132 resultados para RADIATION HAZARDS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Question: Outdoor occupational exposure could be associated with important cumulative and intense exposure to ultraviolet (UV) solar radiation. Such exposure would increase risk of skin cancer. However, little information exists on jobs associated with intense UV exposure. The objective of this study was to characterise occupational UV exposure in a representative sample in France. Methods: A population-based survey was conducted in May-June 2012 through computer-assisted telephonic interviews in population 25 to 69 years of age. Individual UV irradiation was computed with declared time and place of residence matched to UV records from satellite measurement (Eurosun project). We analysed factors influencing exposure to UV (annual average and seasonal peak). Results: A total of 1442 individuals declared having an occupational exposure to UV which represents 18% of population aged 25 to 69 years. Outdoor workers were more frequently men (58%), aged 40-54 (43%), with a phototype III or IV (69%). Occupations associated with highest UV exposure were: construction workers (annual daily average 62.8 Joules/m2), gardeners (62.6), farmers (52.8), culture/art/social sciences workers (52.0) and transport workers/mail carriers (49.5). The maximum of UVA exposure was found for occupation with a strong seasonality of exposure: culture, art or social sciences works (98.1 Joules/m2), construction works (97.2), gardening (96.7) and farming (95.0). Significant factors associated with high occupational UV exposure were gender (men vs. women: 53.6 vs. 42.6), phototype (IV vs. I: 51.9 vs. 45.5) and taking lunch outdoors (always vs. never: 59.8 vs. 48.6). Conclusion: Our study showed that some occupations were associated with particularly intense UV exposure such as farmers, gardeners, construction workers. Other unexpected occupations were also associated with high UV exposure such as transport workers, mail carriers and culture/art/social sciences workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article is to present an overview of salient issues of exposure, characterisation and hazard assessment of nanomaterials as they emerged from the consensus-building of experts undertaken within the four year European Commission coordination project NanoImpactNet. The approach adopted is to consolidate and condense the findings and problem-identification in such a way as to identify knowledge-gaps and generate a set of interim recommendations of use to industry, regulators, research bodies and funders. The categories of recommendation arising from the consensual view address: significant gaps in vital factual knowledge of exposure, characterisation and hazards; the development, dissemination and standardisation of appropriate laboratory protocols; address a wide range of technical issues in establishing an adequate risk assessment platform; the more efficient and coordinated gathering of basic data; greater inter-organisational cooperation; regulatory harmonization; the wider use of the life-cycle approaches; and the wider involvement of all stakeholders in the discussion and solution-finding efforts for nanosafety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to assess feasibility and efficacy of weekly concomitant boost accelerated postoperative radiation therapy (PORT) with concomitant chemotherapy (CT) in patients with locally advanced head and neck cancer (LAHNC). METHODS AND MATERIALS: Conformal or intensity-modulated 66-Gy RT was performed in 5.5 weeks in 40 patients. Cisplatin was given at days 1, 22, and 43. Median follow-up was 36 months. RESULTS AND DISCUSSION: Grade 3 mucositis, dysphagia, and erythema was observed in ten (25%), nine (23%), and six (13%) patients, respectively. Grade 3 or more anemia was observed in two (6%) patients, and leukopenia in five (13%) patients. No grade 3 or 4 thrombocytopenia was observed. Grade 3 nephrotoxicity was observed in one patient (3%). No treatment-related mortality was observed. Grade 2 or more xerostomia and edema were observed in ten (25%) and one (3%) patient, respectively. Locoregional relapse occurred in eight patients, and seven patients developed distant metastases. Median time to locoregional relapse was 6 months. Three-year overall, disease-free survival, and locoregional control rates were 63%, 62%, and 81%, respectively. Multivariate analysis revealed that the only prognostic factor was nodal status. CONCLUSION: Reducing overall treatment time using accelerated PORT/CT by weekly concomitant boost (six fractions per week) combined with concomitant cisplatin CT is easily feasible with acceptable morbidity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In this study, we investigated the mechanisms by which temozolomide enhances radiation response in glioblastoma cells. EXPERIMENTAL DESIGN: Using a panel of four primary human glioblastoma cell lines with heterogeneous O(6)-methylguanine-DNA methyltransferase (MGMT) protein expression, normal human astrocytes, and U87 xenografts, we investigated (a) the relationship of MGMT status with efficacy of temozolomide-based chemoradiation using a panel of in vitro and in vivo assays; (b) underlying mechanisms by which temozolomide enhances radiation effect in glioblastoma cells; and (c) strategies to overcome resistance to radiation + temozolomide. RESULTS: Temozolomide enhances radiation response most effectively in glioblastomas without detectable MGMT expression. On concurrent radiation + temozolomide administration in MGMT-negative glioblastomas, there seems to be decreased double-strand DNA (dsDNA) repair capacity and enhanced dsDNA damage compared either with radiation alone or with sequentially administered temozolomide. Our data suggest that O(6)-benzylguanine can enhance the antitumor effects of concurrent radiation + temozolomide in MGMT-positive cells by enhancing apoptosis and the degree of dsDNA damage. O(6)-Benzylguanine was most effective when administered concurrently with radiation + temozolomide and had less of an effect when administered with temozolomide in the absence of radiation or when administered sequentially with radiation. Our in vivo data using U87 xenografts confirmed our in vitro findings. CONCLUSIONS: The present study shows that temozolomide enhances radiation response most effectively in MGMT-negative glioblastomas by increasing the degree of radiation-induced double-strand DNA damage. In MGMT-positive glioblastomas, depletion of MGMT by the addition of O(6)-benzylguanine significantly enhances the antitumor effect of concurrent radiation + temozolomide. These are among the first data showing mechanisms of synergy between radiation and temozolomide and the effect of MGMT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: 125I-iododeoxyuridine is a potential Auger radiation therapy agent. Its incorporation in DNA of proliferating cells is enhanced by fluorodeoxyuridine. Here, we evaluated therapeutic activities of 125I-iododeoxyuridine in an optimized fluorodeoxyuridine pre-treatment inducing S-phase synchronization. Methods: After S-phase synchronization by fluorodeoxyuridine, cells were treated with 125I-iododeoxyuridine. Apoptosis analysis and S-phase synchronization were studied by flow cytometry. Cell survival was determined by colony-forming assay. Based on measured growth parameters, the number of decays per cell that induced killing was extrapolated. Results: Treatment experiments showed that 72 to 91% of synchronized cells were killed after 0.8 and 8 kBq/ml 125I-iododeoxyuridine incubation, respectively. In controls, only 8 to 38% of cells were killed by corresponding 125I-iododeoxyuridine activities alone and even increasing the activity to 80 kBq/ml gave only 42 % killing. Duplicated treatment cycles or repeated fluorodeoxyuridine pre-treatment allowed enhancing cell killing to >95 % at 8 kBq/ml 125I-iododeoxyuridine. About 50 and 160 decays per S-phase cells in controls and S-phase synchronization, respectively, were responsible for the observed cell killing at 0.8 kBq/ml radio-iododeoxyuridine. Conclusion: These data show the successful application of fluorodeoxyuridine that provided increased 125I-iododeoxyuridine Auger radiation cell killing efficacy through S-phase synchronization and high DNA incorporation of radio-iododeoxyuridine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the association between exposure to radio-frequency electromagnetic fields (RF-EMFs) from broadcast transmitters and childhood cancer. First, we conducted a time-to-event analysis including children under age 16 years living in Switzerland on December 5, 2000. Follow-up lasted until December 31, 2008. Second, all children living in Switzerland for some time between 1985 and 2008 were included in an incidence density cohort. RF-EMF exposure from broadcast transmitters was modeled. Based on 997 cancer cases, adjusted hazard ratios in the time-to-event analysis for the highest exposure category (>0.2 V/m) as compared with the reference category (<0.05 V/m) were 1.03 (95% confidence interval (CI): 0.74, 1.43) for all cancers, 0.55 (95% CI: 0.26, 1.19) for childhood leukemia, and 1.68 (95% CI: 0.98, 2.91) for childhood central nervous system (CNS) tumors. Results of the incidence density analysis, based on 4,246 cancer cases, were similar for all types of cancer and leukemia but did not indicate a CNS tumor risk (incidence rate ratio = 1.03, 95% CI: 0.73, 1.46). This large census-based cohort study did not suggest an association between predicted RF-EMF exposure from broadcasting and childhood leukemia. Results for CNS tumors were less consistent, but the most comprehensive analysis did not suggest an association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the radiation exposure of the Swiss population to interventional procedures. A nationwide survey was conducted in Switzerland. The annual effective dose per capita due to interventional procedures was found to be 0.14 mSv, corresponding to 12% of the total dose. Coronary angiography and percutaneous coronary interventions were found to be the most frequent and the most irradiating interventional procedures, accounting for 52% of the total examination frequency and 64% of the dose delivered to the population. Switzerland stands at the same level as other countries in terms of effective dose per capita due to interventional radiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A discussion on the importance and pathogenesis of radiation-induced pneumonitis and fibrosis is provided, with a special focus on the role of the immune system. The need to understand this interaction is highlighted in view of emerging therapeutic potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.