105 resultados para Plasma concentration


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The role of busulfan (Bu) metabolites in the adverse events seen during hematopoietic stem cell transplantation and in drug interactions is not explored. Lack of availability of established analytical methods limits our understanding in this area. The present work describes a novel gas chromatography-tandem mass spectrometric assay for the analysis of sulfolane (Su) in plasma of patients receiving high-dose Bu. Su and Bu were extracted from a single 100 μL plasma sample by liquid-liquid extraction. Bu was separately derivatized with 2,3,5,6-tetrafluorothiophenolfluorinated agent. Mass spectrometric detection of the analytes was performed in the selected reaction monitoring mode on a triple quadrupole instrument after electronic impact ionization. Bu and Su were analyzed with separate chromatographic programs, lasting 5 min each. The assay for Su was found to be linear in the concentration range of 20-400 ng/mL. The method has satisfactory sensitivity (lower limit of quantification, 20 ng/mL) and precision (relative standard deviation less than 15 %) for all the concentrations tested with a good trueness (100 ± 5 %). This method was applied to measure Su from pediatric patients with samples collected 4 h after dose 1 (n = 46), before dose 7 (n = 56), and after dose 9 (n = 54) infusions of Bu. Su (mean ± SD) was detectable in plasma of patients 4 h after dose 1, and higher levels were observed after dose 9 (249.9 ± 123.4 ng/mL). This method may be used in clinical studies investigating the role of Su on adverse events and drug interactions associated with Bu therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The antifungal agent fluconazole (FLC) is widely used in clinical practice. Monitoring FLC levels is useful in complicated clinical settings and in experimental infection models. A bioassay using Candida pseudotropicalis, a simple and cost-effective method, is validated only for FLC levels ranging from 5 to 40 mg/liter. An extension of the analytical range is needed to cover most yeast MICs. A new bioassay in RPMI agar containing methylene blue was developed using C. albicans DSY1024, a mutant rendered hypersusceptible to FLC constructed by the deletion of the multidrug efflux transporter genes CDR1, CDR2, CaMDR1, and FLU1. Reproducible standard curves were obtained with FLC concentrations in plasma ranging from 1 to 100 mg/liter (quadratic regression coefficient > 0.997). The absolute sensitivity was 0.026 microg of FLC. The method was internally validated according to current guidelines for analytical method validation. Both accuracy and precision lied in the required +/-15% range. FLC levels measured by bioassay and by high-performance liquid chromatography (HPLC) performed with 62 plasma samples from humans and rats showed a strong correlation (coefficients, 0.979 and 0.995, respectively; percent deviations of bioassay from HPLC values, 0.44% +/- 15.31% and 2.66% +/- 7.54%, respectively). In summary, this newly developed bioassay is sensitive, simple, rapid, and inexpensive. It allows nonspecialized laboratories to determine FLC levels in plasma to within the clinically relevant concentration range and represents a useful tool for experimental treatment models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: Total imatinib concentrations are currently measured for the therapeutic drug monitoring of imatinib, whereas only free drug equilibrates with cells for pharmacological action. Due to technical and cost limitations, routine measurement of free concentrations is generally not performed. In this study, free and total imatinib concentrations were measured to establish a model allowing the confident prediction of imatinib free concentrations based on total concentrations and plasma proteins measurements. METHODS: One hundred and fifty total and free plasma concentrations of imatinib were measured in 49 patients with gastrointestinal stromal tumours. A population pharmacokinetic model was built up to characterize mean total and free concentrations with inter-patient and intrapatient variability, while taking into account α1 -acid glycoprotein (AGP) and human serum albumin (HSA) concentrations, in addition to other demographic and environmental covariates. RESULTS: A one compartment model with first order absorption was used to characterize total and free imatinib concentrations. Only AGP influenced imatinib total clearance. Imatinib free concentrations were best predicted using a non-linear binding model to AGP, with a dissociation constant Kd of 319 ng ml(-1) , assuming a 1:1 molar binding ratio. The addition of HSA in the equation did not improve the prediction of imatinib unbound concentrations. CONCLUSION: Although free concentration monitoring is probably more appropriate than total concentrations, it requires an additional ultrafiltration step and sensitive analytical technology, not always available in clinical laboratories. The model proposed might represent a convenient approach to estimate imatinib free concentrations. However, therapeutic ranges for free imatinib concentrations remain to be established before it enters into routine practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: The plasma levels of either brain natriuretic peptide (BNP) or the N-terminal fragment of the prohormone (NT-proBNP) have recently gained extreme importance as markers of myocardial dysfunction. Patients with type 2 diabetes are at high risk of developing cardiovascular complications. This study was aimed to assess whether plasma NT-proBNP levels are at similar levels in type 2 diabetics with or without overt cardiovascular diseases. METHODS: We assayed plasma NT-proBNP in 54 type 2 diabetics, 27 of whom had no overt macro- and/or microvascular complications, while the remaining ones had either or both. The same assay was carried out in 38 healthy control subjects age and sex matched as a group with the diabetics. RESULTS: Plasma NT-proBNP was higher in diabetics (median 121 pg/ml, interquartile range 50-240 pg/ml, ) than in those without complications (37 pg/ml, 21-54 pg/ml, P<0.01). Compared with the controls (55 pg/ml, 40-79 pg/ml), only diabetics with vascular complications had significantly increased plasma NT-proBNP levels (P<0.001). In the diabetics, coronary heart disease and nephropathy (defined according to urinary excretion of albumin) were each independently associated with elevated values of plasma NT-proBNP. CONCLUSIONS: In type 2 diabetes mellitus, patients with macro- and/or micro-vascular complications exhibit an elevation of plasma NT-proBNP levels compared to corresponding patients with no evidence of vascular disease. The excessive secretion of this peptide is independently associated with coronary artery disease and overt nephropathy. The measurement of circulating NT-proBNP concentration may therefore be useful to screen for the presence of macro- and/or microvascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary electrophoresis has drawn considerable attention in the past few years, particularly in the field of chiral separations because of its high separation efficiency. However, its routine use in therapeutic drug monitoring is hampered by its low sensitivity due to a short optical path. We have developed a capillary zone electrophoresis (CZE) method using 2mM of hydroxypropyl-β-cyclodextrin as a chiral selector, which allows base-to-base separation of the enantiomers of mianserin (MIA), desmethylmianserin (DMIA), and 8-hydroxymianserin (OHMIA). Through the use of an on-column sample concentration step after liquid-liquid extraction from plasma and through the presence of an internal standard, the quantitation limits were found to be 5 ng/mL for each enantiomer of MIA and DMIA and 15 ng/mL for each enantiomer of OHMIA. To our knowledge, this is the first published CE method that allows its use for therapeutic monitoring of antidepressants due to its sensitivity down to the low nanogram range. The variability of the assays, as assessed by the coefficients of variation (CV) measured at two concentrations for each substance, ranged from 2 to 14% for the intraday (eight replicates) and from 5 to 14% for the interday (eight replicates) experiments. The deviations from the theoretical concentrations, which represent the accuracy of the method, were all within 12.5%. A linear response was obtained for all compounds within the range of concentrations used for the calibration curves (10-150 ng/mL for each enantiomer of MIA and DMIA and 20-300 ng/mL for each enantiomer of OHMIA). Good correlations were calculated between [(R) + (S)]-MIA and DMIA concentrations measured in plasma samples of 20 patients by a nonchiral gas chromatography method and CZE, and between the (R)- and (S)-concentrations of MIA and DMIA measured in plasma samples of 37 patients by a previously described chiral high-performance liquid chromatography method and CZE. Finally, no interference was noted from more than 20 other psychotropic drugs. Thus, this method, which is both sensitive and selective, can be routinely used for therapeutic monitoring of the enantiomers of MIA and its metabolites. It could be very useful due to the demonstrated interindividual variability of the stereoselective metabolism of MIA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Methadone is a 50:50 mixture of two enantiomers and (R)-methadone accounts for the majority of its opioid effect. The aim of this study was to determine whether a blood concentration of (R)-methadone can be associated with therapeutic response in addict patients in methadone maintenance treatment. Trough plasma concentrations of (R)-, (S)- and (R,S)-methadone were measured in 180 patients in maintenance treatment. Therapeutic response was defined by the absence of illicit opiate or cocaine in urine samples collected during a 2-month period prior to blood sampling. A large interindividual variability of (R)-methadone concentration-to-dose-to-weight ratios was found (mean, S.D., median, range: 112, 54, 100, 19-316 ng x kg/ml x mg). With regard to the consumption of illicit opiate (but not of cocaine), a therapeutic response was associated with (R)- (at 250 ng/ml) and (R,S)-methadone (at 400 ng/ml) but not with (S)-methadone concentrations. A higher specificity was calculated for (R)- than for (R,S)-methadone, as the number of non-responders above this threshold divided by the total number of non-responders was higher for (R,S)-methadone (19%) than for (R)-methadone (7%). The results support the use of therapeutic drug monitoring of (R)-methadone in cases of continued intake of illicit opiates. Due to the variability of methadone concentration-to-dose-to-weight ratios, theoretical doses of racemic methadone could be as small as 55 mg/day and as large as 921 mg/day to produce a plasma (R)-methadone concentration of 250 ng/ml in a 70-kg patient. This demonstrates the importance of individualizing methadone treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the relationships between plasma concentrations of losartan, an orally active angiotensin II inhibitor, its active metabolite EXP3174, and angiotensin II blockade. Six healthy subjects received single oral doses of 40, 80, or 120 mg losartan and placebo at 1-week intervals in a crossover study. Angiotensin II blockade was assessed by the blood pressure response to exogenous angiotensin II before and after losartan administration. EXP3174 reached higher plasma concentrations and was eliminated more slowly than its parent compound; its levels paralleled the profile of angiotensin II blockade closer than losartan. Inhibition of the pressure response was dose dependent. The Hill-shaped relationship between response and EXP3174 concentration (or time-integrated variables) approached a plateau with 80 mg. The dose-dependent increase in plasma renin and angiotensin II exhibited a considerable individual scatter. We conclude that losartan produces a dose-dependent, effective angiotensin II blockade that is largely determined by the active metabolite EXP3174.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractPlants continuously grow during their complete life span and understanding the mechanisms that qualitatively regulate their traits remains a challenging topic in biology. The hormone auxin has been identified as a crucial molecule for shaping plant growth, as it has a role in most developmental processes. In the root, the directional, so-called polar transport of auxin generates a peak of concentration that specifies and maintains the stem cell niche and a subsequent gradient of decreasing concentration that also regulates cell proliferation and differentiation. For these reasons, auxin is considered the main morphogen of the root, as it is fundamental for its organization and maintenance. Recently, in Arabidopsis thaliana, a natural variation screen allowed the discovery of BREVIS RADIX (BRX) gene as a limiting factor for auxin responsive gene expression and thus for root growth.In this study, we discovered that BRX is a direct target of auxin that positively feeds back on auxin signaling, as a transcriptional co-regulator, through interaction with the Auxin Response Factor (ARF) MONOPTEROS (MP), modulating the auxin gene response magnitude during the transition between division and differentiation in the root meristem. Moreover, we provide evidence that BRX is activated at the plasma membrane level as an associated protein before moving into the nucleus to modulate cellular growth.To investigate the discrepancy between the auxin concentration and the expression pattern of its downstream targets, we combined experimental and computational approaches. Expression profiles deviating from the auxin gradient could only be modeled after intersection of auxin activity with the observed differential endocytosis pattern and with positive auto- regulatory feedback through plasma- membrane-to-nucleus transfer of BRX. Because BRX is required for expression of certain auxin response factor targets, our data suggest a cell-type-specific endocytosis-dependent input into transcriptional auxin perception. This input sustains expression of a subset of auxin-responsive genes across the root meristem's division and transition zones and is essential for meristem growth. Thus, the endocytosis pattern provides specific positional information to modulate auxin response. RésuméLes plantes croissent continuellement tout au long de leur cycle de vie. Comprendre et expliquer les mécanismes impliqués dans ce phénomène reste à l'heure actuelle, un défi. L'hormone auxine a été identifiée comme une molécule essentielle à la régulation de la croissance des plantes, car impliquée dans la plupart des processus développementaux. Dans la racine, le transport polaire de l'auxine, par la génération d'un pic de concentration, spécifie et maintient la niche de cellules souches, et par la génération d'un gradient de concentration, contrôle la prolifération et la différentiation cellulaire. Puisque l'auxine est essentielle pour l'organisation et la maintenance du système racinaire, il est considéré comme son principal morphogène. Récemment, dans la plante modèle, Arabidopsis thalinana, un criblage des variations génétique a permis d'identifier le gène Brevis radix (BRX) comme facteur limitant l'expression des gènes de réponse à l'auxine et par là même, la croissance de la racine.Dans ce travail, nous avons découvert que BRX est une cible direct de l'auxine qui rétroactive positivement le signalement de l'hormone, agissant ainsi comme un régulateur transcriptionnel à travers l'interaction avec la protéine Monopteros (MP) de la famille des facteurs de réponse à l'auxine (Auxin Responsive Factor, ARF), et modulant ainsi la magnitude de la réponse des gènes reliés à l'auxine durant la division et la différentiation cellulaire dans le méristème de la racine. De plus, nous fournissons des preuves que BRX est activées au niveau de la membrane plasmique, tel une protéine associée se déplaçant à l'intérieur du noyau et modulant la croissance cellulaire.Pour mener à bien l'investigation des divergences entre la concentration de l'auxine et les schémas d'expression de ses propres gènes cibles, nous avons combiné les approches expérimentales et computationnelles. Les profiles d'expressions déviant du gradient d'auxine pourraient seulement être modéliser après intersection de l'activité de l'auxine avec les schémas différentiels d'endocytose observés et les boucles de rétroaction positives et autorégulatrices par le transfert de BRX de la membrane plasmique au noyau. Puisque BRX est requis pour l'expression de certains gènes cibles des facteurs de réponse à l'auxine, nos données suggèrent une contribution dépendante d'une endocytose spécifique au type de cellule dans la perception transcriptionnelle à l'auxine Cette contribution soutient l'expression d'un sous-set de gène de réponse à l'auxine dans la division du méristème racinaire et la zone de transition, et par conséquent, est essentielle pour la croissance méristematique. Ainsi, le schéma d'endocytose fournit des informations positionnelles spécifiques à la modulation de la réponse à l'auxine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Methylene blue (MB) and light are used for virus inactivation of plasma for transfusion. However, the presence of MB has been the subject of concern, and efforts have been made to efficiently remove the dye after photo-treatment. For this study, plasma was collected by apheresis from 10 donors (group A), then treated using the MacoPharma THERAFLEX procedure (MB; 1 microM, and light exposure; 180 J/cm(2)) (group B), and finally filtered in order to remove the dye (group C). Proteins were analyzed by two-dimensional electrophoresis, and peptides showing modifications were characterized by mass spectrometry. Clottable and antigenic fibrinogen levels, as well as fibrin polymerization time were measured. Analyses of the gels focused on a region corresponding to pI between 4.5 and 6.5, and M(r) from 7000 to 58 000. In this area, 387 +/- 47 spots matched, and four of these spots presented significant modifications. They corresponded to changes of the gamma-chain of fibrinogen, of transthyretin, and of apolipoprotein A-I, respectively. A decrease of clottable fibrinogen and a prolongation of fibrin polymerization time were observed in groups B and C. Removal of MB by filtration was not responsible for additional protein alterations. The effect of over-treatment of plasma by very high concentrations of MB (50 microM) in association with prolonged light exposure (3 h) was also analyzed, and showed complex alterations of most of the plasma proteins, including fibrinogen gamma-chain, transthyretin, and apolipoprotein A-I. Our data indicates that MB treatment at high concentration and prolonged illumination severely injure plasma proteins. By contrast, at the MB concentration used to inactivate viruses, damages are apparently very restricted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, and between high levels and poor tolerability. Monitoring of plasma levels is thus increasingly advised, targeting trough concentrations of 1000 μg/L and above. Objectives: Our study was launched to assess the clinical usefulness of systematic imatinib TDM in CML patients. The present preliminary evaluation questions the appropriateness of dosage adjustment following plasma level measurement to reach the recommended trough level, while allowing an interval of 4-24 h after last drug intake for blood sampling. Methods: Initial blood samples from the first 9 patients in the intervention arm were obtained 4-25 h after last dose. Trough levels in 7 patients were predicted to be significantly away from the target (6 <750 μg/L, and 1 >1500 μg/L with poor tolerance), based on a Bayesian approach using a population pharmacokinetic model. Individual dosage adjustments were taken up in 5 patients, who had a control measurement 1-4 weeks after dosage change. Predicted trough levels were confronted to anterior model-based extrapolations. Results: Before dosage adjustment, observed concentrations extrapolated at trough ranged from 359 to 1832 μg/L (median 710; mean 804, CV 53%) in the 9 patients. After dosage adjustment they were expected to target between 720 and 1090 μg/L (median 878; mean 872, CV 13%). Observed levels of the 5 recheck measurements extrapolated at trough actually ranged from 710 to 1069 μg/L (median 1015; mean 950, CV 16%) and had absolute differences of 21 to 241 μg/L to the model-based predictions (median 175; mean 157, CV 52%). Differences between observed and predicted trough levels were larger when intervals between last drug intake and sampling were very short (~4 h). Conclusion: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to bring trough levels closer to 1000 μg/L (with CV decreasing from 53% to 16%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME study aims to.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Imatinib (Glivec~ has transformed the treatment and prognosis of chronic myeloid leukaemia (CML) and of gastrointestinal stromal tumor (GIST). However, the treatment must be taken indefinitely and is not devoid of inconvenience and toxicity. Moreover, resistance or escape from disease control occurs. Considering the large interindividual differences in the function of the enzymatic and transport systems involved in imatinib disposition, exposure to this drug can be expected to vary widely among patients. Among those known systems is a cytochrome P450 (CYI'3A4) that metabolizes imatinib, the multidrug transporter P-glycoprotein (P-gp; product of the MDR1 gene) that expels imatinib out of cells, and al-acid glycoprotein (AGP), a circulating protein binding imatinib in the plasma. The aim of this observational study was to explore the influence of these covariates on imatinib pharmacokinetics (PK), to assess the interindividual variability of the PK parameters of the drug, and to evaluate whether imatinib use would benefit from a therapeutic drug monitoring (TDM) program. A total of 321 plasma concentrations were measured in 59 patients receiving imatinib, using a validated chromatographic method developed for this study (HPLC-LTV). The results were analyzed by non-linear mixed effect modeling (NONMEM). A one-compartment pharmacokinetic model with first-order absorption appropriately described the data, and a large interindividual variability was observed. The MDK> polymorphism 3435C>T and the CYP3A4 activity appeared to modulate the disposition of imatinib, albeit not significantly. A hyperbolic relationship between plasma AGP levels and oral clearance, as well as volume of distribution, was observed. A mechanistic approach was built up, postulating that only the unbound imatinib concentration was able to undergo first-order elimination. This approach allowed determining an average free clearance (CL,~ of 13101/h and a volume of distribution (Vd) of 301 1. By comparison, the total clearance determined was 141/h (i.e. 233 ml/min). Free clearance was affected by body weight and pathology diagnosis. The estimated variability of imatinib disposition (17% for CLu and 66% for Vd) decreased globally about one half with the model incorporating the AGP impact. Moreover, some associations were observed between PK parameters of the free imatinib concentration and its efficacy and toxicity. Finally, the functional influence of P-gp activity has been demonstrated in vitro in cell cultures. These elements are arguments to further investigate the possible usefulness of a TDM program for imatinib. It may help in individualizing the dosing regimen before overt disease progression or development of treatment toxicity, thus improving both the long-term therapeutic effectiveness and tolerability of this drug. Résumé L'imatinib (Glivec ®) a révolutionné le traitement et le pronostic de la leucémie myéloïde chronique (LMC) et des tumeurs stromales d'origine digestive (GIST). Il s'agit toutefois d'un traitement non dénué d'inconvénients et de toxicité, et qui doit être pris indéfiniment. Par ailleurs, une résistance, ou des échappements au traitement, sont également rencontrés. Le devenir de ce médicament dans l'organisme dépend de systèmes enzymatiques et de transport connus pour présenter de grandes différences interindividuelles, et l'on peut s'attendre à ce que l'exposition à ce médicament varie largement d'un patient à l'autre. Parmi ces systèmes, on note un cytochrome P450 (le CYP3A4) métabolisant l'imatinib, la P-glycoprotéine (P-gp ;codée par le gène MDR1), un transporteur d'efflux expulsant le médicament hors des cellules, et l'atglycoprotéine acide (AAG), une protéine circulante sur laquelle se fixe l'imatinib dans le plasma. L'objectif de la présente étude clinique a été de déterminer l'influence de ces covariats sur la pharmacocinétique (PK) de l'imatinib, d'établir la variabilité interindividuelle des paramètres PK du médicament, et d'évaluer dans quelle mesure l'imatinib pouvait bénéficier d'un programme de suivi thérapeutique (TDM). En utilisant une méthode chromatographique développée et validée à cet effet (HPLC-UV), un total de 321 concentrations plasmatiques a été dosé chez 59 patients recevant de l'imatinib. Les résultats ont été analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle pharmacocinétique à un compartiment avec absorption de premier ordre a permis de décrire les données, et une grande variabilité interindividuelle a été observée. Le polymorphisme du gène MDK1 3435C>T et l'activité du CYP3A4 ont montré une influence, toutefois non significative, sur le devenir de l'imatinib. Une relation hyperbolique entre les taux plasmatiques d'AAG et la clairance, comme le volume de distribution, a été observée. Une approche mécanistique a donc été élaborée, postulant que seule la concentration libre subissait une élimination du premier ordre. Cette approche a permis de déterminer une clairance libre moyenne (CLlibre) de 13101/h et un volume de distribution (Vd) de 301 l. Par comparaison, la clairance totale était de 141/h (c.à.d. 233 ml/min). La CLlibre est affectée par le poids corporel et le type de pathologie. La variabilité interindividuelle estimée pour le devenir de l'imatinib (17% sur CLlibre et 66% sur Vd) diminuait globalement de moitié avec le modèle incorporant l'impact de l'AAG. De plus, une certaine association entre les paramètres PK de la concentration d'imatinib libre et l'efficacité et la toxicité a été observée. Finalement, l'influence fonctionnelle de l'activité de la P-gp a été démontrée in nitro dans des cultures cellulaires. Ces divers éléments constituent des arguments pour étudier davantage l'utilité potentielle d'un programme de TDM appliqué à l'imatinib. Un tel suivi pourrait aider à l'individualisation des régimes posologiques avant la progression manifeste de la maladie ou l'apparition de toxicité, améliorant tant l'efficacité que la tolérabilité de ce médicament. Résumé large public L'imatinib (un médicament commercialisé sous le nom de Glivec ®) a révolutionné le traitement et le pronostic de deux types de cancers, l'un d'origine sanguine (leucémie) et l'autre d'origine digestive. Il s'agit toutefois d'un traitement non dénué d'inconvénients et de toxicité, et qui doit être pris indéfiniment. De plus, des résistances ou des échappements au traitement sont également rencontrés. Le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline appelée pharmacocinétique) dépend de systèmes connus pour présenter de grandes différences entre les individus, et l'on peut s'attendre à ce que l'exposition à ce médicament varie largement d'un patient à l'autre. Parmi ces systèmes, l'un est responsable de la dégradation du médicament dans le foie (métabolisme), l'autre de l'expulsion du médicament hors des cellules cibles, alors que le dernier consiste en une protéine (dénommée AAG) qui transporte l'imatinib dans le sang. L'objectif de notre étude a été de déterminer l'influence de ces différents systèmes sur le comportement pharmacocinétique de l'imatinib chez les patients, et d'étudier dans quelle mesure le devenir de ce médicament dans l'organisme variait d'un patient à l'autre. Enfin, cette étude avait pour but d'évaluer à quel point la surveillance des concentrations d'imatinib présentes dans le sang pourrait améliorer le traitement des patients cancéreux. Une telle surveillance permet en fait de connaître l'exposition effective de l'organisme au médicament (concept abrégé par le terme anglais TDM, pour Therapeutic Drag Monitoring. Ce projet de recherche a d'abord nécessité la mise au point d'une méthode d'analyse pour la mesure des quantités (ou concentrations) d'imatinib présentes dans le sang. Cela nous a permis d'effectuer régulièrement des mesures chez 59 patients. Il nous a ainsi été possible de décrire le devenir du médicament dans le corps à l'aide de modèles mathématiques. Nous avons notamment pu déterminer chez ces patients la vitesse à laquelle l'imatinib est éliminé du sang et l'étendue de sa distribution dans l'organisme. Nous avons également observé chez les patients que les concentrations sanguines d'imatinib étaient très variables d'un individu à l'autre pour une même dose de médicament ingérée. Nous avons pu aussi mettre en évidence que les concentrations de la protéine AAG, sur laquelle l'imatinib se lie dans le sang, avait une grande influence sur la vitesse à laquelle le médicament est éliminé de l'organisme. Ensuite, en tenant compte des concentrations sanguines d'imatinib et de cette protéine, nous avons également pu calculer les quantités de médicament non liées à cette protéine (= libres), qui sont seules susceptibles d'avoir une activité anticancéreuse. Enfin, il a été possible d'établir qu'il existait une certaine relation entre ces concentrations, l'effet thérapeutique et la toxicité du traitement. Tous ces éléments constituent des arguments pour approfondir encore l'étude de l'utilité d'un programme de TDM appliqué à l'imatinib. Comme chaque patient est différent, un tel suivi pourrait aider à l'ajustement des doses du médicament avant la progression manifeste de la maladie ou l'apparition de toxicité, améliorant ainsi tant son efficacité que son innocuité.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Diagnosis of pheochromocytoma (PC) is based on a combination of clinical suspicion, finding an adrenal mass, increased plasma, and urine concentrations of catecholamine metabolites and is finally confirmed with histopathology. In human medicine, it is controversial whether biochemically testing plasma is superior to testing urine. OBJECTIVES: To measure urinary and plasma catecholamines and metanephrines in healthy dogs, dogs with PC, hypercortisolism (HC), and nonadrenal diseases (NAD) and to determine the test with the best diagnostic performance for dogs with PC. ANIMALS: Seven PC dogs, 10 dogs with HC, 14 dogs with NAD, 10 healthy dogs. METHODS: Prospective diagnostic clinical study. Urine and heparin plasma samples were collected and stored at -80°C before analysis using high-pressure liquid chromatography (HPLC) coupled to electrochemical detection or tandem mass spectrometry were performed. Urinary variables were expressed as ratios to urinary creatinine concentration. RESULTS: Dogs with PC had significantly higher urinary normetanephrine and metanephrine : creatinine ratios and significantly higher plasma-total and free normetanephrine and plasma-free metanephrine concentrations compared to the 3 other groups. There were no overlapping results of urinary normetanephrine concentrations between PC and all other groups, and only one PC dog with a plasma normetanephrine concentration in the range of the dogs with HC and NAD disease. Performances of total and free plasma variables were similar. Overlap of epinephrine and norepinephrine results between the groups was large with both urine and plasma. CONCLUSION AND CLINICAL IMPORTANCE: Measurement of normetanephrine is the preferred biochemical test for PC and urine was superior to plasma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Previous studies suggest that arginine vasopressin may have a role in metabolic syndrome (MetS) and diabetes by altering liver glycogenolysis, insulin, and glucagon secretion and pituitary ACTH release. We tested whether plasma copeptin, the stable C-terminal fragment of arginine vasopressin prohormone, was associated with insulin resistance and MetS in a Swiss population-based study. DESIGN AND METHOD: We analyzed data from the population-based Swiss Kidney Project on Genes in Hypertension. Copeptin was assessed by an immunoluminometric assay. Insulin resistance was derived from the HOMA model and calculated as follows: (FPI x FPG)/22.5, where FPI is fasting plasma insulin concentration (mU/L) and FPG fasting plasma glucose (mmol/L). Subjects were classified as having the MetS according to the National Cholesterol Education Program Adult Treatment Panel III criteria. Mixed multivariate linear regression models were built to explore the association of insulin resistance with copeptin. In addition, multivariate logistic regression models were built to explore the association between MetS and copeptin. In the two analyses, adjustment was done for age, gender, center, tobacco and alcohol consumption, socioeconomic status, physical activity, intake of fruits and vegetables and 24 h urine flow rate. Copeptin was log-transformed for the analyses. RESULTS: Among the 1,089 subjects included in this analysis, 47% were male. Mean (SD) age and body mass index were 47.4 (17.6) years 25.0 (4.5) kg/m2. The prevalence of MetS was 10.5%. HOMA-IR was higher in men (median 1.3, IQR 0.7-2.1) than in women (median 1.0, IQR 0.5-1.6,P < 0.0001). Plasma copeptin was higher in men (median 5.2, IQR 3.7-7.8 pmol/L) than in women (median 3.0, IQR 2.2-4.3 pmol/L), P < 0.0001. HOMA-IR was positively associated with log-copeptin after full adjustment (β (95% CI) 0.19 (0.09-0.29), P < 0.001). MetS was not associated with copeptin after full adjustment (P = 0.92). CONCLUSIONS: Insulin resistance, but not MetS, was associated with higher copeptin levels. Further studies should examine whether modifying pharmacologically the arginine vasopressin system might improve insulin resistance, thereby providing insight into the causal nature of this association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proteinuria and hyperphosphatemia are cardiovascular risk factors independent of GFR. We hypothesized that proteinuria induces relative phosphate retention via increased proximal tubule phosphate reabsorption. To test the clinical relevance of this hypothesis, we studied phosphate handling in nephrotic children and patients with CKD. Plasma fibroblast growth factor 23 (FGF-23) concentration, plasma phosphate concentration, and tubular reabsorption of phosphate increased during the proteinuric phase compared with the remission phase in nephrotic children. Cross-sectional analysis of a cohort of 1738 patients with CKD showed that albuminuria≥300 mg/24 hours is predictive of higher phosphate levels, independent of GFR and other confounding factors. Albuminuric patients also displayed higher plasma FGF-23 and parathyroid hormone levels. To understand the molecular mechanisms underlying these observations, we induced glomerular proteinuria in two animal models. Rats with puromycin-aminonucleoside-induced nephrotic proteinuria displayed higher renal protein expression of the sodium-phosphate co-transporter NaPi-IIa, lower renal Klotho protein expression, and decreased phosphorylation of FGF receptor substrate 2α, a major FGF-23 receptor substrate. These findings were confirmed in transgenic mice that develop nephrotic-range proteinuria resulting from podocyte depletion. In vitro, albumin did not directly alter phosphate uptake in cultured proximal tubule OK cells. In conclusion, we show that proteinuria increases plasma phosphate concentration independent of GFR. This effect relies on increased proximal tubule NaPi-IIa expression secondary to decreased FGF-23 biologic activity. Proteinuria induces elevation of both plasma phosphate and FGF-23 concentrations, potentially contributing to cardiovascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extracellular vesicles represent a rich source of novel biomarkers in the diagnosis and prognosis of disease. However, there is currently limited information elucidating the most efficient methods for obtaining high yields of pure exosomes, a subset of extracellular vesicles, from cell culture supernatant and complex biological fluids such as plasma. To this end, we comprehensively characterize a variety of exosome isolation protocols for their efficiency, yield and purity of isolated exosomes. Repeated ultracentrifugation steps can reduce the quality of exosome preparations leading to lower exosome yield. We show that concentration of cell culture conditioned media using ultrafiltration devices results in increased vesicle isolation when compared to traditional ultracentrifugation protocols. However, our data on using conditioned media isolated from the Non-Small-Cell Lung Cancer (NSCLC) SK-MES-1 cell line demonstrates that the choice of concentrating device can greatly impact the yield of isolated exosomes. We find that centrifuge-based concentrating methods are more appropriate than pressure-driven concentrating devices and allow the rapid isolation of exosomes from both NSCLC cell culture conditioned media and complex biological fluids. In fact to date, no protocol detailing exosome isolation utilizing current commercial methods from both cells and patient samples has been described. Utilizing tunable resistive pulse sensing and protein analysis, we provide a comparative analysis of 4 exosome isolation techniques, indicating their efficacy and preparation purity. Our results demonstrate that current precipitation protocols for the isolation of exosomes from cell culture conditioned media and plasma provide the least pure preparations of exosomes, whereas size exclusion isolation is comparable to density gradient purification of exosomes. We have identified current shortcomings in common extracellular vesicle isolation methods and provide a potential standardized method that is effective, reproducible and can be utilized for various starting materials. We believe this method will have extensive application in the growing field of extracellular vesicle research.