112 resultados para optic fiber sensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the percent decussation of pupil input fibers in humans and to explain the size and range of the log unit relative afferent pupillary defect (RAPD) in patients with optic tract lesions. DESIGN: Experimental study. PARTICIPANTS AND CONTROLS: Five patients with a unilateral optic tract lesion. METHODS: The pupil response from light stimulation of the nasal hemifield, temporal hemifield, and full field of each eye of 5 patients with a unilateral optic tract lesion was recorded using computerized binocular infrared pupillography. Six stimulus light intensities, separated by 0.5-log unit steps, were used; 12 stimulus repetitions were given for each stimulus condition. MAIN OUTCOME MEASURES: For each stimulus condition, the pupil response of each eye was characterized by plotting the mean pupil contraction amplitude as a function of stimulus light intensity. The percentage of decussating afferent pupillomotor input fibers was calculated from the ratio of the maximal pupil contractions elicited from each eye. The RAPD was determined pupillographically from full-field stimulation to each eye. RESULTS: In all patients, the pupil response from the functioning temporal hemifield ipsilateral to the tract lesion was greater than that from the functioning contralateral nasal hemifield. This temporal-nasal asymmetry increased with increasing stimulus intensity and was similar in hemifield and full-field stimuli, eventually saturating at maximal light intensity. The log unit RAPD did not correlate with the estimated percentage of decussating pupil fibers, which ranged from 54% to 67%. CONCLUSIONS: In patients with a unilateral optic tract lesion, the pupillary responses from full-field stimulation to each eye are the same as comparing the functioning temporal field with the functioning nasal field. The percentage of decussating fibers is reflected in the ratio of the maximal pupil contraction amplitudes resulting from stimulus input between the two eyes. The RAPD that occurs in this setting reflects the difference in light sensitivity between the intact temporal and nasal hemifields. Its magnitude does not correlate with the difference in the number of crossed and uncrossed axons, but its sidedness contralateral to the side of the optic tract lesion is consistent with the greater percentage of decussating pupillomotor input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure of the brain as a product of morphogenesis is difficult to reconcile with the observed complexity of cerebral connectivity. We therefore analyzed relationships of adjacency and crossing between cerebral fiber pathways in four nonhuman primate species and in humans by using diffusion magnetic resonance imaging. The cerebral fiber pathways formed a rectilinear three-dimensional grid continuous with the three principal axes of development. Cortico-cortical pathways formed parallel sheets of interwoven paths in the longitudinal and medio-lateral axes, in which major pathways were local condensations. Cross-species homology was strong and showed emergence of complex gyral connectivity by continuous elaboration of this grid structure. This architecture naturally supports functional spatio-temporal coherence, developmental path-finding, and incremental rewiring with correlated adaptation of structure and function in cerebral plasticity and evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficacy of optic nerve sheath decompression (ONSD) in treating non-arteritic ischemic optic neuropathy (NAION) is not clear. We retrospectively analyzed the records of 91 patients with NAION, who were examined during a two-year period, and compared the final Snellen visual acuities of eyes treated with ONSD with those of eyes that did not have surgery. Seven of 18 eyes with ONSD (39%) demonstrated increased visual acuity of two or more lines; whereas 23 of 71 eyes without surgery (32%) had increased acuity. The ONSD group and no surgery group were further subdivided into eyes with progressive visual loss and nonprogressive visual loss. No statistically significant differences in visual outcome between groups were found. We did not find the high frequency of visual improvement that has been reported in some studies of ONSD for NAION.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the root-colonizing biocontrol strain CHA0 of Pseudomonas fluorescens, cell density-dependent synthesis of extracellular, plant-beneficial secondary metabolites and enzymes is positively regulated by the GacS/GacA two-component system. Mutational analysis of the GacS sensor kinase using improved single-copy vectors showed that inactivation of each of the three conserved phosphate acceptor sites caused an exoproduct null phenotype (GacS-), whereas deletion of the periplasmic loop domain had no significant effect on the expression of exoproduct genes. Strain CHA0 is known to synthesize a solvent-extractable extracellular signal that advances and enhances the expression of exoproduct genes during the transition from exponential to stationary growth phase when maximal exoproduct formation occurs. Mutational inactivation of either GacS or its cognate response regulator GacA abolished the strain's response to added signal. Deletion of the linker domain of the GacS sensor kinase caused signal-independent, strongly elevated expression of exoproduct genes at low cell densities. In contrast to the wild-type strain CHA0, the gacS linker mutant and a gacS null mutant were unable to protect tomato plants from crown and root rot caused by Fusarium oxysporum f. sp. radicis-lycopersici in a soil-less microcosm, indicating that, at least in this plant-pathogen system, there is no advantage in using a signal-independent biocontrol strain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the pupil responses originating from outer versus inner retinal photoreception between patients with isolated hereditary optic neuropathy (HON, n = 8) and healthy controls (n = 8). Three different testing protocols were used. For the first two protocols, a response function of the maximal pupil contraction versus stimulus light intensity was generated and the intensity at which half of the maximal pupil contraction, the half-max intensity, was determined. For the third protocol, the pupil size after light offset, the re-dilation rate and re-dilation amplitude were calculated to assess the post-light stimulus response. Patients with HON had bilateral, symmetric optic atrophy and significant reduction of visual acuity and visual field compared to controls. There were no significant mean differences in the response curve and pupil response parameters that reflect mainly rod, cone or melanopsin activity between patients and controls. In patients, there was a significant correlation between the half-max intensity of the red light sequence and visual field loss. In conclusion, pupil responses derived from outer or inner retinal photoreception in HON patients having mild-to moderate visual dysfunction are not quantitatively different from age-matched controls. However, an association between the degree of visual field loss and the half-max intensity of the cone response suggests that more advanced stages of disease may lead to impaired pupil light reflexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In lentic water bodies, such as lakes, the water temperature near the surface typically increases during the day, and decreases during the night as a consequence of the diurnal radiative forcing (solar and infrared radiation). These temperature variations penetrate vertically into the water, transported mainly by heat conduction enhanced by eddy diffusion, which may vary due to atmospheric conditions, surface wave breaking, and internal dynamics of the water body. These two processes can be described in terms of an effective thermal diffusivity, which can be experimentally estimated. However, the transparency of the water (depending on turbidity) also allows solar radiation to penetrate below the surface into the water body, where it is locally absorbed (either by the water or by the deployed sensors). This process makes the estimation of effective thermal diffusivity from experimental water temperature profiles more difficult. In this study, we analyze water temperature profiles in a lake with the aim of showing that assessment of the role played by radiative forcing is necessary to estimate the effective thermal diffusivity. To this end we investigate diurnal water temperature fluctuations with depth. We try to quantify the effect of locally absorbed radiation and assess the impact of atmospheric conditions (wind speed, net radiation) on the estimation of the thermal diffusivity. The whole analysis is based on the results of fiber optic distributed temperature sensing, which allows unprecedented high spatial resolution measurements (∼4 mm) of the temperature profile in the water and near the water surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proteins can switch between different conformations in response to stimuli, such as pH or temperature variations, or to the binding of ligands. Such plasticity and its kinetics can have a crucial functional role, and their characterization has taken center stage in protein research. As an example, Topoisomerases are particularly interesting enzymes capable of managing tangled and supercoiled double-stranded DNA, thus facilitating many physiological processes. In this work, we describe the use of a cantilever-based nanomotion sensor to characterize the dynamics of human topoisomerase II (Topo II) enzymes and their response to different kinds of ligands, such as ATP, which enhance the conformational dynamics. The sensitivity and time resolution of this sensor allow determining quantitatively the correlation between the ATP concentration and the rate of Topo II conformational changes. Furthermore, we show how to rationalize the experimental results in a comprehensive model that takes into account both the physics of the cantilever and the dynamics of the ATPase cycle of the enzyme, shedding light on the kinetics of the process. Finally, we study the effect of aclarubicin, an anticancer drug, demonstrating that it affects directly the Topo II molecule inhibiting its conformational changes. These results pave the way to a new way of studying the intrinsic dynamics of proteins and of protein complexes allowing new applications ranging from fundamental proteomics to drug discovery and development and possibly to clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thanks to the continuous progress made in recent years, medical imaging has become an important tool in the diagnosis of various pathologies. In particular, magnetic resonance imaging (MRI) permits to obtain images with a remarkably high resolution without the use of ionizing radiation and is consequently widely applied for a broad range of conditions in all parts of the body. Contrast agents are used in MRI to improve tissue discrimination. Different categories of contrast agents are clinically available, the most widely used being gadolinium chelates. One can distinguish between extracellular gadolinium chelates such as Gd-DTPA, and hepatobiliary gadolinium chelates such as Gd-BOPTA. The latter are able to enter hepatocytes from where they are partially excreted into the bile to an extent dependent on the contrast agent and animal species. Due to this property, hepatobiliary contrast agents are particularly interesting for the MRI of the liver. Actually, a change in signal intensity can result from a change in transport functions signaling the presence of impaired hepatocytes, e.g. in the case of focal (like cancer) or diffuse (like cirrhosis) liver diseases. Although the excretion mechanism into the bile is well known, the uptake mechanisms of hepatobiliary contrast agents into hepatocytes are still not completely understood and several hypotheses have been proposed. As a good knowledge of these transport mechanisms is required to allow an efficient diagnosis by MRI of the functional state of the liver, more fundamental research is needed and an efficient MRI compatible in vitro model would be an asset. So far, most data concerning these transport mechanisms have been obtained by MRI with in vivo models or by a method of detection other than MRI with cellular or sub-cellular models. Actually, no in vitro model is currently available for the study and quantification of contrast agents by MRI notably because high cellular densities are needed to allow detection, and no metallic devices can be used inside the magnet room, which is incompatible with most tissue or cell cultures that require controlled temperature and oxygenation. The aim of this thesis is thus to develop an MRI compatible in vitro cellular model to study the transport of hepatobiliary contrast agents, in particular Gd-BOPTA, into hepatocytes directly by MRI. A better understanding of this transport and especially of its modification in case of hepatic disorder could permit in a second step to extrapolate this knowledge to humans and to use the kinetics of hepatobiliary contrast agents as a tool for the diagnosis of hepatic diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Microcystic macular edema can occur after optic neuropathies of various etiologies, and is easily demonstrated by OCT. We report a cohort of patients with microcystic macular edema. Patients and Methods: All patients with optic neuropathy and microcystic macular edema were enrolled. Demographics, visual function, retinal angiographies and OCT parameters were studied. Results: Nineteen patients (23 eyes) exhibited microcystic macular edema: 10 men/9 women, aged 17-91 years. Etiologies of optic nerve atrophy were compressive (5), inflammatory (4), glaucoma (3), ischemic (3), trauma (2), degenerative (1), and hereditary (1). Median visual acuity was 4/10 (NLP-12/10). Fluorescein angiography showed no leakage. Topography of the microcystic macular edema correlated with near infrared images but with visual field defects in only 26 %. OCT parameters were all abnormal. Conclusions: Microcystic macular edema is a non-specific manifestation from an optic neuropathy of any etiology. The precise mechanism leading to microcystic macular edema remains unknown but trans-synaptic retrograde degeneration with Müller cells dysfunction is likely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 48-year-old man was examined 24 months after medial and surgical treatment of an isolated well-circumscribed right occipital lobe abscess. An asymptomatic residual left homonymous inferior scotoma was present. Fundus examination revealed temporal pallor of both optic discs, and optical coherence tomography (OCT) revealed mild temporal loss of retinal nerve fiber layer in both eyes. No relative afferent pupillary defect was present. Assessment of the retinal ganglion cell layer demonstrated homonymous thinning in a pattern corresponding to the homonymous visual field loss. There were no abnormalities of the lateral geniculate nuclei or optic tracts on review of the initial brain computed tomography and follow-up magnetic resonance imaging. We believe our patient showed evidence of transsynaptic retrograde degeneration after an isolated right occipital lobe lesion, and the homonymous neuronal loss was detected on OCT by assessing the retinal ganglion cell layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the effect of anterior ischemic optic neuropathy (AION) on the activity of intrinsically photosensitive retinal ganglion cells (ipRGCs) using the pupil as proxy. Eighteen patients with AION (10 unilateral, 8 bilateral) and 29 age-matched control subjects underwent chromatic pupillometry. Red and blue light stimuli increasing in 0.5 log steps were presented to each eye independently under conditions of dark and light adaptation. The recorded pupil contraction was plotted against stimulus intensity to generate scotopic and photopic response curves for assessment of synaptically-mediated ipRGC activity. Bright blue light stimuli presented monocularly and binocularly were used for melanopsin activation. The post-stimulus pupil size (PSPS) at the 6th second following stimulus offset was the marker of intrinsic ipRGC activity. Finally, questionnaires were administered to assess the influence of ipRGCs on sleep. The pupil response and PSPS to all monocularly-presented light stimuli were impaired in AION eyes, indicating ipRGC dysfunction. To binocular light stimulation, the PSPS of AION patients was similar to that of controls. There was no difference in the sleep habits of the two groups. Thus after ischemic injury to one or both optic nerves, the summated intrinsic ipRGC activity is preserved when both eyes receive adequate light exposure.