281 resultados para Sensitive techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous ablative procedures allow curative treatment of stage BCLC 0 or BCLC A hepatocellular carcinoma, as well as liver metastases of colorectal cancer. Several methods exist including radiofrequency ablation, the most commonly used. These techniques can be used in combination with surgical excision or alone if surgery is contraindicated. They are associated with significantly reduced mortality as compared to surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La faiblesse des muscles respiratoires peut entraîner une dyspnée, un encombrement bronchique et une insuffisance respiratoire potentiellement fatale. L'évaluation de la force musculaire respiratoire s'impose donc dans les affections neuro-musculaires, mais également dans les situations de dyspnée inexpliquée par une première évaluation cardiaque et pulmonaire. À la spirométrie, une faiblesse musculaire est suspectée sur la base de la boucle débit-volume montrant un débit de pointe émoussé et une fin prématurée de l'expiration. Une diminution importante de la capacité vitale en position couchée suggère une paralysie diaphragmatique. La force inspiratoire est mesurée par la pression inspiratoire maximale (PImax) contre une quasi-occlusion des voies aériennes. Ce test relativement difficile est d'interprétation délicate en cas de collaboration insuffisante. La mesure de la pression nasale sniff (SNIP) est une alternative utile, car elle élimine le problème des fuites autour de l'embout buccal et la réalisation du reniflement est facile. De même, la pression trans-diaphragmatique sniff mesure la force du diaphragme au moyen de sondes oesophagienne et gastrique. En cas de collaboration insuffisante, on peut recourir à la stimulation magnétique des nerfs phréniques qui induit une contraction non-volontaire du diaphragme. La force expiratoire est mesurée par la pression expiratoire maximale (PEmax) contre une quasi-occlusion. La force disponible pour tousser est mesurée par la pression gastrique à la toux, ou plus simplement par le débit de pointe à la toux. Chez les patients à risque, la mesure de la force des muscles respiratoires permet d'instaurer à temps une assistance ventilatoire ou à la toux.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A generic LC-MS approach for the absolute quantification of undigested peptides in plasma at mid-picomolar levels is described. Nine human peptides namely, brain natriuretic peptide (BNP), substance P (SubP), parathyroid hormone 1-34 (PTH), C-peptide, orexines A and B (Orex-A and -B), oxytocin (Oxy), gonadoliberin-1 (gonadothropin releasing-hormone or luteinizing hormone-releasing hormone, LHRH) and α-melanotropin (α-MSH) were targeted. Plasma samples were extracted via a 2-step procedure: protein precipitation using 1vol of acetonitrile followed by ultrafiltration of supernatants on membranes with a MW cut-off of 30 kDa. By applying a specific LC-MS setup, large volumes of filtrates (e.g., 2×750 μL) were injected and the peptides were trapped on a 1mm i.d.×10 mm length C8 column using a 10× on-line dilution. Then, the peptides were back-flushed and a second on-line dilution (2×) was applied during the transfer step. The refocalized peptides were resolved on a 0.3mm i.d. C18 analytical column. Extraction recovery, matrix effect and limits of detection were evaluated. Our comprehensive protocol demonstrates a simple and efficient sample preparation procedure followed by the analysis of peptides with limits of detection in the mid-picomolar range. This generic approach can be applied for the determination of most therapeutic peptides and possibly for endogenous peptides with latest state-of-the-art instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Squamous cell and basocellular carcinoma of the face have an excellent prognosis. Nevertherless, a small proportion therefore of these cancers differs by a much more aggressive behavior, caracterised by a tendency to infiltrate the deep facial soft tissues and facial bones. The invasion of the craniofacial skeleton and the intracranial structures follows the embryonic fusion lines or the facial sensitive or motor nerves, sometimes years after the initial treatment. The development of craniofacial surgery, reconstruction techniques and conformational radiotherapy allows us now to offer curative guided treatments, for these advanced staged tumors with a remaining limited prognosis. A therapeutic benefit implies a rigorous selection of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mountains and mountain societies provide a wide range of goods and services to humanity, but they are particularly sensitive to the effects of global environmental change. Thus, the definition of appropriate management regimes that maintain the multiple functions of mountain regions in a time of greatly changing climatic, economic, and societal drivers constitutes a significant challenge. Management decisions must be based on a sound understanding of the future dynamics of these systems. The present article reviews the elements required for an integrated effort to project the impacts of global change on mountain regions, and recommends tools that can be used at 3 scientific levels (essential, improved, and optimum). The proposed strategy is evaluated with respect to UNESCO's network of Mountain Biosphere Reserves (MBRs), with the intention of implementing it in other mountain regions as well. First, methods for generating scenarios of key drivers of global change are reviewed, including land use/land cover and climate change. This is followed by a brief review of the models available for projecting the impacts of these scenarios on (1) cryospheric systems, (2) ecosystem structure and diversity, and (3) ecosystem functions such as carbon and water relations. Finally, the cross-cutting role of remote sensing techniques is evaluated with respect to both monitoring and modeling efforts. We conclude that a broad range of techniques is available for both scenario generation and impact assessments, many of which can be implemented without much capacity building across many or even most MBRs. However, to foster implementation of the proposed strategy, further efforts are required to establish partnerships between scientists and resource managers in mountain areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensity modulated radiotherapy (IMRT) is a conformal radiotherapy that produces concave and irregular target volume dose distributions. IMRT has a potential to reduce the volume of healthy tissue irradiated to a high dose, but this often at the price of an increased volume of normal tissue irradiated to a low dose. Clinical benefits of IMRT are expected to be most pronounced at the body sites where sensitive normal tissues surround or are located next to a target with a complex 3D shape. The irradiation doses needed for tumor control are often markedly higher than the tolerance of the radiation sensitive structures such as the spinal cord, the optic nerves, the eyes, or the salivary glands in the treatment of head and neck cancer. Parotid gland salivary flow is markedly reduced following a cumulative dose of 30 50 Gy given with conventional fractionation and xerostomia may be prevented in most patients using a conformal parotid-sparing radiotherapy technique. However, in cohort studies where IMRT was compared with conventional and conformal radiotherapy techniques in the treatment of laryngeal or oropharyngeal carcinoma, the dosimetric advantage of IMRT translated into a reduction of late salivary toxicity with no apparent adverse impact on the tumor control. IMRT might reduce the radiation dose to the major salivary glands and the risk of permanent xerostomia without compromizing the likelihood for cure. Alternatively, IMRT might allow the target dose escalation at a given level of normal tissue damage. We describe here the clinical results on postirradiation salivary gland function in head and neck cancer patients treated with IMRT, and the technical aspects of IMRT applied. The results suggest that the major salivary gland function can be maintained with IMRT without a need to compromise the clinical target volume dose, or the locoregional control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review paper reports the consensus of a technical workshop hosted by the European network, NanoImpactNet (NIN). The workshop aimed to review the collective experience of working at the bench with manufactured nanomaterials (MNMs), and to recommend modifications to existing experimental methods and OECD protocols. Current procedures for cleaning glassware are appropriate for most MNMs, although interference with electrodes may occur. Maintaining exposure is more difficult with MNMs compared to conventional chemicals. A metal salt control is recommended for experiments with metallic MNMs that may release free metal ions. Dispersing agents should be avoided, but if they must be used, then natural or synthetic dispersing agents are possible, and dispersion controls essential. Time constraints and technology gaps indicate that full characterisation of test media during ecotoxicity tests is currently not practical. Details of electron microscopy, dark-field microscopy, a range of spectroscopic methods (EDX, XRD, XANES, EXAFS), light scattering techniques (DLS, SLS) and chromatography are discussed. The development of user-friendly software to predict particle behaviour in test media according to DLVO theory is in progress, and simple optical methods are available to estimate the settling behaviour of suspensions during experiments. However, for soil matrices such simple approaches may not be applicable. Alternatively, a Critical Body Residue approach may be taken in which body concentrations in organisms are related to effects, and toxicity thresholds derived. For microbial assays, the cell wall is a formidable barrier to MNMs and end points that rely on the test substance penetrating the cell may be insensitive. Instead assays based on the cell envelope should be developed for MNMs. In algal growth tests, the abiotic factors that promote particle aggregation in the media (e.g. ionic strength) are also important in providing nutrients, and manipulation of the media to control the dispersion may also inhibit growth. Controls to quantify shading effects, and precise details of lighting regimes, shaking or mixing should be reported in algal tests. Photosynthesis may be more sensitive than traditional growth end points for algae and plants. Tests with invertebrates should consider non-chemical toxicity from particle adherence to the organisms. The use of semi-static exposure methods with fish can reduce the logistical issues of waste water disposal and facilitate aspects of animal husbandry relevant to MMNs. There are concerns that the existing bioaccumulation tests are conceptually flawed for MNMs and that new test(s) are required. In vitro testing strategies, as exemplified by genotoxicity assays, can be modified for MNMs, but the risk of false negatives in some assays is highlighted. In conclusion, most protocols will require some modifications and recommendations are made to aid the researcher at the bench. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetically engineered organisms expressing spectroscopically active reporter molecules in response to chemical effectors display great potential as living transducers in sensing applications. Green fluorescent protein (gfp gene) bioreporters have distinct advantages over luminescent couterparts (lux gene), including applicability at the single-cell level, but are typically less sensitive. Here we describe a gfp-bearing bioreporter that is sensitive to naphthalene (a poorly water soluble pollutant behaving like a large class of hydrophobic compounds), is suitable for use in chemical assays and bioavailability studies, and has detection limits comparable to lux-bearing bioreporters for higher efficiency detection strategies. Simultaneously, we find that the exploitation of population response data from single-cell analysis is not an algorithmic conduit to enhanced signal detection and hence lower effector detection limits, as normally assumed. The assay reported functions to equal effect with or without biocide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pseudohypoaldosteronism type 1 (PHA-1) is an inherited disease characterized by severe neonatal salt-wasting and caused by mutations in subunits of the amiloride-sensitive epithelial sodium channel (ENaC). A missense mutation (G37S) of the human ENaC beta subunit that causes loss of ENaC function and PHA-1 replaces a glycine that is conserved in the N-terminus of all members of the ENaC gene family. We now report an investigation of the mechanism of channel inactivation by this mutation. Homologous mutations, introduced into alpha, beta or gamma subunits, all significantly reduce macroscopic sodium channel currents recorded in Xenopus laevis oocytes. Quantitative determination of the number of channel molecules present at the cell surface showed no significant differences in surface expression of mutant compared with wild-type channels. Single channel conductances and ion selectivities of the mutant channels were identical to that of wild-type. These results suggest that the decrease in macroscopic Na currents is due to a decrease in channel open probability (P(o)), suggesting that mutations of a conserved glycine in the N-terminus of ENaC subunits change ENaC channel gating, which would explain the disease pathophysiology. Single channel recordings of channels containing the mutant alpha subunit (alphaG95S) directly demonstrate a striking reduction in P(o). We propose that this mutation favors a gating mode characterized by short-open and long-closed times. We suggest that determination of the gating mode of ENaC is a key regulator of channel activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histoire discursive du « cinéma-vérité ». Techniques, controverses, historiographie (1960-1970) retrace l'histoire du succès et de la disgrâce du label « cinéma vérité » en France qui, entre 1960 - date à laquelle Edgar Morin publie son essai programmatique « Pour un nouveau "cinéma vérité" » dans France Observateur - et 1964-65 - moment où la notion commence à perdre en popularité - sert de bannière à un mouvement cinématographique supposé renouveler les rapports entre cinéma et réalité. Une vingtaine de films - comme Chronique d'un été de Jean Rouch et Edgar Morin, Primary de Richard Leacock et Robert Drew, Les Inconnus de la terre ou Regard sur la folie de Mario Ruspoli, Hitler, connais pas de Bertrand Blier, Le Chemin de la mauvaise route de Jean Herman, Le Joli Mai de Chris Marker, La Punition de Jean Rouch ou Pour la Suite du monde de Michel Brault et Pierre Perrault - revendiquent cette étiquette ou y sont associés par la presse hexagonale qui y consacre des centaines d'articles. En effet, la sortie en salles de ces « films-vérité » provoque en France de virulentes controverses qui interrogent aussi bien l'éthique de ces projets où les personnes filmées sont supposées révéler une vérité intime face à la caméra, le statut artistique de ces réalisations, ou l'absence d'un engagement politique marqué des « cinéastes-vérité » devant les questions abordées par les protagonistes (par exemple la Guerre d'Algérie, la jeunesse française, la politique internationale). L'hypothèse à la base de cette recherche est que la production cinématographique qui se réclame du « cinéma-vérité » se caractérise par une étroite corrélation entre film et discours sur le film. D'une part car la première moitié de la décennie est marquée par de nombreuses rencontres entre les « cinéastes vérité », les critiques ou les constructeurs de caméras légères et de magnétophones synchrones ; rencontres qui contribuent à accentuer et à médiatiser les dissensions au sein du mouvement. D'autre part car la particularité de nombreux projets est d'inclure dans le film des séquences méta-discursives où les participants, les réalisateurs ou des experts débattent de la réussite du tournage. Ce travail montre que le succès du mouvement entre 1960 et 1964-65 ne se fait pas malgré une forte polémique, mais qu'au contraire, nombre de longs métrages intègrent la controverse en leur sein, interrogeant, sur un plan symbolique, l'abolition du filtre entre le film et son spectateur. Si les films qui s'inscrivent dans la mouvance du « cinéma vérité » octroient une large place à la confrontation, c'est parce que la « vérité » est pensée comme un processus dialectique, qui émerge dans une dynamique d'échanges (entre les réalisateurs de cette mouvance, entre les protagonistes, entre le film et son public). Les querelles internes ou publiques qui rythment ces quelques années font partie du dispositif « cinéma-vérité » et justifient de faire l'histoire de ce mouvement cinématographique par le biais des discours qu'il a suscité au sein de la cinéphilie française.