143 resultados para Maximal aerobic power


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P < 0.05) relationships occurred between muscle-to-bone ratio and both CMJs height (r ranging from 0.56 to 0.69) as well as with all RSA-related variables (r < -0.53 for sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P < 0.01 and r = 0.55, P < 0.05, respectively) but not with total time (TT, r = 0.44 and 0.33, P > 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to examine the effects of a 5-h hilly run on ankle plantar (PF) and dorsal flexor (DF) force and fatigability. It was hypothesised that DF fatigue/fatigability would be greater than PF fatigue/fatigability. Eight male trail long distance runners (42.5 ± 5.9 years) were tested for ankle PF and DF maximal voluntary isokinetic contraction strength and fatigue resistance tests (percent decrement score), maximal voluntary and electrically evoked isometric contraction strength before and after the run. Maximal EMG root mean square (RMS(max)) and mean power frequency (MPF) values of the tibialis anterior (TA), gastrocnemius lateralis (GL) and soleus (SOL) EMG activity were calculated. The peak torque of the potentiated high- and low-frequency doublets and the ratio of paired stimulation peak torques at 10 Hz over 100 Hz (Db10:100) were analysed for PF. Maximal voluntary isometric contraction strength of PF decreased from pre- to post-run (-17.0 ± 6.2%; P < 0.05), but no significant decrease was evident for DF (-7.9 ± 6.2%). Maximal voluntary isokinetic contraction strength and fatigue resistance remained unchanged for both PF and DF. RMS(max) SOL during maximal voluntary isometric contraction and RMS(max) TA during maximal voluntary isokinetic contraction were decreased (P < 0.05) after the run. For MPF, a significant decrease for TA (P < 0.05) was found and the ratio Db10:100 decreased for PF (-6.5 ± 6.0%; P < 0.05). In conclusion, significant isometric strength loss was only detected for PF after a 5-h hilly run and was partly due to low-frequency fatigue. This study contradicted the hypothesis that neuromuscular alterations due to prolonged hilly running are predominant for DF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twitch mouth pressure (Pmo,tw) during magnetic phrenic nerve stimulation and sniff nasal inspiratory pressure (SNIP) were recently proposed as alternative noninvasive methods for assessing inspiratory muscle strength. This study aimed to compare their reproducibility with maximal inspiratory pressure (MIP) in normal subjects. Ten healthy subjects were studied at functional residual capacity in semirecumbent position. Cervical magnetic phrenic nerve stimulation was performed during gentle expiration against an occlusion incorporating a small leak. Constancy of stimulation was controlled by recording diaphragmatic electromyogram. Within and between-session reproducibility of pressure were studied for Pmo,tw, SNIP, and MIP. The subjects were studied during a session of 10 manoeuvres repeated after 1 day and 1 month. The mean values were 16 cmH2O for Pmo,tw, 118 cmH2O for SNIP, and 115 cmH2O for MIP. For the three tests, the within subject variation was small in relation to between-subject variation, with the intraclass correlation coefficient ranging 0.79-0.90 for Pmo,tw, 0.85-0.92 for SNIP, and 0.88-0.92 for MIP. At 1 day interval, the coefficient of repeatability (2 SD of differences) was 3.6 cmH2O for Pmo,tw, 32 cmH2O for SNIP and 28 cmH2O for MIP. At 1 month interval, the coefficient of repeatability was 5.8 cmH2O for Pmo,tw, 23 cmH2O for SNIP and 21 cmH2O for MIP. We conclude that the within session reproducibility of the new tests twitch mouth pressure and sniff nasal inspiratory pressure is sufficient to be clinically useful. For sniff nasal inspiratory pressure, the between session reproducibility established after 1 day was maintained after 1 month. For twitch mouth pressure, the between session reproducibility declined slightly after 1 month. These characteristics should be considered when using these methods to follow an individual patient over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We characterize the value function of maximizing the total discounted utility of dividend payments for a compound Poisson insurance risk model when strictly positive transaction costs are included, leading to an impulse control problem. We illustrate that well known simple strategies can be optimal in the case of exponential claim amounts. Finally we develop a numerical procedure to deal with general claim amount distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Although the physiological effects of n-3 polyunsaturated fatty acids (n-3PUFA) are generally thought to require several weeks of exposure to allow their incorporation into plasma membranes, intravenous (IV) n-3PUFA attenuate the cardiovascular and neuroendocrine response to stress within 3 h. Whether oral n-3 PUFA exert similar early effects remains unknown. OBJECTIVE: To assess whether acute IV or short term oral n-3PUFA administration reproduces the metabolic effects of long term oral supplements during exercise, and how it relates to their incorporation into platelets and red blood cells (RBC) membranes. DESIGN: Prospective single center open label study in 8 healthy subjects receiving a 3-h infusion of 0.6 g/kg body weight n-3PUFA emulsion, followed one week later by an oral administration of 0.6 g/kg over 3 consecutive days. Maximal power output (cycling exercise), maximal heart rate (HR), blood lactate at exhaustion, and platelet function were measured at baseline and after IV or 3-day oral supplementation; platelet and RBC membrane composition were assessed until 15 days after n-3PUFA administration. RESULTS: Both IV and oral n-3PUFA significantly decreased maximal HR (-6% and -5%), maximal power output (-10%) and peak blood lactate (-47% and -52%) Platelet function tests were unchanged. The EPA and DHA membrane contents of RBC and platelets increased significantly, but only to 1.7-1.9% of fatty acid content. CONCLUSION: The cardiovascular and metabolic effects of n-3 PUFA during exercise occur already within 1-3 days of exposure, and may be unrelated to changes in membranes composition. Effects occur within hours of administration and are unrelated to lipid membrane composition. Trial registered at clinicaltrials.gov as NCT00516178.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We hypothesize that untrained subjects can benefit from a greater cardiovascular stimulation than trained athletes, resembling classical aerobic-type activity, in addition to eliciting strength gains.METHODS: 3 groups of male subjects, inactive (SED), endurance trained (END) and strength trained (STR) underwent fitness (VO2max) and lower-body strength tests (isokinetic). Subjects were submitted to a session of oscillating VT, composed of 3 exercises (isometric half-squat, dynamic squat, dynamic squat with added load), each of 3 minutes duration, and repeated at 3 vibration frequencies (20, 26 and 32 Hz). VO2, heart rate and Borg scale were monitored.RESULTS: 27 healthy subjects (10 SED, 9 END and 8 STR), mean age 24.5 (SED), 25.0 (STR) and 29.8 (END) were included. VO2max was significantly different as expected (47.9 vs. 52.9 vs. 63.9 mL?min-1?kg-1, resp. for SED, STR and END). Isokinetic dominant leg extensors strength was higher in STR (3.32 N?m?kg-1 vs. 2.60 and 2.74 in SED and END). During VT, peak oxygen consumption (% of VO2max) attained was 59.3 in SED, 50.8 in STR and 48.0 in END (P<0.001 between SED and other subjects). Peak heart rate (% of heart rate max) was 82.7 in SED, 80.4 in STR and 72.4 in END. In SED, dynamic exercises without extra load elicited 51.0 % of VO2max and 72.1 % of heart rate max, and perceived effort reached 15.1/20.CONCLUSIONS: VT is an unconventional type of exercise, known to enhance strength, bone density, balance and flexibility. Users are attracted by the relative passivity. In SED, VT elicits sufficient cardiovascular response to benefit overall fitness in addition to the strength effects. VT's higher acceptance as an exercise in sedentary people, compared to jogging or cycling, can lead to better adherence to physical activity. Although long-term effects of VT on health are not available, we believe this type of mixed aerobic and resistance-type exercise can be beneficial on multiple health parameters, especially cardiovascular health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there is consensus that the central nervous system mediates the increases in maximal voluntary force (maximal voluntary contraction, MVC) produced by resistance exercise, the involvement of the primary motor cortex (M1) in these processes remains controversial. We hypothesized that 1-Hz repetitive transcranial magnetic stimulation (rTMS) of M1 during resistance training would diminish strength gains. Forty subjects were divided equally into five groups. Subjects voluntarily (Vol) abducted the first dorsal interosseus (FDI) (5 bouts x 10 repetitions, 10 sessions, 4 wk) at 70-80% MVC. Another group also exercised but in the 1-min-long interbout rest intervals they received rTMS [Vol+rTMS, 1 Hz, FDI motor area, 300 pulses/session, 120% of the resting motor threshold (rMT)]. The third group also exercised and received sham rTMS (Vol+Sham). The fourth group received only rTMS (rTMS_only). The 37.5% and 33.3% gains in MVC in Vol and Vol+Sham groups, respectively, were greater (P = 0.001) than the 18.9% gain in Vol+rTMS, 1.9% in rTMS_only, and 2.6% in unexercised control subjects who received no stimulation. Acutely, within sessions 5 and 10, single-pulse TMS revealed that motor-evoked potential size and recruitment curve slopes were reduced in Vol+rTMS and rTMS_only groups and accumulated to chronic reductions by session 10. There were no changes in rMT, maximum compound action potential amplitude (M(max)), and peripherally evoked twitch forces in the trained FDI and the untrained abductor digiti minimi. Although contributions from spinal sources cannot be excluded, the data suggest that M1 may play a role in mediating neural adaptations to strength training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Exposure to hypoxia leads to several reactions of the organism, which try to compensate the reduced oxygen level in the blood. Acute response is characterized by an increase in pulmonary ventilation (Hypoxia Ventilatory Response, HVR) and in cardiac output (cardiac response to hypoxia). Heart rate (HR) at rest and during exercise is higher at high altitude than at sea level, whereas HRmax is lower. These cardiac adaptations are partially explained by an increased sympathetic stimulation associated with a reduced parasympathetic tone (12). The precise mechanisms of HRmax decline in acute hypoxia are however still to be identified, although several hypothesis have been suggested, such as a direct effect of hypoxia on the electrophysiological properties, an influence of skeletal maximal VO2 or a modulation of the autonomic nervous system (8). Some authors have reported that endurance trained athletes present an increased sensitivity to hypoxia shown by a large reduction in VO2max and an important decrease in arterial saturation. (9,11, 13) A hypoxia test can assess the sensibility of chemoreceptors to the reduction of oxygen by calculating hypoxic ventilatory and cardiac responses, knowing that low sensibility is correlated with poor acclimatization. Two parameters results from the differences in ventilation (and heart rate) divided by the difference in the arterial oxygen saturation between normoxia and hypoxia (18). Objective The hypothesis tested by this study is that parasympathetic reactivation after moderate effort in hypoxic condition can be used as a marker of individual sensibility to hypoxia. Parasympathetic reactivation is a marker of vagal tone that predict endurance capacity and aerobic fitness (2,7). Methods Subjects This study uses data obtained from two groups of athletes participating into two larger studies about adaptation to hypoxia. One group is composed of elite athletes (Swiss ski mountaineering team), the other one of mid-level athletes (ski mountaineering amateurs). The particularity of this target population is that they often train at high altitude, and therefore could show a better response to hypoxia than athleltes of other disciplines. Protocol The athletes performed a submaximal exercise (6min run at 9 km/h, flat) followed by 10 min of seated rest either in an hypoxic chamber (simulated altitude of 3000m) or in normoxic conditions. During the resting phase parasympathetic reactivation was assessed by beat-to-beat HR measurements.A test of tolerance to altitude was also performed. Analysis Parasympathetic reactivation, assessed by the calculation of the root mean square of successive differences in the R-R intervals (RMSSD)(4), is compared to individual responses at altitude, in order to appreciate the correlation between the two phenomena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study assesses differences in adiposity, aerobic fitness, and lifestyle characteristics in preschoolers according to their weight status and sports club (SC) participation. Method: As part of the Ballabeina study, 600 randomly selected preschoolers (mean age 5.1 ± 0.6 years; 50.2% girls) were analyzed. Body composition was measured by bioelectrical impedance, aerobic fitness by the 20-meter shuttle run test, and physical activity by accelerometers. Eating habits, media use, and SC participation were assessed by questionnaires. Results: Overweight children (Swiss national percentiles) and children not participating in SC had both lower aerobic fitness and higher % body fat compared to their respective counterparts (all p ≤ 0.028). In addition, children not participating in SC were less physically active, had more media use, and ate less healthy compared to children participating in SC (all p ≤ 0.023). Controlling for parental sociocultural determinants attenuated differences in % body fat, in physical activity, and in eating habits. Conclusion: Aerobic fitness differs both according to weight status and SC participation in preschoolers. Furthermore, in view of the many differences in lifestyle behaviors, SC participation at this age could represent a more discriminatory indicator of healthy lifestyle characteristics than weight status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This descriptive article illustrates the application of Global Positioning System (GPS) professional receivers in the field of locomotion studies. The technological challenge was to assess the external mechanical work in outdoor walking. METHODS: Five subjects walked five times during 5 min on an athletic track at different imposed stride frequency (from 70-130 steps x min(-1)). A differential GPS system (carrier phase analysis) measured the variation of the position of the trunk at 5 Hz. A portable indirect calorimeter recorded breath-by-breath energy expenditure. RESULTS: For a walking speed of 1.05 +/- 0.11 m x s(-1), the vertical lift of the trunk (43 +/- 14 mm) induced a power of 46.0 +/- 20.4 W. The average speed variation per step (0.15 +/- 0.03 m x s(-1)) produced a kinetic power of 16.9 +/- 7.2 W. As compared with commonly admitted values, the energy exchange (recovery) between the two energy components was low (39.1 +/- 10.0%), which induced an overestimated mechanical power (38.9 +/- 18.3 W or 0.60 W x kg(-1) body mass) and a high net mechanical efficiency (26.9 +/- 5.8%). CONCLUSION: We assumed that the cause of the overestimation was an unwanted oscillation of the GPS antenna. It is concluded that GPS (in phase mode) is now able to record small body movements during human locomotion, and constitutes a promising tool for gait analysis of outdoor unrestrained walking. However, the design of the receiver and the antenna must be adapted to human experiments and a thorough validation study remains to be conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doping with natural steroids can be detected by evaluating the urinary concentrations and ratios of several endogenous steroids. Since these biomarkers of steroid doping are known to present large inter-individual variations, monitoring of individual steroid profiles over time allows switching from population-based towards subject-based reference ranges for improved detection. In an Athlete Biological Passport (ABP), biomarkers data are collated throughout the athlete's sporting career and individual thresholds defined adaptively. For now, this approach has been validated on a limited number of markers of steroid doping, such as the testosterone (T) over epitestosterone (E) ratio to detect T misuse in athletes. Additional markers are required for other endogenous steroids like dihydrotestosterone (DHT) and dehydroepiandrosterone (DHEA). By combining comprehensive steroid profiles composed of 24 steroid concentrations with Bayesian inference techniques for longitudinal profiling, a selection was made for the detection of DHT and DHEA misuse. The biomarkers found were rated according to relative response, parameter stability, discriminative power, and maximal detection time. This analysis revealed DHT/E, DHT/5β-androstane-3α,17β-diol and 5α-androstane-3α,17β-diol/5β-androstane-3α,17β-diol as best biomarkers for DHT administration and DHEA/E, 16α-hydroxydehydroepiandrosterone/E, 7β-hydroxydehydroepiandrosterone/E and 5β-androstane-3α,17β-diol/5α-androstane-3α,17β-diol for DHEA. The selected biomarkers were found suitable for individual referencing. A drastic overall increase in sensitivity was obtained.The use of multiple markers as formalized in an Athlete Steroidal Passport (ASP) can provide firm evidence of doping with endogenous steroids. Copyright © 2010 John Wiley & Sons, Ltd.