149 resultados para reverse wave suppression
Resumo:
Introduction: Several methods have already been proposed to improve the mobility of reversed prostheses (lateral or inferior displacement, increase of the glenosphere size). However, the effect of these design changes have only been evaluated on the maximal range of motion and were not related to activities of daily living (ADL). Our aim was thus to measure the effect of these design changes and to relate it to 4 typical ADL. Methods: CT data were used to reconstruct a accurate geometric model of the scapula and humerus. The Aequalis reversed prosthesis (Tornier) was used. The mobility of a healthy shoulder was compared to the mobility of 4 different reversed designs: 36 and 42 mm glenospheres diameters, inferior (4 mm) and lateral (3.2 mm) glenospheres displacements. The complete mobility map of the prosthesis was compared to kinematics measurement on healthy subjects for 4 ADL: 1) hand to contra lateral shoulder, 2) hand to mouth, 3) combing hair, 4) hand to back pocket. The results are presented as percentage of the allowed movement of the prosthestic shouder relative to the healthy shoulder, considered as the control group. Results: None of the tested designs allowed to recover a full mobility. The differences of allowed range of motion among each prosthetic designs appeared mainly in two of the 4 movements: hand to back pocket and hand to contra lateral shoulder. For the hand to back pocket, the 36 had the lowest mobility range, particularly for the last third of the movement. The 42 appeared to be a good compromise for all ADL activities. Conclusion: Reverse shoulder prostheses does not allow to recover a full range of motion compared to healthy shoulders, even for ADL. The present study allowed to obtain a complete 3D mobility map for several glenosphere positions and sizes, and to relate it to typical ADL. We mainly observed an improved mobility with inferior displacement and increased glenosphere size. We would suggest to use larger glenosphere, whenever it is possible.
Resumo:
The current state of empirical investigations refers to consciousness as an all-or-none phenomenon. However, a recent theoretical account opens up this perspective by proposing a partial level (between nil and full) of conscious perception. In the well-studied case of single-word reading, short-lived exposure can trigger incomplete word-form recognition wherein letters fall short of forming a whole word in one's conscious perception thereby hindering word-meaning access and report. Hence, the processing from incomplete to complete word-form recognition straightforwardly mirrors a transition from partial to full-blown consciousness. We therefore hypothesized that this putative functional bottleneck to consciousness (i.e. the perceptual boundary between partial and full conscious perception) would emerge at a major key hub region for word-form recognition during reading, namely the left occipito-temporal junction. We applied a real-time staircase procedure and titrated subjective reports at the threshold between partial (letters) and full (whole word) conscious perception. This experimental approach allowed us to collect trials with identical physical stimulation, yet reflecting distinct perceptual experience levels. Oscillatory brain activity was monitored with magnetoencephalography and revealed that the transition from partial-to-full word-form perception was accompanied by alpha-band (7-11 Hz) power suppression in the posterior left occipito-temporal cortex. This modulation of rhythmic activity extended anteriorly towards the visual word form area (VWFA), a region whose selectivity for word-forms in perception is highly debated. The current findings provide electrophysiological evidence for a functional bottleneck to consciousness thereby empirically instantiating a recently proposed partial perspective on consciousness. Moreover, the findings provide an entirely new outlook on the functioning of the VWFA as a late bottleneck to full-blown conscious word-form perception.
Resumo:
Wave-induced fluid flow at microscopic and mesoscopic scales arguably constitutes the major cause of intrinsic seismic attenuation throughout the exploration seismic and sonic frequency ranges. The quantitative analysis of these phenomena is, however, complicated by the fact that the governing physical processes may be dependent. The reason for this is that the presence of microscopic heterogeneities, such as micro-cracks or broken grain contacts, causes the stiffness of the so-called modified dry frame to be complex-valued and frequency-dependent, which in turn may affect the viscoelastic behaviour in response to fluid flow at mesoscopic scales. In this work, we propose a simple but effective procedure to estimate the seismic attenuation and velocity dispersion behaviour associated with wave-induced fluid flow due to both microscopic and mesoscopic heterogeneities and discuss the results obtained for a range of pertinent scenarios.
Resumo:
Intestinal microfold (M) cells possess a high transcytosis capacity and are able to transport a broad range of materials including particulate antigens, soluble macromolecules, and pathogens from the intestinal lumen to inductive sites of the mucosal immune system. M cells are also the primary pathway for delivery of secretory IgA (SIgA) to the gut-associated lymphoid tissue. However, although the consequences of SIgA uptake by M cells are now well known and described, the mechanisms whereby SIgA is selectively bound and taken up remain poorly understood. Here we first demonstrate that both the Cα1 region and glycosylation, more particularly sialic acid residues, are involved in M cell-mediated reverse transcytosis. Second, we found that SIgA is taken up by M cells via the Dectin-1 receptor, with the possible involvement of Siglec-5 acting as a co-receptor. Third, we establish that transcytosed SIgA is taken up by mucosal CX3CR1⁺ dendritic cells (DCs) via the DC-SIGN receptor. Fourth, we show that mucosal and systemic antibody responses against the HIV p24-SIgA complexes administered orally is strictly dependent on the expression of Dectin-1. Having deciphered the mechanisms leading to specific targeting of SIgA-based Ag complexes paves the way to the use of such a vehicle for mucosal vaccination against various infectious diseases.
Resumo:
La rigidité anormalement haute des artères à grande conductance est un marqueur de l'augmentation du risque cardiovasculaire et est typiquement retrouvée chez les patients diabétiques ou hypertendus. Ces vaisseaux deviennent plus rigides avec l'âge, expliquant la haute prévalence d'hypertension systolique chez les personnes âgées. Cette rigidification agit sur la pression sanguine de plusieurs façons. Notamment la fonction windkessel est gênée, menant à l'augmentation de la pression systolique et de la pression puisée, la diminution de la pression diastolique, et ainsi à l'augmentation de la postcharge ventriculaire gauche associée à une probable diminution de la perfusion coronarienne. De plus, la propagation des ondes de pression le long de l'arbre vasculaire est accélérée, de sorte que les ondes réfléchies générées au site de décalage d'impédance atteignent l'aorte ascendante plus tôt par rapport au début de l'éjection ventriculaire, aboutissant à une augmentation de la pression systolique centrale, ce qui n'arriverait pas en présence de vaisseaux moins rigides. Dans ce cas, au contraire, les ondes de pression antérogrades et réfléchies voyages plus lentement, de sorte que les ondes de réflexion tendent à atteindre l'aorte centrale une fois l'éjection terminée, augmentant la pression diastolique et contribuant à la perfusion coronarienne. La tonométrie d'applanation est une méthode non invasive permettant l'évaluation de la forme de l'onde de pression au niveau l'aorte ascendante, basée sur l'enregistrement du pouls périphérique, au niveau radial dans notre étude. Nous pouvons dériver à partir de cette méthode un index d'augmentation systolique (sAIX) qui révèle quel pourcentage de la pression centrale est du aux ondes réfléchies. Plusieurs études ont montré que cet index est corrélé à d'autres mesures de la rigidité artérielle comme la vitesse de l'onde de pouls, qu'il augmente avec l'âge et avec les facteurs de risques cardiovasculaires, et qu'il est capable de préciser le pronostic cardiovasculaire. En revanche, peu d'attention a été portée à l'augmentation de la pression centrale diastolique due aux ondes réfléchies (dAIX). Nous proposons donc de mesurer cet index par un procédé d'analyse développé dans notre laboratoire, et ce dans la même unité que l'index systolique. Etant donné que les modifications de la paroi artérielle modulent d'une part la vitesse de l'onde de pouls (PWV) et d'autre part le temps de voyage aller-retour des ondes de pression réfléchies aux sites de réflexion, toute augmentation de la quantité d'énergie réfléchie atteignant l'aorte pendant la systole devrait être associée à une diminution de l'énergie arrivant au même point pendant la diastole. Notre étude propose de mesurer ces deux index, ainsi que d'étudier la relation de l'index d'augmentation diastolique (dAIX) avec la vitesse de propagation de l'onde de pouls (PWV) et avec le rythme cardiaque (HR), ce dernier étant connu pour influencer l'index d'augmentation systolique (sAIX) . L'influence de la position couchée et assise est aussi étudiée. Les mesures de la PWV et des sAIX et dAIX est réalisée chez 48 hommes et 45 femmes âgées de 18 à 70 ans, classés en 3 groupes d'âges. Les résultats montrent qu'en fonction de l'âge, le genre et la position du corps, il y a une relation inverse entre sAIX et dAIX. Lorsque PWV et HR sont ajoutés comme covariables à un modèle de prédiction comprenant l'âge, le genre et la position du corps comme facteurs principaux, sAIX est directement lié à PWV (p<0.0001) et inversement lié à HR (p<0.0001). Avec la même analyse, dAIX est inversement lié à PWV (p<0.0001) et indépendant du rythme cardiaque (p=0.52). En conclusion, l'index d'augmentation diastolique est lié à la rigidité vasculaire au même degré que l'index d'augmentation systolique, alors qu'il est affranchi de l'effet confondant du rythme cardiaque. La quantification de l'augmentation de la pression aortique diastolique due aux ondes réfléchies pourrait être une partie utile de l'analyse de l'onde de pouls.
Resumo:
AIM: Phylogenetic diversity patterns are increasingly being used to better understand the role of ecological and evolutionary processes in community assembly. Here, we quantify how these patterns are influenced by scale choices in terms of spatial and environmental extent and organismic scales. LOCATION: European Alps. METHODS: We applied 42 sampling strategies differing in their combination of focal scales. For each resulting sub-dataset, we estimated the phylogenetic diversity of the species pools, phylogenetic α-diversities of local communities, and statistics commonly used together with null models in order to infer non-random diversity patterns (i.e. phylogenetic clustering versus over-dispersion). Finally, we studied the effects of scale choices on these measures using regression analyses. RESULTS: Scale choices were decisive for revealing signals in diversity patterns. Notably, changes in focal scales sometimes reversed a pattern of over-dispersion into clustering. Organismic scale had a stronger effect than spatial and environmental extent. However, we did not find general rules for the direction of change from over-dispersion to clustering with changing scales. Importantly, these scale issues had only a weak influence when focusing on regional diversity patterns that change along abiotic gradients. MAIN CONCLUSIONS: Our results call for caution when combining phylogenetic data with distributional data to study how and why communities differ from random expectations of phylogenetic relatedness. These analyses seem to be robust when the focus is on relating community diversity patterns to variation in habitat conditions, such as abiotic gradients. However, if the focus is on identifying relevant assembly rules for local communities, the uncertainty arising from a certain scale choice can be immense. In the latter case, it becomes necessary to test whether emerging patterns are robust to alternative scale choices.
Resumo:
Rapport de synthèse Ce travail de thèse s'articule autour de l'importance de l'évaluation de la fonction vasculaire et des répercussions au niveau central, cardiaque, des perturbations du réseau vasculaire. Les maladies cardiovasculaires sont prédominantes dans notre société et causes de morbidité et mortalité importante. La mesure de la pression artérielle classique reste le moyen le plus utilisé pour suivre la santé des vaisseaux, mais ne reflète pas directement ce qui se passe au niveau du coeur. La tonométrie d'aplanation permet depuis quelques années de mesurer l'onde de pouls radial, et par le biais d'une fonction mathématique de transfert validée, il est possible d'en déduire la forme et Γ amplitude de l'onde de pouls central, donc de la pression aortique centrale. Cette dernière est un reflet bien plus direct de la post-charge cardiaque, et de nombreuses études cliniques actuelles s'intéressent à cette mesure pour stratifier le risque ou évaluer l'effet d'un traitement vasculaire. Toutefois, bien que cet outil soit de plus en plus utilisé, il est rarement précisé si la latéralité de la mesure joue un rôle, sachant que certaines propriétés des membres supérieurs peuvent être affectées par un usage préférentiel (masse musculaire, densité osseuse, diamètre des artères, capillarisation musculaire, et même fonction endothéliale). On a en effet observé que ces divers paramètre étaient tous augmentés sur un bras entraîné. Dès lors on peut se poser la question de l'influence de ces adaptations physiologiques sur la mesure indirecte effectuée par le biais du pouls radial. Nous avons investigué les deux membres supérieurs de sujets jeunes et sédentaires (SED), ainsi que ceux de sujets sportifs avec un développement fortement asymétrique des bras, soit des joueurs de tennis de haut niveau (TEN). Des mesures anthropométriques incluant la composition corporelle et la circonférence des bras et avant-bras ont montré que TEN présente une asymétrie hautement significative aux deux mesures entre le bras dominant (entraîné) et l'autre, ce qui est aussi présent pour la force de serrage (mesurée au dynamomètre de Jamar). L'analyse des courbes centrales de pouls ne montre aucune différence entre les deux membres dans chaque groupe, par contre on peut observer une différence entre SED et TEN, avec un index d'augmentation diastolique qui est 50 % plus élevé chez TEN. Les index d'augmentation systolique sont identiques dans les deux groupes. On peut retenir de cette étude la validité de la méthode de tonométrie d'aplanation quel que soit le bras utilisé (dominant ou non-dominant) et ce même si une asymétrie conséquente est présente. Ces données sont clairement nouvelles et permettent de s'affranchir de cette variable dans la mesure d'un paramètre cardiovasculaire dont l'importance est actuellement grandissante. Les différences d'index diastolique sont expliquées par la fréquence cardiaque et la vitesse de conduction de l'onde de pouls plus basses chez TEN, causant un retard diastolique du retour de l'onde au niveau central, phénomène précédemment bien décrit dans la littérature.
Resumo:
Purpose To investigate the differences in viscoelastic properties between normal and pathologic Achilles tendons ( AT Achilles tendon s) by using real-time shear-wave elastography ( SWE shear-wave elastography ). Materials and Methods The institutional review board approved this study, and written informed consent was obtained from 25 symptomatic patients and 80 volunteers. One hundred eighty ultrasonographic (US) and SWE shear-wave elastography studies of AT Achilles tendon s without tendonopathy and 30 studies of the middle portion of the AT Achilles tendon in patients with tendonopathy were assessed prospectively. Each study included data sets acquired at B-mode US (tendon morphology and cross-sectional area) and SWE shear-wave elastography (axial and sagittal mean velocity and relative anisotropic coefficient) for two passively mobilized ankle positions. The presence of AT Achilles tendon tears at B-mode US and signal-void areas at SWE shear-wave elastography were noted. Results Significantly lower mean velocity was shown in tendons with tendonopathy than in normal tendons in the relaxed position at axial SWE shear-wave elastography (P < .001) and in the stretched position at sagittal (P < .001) and axial (P = .0026) SWE shear-wave elastography . Tendon softening was a sign of tendonopathy in relaxed AT Achilles tendon s when the mean velocity was less than or equal to 4.06 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 54.2%; 95% confidence interval [ CI confidence interval ]: 32.8, 74.4; specificity, 91.5%; 95% CI confidence interval : 86.3, 95.1) and less than or equal to 5.70 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 41.7%; 95% CI confidence interval : 22.1, 63.3; specificity, 81.8%; 95% CI confidence interval : 75.3, 87.2) and in stretched AT Achilles tendon s, when the mean velocity was less than or equal to 4.86 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 66.7%; 95% CI confidence interval : 44.7, 84.3; specificity, 75.6%; 95% CI confidence interval : 68.5, 81.7) and less than or equal to 14.58 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 58.3%; 95% CI confidence interval : 36.7, 77.9; specificity, 83.5%; 95% CI confidence interval : 77.2, 88.7). Anisotropic results were not significantly different between normal and pathologic AT Achilles tendon s. Six of six (100%) partial-thickness tears appeared as signal-void areas at SWE shear-wave elastography . Conclusion Whether the AT Achilles tendon was relaxed or stretched, SWE shear-wave elastography helped to confirm and quantify pathologic tendon softening in patients with tendonopathy in the midportion of the AT Achilles tendon and did not reveal modifications of viscoelastic anisotropy in the tendon. Tendon softening assessed by using SWE shear-wave elastography appeared to be highly specific, but sensitivity was relatively low. © RSNA, 2014.
Resumo:
The genotyping of human papillomaviruses (HPV) is essential for the surveillance of HPV vaccines. We describe and validate a low-cost PGMY-based PCR assay (PGMY-CHUV) for the genotyping of 31 HPV by reverse blotting hybridization (RBH). Genotype-specific detection limits were 50 to 500 genome equivalents per reaction. RBH was 100% specific and 98.61% sensitive using DNA sequencing as the gold standard (n = 1,024 samples). PGMY-CHUV was compared to the validated and commercially available linear array (Roche) on 200 samples. Both assays identified the same positive (n = 182) and negative samples (n = 18). Seventy-six percent of the positives were fully concordant after restricting the comparison to the 28 genotypes shared by both assays. At the genotypic level, agreement was 83% (285/344 genotype-sample combinations; κ of 0.987 for single infections and 0.853 for multiple infections). Fifty-seven of the 59 discordant cases were associated with multiple infections and with the weakest genotypes within each sample (P < 0.0001). PGMY-CHUV was significantly more sensitive for HPV56 (P = 0.0026) and could unambiguously identify HPV52 in mixed infections. PGMY-CHUV was reproducible on repeat testing (n = 275 samples; 392 genotype-sample combinations; κ of 0.933) involving different reagents lots and different technicians. Discordant results (n = 47) were significantly associated with the weakest genotypes in samples with multiple infections (P < 0.0001). Successful participation in proficiency testing also supported the robustness of this assay. The PGMY-CHUV reagent costs were estimated at $2.40 per sample using the least expensive yet proficient genotyping algorithm that also included quality control. This assay may be used in low-resource laboratories that have sufficient manpower and PCR expertise.