270 resultados para autogenous bone graft


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we present a processing route to produce multi-structured ceramic foams based on the combination of particle-stabilized foams with polymeric sponges to produce positive and negative templating structures. Polyester sponges are infiltrated with freshly produced calcium aluminate alumina foams and upon sintering either positive templating structures are produced when wetting the sponges, or negative templating foams with a percolating pore network are obtained when completely filling the sponges. Additionally, by combining different layers of these particle-stabilized foam infiltrated sponges, various different structures can be produced, including sandwich structures, pore size gradients, and ceramic bone-like structures applying to different types of bone. The particle-stabilized foams used were in situ self-hardening calcium aluminate cement enriched alumina foams to obtain crack-free samples with pore interconnections and tailorable pore sizes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart transplantation is the treatment of choice for many patients with end-stage heart failure. Its success, however, is limited by organ shortage, side effects of immunosuppressive drugs, and chronic rejection. Gene therapy is conceptually appealing for applications in transplantation, as the donor organ is genetically manipulated ex vivo before transplantation. Localised expression of immunomodulatory genes aims to create a state of immune privilege within the graft, which could eliminate the need for systemic immunosuppression. In this review, recent advances in the development of gene therapy in heart transplantation are discussed. Studies in animal models have demonstrated that genetic modification of the donor heart with immunomodulatory genes attenuates ischaemia-reperfusion injury and rejection. Alternatively, bone marrow-derived cells genetically engineered with donor-type major histocompatibility complex (MHC) class I or II promote donor-specific hyporesponsiveness. Genetic engineering of naïve T cells or dendritic cells may induce regulatory T cells and regulatory dendritic cells. Despite encouraging results in animal models, however, clinical gene therapy trials in heart transplantation have not yet been started. The best vector and gene to be delivered remain to be identified. Pre-clinical studies in non-human primates are needed. Nonetheless, the potential of gene therapy as an adjunct therapy in transplantation is essentially intact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline whole-blood values due to processing and concentration. PRP is used in various surgical fields to enhance soft-tissue and bone healing by delivering supra-physiological concentrations of autologous platelets at the site of tissue damage. These preparations may provide a good cellular source of various growth factors and cytokines, and modulate tissue response to injury. Common clinically available materials for blood preparations combined with a two-step centrifugation protocol at 280g each, to ensure cellular component integrity, provided platelet preparations which were concentrated 2-3 fold over total blood values. Costs were shown to be lower than those of other methods which require specific equipment and high-cost disposables, while safety and traceability can be increased. PRP can be used for the treatment of wounds of all types including burns and also of split-thickness skin graft donor sites, which are frequently used in burn management. The procedure can be standardized and is easy to adapt in clinical settings with minimal infrastructure, thus enabling large numbers of patients to benefit from a form of cellular therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several cross-sectional studies have shown the ability of the TBS to discriminate between those with and without fractures in European populations. The aim of this study was to assess the ability of TBS to discriminate between those with and without fractures in a large female Caucasian population in the USA. This was a case-control study of 2,165 Caucasian American women aged 40 and older. Patients with illness or taking medications known to affect bone metabolism were excluded. Those in the fracture group (n = 289) had at least one low-energy fracture. BMD was measured at L1-L4, TBS calculated directly from the same DXA image. Descriptive statistics and inferential tests for difference were used. Univariate and multivariate logistic regression models were created to investigate possible association between independent variables and the status of fracture. Odds ratios per standard deviation decrease (OR) and areas under the ROC curve were calculated for discriminating parameters. Weak correlations were observed between TBS and BMD and between TBS and BMI (r = 0.33 and -0.17, respectively, p < 0.01). Mean age, weight, BMD and TBS were significantly different between control and fracture groups (all p ≤ 0.05), whereas no difference was noted for BMI or height. After adjusting for age, weight, BMD, smoking, and maternal and family history of fracture, TBS (but not BMD) remained a significant predictor of fracture: OR 1.28[1.13-1.46] even after adjustment. In a US female population, TBS again was able to discriminate between those with and those without fractures, even after adjusting for other clinical risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone ultrasound measures (QUSs) can assess fracture risk in the elderly. We compared three QUSs and their association with nonvertebral fracture history in 7562 Swiss women 70-80 years of age. The association between nonvertebral fracture was higher for heel than phalangeal QUS. INTRODUCTION: Because of the high morbidity and mortality associated with osteoporotic fractures, it is essential to detect subjects at risk for such fractures with screening methods. Because quantitative bone ultrasound (QUS) discriminated subjects with osteoporotic fractures from controls in several cross-sectional studies and predicted fractures in prospective studies, QUS could be more practical than DXA for screening. MATERIAL AND METHODS: This cross-sectional and retrospective multicenter (10 centers) study was performed to compare three QUSs (two heel ultrasounds: Achilles+ [GE-Lunar] and Sahara [Hologic]; the phalanges: ultrasound DBM sonic 1200 [IGEA]) for determining by logistic regression nonvertebral fracture odds ratio (OR) in a sample of 7562 Swiss women, 75.3 +/- 3.1 years of age. The two heel QUSs measured the broadband ultrasound attenuation (BUA) and the speed of sound (SOS). In addition, Achilles+ calculated the stiffness index (SI) and the Sahara calculated the quantitative ultrasound index (QUI) from BUA and SOS. The DBM sonic 1200 measured the amplitude-dependent SOS (AD-SOS). RESULTS: Eighty-six women had a history of a traumatic hip fracture after the age of 50, 1594 had a history of forearm fracture, and 2016 had other nonvertebral fractures. No fracture history was reported by 3866 women. Discrimination for hip fracture was higher than for the other nonvertebral fractures. The two heel QUSs had a significantly higher discrimination power than the QUSs of the phalanges, with standardized ORs, adjusted for age and body mass index, ranging from 2.1 to 2.7 (95% CI = 1.6, 3.5) compared with 1.4 (95% CI = 1.1, 1.7) for the AD-SOS of DBM sonic 1200. CONCLUSION: This study showed a high association between heel QUS and hip fracture history in elderly Swiss women. This could justify integration of QUS among screening strategies for identifying elderly women at risk for osteoporotic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The beneficial effect of physical exercise on bone mineral density (BMD) is at least partly explained by the forces exerted directly on the bones. Male runners present generally higher BMD than sedentary individuals. We postulated that the proximal tibia BMD is related to the running distance as well as to the magnitude of the shocks (while running) in male runners. Methods: A prospective study (three yearly measurements) included 81 healthy male subjects: 16 sedentary lean subjects and three groups of runners (5-30 km/week, n=19; 30-50 km/week, n=29; 50-100 km/week, n=17). Several measurements were performed at the proximal tibia level: volumetric BMD (vBMD), cortical index (CI) i.e. an index of cortical bone thickness and peak accelerations (an index of shocks during heel strike) while running (measured by a 3-D accelerometer). A general linear model assessed the prediction of vBMD or CI by a) simple effects (running distance, peak accelerations, time) and b) interactions (for instance if vBMD prediction by peak acceleration depends on running distance). Results: CI and vBMD a) increase with running distance to reach a plateau over 30 km/wk, b) are positively associated with peak accelerations over 30 km/week. Discussion: Running may be associated with high peak accelerations in order to have beneficial effects on BMD. More important strains are needed to be associated with the same increase in BMD during running sessions of short duration than those of long duration. Conclusion: CI and vBMD are associated with the magnitude of the shocks during heel strike in runners. Key words: Bone mineral density, strains, physical exercise, running distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of bone mineral density (BMD) for fracture discrimination may be improved by considering bone microarchitecture. Texture parameters such as trabecular bone score (TBS) or mean Hurst parameter (H) could help to find women who are at high risk of fracture in the non-osteoporotic group. The purpose of this study was to combine BMD and microarchitectural texture parameters (spine TBS and calcaneus H) for the detection of osteoporotic fractures. Two hundred and fifty five women had a lumbar spine (LS), total hip (TH), and femoral neck (FN) DXA. Additionally, texture analyses were performed with TBS on spine DXA and with H on calcaneus radiographs. Seventy-nine women had prevalent fragility fractures. The association with fracture was evaluated by multivariate logistic regressions. The diagnostic value of each parameter alone and together was evaluated by odds ratios (OR). The area under curve (AUC) of the receiver operating characteristics (ROC) were assessed in models including BMD, H, and TBS. Women were also classified above and under the lowest tertile of H or TBS according to their BMD status. Women with prevalent fracture were older and had lower TBS, H, LS-BMD, and TH-BMD than women without fracture. Age-adjusted ORs were 1.66, 1.70, and 1.93 for LS, FN, and TH-BMD, respectively. Both TBS and H remained significantly associated with fracture after adjustment for age and TH-BMD: OR 2.07 [1.43; 3.05] and 1.47 [1.04; 2.11], respectively. The addition of texture parameters in the multivariate models didn't show a significant improvement of the ROC-AUC. However, women with normal or osteopenic BMD in the lowest range of TBS or H had significantly more fractures than women above the TBS or the H threshold. We have shown the potential interest of texture parameters such as TBS and H in addition to BMD to discriminate patients with or without osteoporotic fractures. However, their clinical added values should be evaluated relative to other risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: In a head-to-head study, we compared the effects of strontium ranelate (SrRan) and alendronate (ALN), anti-osteoporotic agents with antifracture efficacy, on bone microstructure, a component of bone quality, hence of bone strength. Methods: In a randomised, double-dummy, double-blind controlled trial, 88 postmenopausal osteoporotic women were randomised to SrRan 2g/day or ALN 70mg/week for 2 years. Microstructure of the distal radius and distal tibia were assessed by HR-pQCT after 3,6,12,18 and 24 months of treatment. Primary endpoint was HR-pQCT variables relative changes from baseline. An ITT analysis was applied. Results: Baseline characteristics were similar in both groups (mean ±SD): age: 63.6±7.5 vs. 63.7±7.6 yrs; L1-L4T Score: -2.7±0.8 vs. -2.8±0.8g/cm², Cortical Thickness (CTh), trabecular bone fraction (BV/TV) and cortical density=721±242 vs. 753±263μm, 9.5±2.5 vs. 9.3±2.7%, and 750±87 vs. 745±78mg/cm3 respectively. Over 2 yrs, distal radius values changes were within 1 to 2% without significant differences except cortical density. In contrast distal tibia CTh, BV/TV, trabecular and cortical densities increased significantly more in the SrRan group than in the ALN group (Table). No significant between-group differences were observed for the remaining measured parameter (trabecular number, trabecular spacing, and trabecular thickness). After 2 years, L1- L4 and hip aBMD increases were similar to results from pivotal trials (L1-L4:+6.5% and +5.6%;total hip:+4.1% and +2.9%, in Sr- Ran and ALN groups, respectively). In the SrRan group, bALP increased by a median of 18% (p<0.001) and sCTX decreased by a median of -16% (p=0.005) while in the ALN group, bALP and CTX decreased by median of -31% (p<0.001) and -59% (p<0.001) respectively. Relative changes from baseline to last observation (%) SrRan ALN Estimated between group difference p value CTh (μm) 6.29±9.53 0.93±6.23 5.411±1.836 0.004 BV/TV (%) 2.48±5.13 0.84±3.81 1.783±0.852 0.040 Trabecular density (mgHA/cm3) 2.47±5.07 0.88±4.00 1.729±0.859 0.048 Cortical density (mgHA/cm3) 1.43±2.77 0.36±2.14 1.137±0.530 0.045 The two treatments were well tolerated. Conclusions: Within the constraints related to HRpQCT technology, it appears that strontium ranelate has greater effects than alendronate on distal tibia cortical thickness, trabecular and cortical bone densities in women with postmenopausal osteoporosis after two years of treatment. A concomitant significant increase in bone formation marker is observed in the SrRan group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to evaluate the clinical and subjective outcomes after arthroscopic-assisted double-bundle posterior cruciate ligament (PCL) reconstruction. METHODS: A series of 15 patients with grade III isolated chronic PCL tears underwent double-bundle PCL reconstruction. Of these patients, 8 (53%) had simultaneous fractures. The mean time from accident to surgery was 10.8 months (range, 8 to 15 months). The mean age at the time of surgery was 28.2 years (range, 17 to 43 years). All of the patients reported knee insecurity during activities of daily living or light sporting activities, with associated anterior knee pain in 5 patients. Preoperatively, posterolateral or posteromedial corner injuries were ruled out through accurate clinical examination. The knees were assessed before surgery and at a mean follow-up of 3.2 years (range, 2 to 5 years) with a physical examination, 4 different rating scales, and stress radiographs obtained with a Telos device (Telos, Marburg, Germany). RESULTS: Postoperative physical examination revealed a reduction of the posterior drawer and tibial step-off in all cases, although the posterior laxity was not completely normalized. Nevertheless, the patients were subjectively better after surgery. The subjective International Knee Documentation Committee score was significantly ameliorated. With regard to the objective International Knee Documentation Committee score, 6 knees (40%) were graded as abnormal because of posterior displacement of 6 mm or greater on follow-up stress radiographs with the Telos device. On the Lysholm knee scoring scale, the score was excellent in 13% of patients and good in 87%. The mean score on the Hospital for Special Surgery knee ligament rating scale was 85.8. The Tegner activity score showed an amelioration after surgery, but no patient resumed his or her preinjury level of activities. The postoperative stress radiographs revealed an improvement in posterior instability of 50% or more in all but 3 knees (20%). CONCLUSIONS: Our technique of double-bundle PCL reconstruction produced a significant reduction in knee symptoms and allowed the patients to return to moderate or strenuous activity, although the posterior tibial translation was not completely normalized and our results appear to be no better than the results of single-bundle PCL reconstruction. LEVEL OF EVIDENCE: Level IV, therapeutic case series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate the risk factors associated with Contegra graft (Medtronic Minneapolis, MN, USA) infection after reconstruction of the right ventricular outflow tract. METHODS: One hundred and six Contegra grafts were implanted between April 1999 and April 2010 for the Ross procedure (n = 46), isolated pulmonary valve replacement (n = 32), tetralogy of Fallot (n = 24), double-outlet right ventricle (n = 7), troncus arteriosus (n = 4), switch operation (n = 1) and redo of pulmonary valve replacement (n = 2). The median age of the patients was 13 years (range 0-54 years). A follow-up was completed in all cases with a median duration of 7.6 years (range 1.7-12.7 years). RESULTS: There were 3 cases of in-hospital mortality. The survival rate during 7 years was 95.7%. Despite the lifelong endocarditis prophylaxis, Contegra graft infection was diagnosed in 12 (11.3%) patients at a median time of 4.4 years (ranging from 0.4 to 8.7 years). Univariate analysis of preoperative, perioperative and postoperative variables was performed and the following risk factors for time to infection were identified: female gender with a hazard ratio (HR) of 0.19 (P = 0.042), systemic-to-pulmonary shunt (HR 6.46, P < 0.01), hypothermia (HR 0.79, P = 0.014), postoperative renal insufficiency (HR 11.97, P = 0.015) and implantation of permanent pacemaker during hospitalization (HR 5.29, P = 0.075). In 2 cases, conservative therapy was successful and, in 10 patients, replacement of the infected valve was performed. The Contegra graft was replaced by a homograft in 2 cases and by a new Contegra graft in 8 cases. Cox's proportional hazard model indicated that time to graft infection was significantly associated with tetralogy of Fallot (HR 0.06, P = 0.01), systemic-to-pulmonary shunt (HR 64.71, P < 0.01) and hypothermia (HR 0.77, P < 0.01). CONCLUSION: Contegra graft infection affected 11.3% of cases in our cohort, and thus may be considered as a frequent entity that can be predicted by both intraoperative and early postoperative factors. After the diagnosis of infection associated with the Contegra graft was confirmed, surgical treatment was the therapy of choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural basis of the antifracture efficacy of strontium ranelate and alendronate is incompletely understood. We compared the effects of strontium ranelate and alendronate on distal tibia microstructure over 2 years using HR-pQCT. In this pre-planned, interim, intention-to-treat analysis at 12 months, 88 osteoporotic postmenopausal women (mean age 63.7 +/- 7.4) were randomized to strontium ranelate 2 g/day or alendronate 70 mg/week in a double-placebo design. Primary endpoints were changes in microstructure. Secondary endpoints included lumbar and hip areal bone mineral density (aBMD), and bone turnover markers. This trial is registered with http://www.controlled-trials.com, number ISRCTN82719233. Baseline characteristics of the two groups were similar. Treatment with strontium ranelate was associated with increases in mean cortical thickness (CTh, 5.3%), cortical area (4.9%) and trabecular density (2.1%) (all P < 0.001, except cortical area P = 0.013). No significant changes were observed with alendronate. Between-group differences in favor of strontium ranelate were observed for CTh, cortical area, BV/TV and trabecular density (P = 0.045, 0.041, 0.048 and 0.035, respectively). aBMD increased to a similar extent with strontium ranelate and alendronate at the spine (5.7% versus 5.1%, respectively) and total hip (3.3% versus 2.2%, respectively). No significant changes were observed in remodeling markers with strontium ranelate, while suppression was observed with alendronate. Within the methodological constraints of HR-pQCT through its possible sensitivity to X-ray attenuation of different minerals, strontium ranelate had greater effects than alendronate on distal tibia cortical thickness and trabecular volumetric density.