200 resultados para Respiration calorimeter.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, we show that a chemical dye, malachite green (MG), which is commonly used in the fish industry as an antifungal, antiparasitic, and antibacterial agent, could effectively kill Candida albicans and non-C. albicans species. We have demonstrated that Candida cells are susceptible to MG at a very low concentration (MIC that reduces growth by 50% [MIC(50)], 100 ng ml(-1)) and that the effect of MG is independent of known antifungal targets, such as ergosterol metabolism and major drug efflux pump proteins. Transcriptional profiling in response to MG treatment of C. albicans cells revealed that of a total of 207 responsive genes, 167 genes involved in oxidative stress, virulence, carbohydrate metabolism, heat shock, amino acid metabolism, etc., were upregulated, while 37 genes involved in iron acquisition, filamentous growth, mitochondrial respiration, etc., were downregulated. We confirmed experimentally that Candida cells exposed to MG resort to a fermentative mode of metabolism, perhaps due to defective respiration. In addition, we showed that MG triggers depletion of intracellular iron pools and enhances reactive oxygen species (ROS) levels. These effects could be reversed by the addition of iron or antioxidants, respectively. We provided evidence that the antifungal effect of MG is exerted through the transcription regulators UPC2 (regulating ergosterol biosynthesis and azole resistance) and STP2 (regulating amino acid permease genes). Taken together, our transcriptome, genetic, and biochemical results allowed us to decipher the multiple mechanisms by which MG exerts its anti-Candida effects, leading to a metabolic shift toward fermentation, increased generation of ROS, labile iron deprivation, and cell necrosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The carbon dioxide production of the chick embryo cultured in vitro has been determined during the first 24 h of post-laying development using a non-invasive conductometric microtechnique. The mean CO2 production of the whole blastoderm (1) increased from 16 nmol/h at laying to 231 nmol/h at early neurulation, (2) became dependent on exogenous glucose and (3) was closely linked to mechanical tension generated in the blastoderm (loosening from vitelline membrane resulted in a decrease of 56%). In our experimental conditions, no significant influence of carbonic anhydrase on the CO2 production has been detected. The value of the respiratory exchange ratio varied from about 3 at pregastrular stages to 1 at neurula stage and CO2 was produced transiently in presence of antimycin A. Such results indicate that the source of CO2 is not exclusively mitochondrial and that the relative proportions of mitochondrial and non-mitochondrial CO2 productions might vary significantly throughout the early development. Our findings confirm that the metabolism of the chick embryo becomes more and more oxidative from laying onwards and suggest that the modifications of metabolism observed during the studied period of development could be associated with functional differentiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper provides an overview on the actual state of acute therapy in patients with ischemic stroke. The discussion focusses on intravenous and intraarterial thrombolysis, antithrombotic therapy, and the treatment of medical and neurological complications, and therapy recommendations are presented. Finally ongoing studies, particularly those concerning thrombolysis with glycoprotein IIb/IIIa receptor blockers and ultrasound-assisted thrombolysis, are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les Suisses sont toujours plus nombreux à se distancer de la religion. Dans sa grande majorité, la population suisse entretient un rapport distant à la religion chrétienne et à la spiritualité. Elle estime cependant que les deux Eglises nationales jouent un rôle important auprès des personnes socialement défavorisée.Telle est la conclusion d'une étude menée dans le cadre du Programme national de recherche « Collectivités religieuses, Etat et société » (PNR 58).En quoi les habitants de Suisse croient-ils ? Jörg Stolz, Judith Könemann, Mallory Schneuwly-Purdie, Thomas Englberger et Michael Krueggeler, sociologues des religions, concluent que la grande majorité de la population helvétique affiche un rapport non pas indifférent ou négatif, mais distant à la religion et à la spiritualité. En d'autres termes, la plupart des habitants de notre pays ne croient pas en rien. Cette population de distants, identifiée ici pour la première fois par une recherche sociologique, va probablement continuer à augmenter à l'avenir, estiment les chercheurs.Toujours plus de personnes sans confession. Selon cette enquête représentative, au cours des dernières années, la part de chrétiens a continué à diminuer au sein de la population : 31% des habitants de Suisse sont catholiques, 32% protestants et 12% adeptes de religions non chrétiennes. C'est du côté des personnes sans confession que la mutation est la plus importante : ceux-ci constituent déjà près de 25% de la population. Mais le fait qu'un individu soit d'une confession donnée ou sans confession ne renseigne pas sur ses pratiques et ses représentations religieuses. Les sans confessions peuvent par exemple croire en Dieu ou pratiquer une spiritualité alternative.Les chercheurs distinguent quatre types de religiosité au sein de la population suisse : les distants (64%), les institutionnels (17%), les laïcs (10%) et les alternatifs (9%). Ces dernières décennies, le groupe formé par les institutionnels a fortement diminué. La proportion d'alternatifs n'a guère évolué, alors que les distants et les laïcs sont aujourd'hui plus nombreux.Les distants ne croient pas en rien. Les distants, qui constituent le groupe le plus important, ne croient pas en rien. Ils disposent de représentations religieuses et spirituelles, mais ces dernières ne jouent pas un rôle important dans leur vie et ils ne les activent que dans des situations exceptionnelles. La plupart d'entre eux sont membres de l'Eglise catholique ou protestante et s'acquittent d'impôts ecclésiastiques, mais leur appartenance confessionnelle ne leur apparaît pas importante. Ils se montrent également distants par rapport aux formes alternatives de religiosité, ainsi que vis-à-vis des personnes hostiles à la religion. Les institutionnels sont membres des deux Eglises nationales ou des Eglises évangéliques libres. Ils entretiennent une foi vivace en un Dieu unique, personnel et transcendant. Les alternatifs cultivent quant à eux des croyances holistiques et ésotériques, pratiquent l'astrologie, des techniques curatives de respiration et de mouvement, ainsi que d'autres rituels.Les laïcs, enfin, sont des personnes auxquelles toutes les formes de religiosité inspirent de l'indifférence, voire un refus. Les hommes plus hostiles à la religion que les femmes. Il est frappant de constater qu'au sein des personnes sans confession, ce ne sont pas les laïcs qui dominent (ils représentent seulement 20%), mais surtout les distants (68%). Les institutionnels affichent un niveau plutôt bas de formation, les distants et les laïcs un niveau moyen, et les alternatifs un haut niveau. Par ailleurs, on rencontre plus souvent des alternatifs chez les femmes (11%) que chez les hommes (4%). A l'inverse, les hommes présentent un taux plus élevé de laïcs (15%) que les femmes (5%).La Suisse est-elle un pays chrétien ?Indépendamment du type de religiosité, une nette majorité de la population considère que les Eglises jouent un rôle important pour les personnes socialement défavorisées. En revanche, ils leur attribuent une moindre importance pour ce qui les concerne personnellement. Les institutionnels sont fermement convaincus que la Suisse est marquée par la chrétienté. A l'inverse, les trois autres groupes - soit la majeure partie de la population - se montrent réservés sur cette question.Les chercheurs ont mené ce sondage représentatif en Suisse romande, alémanique et italienne auprès de 1'229 femmes et hommes. Le sondage a été complété par 73 entretiens semi standardisés et n'a pas pris en compte des adhérents d'autres religions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study was undertaken to determine the delay of extubation attributable to ventilator-associated pneumonia (VAP) in comparison to other complications and complexity of surgery after repair of congenital heart lesions in neonates and children. METHODS: Cohort study in a pediatric intensive care unit of a tertiary referral center. All patients who had cardiac operations during a 22-month period and who survived surgery were eligible (n = 272, median age 1.3 years). Primary outcome was time to successful extubation. Primary variable of interest was VAP Surgical procedures were classified according to complexity. Cox proportional hazards models were calculated to adjust for confounding. Potential confounders comprised other known risk factors for delayed extubation. RESULTS: Median time to extubation was 3 days. VAP occurred in 26 patients (9.6%). The rate of VAP was not associated with complexity of surgery (P = 0.22), or cardiopulmonary bypass (P = 0.23). The adjusted analysis revealed as further factors associated with delayed extubation: other respiratory complications (n = 28, chylothorax, airway stenosis, diaphragm paresis), prolonged inotropic support (n = 48, 17.6%), and the need for secondary surgery (n = 51, 18.8%; e.g., re-operation, secondary closure of thorax). Older age promoted early extubation. The median delay of extubation attributable to VAP was 3.7 days (hazards ratio HR = 0.29, 95% CI 0.18-0.49), exceeding the effect size of secondary surgery (HR = 0.48) and other respiratory complications (HR = 0.50). CONCLUSION: VAP accounts for a major delay of extubation in pediatric cardiac surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial tagging has shown to be a useful magnetic resonance modality for the assessment and quantification of local myocardial function. Many myocardial tagging techniques suffer from a rapid fading of the tags, restricting their application mainly to systolic phases of the cardiac cycle. However, left ventricular diastolic dysfunction has been increasingly appreciated as a major cause of heart failure. Subtraction based slice-following CSPAMM myocardial tagging has shown to overcome limitations such as fading of the tags. Remaining impediments to this technique, however, are extensive scanning times (approximately 10 min), the requirement of repeated breath-holds using a coached breathing pattern, and the enhanced sensitivity to artifacts related to poor patient compliance or inconsistent depths of end-expiratory breath-holds. We therefore propose a combination of slice-following CSPAMM myocardial tagging with a segmented EPI imaging sequence. Together with an optimized RF excitation scheme, this enables to acquire as many as 20 systolic and diastolic grid-tagged images per cardiac cycle with a high tagging contrast during a short period of sustained respiration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acquisition duration of most three-dimensional (3D) coronary magnetic resonance angiography (MRA) techniques is considerably prolonged, thereby precluding breathholding as a mechanism to suppress respiratory motion artifacts. Splitting the acquired 3D volume into multiple subvolumes or slabs serves to shorten individual breathhold duration. Still, problems associated with misregistration due to inconsistent depths of expiration and diaphragmatic drift during sustained respiration remain to be resolved. We propose the combination of an ultrafast 3D coronary MRA imaging sequence with prospective real-time navigator technology, which allows correction of the measured volume position. 3D volume splitting using prospective real-time navigator technology, was successfully applied for 3D coronary MRA in five healthy individuals. An ultrafast 3D interleaved hybrid gradient-echoplanar imaging sequence, including T2Prep for contrast enhancement, was used with the navigator localized at the basal anterior wall of the left ventricle. A 9-cm-thick volume, with in-plane spatial resolution of 1.1 x 2.2 mm, was acquired during five breathholds of 15-sec duration each. Consistently, no evidence of misregistration was observed in the images. Extensive contiguous segments of the left anterior descending coronary artery (48 +/- 18 mm) and the right coronary artery (75 +/- 5 mm) could be visualized. This technique has the potential for screening for anomalous coronary arteries, making it well suited as part of a larger clinical MR examination. In addition, this technique may also be applied as a scout scan, which allows an accurate definition of imaging planes for subsequent high-resolution coronary MRA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Despite the importance of respiration and hyperventilation in anxiety disorders, research on breathing disturbances associated with hyperventilation is rare in the field of music performance anxiety (MPA, also known as stage fright). The only comparable study in this area reported a positive correlation between negative feelings of MPA and hyperventilation complaints during performance. The goals of this study were (a) to extend these previous findings to the period before performance, (b) to test whether a positive correlation also exists between hyperventilation complaints and the experience of stage fright as a problem, (c) to investigate instrument-specific symptom reporting, and (d) to confirm gender differences in negative feelings of MPA and hyperventilation complaints reported in other studies. Methods: We assessed 169 university students of classical music with a questionnaire comprising: the State-Trait Anxiety Inventory for negative feelings of MPA, the Nijmegen Questionnaire for hyperventilation complaints, and a single item for the experience of stage fright as a problem. Results: We found a significant positive correlation between hyperventilation complaints and negative feelings of MPA before performance and a significant positive correlation between hyperventilation complaints and the experience of stage fright as a problem. Wind musicians/singers reported a significantly higher frequency of respiratory symptoms than other musicians. Furthermore, women scored significantly higher on hyperventilation complaints and negative feelings of MPA. Conclusion: These results further the findings of previous reports by suggesting that breathing disturbances associated with hyperventilation may play a role in MPA prior to going on stage. Experimental studies are needed to confirm whether hyperventilation complaints associated with negative feelings of MPA manifest themselves at the physiological level. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The overall thermogenic response to food intake measured over a whole day in 20 young nondiabetic obese women (body fat mean +/- SEM: 38.6 +/- 0.7%), was compared with that obtained in eight nonobese control women (body fat: 24.7 +/- 0.9%). The energy expenditure of the subjects was continuously measured over 24 h with a respiration chamber, and the spontaneous activity was assessed by a radar system. A new approach was used to obtain the integrated thermogenic response to the three meals ingested over the day (from 8:30 AM to 10:30 PM). This method allows to subtract the energy expended for physical activity from total energy expenditure and to calculate the integrated dietary-induced thermogenesis as the difference between the energy expended without physical activity and basal metabolic rate. The thermogenic response to the three meals (expressed in percentage of the total energy ingested) was found to be blunted in obese women (8.7 +/- 0.8%) as compared with that of controls (14.8 +/- 1.1%). There was an inverse correlation between the percentage body fat and the diet-induced thermogenesis (r = -0.61, p less than 0.001). In addition, the relative increase in diurnal urinary norepinephrine excretion was lower in obese than in the control subjects. It is concluded that a low overall thermogenic response to feeding may be a contributing factor for energy storage in some obese subjects; a blunted response of the sympathetic nervous system could explain this low thermogenic response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of nursing on the duration of weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease. DESIGN: Data were collected prospectively over a 1-yr period (study year) and compared with previously collected prospective data recorded in our chronic obstructive pulmonary disease database during a 5-yr period. SETTING: The medical intensive care unit (ICU) of a university hospital. PATIENTS: Eighty-seven patients with chronic obstructive pulmonary disease. Fifteen patients had chronic obstructive pulmonary disease that required mechanical ventilation for acute exacerbation of their disease (study year), and 72 were patients with chronic obstructive pulmonary disease from the previously collected data. INTERVENTIONS: The ICU course (duration of mechanical ventilation, mortality) was recorded, as well as several respiratory parameters (pulmonary function tests and arterial blood gases in stable conditions, and nutritional status), and they were compared with an "index of nursing." MEASUREMENTS AND MAIN RESULTS: We developed an "index of nursing", comparing the effective workforce of the nurses (number and qualifications) with the ideal workforce required by the number of patients and the severity of their diseases. A value of 1.0 represented a perfect match between the needed and the effectively present nurses, whereas a lesser value signified a diminished available workforce. This index was compared with the complications and duration of weaning from mechanical ventilation. During the first 5 yrs, the duration of mechanical ventilation increased progressively from 7.3 +/- 8.0 to 38.2 +/- 25.8 days (p = .006). A significant inverse correlation between the duration of mechanical ventilation and the nursing index (p = .025) was found. In the sixth comparative year, the number of nurses increased (nursing index = 1.05) and the duration of mechanical ventilation decreased to 9.9 +/- 13 days (p < .001, yr 5 vs. yr 6). CONCLUSIONS: The quality of nursing appears to be a measurable and critical factor in the weaning from mechanical ventilation of patients with chronic obstructive pulmonary disease. Below a threshold in the available workforce of ICU nurses, the weaning duration of patients with chronic obstructive pulmonary disease increases dramatically. Therefore, very close attention should be given to the education and number of ICU nurses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paralysis with pancuronium bromide is used in newborn infants to facilitate ventilatory support during respiratory failure. Changes in lung mechanics have been attributed to paralysis. The aim of this study was to examine whether or not paralysis per se has an influence on the passive respiratory mechanics, resistance (Rrs) and compliance (Crs) of the respiratory system in newborn infants. In 30 infants with acute respiratory failure, Rrs was measured during paralysis with pancuronium bromide and after stopping pancuronium bromide (group A). Rrs was also measured in an additional 10 ventilated infants in a reversed fashion (group B): Rrs was measured first in nonparalysed infants and then they were paralysed, mainly for diagnostic procedures, and the Rrs measurement repeated. As Rrs is highly dependent on lung volume, several parameters, that depend directly on lung volume were recorded: inspiratory oxygen fraction (FI,O2), arterial oxygen tension/alveolar oxygen tension (a/A) ratio and volume above functional residual capacity (FRC). In group A, the Rrs was not different during (0.236+/-0.09 cmH2O x s x mL(-1)) and after (0.237+/-0.07 cmH2O x s x mL(-1)) paralysis. Also, in group B, Rrs did not change (0.207+/-0.046 versus 0.221+/-0.046 cm x s x mL(-1) without versus with pancuronium bromide). FI,O2, a/A ratio and volume above FRC remained constant during paralysis. These data demonstrate that paralysis does not influence the resistance of the total respiratory system in ventilated term and preterm infants when measured at comparable lung volumes.