporoticfractures which are unfortunately very often undetected. In addition,it is well known that prevalent vertebral fracture increases dramaticallythe risk of future additional fracture. Instant Vertebral Assessment(IVA) has been introduced in DXA device a couple of years ago toease the detection of such fracture when routine DXA are performed.To correctly use such tool, ISCD provided clinical recommendationon when and how to use it. The aim of our study was to evaluate theISCD guidelines in clinical routine patients and see how often itmay change of patient management.Methods During two months (March and April 2010), a medicalquestionnaire was systematically given to our clinical routine patientto check the validity of ISCD IVA recommendations in our population.In addition, all women had BMD measurement at AP spine,femur and 1/3 radius using a Discovery A System (Hologic, Waltham,USA). When appropriate, IVA measurement had been performedon the same DXA system and had been centrally evaluated by twotrained doctors for fracture status according to the semi-quantitativemethod of Genant. The reading had been performed when possiblebetween L5 and T4.Results Out of 210 women seen in the consultation, 109 (52 %)of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteriato have an IVA measurement. Out of these 109 women, 43 (incidence39.4 %) had osteoporosis at one of the three skeletal sitesand 31 (incidence 28.4 %) had at least one vertebral fracture. 14.7 %of women had both osteoporosis and at least one vertebral fractureclassifying them as "severe osteoporosis" while 46.8 % did not haveosteoporosis and no vertebral fracture. 24.8 % of the women hadosteoporosis but no vertebral fracture while 13.8 % of women didhave osteoporosis but vertebral fracture (clinical osteoporosis).Conclusions In 52 % of our patients, IVA was needed accordingto ISCD criteria. In half of them the IVA test influenced of patientmanagement either may changing the type of treatment of simplyby classifying patient as "clinical osteoporosis". IVA appears to bean important tool in clinical routine but unfortunately is not yetvery often use in most of the centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives  This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods  Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results  The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion  The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review paper reports the consensus of a technical workshop hosted by the European network, NanoImpactNet (NIN). The workshop aimed to review the collective experience of working at the bench with manufactured nanomaterials (MNMs), and to recommend modifications to existing experimental methods and OECD protocols. Current procedures for cleaning glassware are appropriate for most MNMs, although interference with electrodes may occur. Maintaining exposure is more difficult with MNMs compared to conventional chemicals. A metal salt control is recommended for experiments with metallic MNMs that may release free metal ions. Dispersing agents should be avoided, but if they must be used, then natural or synthetic dispersing agents are possible, and dispersion controls essential. Time constraints and technology gaps indicate that full characterisation of test media during ecotoxicity tests is currently not practical. Details of electron microscopy, dark-field microscopy, a range of spectroscopic methods (EDX, XRD, XANES, EXAFS), light scattering techniques (DLS, SLS) and chromatography are discussed. The development of user-friendly software to predict particle behaviour in test media according to DLVO theory is in progress, and simple optical methods are available to estimate the settling behaviour of suspensions during experiments. However, for soil matrices such simple approaches may not be applicable. Alternatively, a Critical Body Residue approach may be taken in which body concentrations in organisms are related to effects, and toxicity thresholds derived. For microbial assays, the cell wall is a formidable barrier to MNMs and end points that rely on the test substance penetrating the cell may be insensitive. Instead assays based on the cell envelope should be developed for MNMs. In algal growth tests, the abiotic factors that promote particle aggregation in the media (e.g. ionic strength) are also important in providing nutrients, and manipulation of the media to control the dispersion may also inhibit growth. Controls to quantify shading effects, and precise details of lighting regimes, shaking or mixing should be reported in algal tests. Photosynthesis may be more sensitive than traditional growth end points for algae and plants. Tests with invertebrates should consider non-chemical toxicity from particle adherence to the organisms. The use of semi-static exposure methods with fish can reduce the logistical issues of waste water disposal and facilitate aspects of animal husbandry relevant to MMNs. There are concerns that the existing bioaccumulation tests are conceptually flawed for MNMs and that new test(s) are required. In vitro testing strategies, as exemplified by genotoxicity assays, can be modified for MNMs, but the risk of false negatives in some assays is highlighted. In conclusion, most protocols will require some modifications and recommendations are made to aid the researcher at the bench. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Port-a-Cath© (PAC) are totally implantable devices that offer an easy and long term access to venous circulation. They have been extensively used for intravenous therapy administration and are particularly well suited for chemotherapy in oncologic patients. Previous comparative studies have shown that these devices have the lowest catheter-related bloodstream infection rates among all intravascular access systems. However, bloodstream infection (BSI) still remains a major issue of port use and epidemiology data for PAC-associated BSI (PABSI) rates differ strongly depending on studies. Also, current literature about PABSI risk factors is scarce and sometimes controversial. Such heterogeneity may depend on type of studied population and local factors. Therefore, the aim of this study was to describe local epidemiology and risk factors for PABSI in adult patients in our tertiary- care university hospital. We conducted a retrospective cohort study in order to describe local epidemiology. We also performed a nested case-control study to identify local risk factors of PABSI. We analyzed medical files of adult patients who had a PAC implanted between January 1st, 2008 and December 31st, 2009 and looked for PABSI occurrence before May 1st, 2011 to define cases. Thirty nine PABSI occurred in this population with an attack rate of 5.8%. We estimated an incidence rate of 0.08/1000 PAC-days using the case-control study. PABSI causative agents were mainly Gram positive cocci (62%). We identified three predictive factors of PABSI by multivariate statistical analysis: neutropenia on outcome date (Odds Ratio [OR]: 4.05; 95% confidence interval [CI]:1.05- 15.66; p=0.042), diabetes (OR: 11.53; 95% CI: 1.07-124.70; p=0.044) and having another infection than PABSI on outcome date (OR: 6.35; 95% CI: 1.50-26.86; p=0.012). Patients suffering from acute or renal failure (OR: 4.26; 95% CI: 0.94-19.21; p=0.059) or wearing another invasive device (OR: 2.99; 95%CI:0.96-9.31; p=0.059) did not have a statistically increased risk for developing a PABSI according to classical threshold (p<0.05) but nevertheless remained close to significance. Our study demonstrated that local epidemiology and microbiology of PABSI in our institution was similar to previous reports. A larger prospective study is required to confirm our results or to test preventive measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the efficacy of teaching motivational interviewing (MI) to medical students. Methods: Thirteen 4th year medical students volunteered to participate. Seven days before and 7 days after an 8-hour interactive training MI workshop, each student performed a videorecorded interview with two standardized patients: a 60 year old alcohol dependent woman and a 50 year old cigarette smoking man. Students' counseling skills were coded by two blinded clinicians using the Motivational Interviewing Treatment Integrity 3.0 (MITI). Inter-rater reliability was calculated for all interviews and a test-retest was completed in a sub-sample of 10 consecutive interviews three days apart. Difference between MITI scores before and after training were calculated and tested using non-parametric tests. Effect size was approximated by calculating the probability that posttest scores are greater than pretest scores (P*=P(Pre<Post)+1/2P(Pre=Post)), P*>1/2 indicating greater scores in posttest, P*=1/2 no effect, and P*<1/2 smaller scores in posttest. Results: Median differences between MITI scores before and after MI training indicated a general progression in MI skills: MI spirit global score (median difference=1.5, Inter quartile range=1.5, p<0.001, P*=0.90); Empathy global score (med diff=1, IQR=0.5, p<0.001, P*=0.85); Percentage of MI adherent skills (med diff=36.6, IQR=50.5, p<0.001, P*=0.85); Percentage of open questions (med diff=18.6, IQR=21.6, p<0.001, P*=0.96); reflections/ questions ratio (med diff=0.2, IQR=0.4, p<0.001, P*=0.81). Only Direction global score and the percentage of complex reflections were not significantly improved (med diff=0, IQR=1, p=0.53, P*=0.44, and med diff=4.3, IQR=24.8, p=0.48, P*=0.62, respectively). Inter-rater reliability indicated weighted kappa ranged between 0.14 for Direction to 0.51 for Collaboration and ICC ranged between 0.28 for Simple reflection to 0.95 for Closed question. Test-retests indicated weighted kappa ranged between 0.27 for Direction to 0.80 for Empathy and ICC ranged between 0.87 for Complex reflection to 0.98 for Closed question. Conclusion: This pilot study indicated that an 8-hour training in MI for voluntary 4th year medical students resulted in significant improvement of MI skills. Larger sample of unselected medical students should be studied to generalize the benefit of MI training to medical students. Interrater reliability and test-retests suggested that coders' training should be intensified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Swain corrects the chi-square overidentification test (i.e., likelihood ratio test of fit) for structural equation models whethr with or without latent variables. The chi-square statistic is asymptotically correct; however, it does not behave as expected in small samples and/or when the model is complex (cf. Herzog, Boomsma, & Reinecke, 2007). Thus, particularly in situations where the ratio of sample size (n) to the number of parameters estimated (p) is relatively small (i.e., the p to n ratio is large), the chi-square test will tend to overreject correctly specified models. To obtain a closer approximation to the distribution of the chi-square statistic, Swain (1975) developed a correction; this scaling factor, which converges to 1 asymptotically, is multiplied with the chi-square statistic. The correction better approximates the chi-square distribution resulting in more appropriate Type 1 reject error rates (see Herzog & Boomsma, 2009; Herzog, et al., 2007).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. This study is an evaluation of the vacuum-assisted closure (VAC) therapy for the treatment of severe intrathoracic infections complicating lung resection, esophageal surgery, viscera perforation, or necrotizing pleuropulmonary infections.Methods. We reviewed the medical records of all patients treated by intrathoracic VAC therapy between January 2005 and December 2008. All patients underwent surgical debridement-decortication and control of the underlying cause of infection such as treatment of bronchus stump insufficiency, resection of necrotic lung, or closure of esophageal or intestinal leaks. Surgery was followed by intrathoracic VAC therapy until the infection was controlled. The VAC dressings were changed under general anesthesia and the chest wall was temporarily closed after each dressing change. All patients received systemic antibiotic therapy.Results. Twenty-seven patients (15 male, median age 64 years) underwent intrathoracic VAC dressings for the management of postresectional empyema (n = 8) with and without bronchopleural fistula, necrotizing infections (n = 7), and intrathoracic gastrointestinal leaks (n = 12). The median length of VAC therapy was 22 days (range 5 to 66) and the median number of VAC changes per patient was 6 (range 2 to 16). In-hospital mortality was 19% (n = 5) and was not related to VAC therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in all surviving patients.Conclusions. Vacuum-assisted closure therapy is an efficient and safe adjunct to treat severe intrathoracic infections and may be a good alternative to the open window thoracostomy in selected patients. Long time intervals in between VAC changes and short course of therapy result in good patient acceptance. (Ann Thorac Surg 2011;91:1582-90) (C) 2011 by The Society of Thoracic Surgeons