125 resultados para metal oxide conductor phototransistor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Jebel Ressas Pb-Zn deposits in North-Eastern Tunisia occur mainly as open-space fillings (lodes, tectonic breccia cements) in bioclastic limestones of the Upper Jurassic Ressas Formation and along the contact of this formation with Triassic rocks. The galena-sphalerite association and their alteration products (cerussite, hemimorphite, hydrozincite) are set within a calcite gangue. The Triassic rocks exhibit enrichments in trace metals, namely Pb, Co and Cd enrichment in clays and Pb, Zn, Cd, Co and Cr enrichment in carbonates, suggesting that the Triassic rocks have interacted with the ore-bearing fluids associated with the Jebel Ressas Pb-Zn deposits. The delta(18)O content of calcite associated with the Pb-Zn mineralization suggests that it is likely to have precipitated from a fluid that was in equilibrium with the Triassic dolostones. The delta(34)S values in galenas from the Pb-Zn deposits range from -1.5 to +11.4%, with an average of 5.9% and standard deviation of 3.9%. These data imply mixing of thermochemically-reduced heavy sulfur carried in geothermal- and fault-stress-driven deep-seated source fluid with bacterially-reduced light sulfur carried in topography-driven meteoric fluid. Lead isotope ratios in galenas from the Pb-Zn deposits are homogenous and indicate a single upper crustal source of base-metals for these deposits. Synthesis of the geochemical data with geological data suggests that the base-metal mineralization at Jebel Ressas was formed during the Serravallian-Tortonian (or Middle-Late Miocene) Alpine compressional tectonics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this review was to systematically evaluate and compare the frequency of veneer chipping and core fracture of zirconia fixed dental prostheses (FOPS) and porcelain-fused-to-metal (PFM) FDPs and determine possible influencing factors. Materials and Methods: The SCOPUS database and International Association of Dental Research abstracts were searched for clinical studies involving zirconia and PFM FDPs. Furthermore, studies that were integrated into systematic reviews on PFM FDPs were also evaluated. The principle investigators of any clinical studies on zirconia FDPs were contacted to provide additional information. Based on the available information for each FOP, a data file was constructed. Veneer chipping was divided into three grades (grade 1 = polishing, grade 2 = repair, grade 3 = replacement). To assess the frequency of veneer chipping and possible influencing factors, a piecewise exponential model was used to adjust for a study effect. Results: None of the studies on PFM FDPs (reviews and additional searching) sufficiently satisfied the criteria of this review to be included. Thirteen clinical studies on zirconia FDPs and two studies that investigated both zirconia and PFM FDPs were identified. These studies involved 664 zirconia and 134 PFM FDPs at baseline. Follow-up data were available for 595 zirconia and 127 PFM FDPs. The mean observation period was approximately 3 years for both groups. The frequency of core fracture was less than 1% in the zirconia group and 0% in the PFM group. When all studies were included, 142 veneer chippings were recorded for zirconia FDPs (24%) and 43 for PFM FDPs (34%). However, the studies differed extensively with regard to veneer chipping of zirconia: 85% of all chippings occurred in 4 studies, and 43% of all chippings included zirconia FDPs. If only studies that evaluated both types of core materials were included, the frequency of chipping was 54% for the zirconia-supported FDPs and 34% for PFM FDPs. When adjusting the survival rate for the study effect, the difference between zirconia and PFM FDPs was statistically significant for all grades of chippings (P = .001), as well as for chipping grade 3 (P = .02). If all grades of veneer chippings were taken into account, the survival of PFM FDPs was 97%, while the survival rate of the zirconia FDPs was 90% after 3 years for a typical study. For both PFM and zirconia FDPs, the frequency of grades 1 and 2 veneer chippings was considerably higher than grade 3. Veneer chipping was significantly less frequent in pressed materials than in hand-layered materials, both for zirconia and PFM FDPs (P = .04). Conclusions: Since the frequency of veneer chipping was significantly higher in the zirconia FDPs than PFM FDPs, and as refined processing procedures have started to yield better results in the laboratory, new clinical studies with these new procedures must confirm whether the frequency of veneer chipping can be reduced to the level of PFM. Int J Prosthodont 2010;23:493-502

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Slight differences in physiological responses and nitric oxide (NO) have been reported at rest between hypobaric hypoxia (HH) and normobaric hypoxia (NH) during short exposure.Our study reports NO and oxidative stress at rest and physiological responses during moderate exercise in HH versus NH. METHODS: Ten subjects were randomly exposed for 24 h to HH (3000 m; FIO2, 20.9%; BP, 530 ± 6 mm Hg) or to NH (FIO2, 14.7%; BP, 720 ± 1 mm Hg). Before and every 8 h during the hypoxic exposures, pulse oxygen saturation (SpO2), HR, and gas exchanges were measured during a 6-min submaximal cycling exercise. At rest, the partial pressure of exhaled NO, blood nitrate and nitrite (NOx), plasma levels of oxidative stress, and pH levels were additionally measured. RESULTS: During exercise, minute ventilation was lower in HH compared with NH (-13% after 8 h, P < 0.05). End-tidal CO2 pressure was lower (P < 0.01) than PRE both in HH and NH but decreased less in HH than that in NH (-25% vs -37%, P < 0.05).At rest, exhaled NO and NOx decreased in HH (-46% and -36% after 24 h, respectively, P < 0.05) whereas stable in NH. By contrast, oxidative stress was higher in HH than that in NH after 24 h (P < 0.05). The plasma pH level was stable in HH but increased in NH (P < 0.01). When compared with prenormoxic values, SpO2, HR, oxygen consumption, breathing frequency, and end-tidal O2 pressure showed similar changes in HH and NH. CONCLUSION: Lower ventilatory responses to a similar hypoxic stimulus during rest and exercise in HH versus NH were sustained for 24 h and associated with lower plasma pH level, exaggerated oxidative stress, and impaired NO bioavailability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies demonstrate an association between insulin resistance, hypertension and cardiovascular morbidity. In addition to its metabolic effects, insulin also has important cardiovascular actions. The sympathetic nervous system and the nitric oxide-l-arginine pathway have emerged as central players in the mediation of these actions. Over the past decade, the underlying mechanisms and the factors that may govern the interaction between insulin and these two major cardiovascular regulatory systems have been studied extensively in healthy people and insulin-resistant individuals. Here we summarize the current understanding and gaps in knowledge on these interactions. We propose that a genetic and/or acquired defect of nitric oxide synthesis could represent a central defect triggering many of the metabolic, vascular and sympathetic abnormalities characteristic of insulin-resistant states, all of which may predispose to cardiovascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Connexins (Cxs) and endothelial nitric oxide synthase (eNOS) contribute to the adaptation of endothelial and smooth muscle cells to hemodynamic changes. To decipher the in vivo interplay between these proteins, we studied Cx40-null mice, a model of renin-dependent hypertension which displays an altered endothelium-dependent relaxation of the aorta because of reduced eNOS levels. These mice, which were either untreated or subjected to the 1-kidney, 1-clip (1K1C) procedure, a model of volume-dependent hypertension, were compared with control mice submitted to either the 1K1C or the 2-kidney, 1-clip (2K1C) procedure, a model of renin-dependent hypertension. All operated mice became hypertensive and featured hypertrophy and altered Cx expression of the aorta. The combination of volume- and renin-dependent hypertension in Cx40-/- 1K1C mice raised blood pressure and cardiac weight index. Under these conditions, all aortas showed increased levels of Cx40 in endothelial cells and of both Cx37 and Cx45 in smooth muscle cells. In the wild-type 1K1C mice, the interactions between Cx40 and Cx37 with eNOS were enhanced, resulting in increased NO release. The Cx40-eNOS interaction could not be observed in mice lacking Cx40, which also featured decreased levels of eNOS. In these animals, the volume overload caused by the 1K1C procedure resulted in increased phosphorylation of eNOS and in a higher NO release. The findings provide evidence that Cx40 and Cx37 play an in vivo role in the regulation of eNOS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Aerosol-mediated delivery of nano-based therapeutics to the lung has emerged as a promising alternative for treatment and prevention of lung diseases. Superparamagnetic iron oxide nanoparticles (SPIONs) have attracted significant attention for such applications due to their biocompatibility and magnetic properties. However, information is lacking about the characteristics of nebulized SPIONs for use as a therapeutic aerosol. To address this need, we conducted a physicochemical characterization of nebulized Rienso, a SPION-based formulation for intravenous treatment of anemia. Methods: Four different concentrations of SPION suspensions were nebulized with a one-jet nebulizer. Particle size was measured in suspension by transmission electron microscopy (TEM), photon correlation spectroscopy (PCS), and nanoparticle tracking analysis (NTA), and in the aerosol by a scanning mobility particle sizer (SMPS). Results: The average particle size in suspension as measured by TEM, PCS, and NTA was 9±2 nm, 27±7 nm, and 56±10 nm, respectively. The particle size in suspension remained the same before and after the nebulization process. However, after aerosol collection in an impinger, the suspended particle size increased to 159±46 nm as measured by NTA. The aerosol particle concentration increased linearly with increasing suspension concentration, and the aerodynamic diameter remained relatively stable at around 75 nm as measured by SMPS. Conclusions: We demonstrated that the total number and particle size in the aerosol were modulated as a function of the initial concentration in the nebulizer. The data obtained mark the first known independent characterization of nebulized Rienso and, as such, provide critical information on the behavior of Rienso nanoparticles in an aerosol. The data obtained in this study add new knowledge to the existing body of literature on potential applications of SPION suspensions as inhaled aerosol therapeutics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endothelial cell release of nitric oxide (NO) is a defining characteristic of nondiseased arteries, and abnormal endothelial NO release is both a marker of early atherosclerosis and a predictor of its progression and future events. Healthy coronaries respond to endothelial-dependent stressors with vasodilatation and increased coronary blood flow (CBF), but those with endothelial dysfunction respond with paradoxical vasoconstriction and reduced CBF. Recently, coronary MRI and isometric handgrip exercise (IHE) were reported to noninvasively quantify coronary endothelial function (CEF). However, it is not known whether the coronary response to IHE is actually mediated by NO and/or whether it is reproducible over weeks. To determine the contribution of NO, we studied the coronary response to IHE before and during infusion of N(G)-monomethyl-l-arginine (l-NMMA, 0.3 mg·kg(-1)·min(-1)), a NO-synthase inhibitor, in healthy volunteers. For reproducibility, we performed two MRI-IHE studies ∼8 wk apart in healthy subjects and patients with coronary artery disease (CAD). Changes from rest to IHE in coronary cross-sectional area (%CSA) and diastolic CBF (%CBF) were quantified. l-NMMA completely blocked normal coronary vasodilation during IHE [%CSA, 12.9 ± 2.5 (mean ± SE, placebo) vs. -0.3 ± 1.6% (l-NMMA); P < 0.001] and significantly blunted the increase in flow [%CBF, 47.7 ± 6.4 (placebo) vs. 10.6 ± 4.6% (l-NMMA); P < 0.001]. MRI-IHE measures obtained weeks apart strongly correlated for CSA (P < 0.0001) and CBF (P < 0.01). In conclusion, the normal human coronary vasoactive response to IHE is primarily mediated by NO. This noninvasive, reproducible MRI-IHE exam of NO-mediated CEF promises to be useful for studying CAD pathogenesis in low-risk populations and for evaluating translational strategies designed to alter CAD in patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recently, it has been suggested that the type of stent used in primary percutaneous coronary interventions (pPCI) might impact upon the outcomes of patients with acute myocardial infarction (AMI). Indeed, drug-eluting stents (DES) reduce neointimal hyperplasia compared to bare-metal stents (BMS). Moreover, the later generation DES, due to its biocompatible polymer coatings and stent design, allows for greater deliverability, improved endothelial healing and therefore less restenosis and thrombus generation. However, data on the safety and performance of DES in large cohorts of AMI is still limited. AIM: To compare the early outcome of DES vs. BMS in AMI patients. METHODS: This was a prospective, multicentre analysis containing patients from 64 hospitals in Switzerland with AMI undergoing pPCI between 2005 and 2013. The primary endpoint was in-hospital all-cause death, whereas the secondary endpoint included a composite measure of major adverse cardiac and cerebrovascular events (MACCE) of death, reinfarction, and cerebrovascular event. RESULTS: Of 20,464 patients with a primary diagnosis of AMI and enrolled to the AMIS Plus registry, 15,026 were referred for pPCI and 13,442 received stent implantation. 10,094 patients were implanted with DES and 2,260 with BMS. The overall in-hospital mortality was significantly lower in patients with DES compared to those with BMS implantation (2.6% vs. 7.1%,p < 0.001). The overall in-hospital MACCE after DES was similarly lower compared to BMS (3.5% vs. 7.6%, p < 0.001). After adjusting for all confounding covariables, DES remained an independent predictor for lower in-hospital mortality (OR 0.51,95% CI 0.40-0.67, p < 0.001). Since groups differed as regards to baseline characteristics and pharmacological treatment, we performed a propensity score matching (PSM) to limit potential biases. Even after the PSM, DES implantation remained independently associated with a reduced risk of in-hospital mortality (adjusted OR 0.54, 95% CI 0.39-0.76, p < 0.001). CONCLUSIONS: In unselected patients from a nationwide, real-world cohort, we found DES, compared to BMS, was associated with lower in-hospital mortality and MACCE. The identification of optimal treatment strategies of patients with AMI needs further randomised evaluation; however, our findings suggest a potential benefit with DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inducible nitric oxide synthase (iNOS) production of nitric oxide (NO) has been mostly associated with so-called nitrosative stress or interaction with superoxide anion. However, recent investigations have indicated that, as for the other isoenzymes producing NO, guanylyl cyclase (GC) is a very sensitive target of iNOS activity. To further investigate this less explored signaling, the NO-cyclic guanosine 3'-5'-monophosphate (NO-cGMP)-induced vasodilator-stimulated phosphoprotein (VASP) phosphorylation on serine 239 was investigated in human embryonic kidney 293 cells (HEK cells). First, the expression and activity of alpha2 and beta1 NO-sensitive GC subunits was determined by Western blot analysis, reverse transcription-polymerase chain reaction and NO donors administration. Then, the expression of a functional cGMP-dependent protein kinase I (PKGI) was verified by addition of 8-Br-cGMP followed by determination of phosphorylation of VASP on serine 239. Finally, iNOS activation of this signaling pathway was characterized after transfection of HEK cells with human iNOS cDNA. Altogether our data show that iNOS-derived NO activates endogenous NO-sensitive GC and leads to VASP phosphorylation in HEK cells.