110 resultados para microvascular density
Resumo:
The trabecular bone score (TBS) is an index of bone microarchitectural texture calculated from anteroposterior dual-energy X-ray absorptiometry (DXA) scans of the lumbar spine (LS) that predicts fracture risk, independent of bone mineral density (BMD). The aim of this study was to compare the effects of yearly intravenous zoledronate (ZOL) versus placebo (PLB) on LS BMD and TBS in postmenopausal women with osteoporosis. Changes in TBS were assessed in the subset of 107 patients recruited at the Department of Osteoporosis of the University Hospital of Berne, Switzerland, who were included in the HORIZON trial. All subjects received adequate calcium and vitamin D3. In these patients randomly assigned to either ZOL (n = 54) or PLB (n = 53) for 3 years, BMD was measured by DXA and TBS assessed by TBS iNsight (v1.9) at baseline and 6, 12, 24, and 36 months after treatment initiation. Baseline characteristics (mean ± SD) were similar between groups in terms of age, 76.8 ± 5.0 years; body mass index (BMI), 24.5 ± 3.6 kg/m(2) ; TBS, 1.178 ± 0.1 but for LS T-score (ZOL-2.9 ± 1.5 versus PLB-2.1 ± 1.5). Changes in LS BMD were significantly greater with ZOL than with PLB at all time points (p < 0.0001 for all), reaching +9.58% versus +1.38% at month 36. Change in TBS was significantly greater with ZOL than with PLB as of month 24, reaching +1.41 versus-0.49% at month 36; p = 0.031, respectively. LS BMD and TBS were weakly correlated (r = 0.20) and there were no correlations between changes in BMD and TBS from baseline at any visit. In postmenopausal women with osteoporosis, once-yearly intravenous ZOL therapy significantly increased LS BMD relative to PLB over 3 years and TBS as of 2 years. © 2013 American Society for Bone and Mineral Research.
Resumo:
INTRODUCTION: One quarter of osteoporotic fractures occur in men. TBS, a gray-level measurement derived from lumbar spine DXA image texture, is related to microarchitecture and fracture risk independently of BMD. Previous studies reported the ability of spine TBS to predict osteoporotic fractures in women. Our aim was to evaluate the ability of TBS to predict clinical osteoporotic fractures in men. METHODS: 3620 men aged ≥50 (mean 67.6years) at the time of baseline DXA (femoral neck, spine) were identified from a database (Province of Manitoba, Canada). Health service records were assessed for the presence of non-traumatic osteoporotic fracture after BMD testing. Lumbar spine TBS was derived from spine DXA blinded to clinical parameters and outcomes. We used Cox proportional hazard regression to analyze time to first fracture adjusted for clinical risk factors (FRAX without BMD), osteoporosis treatment and BMD (hip or spine). RESULTS: Mean followup was 4.5years. 183 (5.1%) men sustain major osteoporotic fractures (MOF), 91 (2.5%) clinical vertebral fractures (CVF), and 46 (1.3%) hip fractures (HF). Correlation between spine BMD and spine TBS was modest (r=0.31), less than correlation between spine and hip BMD (r=0.63). Significantly lower spine TBS were found in fracture versus non-fracture men for MOF (p<0.001), HF (p<0.001) and CVF (p=0.003). Area under the receiver operating characteristic curve (AUC) for incident fracture discrimination with TBS was significantly better than chance (MOF AUC=0.59, p<0.001; HF AUC=0.67, p<0.001; CVF AUC=0.57, p=0.032). TBS predicted MOF and HF (but not CVF) in models adjusted for FRAX without BMD and osteoporosis treatment. TBS remained a predictor of HF (but not MOF) after further adjustment for hip BMD or spine BMD. CONCLUSION: We observed that spine TBS predicted MOF and HF independently of the clinical FRAX score, HF independently of FRAX and BMD in men. Studies with more incident fractures are needed to confirm these findings.
Resumo:
Une lésion fonctionnelle ou structurale des artérioles intramurales influence le seuil ischémique du myocarde. Le diagnostic de dysfonction microvasculaire est retenu en présence d'une diminution du flux coronaire maximal et de coronaires angio-graphiquement normales ou presque normales. Un trouble de la microcirculation peut traduire une dysfonction endothéliale chez le sujet diabétique ou hyperlipidémique, ou une lésion structurale ou fonctionnelle dans le cadre de la cardiomyopathie hypertrophique, la sténose aortique ou l'hypertension artérielle. Après recanalisation de l'artère responsable d'un infarctus, la mesure de la fonction microcirculatoire permet d'estimer la qualité de la reperfusion myocardique. L'appréciation de la fonction microvasculaire est un enjeu majeur dans l'évaluation de l'ischémie du myocarde en l'absence de sténose coronaire. Functional or structural lesions in intramural arterioles influence the ischemic threshold of the myocardium. Microvascular dysfonction is evidenced by a decrease in coronary blood flow during maximum hyperemia in the presence of angiographically normal or near-normal coronary arteries. Microvascular dysfonction may reflect endothelial dysfonction in diabetic or hyperlipidemic patients, as well as structural and functional changes in patients with hypertrophic cardiomyopathy, aortic stenosis or hypertension. Assessing microvascular fonction after thrombolysis or primary angioplasty for acute myocardial infarction allows to estimate the quality of myocardial reperfusion. Assessing microvascular fonction is a major component of the evaluation of myocardial ischemia in the absence of coronary artery stenoses.
Resumo:
Bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA) is used to diagnose osteoporosis and assess fracture risk. However, DXA cannot evaluate trabecular microarchitecture. This study used a novel software program (TBS iNsight; Med-Imaps, Geneva, Switzerland) to estimate bone texture (trabecular bone score [TBS]) from standard spine DXA images. We hypothesized that TBS assessment would differentiate women with low trauma fracture from those without. In this study, TBS was performed blinded to fracture status on existing research DXA lumbar spine (LS) images from 429 women. Mean participant age was 71.3 yr, and 158 had prior fractures. The correlation between LS BMD and TBS was low (r = 0.28), suggesting these parameters reflect different bone properties. Age- and body mass index-adjusted odds ratios (ORs) ranged from 1.36 to 1.63 for LS or hip BMD in discriminating women with low trauma nonvertebral and vertebral fractures. TBS demonstrated ORs from 2.46 to 2.49 for these respective fractures; these remained significant after lowest BMD T-score adjustment (OR = 2.38 and 2.44). Seventy-three percent of all fractures occurred in women without osteoporosis (BMD T-score > -2.5); 72% of these women had a TBS score below the median, thereby appropriately classified them as being at increased risk. In conclusion, TBS assessment enhances DXA by evaluating trabecular pattern and identifying individuals with vertebral or low trauma fracture. TBS identifies 66-70% of women with fracture who were not classified with osteoporosis by BMD alone.
Resumo:
Dose kernel convolution (DK) methods have been proposed to speed up absorbed dose calculations in molecular radionuclide therapy. Our aim was to evaluate the impact of tissue density heterogeneities (TDH) on dosimetry when using a DK method and to propose a simple density-correction method. METHODS: This study has been conducted on 3 clinical cases: case 1, non-Hodgkin lymphoma treated with (131)I-tositumomab; case 2, a neuroendocrine tumor treatment simulated with (177)Lu-peptides; and case 3, hepatocellular carcinoma treated with (90)Y-microspheres. Absorbed dose calculations were performed using a direct Monte Carlo approach accounting for TDH (3D-RD), and a DK approach (VoxelDose, or VD). For each individual voxel, the VD absorbed dose, D(VD), calculated assuming uniform density, was corrected for density, giving D(VDd). The average 3D-RD absorbed dose values, D(3DRD), were compared with D(VD) and D(VDd), using the relative difference Δ(VD/3DRD). At the voxel level, density-binned Δ(VD/3DRD) and Δ(VDd/3DRD) were plotted against ρ and fitted with a linear regression. RESULTS: The D(VD) calculations showed a good agreement with D(3DRD). Δ(VD/3DRD) was less than 3.5%, except for the tumor of case 1 (5.9%) and the renal cortex of case 2 (5.6%). At the voxel level, the Δ(VD/3DRD) range was 0%-14% for cases 1 and 2, and -3% to 7% for case 3. All 3 cases showed a linear relationship between voxel bin-averaged Δ(VD/3DRD) and density, ρ: case 1 (Δ = -0.56ρ + 0.62, R(2) = 0.93), case 2 (Δ = -0.91ρ + 0.96, R(2) = 0.99), and case 3 (Δ = -0.69ρ + 0.72, R(2) = 0.91). The density correction improved the agreement of the DK method with the Monte Carlo approach (Δ(VDd/3DRD) < 1.1%), but with a lesser extent for the tumor of case 1 (3.1%). At the voxel level, the Δ(VDd/3DRD) range decreased for the 3 clinical cases (case 1, -1% to 4%; case 2, -0.5% to 1.5%, and -1.5% to 2%). No more linear regression existed for cases 2 and 3, contrary to case 1 (Δ = 0.41ρ - 0.38, R(2) = 0.88) although the slope in case 1 was less pronounced. CONCLUSION: This study shows a small influence of TDH in the abdominal region for 3 representative clinical cases. A simple density-correction method was proposed and improved the comparison in the absorbed dose calculations when using our voxel S value implementation.
Resumo:
Osteoporosis (OP) is a systemic skeletal disease characterized by a low bone mineral density (BMD) and a micro-architectural (MA) deterioration. Clinical risk factors (CRF) are often used as a MA approximation. MA is yet evaluable in daily practice by the trabecular bone score (TBS) measure. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis values, partially independent of CRF and BMD. The aim of the OsteoLaus cohort is to combine in daily practice the CRF and the information given by DXA (BMD, TBS and vertebral fracture assessment (VFA)) to better identify women at high fracture risk. The OsteoLaus cohort (1400 women 50 to 80 years living in Lausanne, Switzerland) started in 2010. This study is derived from the cohort COLAUS who started in Lausanne in 2003. The main goal of COLAUS is to obtain information on the epidemiology and genetic determinants of cardiovascular risk in 6700 men and women. CRF for OP, bone ultrasound of the heel, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded in OsteoLaus. Preliminary results are reported. We included 631 women: mean age 67.4 ± 6.7 years, BMI 26.1 ± 4.6, mean lumbar spine BMD 0.943 ± 0.168 (T-score − 1.4 SD), and TBS 1.271 ± 0.103. As expected, correlation between BMD and site matched TBS is low (r2 = 0.16). Prevalence of VFx grade 2/3, major OP Fx and all OP Fx is 8.4%, 17.0% and 26.0% respectively. Age- and BMI-adjusted ORs (per SD decrease) are 1.8 (1.2-2.5), 1.6 (1.2-2.1), and 1.3 (1.1-1.6) for BMD for the different categories of fractures and 2.0 (1.4-3.0), 1.9 (1.4-2.5), and 1.4 (1.1-1.7) for TBS respectively. Only 32 to 37% of women with OP Fx have a BMD < − 2.5 SD or a TBS < 1.200. If we combine a BMD < − 2.5 SD or a TBS < 1.200, 54 to 60% of women with an osteoporotic Fx are identified. As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS subsequent to BMD increases significantly the identification of women with prevalent OP Fx which would have been misclassified by BMD alone. For the first time we are able to have complementary information about fracture (VFA), density (BMD), micro- and macro architecture (TBS and HAS) from a simple, low ionizing radiation and cheap device: DXA. Such complementary information is very useful for the patient in the daily practice and moreover will likely have an impact on cost effectiveness analysis.
Resumo:
The effectiveness of lipid-lowering medication critically depends on the patients' compliance and the efficacy of the prescribed drug. The primary objective of this multicentre study was to compare the efficacy of rosuvastatin with or without access to compliance initiatives, in bringing patients to the Joint European Task Force's (1998) recommended low-density lipoprotein cholesterol (LDL-C) level goal (LDL-C, <3.0 mmol/L) at week 24. Secondary objectives were comparison of the number and percentage of patients achieving European goals (1998, 2003) for LDL-C and other lipid parameters. Patients with primary hypercholesterolaemia and a 10-year coronary heart disease risk of >20% received open label rosuvastatin treatment for 24 weeks with or without access to compliance enhancement tools. The initial daily dosage of 10 mg could be doubled at week 12. Compliance tools included: a) a starter pack for subjects containing a videotape, an educational leaflet, a passport/goal diary and details of the helpline and/or website; b) regular personalised letters to provide message reinforcement; c) a toll-free helpline and a website. The majority of patients (67%) achieved the 1998 European goal for LDL-C at week 24. 31% required an increase in dosage of rosuvastatin to 20 mg at week 12. Compliance enhancement tools did not increase the number of patients achieving either the 1998 or the 2003 European target for plasma lipids. Rosuvastatin was well tolerated during this study. The safety profile was comparable with other drugs of the same class. 63 patients in the 10 mg group and 58 in the 10 mg Plus group discontinued treatment. The main reasons for discontinuation were adverse events (39 patients in the 10 mg group; 35 patients in the 10 mg Plus group) and loss to follow-up (13 patients in the 10 mg group; 9 patients in the 10 mg Plus group). The two most frequently reported adverse events were myalgia (34 patients, 3% respectively) and back pain (23 patients, 2% respectively). The overall rate of temporary or permanent study discontinuation due to adverse events was 9% (n = 101) in patients receiving 10 mg rosuvastatin and 3% (n = 9) in patients titrated up to 20 mg rosuvastatin. Rosuvastatin was effective in lowering LDL-C values in patients with hypercholesterolaemia to the 1998 European target at week 24. However, compliance enhancement tools did not increase the number of patients achieving any European targets for plasma lipids.
Resumo:
AIMS/HYPOTHESIS: We explored the potential adverse effects of pro-atherogenic oxidised LDL-cholesterol particles on beta cell function. MATERIALS AND METHODS: Isolated human and rat islets and different insulin-secreting cell lines were incubated with human oxidised LDL with or without HDL particles. The insulin level was monitored by ELISA, real-time PCR and a rat insulin promoter construct linked to luciferase gene reporter. Cell apoptosis was determined by scoring cells displaying pycnotic nuclei. RESULTS: Prolonged incubation with human oxidised LDL particles led to a reduction in preproinsulin expression levels, whereas the insulin level was preserved in the presence of native LDL-cholesterol. The loss of insulin production occurred at the transcriptional levels and was associated with an increase in activator protein-1 transcriptional activity. The rise in activator protein-1 activity resulted from activation of c-Jun N-terminal kinases (JNK, now known as mitogen-activated protein kinase 8 [MAPK8]) due to a subsequent decrease in islet-brain 1 (IB1; now known as MAPK8 interacting protein 1) levels. Consistent with the pro-apoptotic role of the JNK pathway, oxidised LDL also induced a twofold increase in the rate of beta cell apoptosis. Treatment of the cells with JNK inhibitor peptides or HDL countered the effects mediated by oxidised LDL. CONCLUSIONS/INTERPRETATION: These data provide strong evidence that oxidised LDL particles exert deleterious effects in the progression of beta cell failure in diabetes and that these effects can be countered by HDL particles.
Resumo:
In a system where tens of thousands of words are made up of a limited number of phonemes, many words are bound to sound alike. This similarity of the words in the lexicon as characterized by phonological neighbourhood density (PhND) has been shown to affect speed and accuracy of word comprehension and production. Whereas there is a consensus about the interfering nature of neighbourhood effects in comprehension, the language production literature offers a more contradictory picture with mainly facilitatory but also interfering effects reported on word production. Here we report both of these two types of effects in the same study. Multiple regression mixed models analyses were conducted on PhND effects on errors produced in a naming task by a group of 21 participants with aphasia. These participants produced more formal errors (interfering effect) for words in dense phonological neighbourhoods, but produced fewer nonwords and semantic errors (a facilitatory effect) with increasing density. In order to investigate the nature of these opposite effects of PhND, we further analysed a subset of formal errors and nonword errors by distinguishing errors differing on a single phoneme from the target (corresponding to the definition of phonological neighbours) from those differing on two or more phonemes. This analysis confirmed that only formal errors that were phonological neighbours of the target increased in dense neighbourhoods, while all other errors decreased. Based on additional observations favouring a lexical origin of these formal errors (they exceeded the probability of producing a real-word error by chance, were of a higher frequency, and preserved the grammatical category of the targets), we suggest that the interfering effect of PhND is due to competition between lexical neighbours and target words in dense neighbourhoods.
Resumo:
We present the optical properties of Na0.7CoO2 single crystals, measured over a broad spectral range as a function of temperature (T). The capability to cover the energy range from the far-infrared up to the ultraviolet allows us to perform reliable Kramers-Kronig transformation, in order to obtain the absorption spectrum (i.e., the complex optical conductivity). To the complex optical conductivity we apply the generalized Drude model, extracting the frequency dependence of the scattering rate (Gamma) and effective mass (m*) of the itinerant charge carriers. We find that Gamma(omega) at low temperatures and for similar to omega. This suggests that Na0.7CoO2 is at the verge of a spin-density-wave metallic phase.
Resumo:
Tools to predict fracture risk are useful for selecting patients for pharmacological therapy in order to reduce fracture risk and redirect limited healthcare resources to those who are most likely to benefit. FRAX® is a World Health Organization fracture risk assessment algorithm for estimating the 10-year probability of hip fracture and major osteoporotic fracture. Effective application of FRAX® in clinical practice requires a thorough understanding of its limitations as well as its utility. For some patients, FRAX® may underestimate or overestimate fracture risk. In order to address some of the common issues encountered with the use of FRAX® for individual patients, the International Society for Clinical Densitometry (ISCD) and International Osteoporosis Foundation (IOF) assigned task forces to review the medical evidence and make recommendations for optimal use of FRAX® in clinical practice. Among the issues addressed were the use of bone mineral density (BMD) measurements at skeletal sites other than the femoral neck, the use of technologies other than dual-energy X-ray absorptiometry, the use of FRAX® without BMD input, the use of FRAX® to monitor treatment, and the addition of the rate of bone loss as a clinical risk factor for FRAX®. The evidence and recommendations were presented to a panel of experts at the Joint ISCD-IOF FRAX® Position Development Conference, resulting in the development of Joint ISCD-IOF Official Positions addressing FRAX®-related issues.
Resumo:
One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.