92 resultados para central venous pressure


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Venous cannula orifice obstruction is an underestimated problem during augmented cardiopulmonary bypass (CPB), which can potentially be reduced with redesigned, virtually wall-less cannula designs versus traditional percutaneous control venous cannulas. A bench model, allowing for simulation of the vena cava with various affluent orifices, venous collapse and a worst case scenario with regard to cannula position, was developed. Flow (Q) was measured sequentially for right atrial + hepatic + renal + iliac drainage scenarios, using a centrifugal pump and an experimental bench set-up (afterload 60 mmHg). At 1500, 2000 and 2500 RPM and atrial position, the Q values were 3.4, 6.03 and 8.01 versus 0.77*, 0.43* and 0.58* l/min: p<0.05* for wall-less and the Biomedicus(®) cannula, respectively. The corresponding pressure values were -15.18, -31.62 and -74.53 versus -46.0*, -119.94* and -228.13* mmHg. At the hepatic position, the Q values were 3.34, 6.67 and 9.26 versus 2.3*, 0.42* and 0.18* l/min; and the pressure values were -10.32, -20.25 and -42.83 versus -23.35*, -119.09* and -239.38* mmHg. At the renal position, the Q values were 3.43, 6.56 and 8.64 versus 2.48*, 0.41* and 0.22* l/min and the pressure values were -9.64, -20.98 and -63.41 versus -20.87 -127.68* and -239* mmHg, respectively. At the iliac position, the Q values were 3.43, 6.01 and 9.25 versus 1.62*, 0.55* and 0.58* l/min; the pressure values were -9.36, -33.57 and -44.18 versus -30.6*, -120.27* and -228* mmHg, respectivly. Our experimental evaluation demonstrates that the redesigned, virtually wall-less cannulas, allowing for direct venous drainage at practically all intra-venous orifices, outperform the commercially available control cannula, with superior flow at reduced suction levels for all scenarios tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To evaluate the effectiveness and safety of Posterior Sub-Tenon (PST) Triamcinolone Acetonide (TA) injection for persistent macular oedema associated with non-ischemic Central Retinal Vein Occlusion (CRVO) or Branch Retinal Vein Occlusion (BRVO) in non-vitrectomized eye. Methods: Fourteen consecutive eyes of 14 patients characterized by macular oedema lasting more than 3 months and with a visual acuity of less than 20/40 were enrolled. Six eyes presented with BRVO, 8 eyes with CRVO. PST injection of 40 mg TA was performed in topical anaesthesia. All patients were phakic, and followed for at least 6 months. Snellen visual acuity converted to LogMAR units and anatomic responses were evaluated before, and at 1, 3, 6, and 12 (if required) months after injections and re-injection considered. Results: In the BRVO group, mean foveal thickness was 548.2±49.50 μm preoperatively, and 452.8±56.2 μm and 280.8±62.5 μm at 1 and 12 month follow-up, respectively. Statistical analysis showed significant differences between preoperative and postoperative measurements (P<.05, paired t test) 3 months after injections. Improvement of visual acuity by at least 0.2 LogMAR was seen in 3(50%) of the 6 eyes. No re-injection was needed. In the CRVO group, mean foveal thickness was 543.7±34.4 μm preoperatively, and 283.0±29.0 μm and 234.8±23.6 μm at 1 and 12 month follow-up, respectively. Statistical analysis showed significant differences between preoperative and postoperative measurements (P<.05, paired t test). Improvement of visual acuity by at least 0.2 LogMAR was seen in 7 eyes (88%). Mean number of re-injection was of 2.1±0.3. Intraocular pressure elevation of 22 mm Hg or higher was found in 2/14 eyes (14%). Cataract progression was noted in 5/14 eyes (36%). Conclusions: PST injection of TA appears to be as safe and effective treatment for chronic macular oedema associated due to both non-ischemic BRVO or CRVO, with a better efficacy in BRVO.