183 resultados para TO-HEAD RATIO


Relevância:

80.00% 80.00%

Publicador:

Resumo:

For free-breathing, high-resolution, three-dimensional coronary magnetic resonance angiography (MRA), the use of intravascular contrast agents may be helpful for contrast enhancement between coronary blood and myocardium. In six patients, 0.1 mmol/kg of the intravascular contrast agent MS-325/AngioMARK was given intravenously followed by double-oblique, free-breathing, three-dimensional inversion-recovery coronary MRA with real-time navigator gating and motion correction. Contrast-enhanced, three-dimensional coronary MRA images were compared with images obtained with a T2 prepulse (T2Prep) without exogenous contrast. The contrast-enhanced images demonstrated a 69% improvement in the contrast-to-noise ratio (6.6 +/- 1.1 vs. 11.1 +/- 2.5; P < 0.01) compared with the T2Prep approach. By using the intravascular agent, extensive portions (> 80 mm) of the native left and right coronary system could be displayed consistently with sub-millimeter in-plane resolution. The intravascular contrast agent, MS-325/AngioMARK, leads to a considerable enhancement of the blood/muscle contrast for coronary MRA compared with T2Prep techniques. The clinical value of the agent remains to be defined in a larger patient series. J. Magn. Reson. Imaging 1999;10:790-799.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To improve fat saturation in coronary MRA at 3T by using a spectrally selective adiabatic T2 -Prep (WSA-T2 -Prep). METHODS: A conventional adiabatic T2 -Prep (CA-T2 -Prep) was modified, such that the excitation and restoration pulses were of differing bandwidths. On-resonance spins are T2 -Prepared, whereas off-resonance spins, such as fat, are spoiled. This approach was combined with a CHEmically Selective Saturation (CHESS) pulse to achieve even greater fat suppression. Numerical simulations were followed by phantom validation and in vivo coronary MRA. RESULTS: Numerical simulations demonstrated that augmenting a CHESS pulse with a WSA-T2 -Prep improved robustness to B1 inhomogeneities and that this combined fat suppression was effective over a broader spectral range than that of a CHESS pulse in a conventional T2 -Prepared sequence. Phantom studies also demonstrated that the WSA-T2 -Prep+CHESS combination produced greater fat suppression across a range of B1 values than did a CA-T2 -Prep+CHESS combination. Lastly, in vivo measurements demonstrated that the contrast-to-noise ratio between blood and myocardium was not adversely affected by using a WSA-T2 -Prep, despite the improved abdominal and epicardial fat suppression. Additionally, vessel sharpness improved. CONCLUSION: The proposed WSA-T2 -Prep method was shown to improve fat suppression and vessel sharpness as compared to a CA-T2 -Prep technique, and to also increase fat suppression when combined with a CHESS pulse.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In coronary magnetic resonance angiography, a magnetization-preparation scheme for T2 -weighting (T2 Prep) is widely used to enhance contrast between the coronary blood-pool and the myocardium. This prepulse is commonly applied without spatial selection to minimize flow sensitivity, but the nonselective implementation results in a reduced magnetization of the in-flowing blood and a related penalty in signal-to-noise ratio. It is hypothesized that a spatially selective T2 Prep would leave the magnetization of blood outside the T2 Prep volume unaffected and thereby lower the signal-to-noise ratio penalty. To test this hypothesis, a spatially selective T2 Prep was implemented where the user could freely adjust angulation and position of the T2 Prep slab to avoid covering the ventricular blood-pool and saturating the in-flowing spins. A time gap of 150 ms was further added between the T2 Prep and other prepulses to allow for in-flow of a larger volume of unsaturated spins. Consistent with numerical simulation, the spatially selective T2 Prep increased in vivo human coronary artery signal-to-noise ratio (42.3 ± 2.9 vs. 31.4 ± 2.2, n = 22, P < 0.0001) and contrast-to-noise-ratio (18.6 ± 1.5 vs. 13.9 ± 1.2, P = 0.009) as compared to those of the nonselective T2 Prep. Additionally, a segmental analysis demonstrated that the spatially selective T2 Prep was most beneficial in proximal and mid segments where the in-flowing blood volume was largest compared to the distal segments. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Surface magnetic resonance imaging (MRI) for aortic plaque assessment is limited by the trade-off between penetration depth and signal-to-noise ratio (SNR). For imaging the deep seated aorta, a combined surface and transesophageal MRI (TEMRI) technique was developed 1) to determine the individual contribution of TEMRI and surface coils to the combined signal, 2) to measure the signal improvement of a combined surface and TEMRI over surface MRI, and 3) to assess for reproducibility of plaque dimension analysis. METHODS AND RESULTS: In 24 patients six black blood proton-density/T2-weighted fast-spin echo images were obtained using three surface and one TEMRI coil for SNR measurements. Reproducibility of plaque dimensions (combined surface and TEMRI) was measured in 10 patients. TEMRI contributed 68% of the signal in the aortic arch and descending aorta, whereas the overall signal gain using the combined technique was up to 225%. Plaque volume measurements had an intraclass correlation coefficient of as high as 0.97. CONCLUSION: Plaque volume measurements for the quantification of aortic plaque size are highly reproducible for combined surface and TEMRI. The TEMRI coil contributes considerably to the aortic MR signal. The combined surface and TEMRI approach improves aortic signal significantly as compared to surface coils alone. CONDENSED ABSTRACT: Conventional MRI aortic plaque visualization is limited by the penetration depth of MRI surface coils and may lead to suboptimal image quality with insufficient reproducibility. By combining a transesophageal MRI (TEMRI) with surface MRI coils we enhanced local and overall image SNR for improved image quality and reproducibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The large spatial inhomogeneity in transmit B(1) field (B(1)(+)) observable in human MR images at high static magnetic fields (B(0)) severely impairs image quality. To overcome this effect in brain T(1)-weighted images, the MPRAGE sequence was modified to generate two different images at different inversion times, MP2RAGE. By combining the two images in a novel fashion, it was possible to create T(1)-weighted images where the result image was free of proton density contrast, T(2) contrast, reception bias field, and, to first order, transmit field inhomogeneity. MP2RAGE sequence parameters were optimized using Bloch equations to maximize contrast-to-noise ratio per unit of time between brain tissues and minimize the effect of B(1)(+) variations through space. Images of high anatomical quality and excellent brain tissue differentiation suitable for applications such as segmentation and voxel-based morphometry were obtained at 3 and 7 T. From such T(1)-weighted images, acquired within 12 min, high-resolution 3D T(1) maps were routinely calculated at 7 T with sub-millimeter voxel resolution (0.65-0.85 mm isotropic). T(1) maps were validated in phantom experiments. In humans, the T(1) values obtained at 7 T were 1.15+/-0.06 s for white matter (WM) and 1.92+/-0.16 s for grey matter (GM), in good agreement with literature values obtained at lower spatial resolution. At 3 T, where whole-brain acquisitions with 1 mm isotropic voxels were acquired in 8 min, the T(1) values obtained (0.81+/-0.03 s for WM and 1.35+/-0.05 for GM) were once again found to be in very good agreement with values in the literature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increased serum levels of homocysteine and uric acid have each been associated with cardiovascular risk. We analyzed whether homocysteine and uric acid were associated with glomerular filtration rate (GFR) and albuminuria independently of each other. We also investigated the association of MTHFR polymorphisms related to homocysteine with albuminuria to get further insight into causality. This was a cross-sectional population-based study in Caucasians (n = 5913). Hyperhomocysteinemia was defined as total serum homocysteine ≥ 15 μmol/L. Albuminuria was defined as urinary albumin-to-creatinine ratio > 30 mg/g. Uric acid was associated positively with homocysteine (r = 0.246 in men and r = 0.287 in women, P < 0.001). The prevalence of albuminuria increased across increasing homocysteine categories (from 6.4% to 17.3% in subjects with normal GFR and from 3.5% to 14.5% in those with reduced GFR, P for trend < 0.005). Hyperhomocysteinemia (OR = 2.22, 95% confidence interval: 1.60-3.08, P < 0.001) and elevated serum uric acid (OR = 1.27, 1.08-1.50, per 100 μmol/L, P = 0.004) were significantly associated with albuminuria, independently of hypertension and type 2 diabetes. The 2-fold higher risk of albuminuria associated with hyperhomocysteinemia was similar to the risk associated with hypertension or diabetes. MTHFR alleles related to higher homocysteine were associated with increased risk of albuminuria. In the general adult population, elevated serum homocysteine and uric acid were associated with albuminuria independently of each other and of renal function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Chronic obstructive pulmonary disease (COPD) has been associated with increased risk for heart failure (HF). The impact of subclinical abnormal spirometric findings on HF risk among older adults without history of COPD is not well elucidated. Methods: We evaluated 2125 participants (age 73.6±2.9 years; 50.5% men; 62.3% white; 45.6/9.4% past/current smokers; body mass index [BMI] 27.2±4.6 kg/m2) without prevalent COPD or HF who underwent baseline spirometry in the Health ABC Study. Abnormal lung function was defined either as forced vital capacity (FVC) below lower limit of normal (LLN) or forced expiratory volume in 1st sec (FEV1) to FVC ratio below LLN. Results: On follow-up (median, 9.4 years), 68 of 350 (19.4%) participants with abnormal lung function developed HF, as compared to 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.74 -3.06; P<.001). This increased risk persisted after adjusting for all other independent predictors of HF in the Health ABC Study, BMI, incident coronary events, and several inflammatory markers (HR, 1.82; 95% CI, 1.30 -2.54; P<.001), and remained constant over time. Baseline FVC and FEV1 had a linear association with HF risk (Figure). In adjusted models, HF risk increased by 21% (95% CI, 10 -36%) per 10% decrease in FVC and 18% (95% CI, 10 -28%) per 10% decrease in FEV1 (both P<.001); this association persisted among participants with normal lung function at baseline. Findings were consistent across sex, race, and smoking status. Conclusions: Subclinical abnormal spirometric findings are prevalent among older adults and are independently associated with risk for incident HF.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of this study was to improve the blood-pool signal-to-noise ratio (SNR) and blood-myocardium contrast-to-noise ratio (CNR) of slow-infusion 3-T whole-heart coronary MR angiography (MRA).SUBJECTS AND METHODS. In 2D sensitivity encoding (SENSE), the number of acquired k-space lines is reduced, allowing less radiofrequency excitation per cardiac cycle and a longer TR. The former can be exploited for signal enhancement with a higher radiofrequency excitation angle, and the latter leads to noise reduction due to lower data-sampling bandwidth. Both effects contribute to SNR gain in coronary MRA when spatial and temporal resolution and acquisition time remain identical. Numeric simulation was performed to select the optimal 2D SENSE pulse sequence parameters and predict the SNR gain. Eleven patients underwent conventional unenhanced and the proposed 2D SENSE contrast-enhanced coronary MRA acquisition. Blood-pool SNR, blood-myocardium CNR, visible vessel length, vessel sharpness, and number of side branches were evaluated.RESULTS. Consistent with the numeric simulation, using 2D SENSE in contrast-enhanced coronary MRA resulted in significant improvement in aortic blood-pool SNR (unenhanced vs contrast-enhanced, 37.5 +/- 14.7 vs 121.3 +/- 44.0; p < 0.05) and CNR (14.4 +/- 6.9 vs 101.5 +/- 40.8; p < 0.05) in the patient sample. A longer length of left anterior descending coronary artery was visualized, but vessel sharpness, coronary artery coverage, and image quality score were not improved with the proposed approach.CONCLUSION. In combination with contrast administration, 2D SENSE was found effective in improving SNR and CNR in 3-T whole-heart coronary MRA. Further investigation of cardiac motion compensation is necessary to exploit the SNR and CNR advantages and to achieve submillimeter spatial resolution.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The prevalence of hyperuricemia has rarely been investigated in developing countries. The purpose of the present study was to investigate the prevalence of hyperuricemia and the association between uric acid levels and the various cardiovascular risk factors in a developing country with high average blood pressures (the Seychelles, Indian Ocean, population mainly of African origin). METHODS: This cross-sectional health examination survey was based on a population random sample from the Seychelles. It included 1011 subjects aged 25 to 64 years. Blood pressure (BP), body mass index (BMI), waist circumference, waist-to-hip ratio, total and HDL cholesterol, serum triglycerides and serum uric acid were measured. Data were analyzed using scatterplot smoothing techniques and gender-specific linear regression models. RESULTS: The prevalence of a serum uric acid level >420 micromol/L in men was 35.2% and the prevalence of a serum uric acid level >360 micromol/L was 8.7% in women. Serum uric acid was strongly related to serum triglycerides in men as well as in women (r = 0.73 in men and r = 0.59 in women, p < 0.001). Uric acid levels were also significantly associated but to a lesser degree with age, BMI, blood pressure, alcohol and the use of antihypertensive therapy. In a regression model, triglycerides, age, BMI, antihypertensive therapy and alcohol consumption accounted for about 50% (R2) of the serum uric acid variations in men as well as in women. CONCLUSIONS: This study shows that the prevalence of hyperuricemia can be high in a developing country such as the Seychelles. Besides alcohol consumption and the use of antihypertensive therapy, mainly diuretics, serum uric acid is markedly associated with parameters of the metabolic syndrome, in particular serum triglycerides. Considering the growing incidence of obesity and metabolic syndrome worldwide and the potential link between hyperuricemia and cardiovascular complications, more emphasis should be put on the evolving prevalence of hyperuricemia in developing countries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relative efficacy and safety profile of bevacizumab versus ranibizumab intravitreal injections for the treatment of neovascular age-related macular degeneration (AMD). DESIGN: Multicenter, prospective, noninferiority, double-masked, randomized clinical trial performed in 38 French ophthalmology centers. The noninferiority limit was 5 letters. PARTICIPANTS: Patients aged ≥50 years were eligible if they presented with subfoveal neovascular AMD, with best-corrected visual acuity (BVCA) in the study eye of between 20/32 and 20/320 measured on the Early Treatment of Diabetic Retinopathy Study chart and a lesion area of less than 12 optic disc areas (DA). METHODS: Patients were randomly assigned to intravitreal administration of bevacizumab (1.25 mg) or ranibizumab (0.50 mg). Hospital pharmacies were responsible for preparing, blinding, and dispensing treatments. Patients were followed for 1 year, with a loading dose of 3 monthly intravitreal injections, followed by an as-needed regimen (1 injection in case of active disease) for the remaining 9 months with monthly follow-up. MAIN OUTCOME MEASURES: Mean change in visual acuity at 1 year. RESULTS: Between June 2009 and November 2011, 501 patients were randomized. In the per protocol analysis, bevacizumab was noninferior to ranibizumab (bevacizumab minus ranibizumab +1.89 letters; 95% confidence interval [CI], -1.16 to +4.93, P < 0.0001). The intention-to-treat analysis was concordant. The mean number of injections was 6.8 in the bevacizumab group and 6.5 in the ranibizumab group (P = 0.39). Both drugs reduced the central subfield macular thickness, with a mean decrease of 95 μm for bevacizumab and 107 μm for ranibizumab (P = 0.27). There were no significant differences in the presence of subretinal or intraretinal fluid at final evaluation, dye leakage on angiogram, or change in choroidal neovascular area. The proportion of patients with serious adverse events was 12.6% in the bevacizumab group and 12.1% in the ranibizumab group (P = 0.88). The proportion of patients with serious systemic or ocular adverse events was similar in both groups. CONCLUSIONS: Bevacizumab was noninferior to ranibizumab for visual acuity at 1 year with similar safety profiles. Ranibizumab tended to have a better anatomic outcome. The results are similar to those of previous head-to-head studies. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the prognostic factors and the ophthalmologic follow-up on cataract formation following total body irradiation (TBI) prior to bone marrow transplantation (BMT). METHODS AND MATERIALS: Between 1980 and 1992, 494 patients were referred to our department for TBI prior to BMT. The mean age was 32 +/- 11 (median: 32, range: 2-63) years and the male to female ratio was 1.6 (304:190). The majority of patients were treated for acute leukemia (lymphoblastic, n = 177, 36%; or nonlymphoblastic , n = 139, 28%); 80 (16%) for chronic myeloid leukemia, 60 (12%) for non-Hodgkin's lymphoma, 23 (5%) for multiple myeloma, and 15 (3%) for other malignancies. Two hundred and fifty-four (51%) patients were grafted in the first complete remission (CR), 118 (24%) in second CR. Allogenic BMT was performed in 210 (43%) patients, and autologous BMT in 284 (57%). Methotrexate combined to steroids (n = 47, 22%) or to cyclosporine (n = 163, 78%) was administered for graft-versus-host disease (GvHD) prophylaxis. In 188 patients (38%), heparin was used in the prevention of veno-occlusive disease (VOD) of the liver. Furthermore, steroid administration was registered in 223 (45%). The conditioning chemotherapy consisted of cyclophosphamide (Cy) alone in 332 (67%) patients. Total-body irradiation was administered either in single dose (STBI; 10 Gy in 1 day, n = 291) or in six fractions (FTBI; 12 Gy over 3 consecutive days, n = 203) before BMT. The mean instantaneous dose rate was 0.0574 +/- 0.0289 Gy/min (0.024-0.1783). It was < 0.048 Gy/min in 157 patients (LOW group), > or = 0.048 Gy/min and <0.09 Gy/min in 301 patients (MEDIUM group), and > or = 0.09 Gy/min in 36 patients (HIGH group). RESULTS: When considering all patients, 42 (8.5%) patients developed cataracts after 13 to 72 months (median: 42 months) with a 5-year estimated cataract incidence (ECI) of 23%. Thirty-three (11.3%) out of 291 patients in the STBI group, and 9 (4.4%) out of 203 patients in the FTBI group developed cataracts with 5-year estimated incidences of 34 and 11%, respectively (p = 0.0004). Seven (19.4%) out of 36 patients in the HIGH group, 33 (10.9%) out of 301 in the MEDIUM group, and 2 (1.2%) out of 157 in the LOW group developed cataracts with respective 5-year cataract incidences of 54%, 30%, and 3.5% (HIGH vs. MEDIUM, p = 0.07; MEDIUM vs. LOW, p = 0.0001; HIGH vs. LOW, p < 0.0001). On the other hand, patients who received heparin as prophylactic treatment against VOD of the liver had less cataracts than those who did not receive (5-year ECI of 16% vs. 28%, respectively; p = 0.01). There was no statistically significant difference in terms of 5-year ECI according to age, sex, administration of steroids, GvHD prophylaxis, type of BMT, or previous cranial radiotherapy in children. Multivariate analysis revealed that the instantaneous dose rate (p = 0.001), and the administration of heparin against VOD (p = 0.05) were the two independent factors influencing the cataract incidence, while age, fractionation, and use of steroids were not. Among the 42 patients who developed cataracts, 38 had bilateral extracapsular cataract extraction and intraocular lens implantation, and only 4 (10%) developed secondary cataracts in a median follow-up period of 39 months. CONCLUSION: Among the abovementioned TBI parameters, high instantaneous dose rate seems to be the main risk factor of cataract formation, and the administration of heparin appears to have a protective role in cataractogenesis. On the other hand, ionizing radiation seems to have a protective effect on posterior capsule opacification following extracapsular cataract extraction and intraocular lens implantation.