130 resultados para SCANNING FORCE
Resumo:
A clear and rigorous definition of muscle moment-arms in the context of musculoskeletal systems modelling is presented, using classical mechanics and screw theory. The definition provides an alternative to the tendon excursion method, which can lead to incorrect moment-arms if used inappropriately due to its dependency on the choice of joint coordinates. The definition of moment-arms, and the presented construction method, apply to musculoskeletal models in which the bones are modelled as rigid bodies, the joints are modelled as ideal mechanical joints and the muscles are modelled as massless, frictionless cables wrapping over the bony protrusions, approximated using geometric surfaces. In this context, the definition is independent of any coordinate choice. It is then used to solve a muscle-force estimation problem for a simple 2D conceptual model and compared with an incorrect application of the tendon excursion method. The relative errors between the two solutions vary between 0% and 100%.
Resumo:
The atomic force microscope is a convenient tool to probe living samples at the nanometric scale. Among its numerous capabilities, the instrument can be operated as a nano-indenter to gather information about the mechanical properties of the sample. In this operating mode, the deformation of the cantilever is displayed as a function of the indentation depth of the tip into the sample. Fitting this curve with different theoretical models permits us to estimate the Young's modulus of the sample at the indentation spot. We describe what to our knowledge is a new technique to process these curves to distinguish structures of different stiffness buried into the bulk of the sample. The working principle of this new imaging technique has been verified by finite element models and successfully applied to living cells.
Resumo:
The aim of this article is to estimate the impact of various factors related to role conflict theory and preference theory on the reduction of women's labour force participation after their transition to parenthood. Objective and subjective dimensions of women's labour force participation are assessed. The empirical test is based on a survey of couples with children in Switzerland. Results show that compared to structural factors associated with role conflict reduction, preferences have little impact on mothers' labour force participation, but explain a good deal of their frustration if the factual situation does not correspond to their wishes. Structural factors, such as occupation, economic resources, childcare, and an urban environment, support mothers' labour force participation, whereas active networks and a home centred lifestyle preference help them to cope with frustrations.
Resumo:
Anticoagulants are a mainstay of cardiovascular therapy, and parenteral anticoagulants have widespread use in cardiology, especially in acute situations. Parenteral anticoagulants include unfractionated heparin, low-molecular-weight heparins, the synthetic pentasaccharides fondaparinux, idraparinux and idrabiotaparinux, and parenteral direct thrombin inhibitors. The several shortcomings of unfractionated heparin and of low-molecular-weight heparins have prompted the development of the other newer agents. Here we review the mechanisms of action, pharmacological properties and side effects of parenteral anticoagulants used in the management of coronary heart disease treated with or without percutaneous coronary interventions, cardioversion for atrial fibrillation, and prosthetic heart valves and valve repair. Using an evidence-based approach, we describe the results of completed clinical trials, highlight ongoing research with currently available agents, and recommend therapeutic options for specific heart diseases.
Resumo:
Ce travail s'inscrit dans le cadre d'un projet dont l'objectif est d'étudier les propriétés d'adhésion du ClfA au fibrinogène à l'aide de l'AFM. Plus précisément, le mode « Force spectroscopy » de l'AFM sera utilisé afin de mesurer les forces d'interactions entre le fibrinogène et le ClfA cloné à des bactéries ne comportant pas de MSCRAMMs et n'étant pas pathogène pour l'homme. Puis les forces d'interactions seront mesurées entre le fibrinogène et la surface des S. aureus. Une meilleure connaissance des propriétés d'adhésion des S. aureus au ClfA contribuerait ainsi au développement de la recherche dans ce domaine et à de potentielle future thérapie contre les infections à S. aureus.
Resumo:
Over the last two decades, Atomic Force Microscopy (AFM) has emerged as the tool of choice to image living organisms in a near-physiological environment. Whereas fluorescence microscopy techniques allow labeling and tracking of components inside cells and the observation of dynamic processes, AFM is mainly a surface technique that can be operated on a wide range of substrates including biological samples. AFM enables extraction of topographical, mechanical and chemical information from these samples.
Resumo:
Purpose: To investigate the differences between the Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: Eighty nine eyes of 46 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter / 500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter / 695nm barrier filter) before and after FFA. The quality of the FAF images was estimated, compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo- and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior quality in 18 eyes, while Topcon images were estimated superior in 21 eyes. No difference was found in 50 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found to strongly increase the likelihood of better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (71%), but showed mild autofluorescence on Topcon (88%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 52% Iso-FAF, in 43% mild Hypo-FAF, and in 5% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to exudation showed better on HRA. Pigment epithelium detachment showed identical FAF behaviour on the border, but reduced FAF with Topcon in the center. Cystic edema was visible only on HRA in a petaloid pattern. Hard exsudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blocage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract or poor fixation. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behaviour, there are differences between the two systems which need to be taken into account when interpreting the images.
Resumo:
In the last two decades, the third-dimension has become a focus of attention in electron microscopy to better understand the interactions within subcellular compartments. Initially, transmission electron tomography (TEM tomography) was introduced to image the cell volume in semi-thin sections (∼500nm). With the introduction of the focused ion beam scanning electron microscope, a new tool, FIB-SEM tomography, became available to image much larger volumes. During TEM tomography and FIB-SEM tomography, the resin section is exposed to a high electron/ion dose such that the stability of the resin embedded biological sample becomes an important issue. The shrinkage of a resin section in each dimension, especially in depth, is a well-known phenomenon. To ensure the dimensional integrity of the final volume of the cell, it is important to assess the properties of the different resins and determine the formulation which has the best stability in the electron/ion beam. Here, eight different resin formulations were examined. The effects of radiation damage were evaluated after different times of TEM irradiation. To get additional information on mass-loss and the physical properties of the resins (stiffness and adhesion), the topography of the irradiated areas was analysed with atomic force microscopy (AFM). Further, the behaviour of the resins was analysed after ion milling of the surface of the sample with different ion currents. In conclusion, two resin formulations, Hard Plus and the mixture of Durcupan/Epon, emerged that were considerably less affected and reasonably stable in the electron/ion beam and thus suitable for the 3-D investigation of biological samples.
Resumo:
AIM: Atomic force microscopy nanoindentation of myofibers was used to assess and quantitatively diagnose muscular dystrophies from human patients. MATERIALS & METHODS: Myofibers were probed from fresh or frozen muscle biopsies from human dystrophic patients and healthy volunteers, as well as mice models, and Young's modulus stiffness values were determined. RESULTS: Fibers displaying abnormally low mechanical stability were detected in biopsies from patients affected by 11 distinct muscle diseases, and Young's modulus values were commensurate to the severity of the disease. Abnormal myofiber resistance was also observed from consulting patients whose muscle condition could not be detected or unambiguously diagnosed otherwise. DISCUSSION & CONCLUSION: This study provides a proof-of-concept that atomic force microscopy yields a quantitative read-out of human muscle function from clinical biopsies, and that it may thereby complement current muscular dystrophy diagnosis.
Resumo:
In October 2011 the Task Force Therapeutic Drug Monitoring of the Association for Neuropsychopharmacology and Pharmacopsychiatry (AGNP) published an update (Pharmacopsychiatry 2011, 44: 195-235) of the first version of the consensus paper on therapeutic drug monitoring (TDM) published in 2004. This article summarizes the essential statements to make them accessible to a wider readership in German speaking countries.