208 resultados para TREATMENT SUCCESS RATE


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The increase of apparent diffusion coefficient (ADC) in treated hepatic malignancies compared to pre-therapeutic values has been interpreted as treatment success; however, the variability of ADC measurements remains unknown. Furthermore, ADC has been usually measured in the whole lesion, while measurements should be probably centered on the area with the most restricted diffusion (MRDA) as it represents potential tumoral residue. Our objective was to compare the inter/intraobserver variability of ADC measurements in the whole lesion and in MRDA. Material and methods: Forty patients previously treated with chemoembolization or radiofrequency were evaluated (20 on 1.5T and 20 on 3.0T). After consensual agreement on the best ADC image, two readers measured the ADC values using separate regions of interest that included the whole lesion and the whole MRDA without exceeding their borders. The same measurements were repeated two weeks later. Spearman test and the Bland-Altman method were used. Results: Interobserver correlation in ADC measurements in the whole lesion and MRDA was as follows: 0.962 and 0.884. Intraobserver correlation was, respectively, 0.992 and 0.979. Interobserver limits of variability (mm2/sec*10-3) were between -0.25/+0.28 in the whole lesion and between -0.51/+0.46 in MRDA. Intraobserver limits of variability were, respectively: -0.25/+0.24 and -0.43/+0.47. Conclusion: We observed a good inter/intraobserver correlation in ADC measurements. Nevertheless, a limited variability does exist, and it should be considered when interpreting ADC values of hepatic malignancies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims: To analyze the current literature on combined endoscopic-laparoscopic resection of colon polyps and to compare this new approach to standard laparoscopic colonic resection for polyps not suitable for endoscopic resection. Results: Several studies demonstrated that with a combined endoscopic-laparoscopic approach, polyps were successfully resected in 82-91% with a low morbidity of 3-10% and a short hospital stay of 1-2 days. Segmental laparoscopic resection was necessary in only 9-12%, but had a conversion rate to open surgery of 15% with an average hospital stay of 6-11 days. A cancerous polyp was found in 6-13% after a combined approach, with lymph node metastasis in 6%. Recurrent polyps after a combined endoscopic-laparoscopic resection seem to be rare, but follow-up of most studies is short and incomplete. Conclusion: Combined endoscopic-laparoscopic resection of colon polyps is feasible, safe, and has a high success rate. Malignant lesions can be treated laparoscopically during the same operation, avoiding the need for a second procedure, and with good long-term oncologic outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Video-laryngoscopes are marketed for intubation in difficult airway management. They provide a better view of the larynx and may facilitate tracheal intubation, but there is no adequately powered study comparing different types of video-laryngoscopes in a difficult airway scenario or in a simulated difficult airway situation. METHODS/DESIGN: The objective of this trial is to evaluate and to compare the clinical performance of three video-laryngoscopes with a guiding channel for intubation (Airtraq?, A. P. Advance?, King Vision?) and three video-laryngoscopes without an integrated tracheal tube guidance (C-MAC?, GlideScope?, McGrath?) in a simulated difficult airway situation in surgical patients. The working hypothesis is that each video-laryngoscope provides at least a 90% first intubation success rate (lower limit of the 95% confidence interval >0.9). It is a prospective, patient-blinded, multicenter, randomized controlled trial in 720 patients who are scheduled for elective surgery under general anesthesia, requiring tracheal intubation at one of the three participating hospitals. A difficult airway will be created using an extrication collar and taping the patients' head on the operating table to substantially reduce mouth opening and to minimize neck movement. Tracheal intubation will be performed with the help of one of the six devices according to randomization. Insertion success, time necessary for intubation, Cormack-Lehane grade and percentage of glottic opening (POGO) score at laryngoscopy, optimization maneuvers required to aid tracheal intubation, adverse events and technical problems will be recorded. Primary outcome is intubation success at first attempt. DISCUSSION: We will simulate the difficult airway and evaluate different video-laryngoscopes in this highly realistic and clinically challenging scenario, independently from manufacturers of the devices. Because of the sufficiently powered multicenter design this study will deliver important and cutting-edge results that will help clinicians decide which device to use for intubation of the expected and unexpected difficult airway. TRIAL REGISTRATION: NCT01692535.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A recent phase 1 trial has demonstrated that the generation of tumor-reactive T lymphocytes by transfer of specific T-cell receptor (TCR) genes into autologous lymphocytes is feasible. However, compared with results obtained by infusion of tumor-infiltrating lymphocytes, the response rate observed in this first TCR gene therapy trial is low. One strategy that is likely to enhance the success rate of TCR gene therapy is the use of tumor-reactive TCRs with a higher capacity for tumor cell recognition. We therefore sought to develop standardized procedures for the selection of well-expressed, high-affinity, and safe human TCRs. Here we show that TCR surface expression can be improved by modification of TCR alpha and beta sequences and that such improvement has a marked effect on the in vivo function of TCR gene-modified T cells. From a panel of human, melanoma-reactive TCRs we subsequently selected the TCR with the highest affinity. Furthermore, a generally applicable assay was used to assess the lack of alloreactivity of this TCR against a large series of common human leukocyte antigen alleles. The procedures described in this study should be of general value for the selection of well- and stably expressed, high-affinity, and safe human TCRs for subsequent clinical testing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

3 Summary 3. 1 English The pharmaceutical industry has been facing several challenges during the last years, and the optimization of their drug discovery pipeline is believed to be the only viable solution. High-throughput techniques do participate actively to this optimization, especially when complemented by computational approaches aiming at rationalizing the enormous amount of information that they can produce. In siiico techniques, such as virtual screening or rational drug design, are now routinely used to guide drug discovery. Both heavily rely on the prediction of the molecular interaction (docking) occurring between drug-like molecules and a therapeutically relevant target. Several softwares are available to this end, but despite the very promising picture drawn in most benchmarks, they still hold several hidden weaknesses. As pointed out in several recent reviews, the docking problem is far from being solved, and there is now a need for methods able to identify binding modes with a high accuracy, which is essential to reliably compute the binding free energy of the ligand. This quantity is directly linked to its affinity and can be related to its biological activity. Accurate docking algorithms are thus critical for both the discovery and the rational optimization of new drugs. In this thesis, a new docking software aiming at this goal is presented, EADock. It uses a hybrid evolutionary algorithm with two fitness functions, in combination with a sophisticated management of the diversity. EADock is interfaced with .the CHARMM package for energy calculations and coordinate handling. A validation was carried out on 37 crystallized protein-ligand complexes featuring 11 different proteins. The search space was defined as a sphere of 15 R around the center of mass of the ligand position in the crystal structure, and conversely to other benchmarks, our algorithms was fed with optimized ligand positions up to 10 A root mean square deviation 2MSD) from the crystal structure. This validation illustrates the efficiency of our sampling heuristic, as correct binding modes, defined by a RMSD to the crystal structure lower than 2 A, were identified and ranked first for 68% of the complexes. The success rate increases to 78% when considering the five best-ranked clusters, and 92% when all clusters present in the last generation are taken into account. Most failures in this benchmark could be explained by the presence of crystal contacts in the experimental structure. EADock has been used to understand molecular interactions involved in the regulation of the Na,K ATPase, and in the activation of the nuclear hormone peroxisome proliferatoractivated receptors a (PPARa). It also helped to understand the action of common pollutants (phthalates) on PPARy, and the impact of biotransformations of the anticancer drug Imatinib (Gleevec®) on its binding mode to the Bcr-Abl tyrosine kinase. Finally, a fragment-based rational drug design approach using EADock was developed, and led to the successful design of new peptidic ligands for the a5ß1 integrin, and for the human PPARa. In both cases, the designed peptides presented activities comparable to that of well-established ligands such as the anticancer drug Cilengitide and Wy14,643, respectively. 3.2 French Les récentes difficultés de l'industrie pharmaceutique ne semblent pouvoir se résoudre que par l'optimisation de leur processus de développement de médicaments. Cette dernière implique de plus en plus. de techniques dites "haut-débit", particulièrement efficaces lorsqu'elles sont couplées aux outils informatiques permettant de gérer la masse de données produite. Désormais, les approches in silico telles que le criblage virtuel ou la conception rationnelle de nouvelles molécules sont utilisées couramment. Toutes deux reposent sur la capacité à prédire les détails de l'interaction moléculaire entre une molécule ressemblant à un principe actif (PA) et une protéine cible ayant un intérêt thérapeutique. Les comparatifs de logiciels s'attaquant à cette prédiction sont flatteurs, mais plusieurs problèmes subsistent. La littérature récente tend à remettre en cause leur fiabilité, affirmant l'émergence .d'un besoin pour des approches plus précises du mode d'interaction. Cette précision est essentielle au calcul de l'énergie libre de liaison, qui est directement liée à l'affinité du PA potentiel pour la protéine cible, et indirectement liée à son activité biologique. Une prédiction précise est d'une importance toute particulière pour la découverte et l'optimisation de nouvelles molécules actives. Cette thèse présente un nouveau logiciel, EADock, mettant en avant une telle précision. Cet algorithme évolutionnaire hybride utilise deux pressions de sélections, combinées à une gestion de la diversité sophistiquée. EADock repose sur CHARMM pour les calculs d'énergie et la gestion des coordonnées atomiques. Sa validation a été effectuée sur 37 complexes protéine-ligand cristallisés, incluant 11 protéines différentes. L'espace de recherche a été étendu à une sphère de 151 de rayon autour du centre de masse du ligand cristallisé, et contrairement aux comparatifs habituels, l'algorithme est parti de solutions optimisées présentant un RMSD jusqu'à 10 R par rapport à la structure cristalline. Cette validation a permis de mettre en évidence l'efficacité de notre heuristique de recherche car des modes d'interactions présentant un RMSD inférieur à 2 R par rapport à la structure cristalline ont été classés premier pour 68% des complexes. Lorsque les cinq meilleures solutions sont prises en compte, le taux de succès grimpe à 78%, et 92% lorsque la totalité de la dernière génération est prise en compte. La plupart des erreurs de prédiction sont imputables à la présence de contacts cristallins. Depuis, EADock a été utilisé pour comprendre les mécanismes moléculaires impliqués dans la régulation de la Na,K ATPase et dans l'activation du peroxisome proliferatoractivated receptor a (PPARa). Il a également permis de décrire l'interaction de polluants couramment rencontrés sur PPARy, ainsi que l'influence de la métabolisation de l'Imatinib (PA anticancéreux) sur la fixation à la kinase Bcr-Abl. Une approche basée sur la prédiction des interactions de fragments moléculaires avec protéine cible est également proposée. Elle a permis la découverte de nouveaux ligands peptidiques de PPARa et de l'intégrine a5ß1. Dans les deux cas, l'activité de ces nouveaux peptides est comparable à celles de ligands bien établis, comme le Wy14,643 pour le premier, et le Cilengitide (PA anticancéreux) pour la seconde.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although prosthetic joint infection (PJI) is a rare event after arthroplasty, it represents a significant complication that is associated with high morbidity, need for complex treatment, and substantial healthcare costs. An accurate and rapid diagnosis of PJI is crucial for treatment success. Current diagnostic methods in PJI are insufficient with 10-30% false-negative cultures. Consequently, there is a need for research and development into new methods aimed at improving diagnostic accuracy and speed of detection. In this article, we review available conventional diagnostic methods for the diagnosis of PJI (laboratory markers, histopathology, synovial fluid and periprosthetic tissue cultures), new diagnostic methods (sonication of implants, specific and multiplex PCR, mass spectrometry) and innovative techniques under development (new laboratory markers, microcalorimetry, electrical method, reverse transcription [RT]-PCR, fluorescence in situ hybridization [FISH], biofilm microscopy, microarray identification, and serological tests). The results of highly sensitive diagnostic techniques with unknown specificity should be interpreted with caution. The organism identified by a new method may represent a real pathogen that was unrecognized by conventional diagnostic methods or contamination during specimen sampling, transportation, or processing. For accurate interpretation, additional studies are needed, which would evaluate the long-term outcome (usually >2 years) with or without antimicrobial treatment. It is expected that new rapid, accurate, and fully automatic diagnostic tests will be developed soon.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: More than five hundred million direct dental restorations are placed each year worldwide. In about 55% of the cases, resin composites or compomers are used, and in 45% amalgam. The longevity of posterior resin restorations is well documented. However, data on resin composites that are placed without enamel/dentin conditioning and resin composites placed with self-etching adhesive systems are missing. Material and Methods: The database SCOPUS was searched for clinical trials on posterior resin composites without restricting the search to the year of publication. The inclusion criteria were: (1) prospective clinical trial with at least 2 years of observation; (2) minimum number of restorations at last recall = 20; (3) report on dropout rate; (4) report of operative technique and materials used; (5) utilization of Ryge or modified Ryge evaluation criteria. For amalgam, only those studies were included that directly compared composite resin restorations with amalgam. For the statistical analysis, a linear mixed model was used with random effects to account for the heterogeneity between the studies. P-values under 0.05 were considered significant. Results: Of the 373 clinical trials, 59 studies met the inclusion criteria. In 70% of the studies, Class II and Class I restorations had been placed. The overall success rate of composite resin restorations was about 90% after 10 years, which was not different from that of amalgam. Restorations with compomers had a significantly lower longevity. The main reason for replacement were bulk fractures and caries adjacent to restorations. Both of these incidents were infrequent in most studies and accounted only for about 6% of all replaced restorations after 10 years. Restorations with macrofilled composites and compomer suffered significantly more loss of anatomical form than restorations with other types of material. Restorations that were placed without enamel acid etching and a dentin bonding agent showed significantly more marginal staining and detectable margins compared to those restorations placed using the enamel-etch or etch-and-rinse technique; restorations with self-etching systems were between the other groups. Restorations with compomer suffered significantly more chippings (repairable fracture) than restorations with other materials, which did not statistically differ among each other. Restorations that were placed with a rubber-dam showed significantly fewer material fractures that needed replacement, and this also had a significant effect on the overall longevity. Conclusion: Restorations with hybrid and microfilled composites that were placed with the enamel-etching technique and rubber-dam showed the best overall performance; the longevity of these restorations was similar to amalgam restorations. Compomer restorations, restorations placed with macrofilled composites, and resin restorations with no-etching or self-etching adhesives demonstrated significant shortcomings and shorter longevity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). SETTING: Glaucoma Unit, Department of Ophthalmology, Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland. METHODS: This nonrandomized prospective trial comprised 105 eyes of 105 patients with medically uncontrolled primary and secondary open-angle glaucoma. Visual acuity, intraocular pressure (IOP), and slitlamp examinations were performed before surgery and after surgery at 1 and 7 days, and 1, 3, 6, 9, 12, 18, 24, 30, 36, 48, 54, 60, 66, 72, 78, 84, 90, and 96 months. Visual field examinations were repeated every 6 months. RESULTS: Mean follow-up period was 64 months +/- 26.6 (SD). Mean preoperative IOP was 26.8 +/- 7.7 mm Hg, and mean postoperative IOP was 5.2 +/- 3.35 mm Hg at day 1 and 12 +/- 3 mm Hg at month 78. At 96 months, the qualified success rate (ie, patients who achieved IOP <21 mm Hg with and without medication) was 91%, and the complete success rate (ie, IOP <21 mm Hg without medication) was 57%. At 96 months, 34% of patients had an IOP <21 mm Hg with medication. Fifty-one patients (49%) achieved an IOP < or =15 mm Hg without medication. Neodymium:YAG goniopuncture was performed in 54 patients (51%); mean time of goniopuncture performance was 21 months, and mean IOP before goniopuncture was 20 mm Hg, dropping to 11 mm Hg after goniopuncture. No shallow or flat anterior chamber, endophthalmitis, or surgery-induced cataract was observed. However, 26 patients (25%) showed a progression of preexisting senile cataract (mean time 26 months; range 18 to 37 months). Injections of 5-fluorouracil were administered to 25 patients (23%) who underwent DSCI to salvage encysted blebs. Mean number of medications per patient was reduced from 2.3 +/- 0.7 to 0.5 +/- 0.7 (signed rank P<.0001). CONCLUSION: Deep sclerectomy with collagen implant appears to provide stable and reasonable control of IOP at long-term follow-up with few immediate postoperative complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Molecular docking softwares are one of the important tools of modern drug development pipelines. The promising achievements of the last 10 years emphasize the need for further improvement, as reflected by several recent publications (Leach et al., J Med Chem 2006, 49, 5851; Warren et al., J Med Chem 2006, 49, 5912). Our initial approach, EADock, showed a good performance in reproducing the experimental binding modes for a set of 37 different ligand-protein complexes (Grosdidier et al., Proteins 2007, 67, 1010). This article presents recent improvements regarding the scoring and sampling aspects over the initial implementation, as well as a new seeding procedure based on the detection of cavities, opening the door to blind docking with EADock. These enhancements were validated on 260 complexes taken from the high quality Ligand Protein Database [LPDB, (Roche et al., J Med Chem 2001, 44, 3592)]. Two issues were identified: first, the quality of the initial structures cannot be assumed and a manual inspection and/or a search in the literature are likely to be required to achieve the best performance. Second the description of interactions involving metal ions still has to be improved. Nonetheless, a remarkable success rate of 65% was achieved for a large scale blind docking assay, when considering only the top ranked binding mode and a success threshold of 2 A RMSD to the crystal structure. When looking at the five-top ranked binding modes, the success rate increases up to 76%. In a standard local docking assay, success rates of 75 and 83% were obtained, considering only the top ranked binding mode, or the five top binding modes, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: This is the first meta-analysis on the efficacy of composite resin restorations in anterior teeth. The objective of the present meta-analysis was to verify whether specific material classes, tooth conditioning methods and operational procedures influence the result for Class III and Class IV restorations. MATERIAL AND METHODS: The database SCOPUS and PubMed were searched for clinical trials on anterior resin composites without restricting the search to the year of publication. The inclusion criteria were: (1) prospective clinical trial with at least 2 years of observation; (2) minimal number of restorations at last recall=20; (3) report on drop-out rate; (4) report of operative technique and materials used in the trial, and (5) utilization of Ryge or modified Ryge evaluation criteria. For the statistical analysis, a linear mixed model was used with random effects to account for the heterogeneity between the studies. p-Values smaller than 0.05 were considered to be significant. RESULTS: Of the 84 clinical trials, 21 studies met the inclusion criteria, 14 of them for Class III restorations, 6 for Class IV restorations and 1 for closure of diastemata; the latter was included in the Class IV group. Twelve of the 21 studies started before 1991 and 18 before 2001. The estimated median overall success rate (without replacement) after 10 years for Class III composite resin restorations was 95% and for Class IV restorations 90%. The main reason for the replacement of Class IV restorations was bulk fractures, which occurred significantly more frequently with microfilled composites than with hybrid and macrofilled composites. Caries adjacent to restorations was infrequent in most studies and accounted only for about 2.5% of all replaced restorations after 10 years irrespective of the cavity class. Class III restorations with glass ionomer derivates suffered significantly more loss of anatomical form than did fillings with other types of material. When the enamel was acid-etched and no bonding agent was applied, significantly more restorations showed marginal staining and detectable margins compared to enamel etching with enamel bonding or the total etch technique; fillings with self-etching systems were in between of these two outcome variables. Bevelling of the enamel was associated with a significantly reduced deterioration of the anatomical form compared to no bevelling but not with less marginal staining or less detectable margins. The type of isolation (absolute/relative) had a statistically significant influence on marginal caries which, however, might be a random finding.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Implanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques. METHODS AND MATERIALS: Through a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new "mechanical adhesiolysis" maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication. RESULTS: Eighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted. CONCLUSION: These IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Thromboxane prostaglandin receptors have been implicated to be involved in the atherosclerotic process. We assessed whether Terutroban, a thromboxane prostaglandin receptor antagonist, affects the progression of atherosclerosis, as measured by common carotid intima-media thickness and carotid plaques. METHODS: A substudy was performed among 1141 participants of the aspirin-controlled Prevention of Cerebrovascular and Cardiovascular Events of Ischemic Origin with Terutroban in Patients with a History of Ischemic Stroke or Transient Ischemic Attack (PERFORM) trial. Common carotid intima-media thickness and carotid plaque occurrence was measured during a 3-year period. RESULTS: Baseline characteristics did not differ between Terutroban (n=592) and aspirin (n=549) treated patients and were similar as in the main study. Mean study and treatment duration were similar (28 and 25 months, respectively). In the Terutroban group, the annualized rate of change in common carotid intima-media thickness was 0.006 mm per year (95% confidence interval, -0.004 to 0.016) and -0.005 mm per year (95% confidence interval, -0.015 to 0.005) in the aspirin group. There was no statistically significant difference between the groups in the annualized rate of change of common carotid intima-media thickness (0.011 mm per year; 95% confidence interval, -0.003 to 0.025). At 12 months of follow-up, 66% of Terutroban patients had no emergent plaques, 31% had 1 to 2 emergent plaques, and 3% had ≥3 emergent plaques. In the aspirin group, the corresponding percentages were 64%, 32%, and 4%. Over time, there was no statistically significant difference in the number of emergent carotid plaques between treatment modalities (rate ratio, 0.91; 95% confidence interval, 0.77-1.07). CONCLUSIONS: Compared with aspirin, Terutroban did not beneficially affect progression of carotid atherosclerosis among well-treated patients with a history of ischemic stroke or transient ischemic attacks with an internal carotid stenosis <70%. CLINICAL TRIAL REGISTRATION URL: http://www.controlled-trials.com. Unique identifier: ISRCTN66157730.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We address the challenges of treating polarization and covalent interactions in docking by developing a hybrid quantum mechanical/molecular mechanical (QM/MM) scoring function based on the semiempirical self-consistent charge density functional tight-binding (SCC-DFTB) method and the CHARMM force field. To benchmark this scoring function within the EADock DSS docking algorithm, we created a publicly available dataset of high-quality X-ray structures of zinc metalloproteins ( http://www.molecular-modelling.ch/resources.php ). For zinc-bound ligands (226 complexes), the QM/MM scoring yielded a substantially improved success rate compared to the classical scoring function (77.0% vs 61.5%), while, for allosteric ligands (55 complexes), the success rate remained constant (49.1%). The QM/MM scoring significantly improved the detection of correct zinc-binding geometries and improved the docking success rate by more than 20% for several important drug targets. The performance of both the classical and the QM/MM scoring functions compare favorably to the performance of AutoDock4, AutoDock4Zn, and AutoDock Vina.