409 resultados para internal pressure
Resumo:
OBJECT: Cerebrovascular pressure reactivity is the ability of cerebral vessels to respond to changes in transmural pressure. A cerebrovascular pressure reactivity index (PRx) can be determined as the moving correlation coefficient between mean intracranial pressure (ICP) and mean arterial blood pressure. METHODS: The authors analyzed a database consisting of 398 patients with head injuries who underwent continuous monitoring of cerebrovascular pressure reactivity. In 298 patients, the PRx was compared with a transcranial Doppler ultrasonography assessment of cerebrovascular autoregulation (the mean index [Mx]), in 17 patients with the PET-assessed static rate of autoregulation, and in 22 patients with the cerebral metabolic rate for O(2). Patient outcome was assessed 6 months after injury. RESULTS: There was a positive and significant association between the PRx and Mx (R(2) = 0.36, p < 0.001) and with the static rate of autoregulation (R(2) = 0.31, p = 0.02). A PRx > 0.35 was associated with a high mortality rate (> 50%). The PRx showed significant deterioration in refractory intracranial hypertension, was correlated with outcome, and was able to differentiate patients with good outcome, moderate disability, severe disability, and death. The graph of PRx compared with cerebral perfusion pressure (CPP) indicated a U-shaped curve, suggesting that too low and too high CPP was associated with a disturbance in pressure reactivity. Such an optimal CPP was confirmed in individual cases and a greater difference between current and optimal CPP was associated with worse outcome (for patients who, on average, were treated below optimal CPP [R(2) = 0.53, p < 0.001] and for patients whose mean CPP was above optimal CPP [R(2) = -0.40, p < 0.05]). Following decompressive craniectomy, pressure reactivity initially worsened (median -0.03 [interquartile range -0.13 to 0.06] to 0.14 [interquartile range 0.12-0.22]; p < 0.01) and improved in the later postoperative course. After therapeutic hypothermia, in 17 (70.8%) of 24 patients in whom rewarming exceeded the brain temperature threshold of 37 degrees C, ICP remained stable, but the average PRx increased to 0.32 (p < 0.0001), indicating significant derangement in cerebrovascular reactivity. CONCLUSIONS: The PRx is a secondary index derived from changes in ICP and arterial blood pressure and can be used as a surrogate marker of cerebrovascular impairment. In view of an autoregulation-guided CPP therapy, a continuous determination of a PRx is feasible, but its value has to be evaluated in a prospective controlled trial.
Resumo:
BACKGROUND: A simple prognostic model could help identify patients with pulmonary embolism who are at low risk of death and are candidates for outpatient treatment. METHODS: We randomly allocated 15,531 retrospectively identified inpatients who had a discharge diagnosis of pulmonary embolism from 186 Pennsylvania hospitals to derivation (67%) and internal validation (33%) samples. We derived our rule to predict 30-day mortality using classification tree analysis and patient data routinely available at initial examination as potential predictor variables. We used data from a European prospective study to externally validate the rule among 221 inpatients with pulmonary embolism. We determined mortality and nonfatal adverse medical outcomes across derivation and validation samples. RESULTS: Our final model consisted of 10 patient factors (age > or = 70 years; history of cancer, heart failure, chronic lung disease, chronic renal disease, and cerebrovascular disease; and clinical variables of pulse rate > or = 110 beats/min, systolic blood pressure < 100 mm Hg, altered mental status, and arterial oxygen saturation < 90%). Patients with none of these factors were defined as low risk. The 30-day mortality rates for low-risk patients were 0.6%, 1.5%, and 0% in the derivation, internal validation, and external validation samples, respectively. The rates of nonfatal adverse medical outcomes were less than 1% among low-risk patients across all study samples. CONCLUSIONS: This simple prediction rule accurately identifies patients with pulmonary embolism who are at low risk of short-term mortality and other adverse medical outcomes. Prospective validation of this rule is important before its implementation as a decision aid for outpatient treatment.
Resumo:
OBJECTIVE: To assess the post-ischemic skin blood flow response after withdrawal of antihypertensive therapy in hypertensive patients with normal blood pressure during treatment. DESIGN AND METHODS: Twenty hypertensive patients (group A) with a normal clinic blood pressure (<140/ 90 mmHg) receiving antihypertensive treatment (any monotherapy; one pill per day for at least 6 months) had their treatment discontinued. Before medication withdrawal and 2, 4, 12 and 24 weeks thereafter, the following measurements were made: clinic blood pressure, home blood pressure (three times per week, morning and evening) and skin blood flow response to a 5 min forearm arterial occlusion (using laser Doppler flowmetry). The patients were asked to perform an ambulatory blood pressure recording at any time if home blood pressure was > or =160/95 mmHg on two consecutive days, and treatment was initiated again, after determination of the skin hyperemic response, if daytime ambulatory blood pressure was > or =140/90 mmHg. The same studies were performed in 20 additional hypertensive individuals in whom antihypertensive treatment was not withdrawn (group B). The allocation of patients to groups A and B was random. RESULTS: The data fom 18 patients in group A who adhered strictly to the procedure were available for analysis. Seven of them had to start treatment again within the first 4 weeks of follow-up; four additional patients started treatment again during the next 8 weeks (group A1). The seven other patients remained untreated (group A2). The skin hyperemic response decreased significantly in patients in group A1 and returned to baseline values at the end of the study, when there were again receiving antihypertensive treatment. In patients in group A2 a significant attenuation of the hyperemic response was also observed. This impaired response was present even at the end of the 6 month follow-up, at which time the patients were still untreated but exhibited a significantly greater blood pressure than before drug discontinuation. The hyperemic response of patients who did not stop treatment (group B) did not change during the course of the study. CONCLUSIONS: Our findings show a decrease in the postischemic skin blood flow response after withdrawal of antihypertensive treatment in hypertensive patients. This impaired response may be due to the development of endothelial dysfunction, vascular remodeling, or both, and might contribute to the return of blood pressure to hypertensive values after withdrawal of antihypertensive therapy.
Resumo:
BACKGROUND: Obesity is increasing worldwide because developing countries are adopting Western high-fat foods and sedentary lifestyles. In parallel, in many of them, hypertension is rising more rapidly, particularly with age, than in Western countries. OBJECTIVE: To assess the relationship between adiposity and blood pressure (BP) in a developing country with high average BP (The Seychelles, Indian Ocean, population mainly of African origin) in comparison to a developed country with low average BP (Switzerland, population mainly of Caucasian origin). DESIGN: Cross-sectional health examination surveys based on population random samples. SETTING: The main Seychelles island (Mahé) and two Swiss regions (Vaud-Fribourg and Ticino). SUBJECTS: Three thousand one hundred and sixteen adults (age range 35-64) untreated for hypertension. MEASUREMENTS: Body mass index (BMI), waist circumference (WC), waist-to-hip ratio (WHR), systolic and diastolic blood pressure (SBP and DBP, mean of two measures). METHODS: Scatterplot smoothing techniques and gender-specific linear regression models. RESULTS: On average, SBP and DBP were found to increase linearly over the whole variation range of BMI, WHR and WC. A modest, but statistically significant linear association was found between each indicator of adiposity and BP levels in separate regression models controlling for age. The regression coefficients were not significantly different between the Seychelles and the two Swiss regions, but were generally higher in women than in men. For the latter, a gain of 1.7 kg/m(2) in BMI, of 4.5 cm in WC or of 3.4% in WHR corresponded to an elevation of 1 mmHg in SBP. For women, corresponding figures were 1.25 kg/m(2), 2.5 cm and 1.8% respectively. Regression coefficients for age reflected a higher effect of this variable on both SBP and DBP in the Seychelles than in Switzerland. CONCLUSION: These findings suggest a stable linear relation of adiposity with BP, independent of age and body fat distribution, across developed and developing countries. The more rapid increase of BP with age observed in the latter countries are likely to reflect higher genetic susceptibility and/or higher cumulative exposure to another risk factor than adiposity.
Resumo:
Résumé en français: Il est admis que l'inflation d'une manchette à pression au niveau du bras engendre une augmentation réactionnelle de la tension artérielle qui peut être le résultat d'une gêne lors de l'inflation et peut diminuer la précision de la mesure. Dans cette étude, nous comparons séquentiellement l'augmentation de la tension artérielle lorsque la manchette à pression est positionnée au niveau du bras et au niveau du poignet. Nous avons étudié un collectif de 34 participants normotendus et 34 patients hypertendus. Chacun d'eux était équipé de deux manchettes à pression, l'une au niveau du bras et l'autre au niveau du poignet. Nous avons randomisé l'ordre d'inflation des manchettes ainsi que la pression d'inflation maximale (180mmHg versus 240mmHg). Trois mesures étaient effectuées pour chaque pression d'inflation maximale, ceci au bras comme poignet, et leur séquence était également randomisée. En parallèle, un enregistrement continu de la tension artérielle avait lieu au niveau du majeur de la main opposée à l'aide d'un photoplethysmographe. Cette valeur était considérée comme la valeur de tension artérielle au repos. Pour les participants normotendus, aucune différence statistiquement significative n'a pu être mise en évidence en lien avec la position de la manchette à pression, ceci indépendamment de la pression d'inflation maximale. Variation de la pression systolique à 180 mmHg: 4.3+/-3.0 mmHg au bras et 3.7+/-2.9 mmHg au poignet (p=ns), à 240 mmHg: 5.5+/-3.9 au bras et 4.2+/-2.7 mmHg au poignet (p=0.052). En revanche, concernant les patients hypertendus, une augmentation significative de la tension artérielle a été mise en évidence entre le bras et le poignet. Ceci pour les valeurs de tension artérielle systolique et diastolique et quelle que soit la pression d'inflation maximale utilisée. Augmentation de la pression artérielle systolique 6.513.5 mmHg au bras et 3.812.1mmHg au poignet pour une pression d'inflation maximale de 180 mmHg (p<0.01) et respectivement 6.413.5 mmHg et 4.713.0 mmHg pour 240 mmHg (p=0.01). L'augmentation des valeurs de tension artérielle était indépendante de la valeur tensionnelle de base. Ces résultats montrent que les patients hypertendus réagissent significativement moins à l'inflation d'une manchette ä pression lorsque celle-ci est positionnée au niveau du poignet par rapport au bras, ceci indépendamment des valeurs de tension artérielle de base des patients. Nous pouvons donc suggérer que l'inflation d'une manchette à pression cause moins de désagrément lorsqu'elle est placée au niveau du poignet, notamment chez les patients hypertendus et qu'elle peut être une alternative à la mesure standard au niveau du bras.
Resumo:
OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.
Resumo:
To assess the behavior of the arterial wall in hypertensive patients, we developed a noninvasive ultrasonic device. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to establish compliance-pressure curves. Blood pressure, which is a co-determinant of compliance, is thus taken into account. This method allows one to compare arteries from patients with different blood pressures. Arterial compliance and distensibility were first investigated in healthy young volunteers administered either lisinopril (20 mg), atenolol (100 mg) or nitrendipine (20 mg) once a day. After 8 days of treatment, only lisinopril was found to increase arterial compliance. Subsequently, we compared arterial diameter- and distensibility-pressure curves from newly diagnosed and untreated hypertensive patients with those of matched normotensive control patients. Diameter-pressure curves did not differ significantly between the groups and distensibility was not reduced. Similar findings were later obtained in an animal model, when mechanical properties of carotid arteries were compared between spontaneously hypertensive rats and normotensive counterparts (Wistar-Kyoto rats). These results, although interesting by providing noninvasive information on the elastic response of the wall, call for further development of the technique to be able to measure arterial wall thickness. Stress-strain relationship could ultimately be established to thoroughly characterize physical properties of blood vessel walls.