204 resultados para soft-commutation technique
Resumo:
BACKGROUND: Soft tissue sarcomas of the trunk wall (STS-TW) are usually studied together with soft tissue sarcomas of other locations. We report a study on STS-TW forming part of the French Sarcoma Group database. PATIENTS AND METHODS: Three hundred and forty-three adults were included. We carried out univariate and multivariate analysis for overall survival (OS), metastasis-free survival (MFS) and local recurrence-free survival (LRFS). RESULTS: Tumor locations were as follows: thoracic wall, 82.5%; abdominal wall, 12.3% and pelvic wall, 5.2%. Median tumor size was 6.0 cm. The most frequent tumor types were unclassified sarcoma (27.7%) and myogenic sarcoma (19.2%). A total of 44.6% of cases were grade 3. In all, 21.9% of patients had a previous medical history of radiotherapy (PHR). Median follow-up was 7.6 years. The 5-year OS, MFS and LRFS rates were 60.4%, 68.9% and 58.4%, respectively. Multivariate analysis retained PHR and grade for predicting LRFS and PHR, size and grade as prognostic factors of MFS. Factors influencing OS were age, size, PHR, depth, grade and surgical margins. The predictive factors of incomplete response were PHR, size and T3. CONCLUSIONS: Our results suggest similar classical prognostic factors as compared with sarcomas of other locations. However, a separate analysis of STS-TW revealed a significant poor prognosis subgroup of patients with PHR.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
L' évaluation quantitative des dangers et des expositions aux nanomatériaux se heurte à de nombreuses incertitudes qui ne seront levées qu'à mesure de la progression des connaissances scientifiques de leurs propriétés. L' une des conséquences de ces incertitudes est que les valeurs limites d'exposition professionnelle définies actuellement pour les poussières ne sont pas nécessairement pertinentes aux nanomatériaux. En l'absence de référentiel quantitatif et, à la demande de la DGS pour éclairer les réflexions de l' AFNOR et de l'ISO sur le sujet, une démarche de gestion graduée des risques (control banding) a été élaborée au sein de l' Anses. Ce développement a été réalisé à l'aide d'un groupe d'experts rapporteurs rattaché au Comité d'experts spécialisés évaluation des risques liés aux agents physiques, aux nouvelles technologies et aux grands aménagements. La mise en oeuvre de la démarche de gestion graduée des risques proposée repose sur quatre grandes étapes: 1. Le recueil des informations. Cette étape consiste à réunir les informations disponibles sur les dangers du nanomatériau manufacturé considéré ; ainsi que sur l'exposition potentielle des personnes aux postes de travail (observation sur le terrain, mesures, etc.). 2. L'attribution d'une bande de danger. Le danger potentiel du nanomatériau manufacturé présent, qu'il soit brut où incorporé dans une matrice (liquide ou solide) est évalué dans cette étape. La bande danger attribuée tient compte de la dangerosité du produit bulk ou de sa substance analogue à l'échelle non-nanométrique, de la bio-persistance du matériau (pour les matériaux fibreux), de sa solubilité et de son éventuelle réactivité. 3. Attribution d'une bande d'exposition. La bande d'exposition du nanomatériau manufacturé considéré ou du produit en contenant est définie par le niveau de potentiel d'émission du produit. Elle tient compte de sa forme physique (solide, liquide, poudre aérosol), de sa pulvérulence et de sa volatilité. Le nombre de travailleurs, la fréquence, la durée d'exposition ainsi que la quantité mise en oeuvre ne sont pas pris en compte, contrairement à une évaluation classique des risques chimiques. 4. Obtention d'une bande de maîtrise des risques. Le croisement des bandes de dangers et d'exposition préalablement attribuées permet de défi nir le niveau de maîtrise du risque. Il fait correspondre les moyens techniques et organisationnels à mettre en oeuvre pour maintenir le risque au niveau le plus faible possible. Un plan d'action est ensuite défi ni pour garantir l'effi cacité de la prévention recommandée par le niveau de maîtrise déterminé. Il tient compte des mesures de prévention déjà existantes et les renforce si nécessaire. Si les mesures indiquées par le niveau de maîtrise de risque ne sont pas réalisables, par exemple, pour des raisons techniques ou budgétaires, une évaluation de risque approfondie devra être réalisée par un expert. La gestion graduée des risques est une méthode alternative pour réaliser une évaluation qualitative de risques et mettre en place des moyens de prévention sans recourir à une évaluation quantitative des risques. Son utilisation semble particulièrement adaptée au contexte des nanomatériaux manufacturés, pour lequel les choix de valeurs de référence (Valeurs limites d'exposition en milieu professionnel) et des techniques de mesurage appropriées souffrent d'une grande incertitude. La démarche proposée repose sur des critères simples, accessibles dans la littérature scientifi que ou via les données techniques relatives aux produits utilisés. Pour autant, sa mise en oeuvre requiert des compétences minimales dans les domaines de la prévention des risques chimiques (chimie, toxicologie, etc.), des nanosciences et des nanotechnologies.
Resumo:
Cerebral blood flow can be studied in a multislice mode with a recently proposed perfusion sequence using inversion of water spins as an endogenous tracer without magnetization transfer artifacts. The magnetization transfer insensitive labeling technique (TILT) has been used for mapping blood flow changes at a microvascular level under motor activation in a multislice mode. In TILT, perfusion mapping is achieved by subtraction of a perfusion-sensitized image from a control image. Perfusion weighting is accomplished by proximal blood labeling using two 90 degrees radiofrequency excitation pulses. For control preparation the labeling pulses are modified such that they have no net effect on blood water magnetization. The percentage of blood flow change, as well as its spatial extent, has been studied in single and multislice modes with varying delays between labeling and imaging. The average perfusion signal change due to activation was 36.9 +/- 9.1% in the single-slice experiments and 38.1 +/- 7.9% in the multislice experiments. The volume of activated brain areas amounted to 1.51 +/- 0.95 cm3 in the contralateral primary motor (M1) area, 0.90 +/- 0.72 cc in the ipsilateral M1 area, 1.27 +/- 0.39 cm3 in the contralateral and 1.42 +/- 0.75 cm3 in the ipsilateral premotor areas, and 0.71 +/- 0.19 cm3 in the supplementary motor area.
Resumo:
Knowledge of the reflectivity of the sediment-covered seabed is of significant importance to marine seismic data acquisition and interpretation as it governs the generation of reverberations in the water layer. In this context pertinent, but largely unresolved, questions concern the importance of the typically very prominent vertical seismic velocity gradients as well as the potential presence and magnitude of anisotropy in soft surficial seabed sediments. To address these issues, we explore the seismic properties of granulometric end-member-type clastic sedimentary seabed models consisting of sand, silt, and clay as well as scale-invariant stochastic layer sequences of these components characterized by realistic vertical gradients of the P- and S-wave velocities. Using effective media theory, we then assess the nature and magnitude of seismic anisotropy associated with these models. Our results indicate that anisotropy is rather benign for P-waves, and that the S-wave velocities in the axial directions differ only slightly. Because of the very high P- to S-wave velocity ratios in the vicinity of the seabed our models nevertheless suggest that S-wave triplications may occur at very small incidence angles. To numerically evaluate the P-wave reflection coefficient of our seabed models, we apply a frequency-slowness technique to the corresponding synthetic seismic wavefields. Comparison with analytical plane-wave reflection coefficients calculated for corresponding isotropic elastic half-space models shows that the differences tend to be most pronounced in the vicinity of the elastic equivalent of the critical angle as well as in the post-critical range. We also find that the presence of intrinsic anisotropy in the clay component of our layered models tends to dramatically reduce the overall magnitude of the P-wave reflection coefficient as well as its variation with incidence angle.
Resumo:
Background: Arthrodesis of the knee by intramedullary fixation hasbeen reported to have a higher rate of success than external fixationor compression plating. Antegrade nailing however can lead to complicationsdue to the different diameters of the medullary canals, fracturesduring insertion, poor rotational stability, breakage of the IM-nailand insufficient compression at the fusion site.Method: This retrospective study reports all knee fusions performedby the same orthopaedic surgeon with the Wichita (Stryker) fusion nail(WFN) from 2004 to 2010. The Wichita nail is a short nail with a deviceat the knee which allows for coupling of differently sized and interlockedfemoral and tibial components and at the same time for compression.Results: We report of 18 patients with a mean follow up of 28 months(range 3-71 months). Infected TKA was the most common indicationfor arthrodesis in 9 cases. The remaining reasons included asepticfailed TKA in 3 cases, 2 patients after fracture, 1 patient with neurologicalinstability after knee dislocation, 1 patient after tumoral resectionand 1 non union after failed arthrodesis with long antegrade nail.Finally 1 patient with bilateral congenital knee dislocation operated onboth sides. As expected, patients receiving the WFN had undergonea large number of previous knee surgeries with a mean of 3.8 (range0-8) procedures per patient. The complication rate was 27% (5 of 18).Two patients had persistent pain requiring revision surgery to increasestability with plating. One case of periprosthetic fracture needed openreduction and internal fixation. 2 patients with superficial hematomawere treated one with open drainage and the other with physiotherapy.Infection was erradicated in all septic cases, we found no new infectionand the fusion rate was 100%.Conclusion: The results in these often difficult cases are satisfyingand we think that this technique is a valid alternative to the otherknown techniques of knee fusion in patients with a poor bone stockand fragile soft tissues.
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Resumo:
OBJECTIVES: To evaluate the results of retrograde percutaneous screw fixation (PSF) in minimally or undisplaced acetabular fractures in a geriatric population. PATIENTS AND METHODS: Between July 1998 and July 2001, 21 consecutive patients with an acetabular fracture underwent fluoroscopic guided percutaneous fixation. The mean age was 81 years (range 67--90 years). In all cases, the fracture was minimally or undisplaced (<2mm). Two cannulated cancellous 7.3mm screws were inserted in a retrograde fashion to stabilise the posterior and the anterior column. Bed to chair transfer began after 24h. Weight bearing as tolerated was allowed at 4 weeks. RESULTS: Eighteen patients were reviewed at a mean of 3.5 years (range 2--5 years). Soft tissue dissection was minimal. There were no intraoperative or postoperative complications. At the latest follow-up there was no radiographical evidence of secondary displacement of fragments, degenerative changes, or screw failure. Fractures healed at a mean time of 12 weeks (range 8--15 weeks). Clinical results were satisfactory in 17 patients. CONCLUSION: Our results show that percutaneous screw fixation under fluoroscopic control is a safe technique to treat some pattern of acetabular fracture.
Resumo:
Soft tissue sarcomas (STS) with complex genomic profiles (50% of all STS) are predominantly composed of spindle cell/pleomorphic sarcomas, including leiomyosarcoma, myxofibrosarcoma, pleomorphic liposarcoma, pleomorphic rhabdomyosarcoma, malignant peripheral nerve sheath tumor, angiosarcoma, extraskeletal osteosarcoma, and spindle cell/pleomorphic unclassified sarcoma (previously called spindle cell/pleomorphic malignant fibrous histiocytoma). These neoplasms show, characteristically, gains and losses of numerous chromosomes or chromosome regions, as well as amplifications. Many of them share recurrent aberrations (e.g., gain of 5p13-p15) that seem to play a significant role in tumor progression and/or metastatic dissemination. In this paper, we review the cytogenetic, molecular genetic, and clinicopathologic characteristics of the most common STS displaying complex genomic profiles. Features of diagnostic or prognostic relevance will be discussed when needed.