368 resultados para Prevention tool


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attitudinal and behavioural change among gay men in Switzerland was measured between 1987 and 1990 to evaluate the effectiveness of AIDS prevention activities. The methodology used included a self-administered questionnaire published in Swiss gay magazines and distributed by gay organizations (N = 795 in 1987, N = 720 in 1990) and in-depth interviews with men recruited through advertisements and through the questionnaire (N = 42 in 1987, N = 24 in 1990). The two independent sampling procedures yielded similar samples with regard to socio-demographic characteristics, allowing comparisons to be made between the 1987 and 1990 data. Personal confrontation with AIDS (knowing someone who is HIV-positive, or who is ill or dead from AIDS) increased significantly during the period but more adequate ways of coping developed. Behavioural change towards safer sex began well before the first study. The majority of responding homosexuals have adapted their sexual behaviour to the new situation created by AIDS and generally maintain a protective behaviour. However, "exceptions" (condom rupture or episodes of non-protection) are not infrequent and should deserve more attention. Three indicators of sexual behaviour (number of sexual partners, anal sex and use of condom and oral sex with ejaculation), reported for the last 3 months before each study, exhibit few changes between 1987 and 1990: number of partners remained stable, unprotected oral sex decreased. Anal sex slightly increased, the use of condoms remaining stable. Sixty-seven percent of the sample knew their serostatus in 1990 (57% in 1987), and 13% of these stated that they were HIV+ (14% in 1987).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE: The 2013 American College of Cardiology/American Heart Association (ACC/AHA) guidelines introduced a prediction model and lowered the threshold for treatment with statins to a 7.5% 10-year hard atherosclerotic cardiovascular disease (ASCVD) risk. Implications of the new guideline's threshold and model have not been addressed in non-US populations or compared with previous guidelines. OBJECTIVE: To determine population-wide implications of the ACC/AHA, the Adult Treatment Panel III (ATP-III), and the European Society of Cardiology (ESC) guidelines using a cohort of Dutch individuals aged 55 years or older. DESIGN, SETTING, AND PARTICIPANTS: We included 4854 Rotterdam Study participants recruited in 1997-2001. We calculated 10-year risks for "hard" ASCVD events (including fatal and nonfatal coronary heart disease [CHD] and stroke) (ACC/AHA), hard CHD events (fatal and nonfatal myocardial infarction, CHD mortality) (ATP-III), and atherosclerotic CVD mortality (ESC). MAIN OUTCOMES AND MEASURES: Events were assessed until January 1, 2012. Per guideline, we calculated proportions of individuals for whom statins would be recommended and determined calibration and discrimination of risk models. RESULTS: The mean age was 65.5 (SD, 5.2) years. Statins would be recommended for 96.4% (95% CI, 95.4%-97.1%; n = 1825) of men and 65.8% (95% CI, 63.8%-67.7%; n = 1523) of women by the ACC/AHA, 52.0% (95% CI, 49.8%-54.3%; n = 985) of men and 35.5% (95% CI, 33.5%-37.5%; n = 821) of women by the ATP-III, and 66.1% (95% CI, 64.0%-68.3%; n = 1253) of men and 39.1% (95% CI, 37.1%-41.2%; n = 906) of women by ESC guidelines. With the ACC/AHA model, average predicted risk vs observed cumulative incidence of hard ASCVD events was 21.5% (95% CI, 20.9%-22.1%) vs 12.7% (95% CI, 11.1%-14.5%) for men (192 events) and 11.6% (95% CI, 11.2%-12.0%) vs 7.9% (95% CI, 6.7%-9.2%) for women (151 events). Similar overestimation occurred with the ATP-III model (98 events in men and 62 events in women) and ESC model (50 events in men and 37 events in women). The C statistic was 0.67 (95% CI, 0.63-0.71) in men and 0.68 (95% CI, 0.64-0.73) in women for hard ASCVD (ACC/AHA), 0.67 (95% CI, 0.62-0.72) in men and 0.69 (95% CI, 0.63-0.75) in women for hard CHD (ATP-III), and 0.76 (95% CI, 0.70-0.82) in men and 0.77 (95% CI, 0.71-0.83) in women for CVD mortality (ESC). CONCLUSIONS AND RELEVANCE: In this European population aged 55 years or older, proportions of individuals eligible for statins differed substantially among the guidelines. The ACC/AHA guideline would recommend statins for nearly all men and two-thirds of women, proportions exceeding those with the ATP-III or ESC guidelines. All 3 risk models provided poor calibration and moderate to good discrimination. Improving risk predictions and setting appropriate population-wide thresholds are necessary to facilitate better clinical decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a prospective nonrandomized study, using each baby as his or her own control, we compared intracranial pressure (anterior fontanel pressure as measured with the Digilab pneumotonometer), cerebral perfusion pressure, BP, heart rate, transcutaneous Po2, and transcutaneous Pco2 before, during, and after endotracheal suctioning, with and without muscle paralysis, in 28 critically ill preterm infants with respiratory distress syndrome. With suctioning, there was a small but significant increase in intracranial pressure in paralyzed patients (from 13.7 [mean] +/- 4.4 mm Hg [SD] to 15.8 +/- 5.2 mm Hg) but a significantly larger (P less than .001) increase when they were not paralyzed (from 12.5 +/- 3.6 to 28.5 +/- 8.3 mm Hg). Suctioning led to a slight increase in BP with (from 45.3 +/- 9.1 to 48.0 +/- 8.7 mm Hg) and without muscle paralysis (from 45.1 +/- 9.4 to 50.0 +/- 11.7 mm Hg); but there was no significant difference between the two groups. The cerebral perfusion pressure in paralyzed infants did not show any significant change before, during, and after suctioning (31.5 +/- 9.1 mm Hg before v 32.0 +/- 8.7 mm Hg during suctioning), but without muscle paralysis cerebral perfusion pressure decreased (P less than .001) from 32.8 +/- 9.7 to 21.3 +/- 13.1 mm Hg. Suctioning induced a slight decrease in mean heart rate and transcutaneous Po2, but pancuronium did not alter these changes. There was no statistical difference in transcutaneous Pco2 before, during, and after suctioning with and without muscle paralysis.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metabolic problems lead to numerous failures during clinical trials, and much effort is now devoted to developing in silico models predicting metabolic stability and metabolites. Such models are well known for cytochromes P450 and some transferases, whereas less has been done to predict the activity of human hydrolases. The present study was undertaken to develop a computational approach able to predict the hydrolysis of novel esters by human carboxylesterase hCES2. The study involved first a homology modeling of the hCES2 protein based on the model of hCES1 since the two proteins share a high degree of homology (congruent with 73%). A set of 40 known substrates of hCES2 was taken from the literature; the ligands were docked in both their neutral and ionized forms using GriDock, a parallel tool based on the AutoDock4.0 engine which can perform efficient and easy virtual screening analyses of large molecular databases exploiting multi-core architectures. Useful statistical models (e.g., r (2) = 0.91 for substrates in their unprotonated state) were calculated by correlating experimental pK(m) values with distance between the carbon atom of the substrate's ester group and the hydroxy function of Ser228. Additional parameters in the equations accounted for hydrophobic and electrostatic interactions between substrates and contributing residues. The negatively charged residues in the hCES2 cavity explained the preference of the enzyme for neutral substrates and, more generally, suggested that ligands which interact too strongly by ionic bonds (e.g., ACE inhibitors) cannot be good CES2 substrates because they are trapped in the cavity in unproductive modes and behave as inhibitors. The effects of protonation on substrate recognition and the contrasting behavior of substrates and products were finally investigated by MD simulations of some CES2 complexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cet article propose une mise à jour des recommandations pour le bilan de santé et la prévention primaire et secondaire de nombreuses maladies cardiovasculaires et oncologiques. Les nouveautés pour le dépistage des cancers concernent essentiellement les cancers colorectal, du poumon et de la prostate. Pour la prévention des maladies cardiovasculaires, le dépistage de la sténose de l'artère carotidienne n'est toujours pas recommandé. Les preuves de la littérature sont insuffisantes pour recommander le dépistage de l'artériopathie coronarienne ou périphérique chez les patients asymptomatiques. Le partage de l'information et de la décision entre le médecin et le patient est à privilégier lorsqu'il existe une incertitude quant à l'efficacité d'une intervention. This article provides an update on the recommendations for the routine check-up and the primary and secondary prevention of cancer and cardiovascular disease. Changes for cancer screening affect mainly colorectal, lung and prostate cancers. In the area of cardiovascular disease prevention, screening for carotid artery stenosis is still not recommended. The current evidence is insufficient to recommend screening for coronary heart disease or peripheral artery disease in asymptomatic patients. Shared information and decision making between physician and patient is recommended when there is uncertainty regarding the effectiveness of an intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protein energy wasting (PEW) is common in patients with chronic kidney disease (CKD) and is associated with adverse clinical outcomes, especially in individuals receiving maintenance dialysis therapy. A multitude of factors can affect the nutritional and metabolic status of CKD patients requiring a combination of therapeutic maneuvers to prevent or reverse protein and energy depletion. These include optimizing dietary nutrient intake, appropriate treatment of metabolic disturbances such as metabolic acidosis, systemic inflammation, and hormonal deficiencies, and prescribing optimized dialytic regimens. In patients where oral dietary intake from regular meals cannot maintain adequate nutritional status, nutritional supplementation, administered orally, enterally, or parenterally, is shown to be effective in replenishing protein and energy stores. In clinical practice, the advantages of oral nutritional supplements include proven efficacy, safety, and compliance. Anabolic strategies such as anabolic steroids, growth hormone, and exercise, in combination with nutritional supplementation or alone, have been shown to improve protein stores and represent potential additional approaches for the treatment of PEW. Appetite stimulants, anti-inflammatory interventions, and newer anabolic agents are emerging as novel therapies. While numerous epidemiological data suggest that an improvement in biomarkers of nutritional status is associated with improved survival, there are no large randomized clinical trials that have tested the effectiveness of nutritional interventions on mortality and morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amoebae are unicellular protozoan present worldwide in several environments mainly feeding on bacteria. Some of them, the amoebae-resistant bacteria (ARBs), have evolved mechanisms to survive and replicate inside amoebal species. These mainly include legionella, mycobacteria and Chlamydia-related bacteria. Amoebae can provide a replicative niche, can act as reservoir for bacteria whereas the cystic form can protect the internalized bacteria. Moreover, the amoebae represent a Trojan horse for ARBs to infect animals. The long interaction between amoebae and bacteria has likely selected for bacterial virulence traits leading to the adaptation towards an intracellular lifestyle, and some ARBs have acquired the ability to infect mammals. This review intends to highlight the important uses of amoebae in several fields in microbiology by describing the main tools developed using amoebal cells. First, amoebae such as Acanthamoeba are used to isolate and discover new intracellular bacterial species by two main techniques: the amoebal co-culture and the amoebal enrichment. In the second part, taking Waddlia chondrophila as example, we summarize some important recent applications of amoebae to discover new bacterial virulence factors, in particular thanks to the amoebal plaque assay. Finally, the genetically tractable Dictyostelium discoideum is used as a model organism to study host-pathogen interactions, in particular with the development of several approaches to manipulate its genome that allowed the creation of a wide range of mutated strains largely shared within the Dictyostelium community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to propose a methodology allowing a detailed characterization of body sit-to-stand/stand-to-sit postural transition. Parameters characterizing the kinematics of the trunk movement during sit-to-stand (Si-St) postural transition were calculated using one initial sensor system fixed on the trunk and a data logger. Dynamic complexity of these postural transitions was estimated by fractal dimension of acceleration-angular velocity plot. We concluded that this method provides a simple and accurate tool for monitoring frail elderly and to objectively evaluate the efficacy of a rehabilitation program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Les améliorations méthodologiques des dernières décennies ont permis une meilleure compréhension de la motilité gastro-intestinale. Il manque toutefois une méthode qui permette de suivre la progression du chyme le long du tube gastro-intestinal. Pour permettre l'étude de la motilité de tout le tractus digestif humain, une nouvelle technique, peu invasive, a été élaborée au Département de Physiologie, en collaboration avec l'EPFL. Appelée "Magnet Tracking", la technique est basée sur la détection du champ magnétique généré par des matériaux ferromagnétiques avalés. A cet usage, une pilule magnétique, une matrice de capteurs et un logiciel ont été développés. L'objet de ce travail est de démontrer la faisabilité d'un examen de la motilité gastro-intestinale chez l'Homme par cette méthode. L'aimant est un cylindre (ø 6x7 mm, 0.2 cm3) protégé par une gaine de silicone. Le système de mesure est constitué d'une matrice de 4x4 capteurs et d'un ordinateur portable. Les capteurs fonctionnent sur l'effet Hall. Grâce à l'interface informatique, l'évolution de la position de l'aimant est suivie en temps réel à travers tout le tractus digestif. Sa position est exprimée en fonction du temps ou reproduite en 3-D sous forme d'une trajectoire. Différents programmes ont été crées pour analyser la dynamique des mouvements de l'aimant et caractériser la motilité digestive. Dix jeunes volontaires en bonne santé ont participé à l'étude. L'aimant a été avalé après une nuit de jeûne et son séjour intra digestif suivi pendant 2 jours consécutifs. Le temps moyen de mesure était de 34 heures. Chaque sujet a été examiné une fois sauf un qui a répété sept fois l'expérience. Les sujets restaient en décubitus dorsal, tranquilles et pouvaient interrompre la mesure s'ils le désiraient. Ils sont restés à jeûne le premier jour. L'évacuation de l'aimant a été contrôlée chez tous les sujets. Tous les sujets ont bien supporté l'examen. Le marqueur a pu être détecté de l'oesophage au rectum. La trajectoire ainsi constituée représente une conformation de l'anatomie digestive : une bonne superposition de celle-ci à l'anatomie est obtenue à partir des images de radiologie conventionnelle (CT-scan, lavement à la gastrografine). Les mouvements de l'aimant ont été caractérisés selon leur périodicité, leur amplitude ou leur vitesse pour chaque segment du tractus digestif. Ces informations physiologiques sont bien corrélées à celles obtenues par des méthodes établies d'étude de la motilité gastro-intestinale. Ce travail démontre la faisabilité d'un examen de la motilité gastro-intestinal chez l'Homme par la méthode de Magnet Tracking. La technique fournit les données anatomiques et permet d'analyser en temps réel la dynamique des mouvements du tube digestif. Cette méthode peu invasive ouvre d'intéressantes perspectives pour l'étude de motilité dans des conditions physiologiques et pathologiques. Des expériences visant à valider cette approche en tant que méthode clinique sont en voie de réalisation dans plusieurs centres en Suisse et à l'étranger. SUMMARY Methodological improvements realised over the last decades have permitted a better understanding of gastrointestinal motility. Nevertheless, a method allowing a continuous following of lumina' contents is still lacking. In order to study the human digestive tract motility, a new minimally invasive technique was developed at the Department of Physiology in collaboration with Swiss Federal Institute of Technology. The method is based on the detection of magnetic field generated by swallowed ferromagnetic materials. The aim of our work was to demonstrate the feasibility of this new approach to study the human gastrointestinal motility. The magnet used was a cylinder (ø6x7mm, 0.2 cm3) coated with silicon. The magnet tracking system consisted of a 4x4 matrix of sensors based on the Hall effect Signals from the sensors were digitised and sent to a laptop computer for processing and storage. Specific software was conceived to analyse in real time the progression of the magnet through the gastrointestinal tube. Ten young and healthy volunteers were enrolled in the study. After a fasting period of 12 hours, they swallowed the magnet. The pill was then tracked for two consecutive days for 34 hours on average. Each subject was studied once except one who was studied seven times. Every subject laid on his back for the entire experiment but could interrupt it at anytime. Evacuation of the magnet was controlled in all subjects. The examination was well tolerated. The pill could be followed from the esophagus to the rectum. The trajectory of the magnet represented a "mould" of the anatomy of the digestive tube: a good superimposition with radiological anatomy (gastrografin contrast and CT) was obtained. Movements of the magnet were characterized by periodicity, velocity, and amplitude of displacements for every segment of the digestive tract. The physiological information corresponded well to data from current methods of studying gastrointestinal motility. This work demonstrates the feasibility of the new approach in studies of human gastrointestinal motility. The technique allows to correlate in real time the dynamics of digestive movements with the anatomical data. This minimally invasive method is ready for studies of human gastrointestinal motility under physiological as well as pathological conditions. Studies aiming at validation of this new approach as a clinically relevant tool are being realised in several centres in Switzerland and abroad. Abstract: A new minimally invasive technique allowing for anatomical mapping and motility studies along the entire human digestive system is presented. The technique is based on continuous tracking of a small magnet progressing through the digestive tract. The coordinates of the magnet are calculated from signals recorded by 16 magnetic field sensors located over the abdomen. The magnet position, orientation and trajectory are displayed in real time. Ten young healthy volunteers were followed during 34 h. The technique was well tolerated and no complication was encountered, The information obtained was 3-D con-figuration of the digestive tract and dynamics of the magnet displacement (velocity, transit time, length estimation, rhythms). In the same individual, repea-ted examination gave very reproducible results. The anatomical and physiological information obtained corresponded well to data from current methods and imaging. This simple, minimally invasive technique permits examination of the entire digestive tract and is suitable for both research and clinical studies. In combination with other methods, it may represent a useful tool for studies of Cl motility with respect to normal and pathological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: La formation des atélectasies durant l'induction de l'anesthésie générale est plus importante chez le patient obèse morbide. Nous avons démontré dans des travaux de recherche antérieurs que l'utilisation de la PEEP (Pression Positive en Fin d'Expiration) durant l'induction de l'anesthésie prévient la formation d'atélectasies chez des patients non obèses. Par conséquent, nous voulions étudier l'efficacité de la pression positive en fin d'expiration chez le patient obèse morbide dans la prévention de la formation d'atélectasies. Nous avons fait une étude de 23 patients obèses morbides (BMI > 35 kg / m2) dans 2 groupes. Dans le groupe utilisant la pression positive en fin d'expiration, les patients respiraient 100% d'oxygène pendant 5 minutes par l'intermédiaire d'un masque facial type CPAP avec une pression de 10 cm H20. Après l'induction de l'anesthésie, nous avons ventilé les patients au masque facial avec une PEEP de 10 cm H20. Dans le groupe de contrôle, nous avons procédé au même type d'induction sans utiliser la pression positive en fin d'expiration. La surface de poumon atélectatique a été évaluée par tomographie (CT scann). L'étude des échanges gazeux se faisait à 2 reprises, à partir de gazométries réalisées juste avant l'induction de l'anesthésie puis juste après l'intubation. Après l'induction de l'anesthésie et l'intubation, les patients du groupe de contrôle présentaient une quantité d'atélectasies plus importante que les patients du groupe où la PEEP avait été utilisée (10.4% + 4.8% dans le groupe de contrôle versus 1.3% dans le groupe utilisant la pression positive en fin d'expiration p < 0.001). Après l'intubation, en présence d'une fraction inspirée en oxygène à 100%, la Pa02 était significativement supérieure dans le groupe ayant utilisé la pression positive en fin d'expiration en comparaison avec le groupe de contrôle (respectivement 457 ± 130 mmHg versus 315 ± 100 mmHg). Nous avons conclu que chez le patient obèse morbide, le recours à la pression positive en fin d'expiration lors de l'induction de l'anesthésie permet de prévenir largement la formation d'atélectasies et s'accompagne d'une meilleure oxygénation. Abstract: Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (b ody mass index >35 kg/m2) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H20 and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H2O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% -± 4.8% in control group versus 1.7% ± 1.3% in PEEP group; P <0.001). After in.tubation with a fraction of inspired oxygen of 1.0, Pao, was significantly higher in the PEEP group compared with the control group (457 ±- 130 mm Hg versus 315 ± 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.