96 resultados para magnetic rotor center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biological and therapeutic responses to hyperthermia, when it is envisaged as an anti-tumor treatment modality, are complex and variable. Heat delivery plays a critical role and is counteracted by more or less efficient body cooling, which is largely mediated by blood flow. In the case of magnetically mediated modality, the delivery of the magnetic particles, most often superparamagnetic iron oxide nanoparticles (SPIONs), is also critically involved. We focus here on the magnetic characterization of two injectable formulations able to gel in situ and entrap silica microparticles embedding SPIONs. These formulations have previously shown suitable syringeability and intratumoral distribution in vivo. The first formulation is based on alginate, and the second on a poly(ethylene-co-vinyl alcohol) (EVAL). Here we investigated the magnetic properties and heating capacities in an alternating magnetic field (141 kHz, 12 mT) for implants with increasing concentrations of magnetic microparticles. We found that the magnetic properties of the magnetic microparticles were preserved using the formulation and in the wet implant at 37 degrees C, as in vivo. Using two orthogonal methods, a common SLP (20 Wg(-1)) was found after weighting by magnetic microparticle fraction, suggesting that both formulations are able to properly carry the magnetic microparticles in situ while preserving their magnetic properties and heating capacities. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The PERFORM MRI Project was an ancillary study of the PERFORM trial. Its aim was to investigate the potential effects of terutroban in patients with atherothrombotic disorders, in comparison to aspirin, on the evolution of magnetic resonance imaging (MRI) lesions after a recent ischemic stroke or transient ischemic attack (TIA). The change in both hypointense and hyperintense lesions on the fluid attenuated inversion recovery (FLAIR) sequence, in the total brain volume and in the hippocampal volume from baseline (M1) to the final visit (M24) was assessed as well as the number of emergent microbleeds. A total of 748 patients had their MRI examination validated both at M1 and M24 during the study. At baseline, the volume of hypointense and hyperintense lesions on FLAIR images, the total brain volume, the hippocampal volume and the number of patients with microbleeds did not differ between the two groups. During follow-up, the mean volumetric increase of lesions hypointense or hyperintense on FLAIR images (from 5 to 8 %), the mean reduction of total brain volume (−0.4 %) and of hippocampal volume (−4 %), did not differ between the two treatment arms. The same parameters analysed ipsilateral to the ischaemic lesion did not differ either between the two groups. In the terutroban group, 16.3 % of patients presented with emergent microbleeds, 10.7 % in the aspirin group; this difference was not significant. In the PERFORM study, the progression of FLAIR lesions, of cerebral or hippocampal atrophy and of microbleeds did not differ between patients treated by terutroban and those treated by aspirin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pneumocystis jirovecii pneumonia (PCP) and cytomegalovirus (CMV) infection represent possible complications of medical immunosuppression. Between 2005 and 2010, non-human immunodeficiency virus (HIV) PCP patients admitted to a nephrology unit were analyzed for outcome, CMV comorbidity, and patient-to-patient contacts prior to PCP. In contrast to 2002-2004 (no cases) and 2008-2010 (10 cases), a PCP outbreak of 29 kidney-transplant recipients and one patient with anti-glomerular basement membrane disease occurred between 2005 and 2007. None of the patients were on PCP chemoprophylaxis. In four PCP patients, the genotyping data of bronchoalveolar lavage specimen showed an identical Pneumocystis strain. PCP cases had a higher incidence of CMV infection (12 of 30 PCP patients) and CMV disease (four patients) when compared to matched PCP-free controls (p&#8201;<&#8201;0.05). Cotrimoxazole and, if applicable, ganciclovir were started 2.0&#8201;±&#8201;4.0 days following admission, and immunosuppressive medication was reduced. In-hospital mortality was 10% and the three-year mortality was 20%. CMV co-infection did not affect mortality. CMV co-infection more frequently occurred during a cluster outbreak of non-HIV PCP in comparison to PCP-free controls. Here, CMV awareness and specific therapy of both CMV infection and PCP led to a comparatively favorable patient outcome. The role of patient isolation should be further investigated in incident non-HIV PCP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and MRI are used for detecting liver metastases from uveal melanoma. The introduction of new treatment options in clinical trials might benefit from early response assessment. Here, we determine the value of FDG-PET/CT with respect to MRI at diagnosis and its potential for monitoring therapy. MATERIAL AND METHODS: Ten patients with biopsy-proven liver metastases of uveal melanoma enrolled in a randomized phase III trial (NCT00110123) underwent both FDG-PET coupled with unenhanced CT and gadolinium-diethylene triamine pentaacetic acid-enhanced liver MRI within 4 weeks. FDG-PET and MRI were evaluated blindly and then compared using the ratio of lesion to normal liver parenchyma PET-derived standardized uptake value (SUV). The influence of lesion size and response to chemotherapy were studied. RESULTS: Overall, 108 liver lesions were seen: 34 (31%) on both modalities (1-18 lesions/patient), four (4%) by PET/CT only, and 70 (65%) by MRI only. SUV correlated with MRI lesion size (r=0.81, P&lt;0.0001). PET/CT detected 26 of 33 (79%) MRI lesions of more than or equal to 1.2 cm, whereas it detected only eight of 71 (11%) lesions of less than 1.2 cm (P&lt;0.0001). MRI lesions without PET correspondence were small (0.6±0.2 vs. 2.1±1.1 cm, P&lt;0.0001). During follow-up (six patients, 30 lesions), the ratio lesion-to-normal-liver SUV diminished in size-stable lesions (1.90±0.64-1.46±0.50, P&lt;0.0001), whereas it increased in enlarging lesions (1.56±0.40-1.99±0.56, P=0.032). CONCLUSION: MRI outweighs PET/CT for detecting small liver metastases. However, PET/CT detected at least one liver metastasis per patient and changes in FDG uptake not related to size change, suggesting a role in assessing early therapy response.