304 resultados para Internal resonance
Resumo:
Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.
Resumo:
The PERFORM MRI Project was an ancillary study of the PERFORM trial. Its aim was to investigate the potential effects of terutroban in patients with atherothrombotic disorders, in comparison to aspirin, on the evolution of magnetic resonance imaging (MRI) lesions after a recent ischemic stroke or transient ischemic attack (TIA). The change in both hypointense and hyperintense lesions on the fluid attenuated inversion recovery (FLAIR) sequence, in the total brain volume and in the hippocampal volume from baseline (M1) to the final visit (M24) was assessed as well as the number of emergent microbleeds. A total of 748 patients had their MRI examination validated both at M1 and M24 during the study. At baseline, the volume of hypointense and hyperintense lesions on FLAIR images, the total brain volume, the hippocampal volume and the number of patients with microbleeds did not differ between the two groups. During follow-up, the mean volumetric increase of lesions hypointense or hyperintense on FLAIR images (from 5 to 8 %), the mean reduction of total brain volume (−0.4 %) and of hippocampal volume (−4 %), did not differ between the two treatment arms. The same parameters analysed ipsilateral to the ischaemic lesion did not differ either between the two groups. In the terutroban group, 16.3 % of patients presented with emergent microbleeds, 10.7 % in the aspirin group; this difference was not significant. In the PERFORM study, the progression of FLAIR lesions, of cerebral or hippocampal atrophy and of microbleeds did not differ between patients treated by terutroban and those treated by aspirin.
Resumo:
Using a substituted cysteine accessibility scan, we have investigated the structures that form the internal pore of the acid-sensing ion channel 1a. We have identified the amino acid residues Ala-22, Ile-33, and Phe-34 in the amino terminus and Arg-43 in the first transmembrane helix, which when mutated into cysteine, were modified by intracellular application of MTSET, resulting in channel inhibition. The inhibition of the R43C mutant by internal MTSET requires opening of the channel. In addition, binding of Cd2+ ions to R43C slows the channel inactivation. This indicates that the first transmembrane helix undergoes conformational changes during channel inactivation. The effect of Cd2+ on R43C can be obtained with Cd2+ applied at either the extracellular or the intracellular side, indicating that R43C is located in the channel pore. The block of the A22C, I33C, and F34C mutants by MTSET suggests that these residues in the amino terminus of the channel also participate to the internal pore.
Resumo:
Training new doctors in general internal medicine represents a challenge. This requires to define future needs, which result from interest that are not necessarily convergent between patients, doctors, insurers and politicians. Problems related to medical demography in Switzerland, with the ageing of the population, the increase in health care costs and the place of Switzerland within the European Community require the implementation of specific objectives to train new physicians in general internal medicine. The success of these opportunities depends on social factors, political choices and choices from physician's association. In this article we will approach these challenges by formulating some proposals--nonexhaustive--in order to guarantee sufficient renewal in general internal medicine.
Resumo:
PURPOSE: F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and MRI are used for detecting liver metastases from uveal melanoma. The introduction of new treatment options in clinical trials might benefit from early response assessment. Here, we determine the value of FDG-PET/CT with respect to MRI at diagnosis and its potential for monitoring therapy. MATERIAL AND METHODS: Ten patients with biopsy-proven liver metastases of uveal melanoma enrolled in a randomized phase III trial (NCT00110123) underwent both FDG-PET coupled with unenhanced CT and gadolinium-diethylene triamine pentaacetic acid-enhanced liver MRI within 4 weeks. FDG-PET and MRI were evaluated blindly and then compared using the ratio of lesion to normal liver parenchyma PET-derived standardized uptake value (SUV). The influence of lesion size and response to chemotherapy were studied. RESULTS: Overall, 108 liver lesions were seen: 34 (31%) on both modalities (1-18 lesions/patient), four (4%) by PET/CT only, and 70 (65%) by MRI only. SUV correlated with MRI lesion size (r=0.81, P<0.0001). PET/CT detected 26 of 33 (79%) MRI lesions of more than or equal to 1.2 cm, whereas it detected only eight of 71 (11%) lesions of less than 1.2 cm (P<0.0001). MRI lesions without PET correspondence were small (0.6±0.2 vs. 2.1±1.1 cm, P<0.0001). During follow-up (six patients, 30 lesions), the ratio lesion-to-normal-liver SUV diminished in size-stable lesions (1.90±0.64-1.46±0.50, P<0.0001), whereas it increased in enlarging lesions (1.56±0.40-1.99±0.56, P=0.032). CONCLUSION: MRI outweighs PET/CT for detecting small liver metastases. However, PET/CT detected at least one liver metastasis per patient and changes in FDG uptake not related to size change, suggesting a role in assessing early therapy response.
Resumo:
BACKGROUND: Four different types of internal hernias (IH) are known to occur after laparoscopic Roux-en-Y gastric bypass (LRYGBP) performed for morbid obesity. We evaluate multidetector row helical computed tomography (MDCT) features for their differentiation. METHODS: From a prospectively collected database including 349 patients with LRYGBP, 34 acutely symptomatic patients (28 women, mean age 32.6), operated on for IH immediately after undergoing MDCT, were selected. Surgery confirmed 4 (11.6%) patients with transmesocolic, 10 (29.4%) with Petersen's, 15 (44.2%) with mesojejunal, and 5 (14.8%) with jejunojejunal IH. In consensus, 2 radiologists analyzed 13 MDCT features to distinguish the four types of IH. Statistical significance was calculated (p < 0.05, Fisher's exact test, chi-square test). RESULTS: MDCT features of small bowel obstruction (SBO) (n = 25, 73.5%), volvulus (n = 22, 64.7%), or a cluster of small bowel loops (SBL) (n = 27, 79.4%) were inconsistently present and overlapped between the four IH. The following features allowed for IH differentiation: left upper quadrant clustered small bowel loops (p < 0.0001) and a mesocolic hernial orifice (p = 0.0003) suggested transmesocolic IH. SBL abutting onto the left abdominal wall (p = 0.0021) and left abdominal shift of the superior mesenteric vessels (SMV) (p = 0.0045) suggested Petersen's hernia. The SMV predominantly shifted towards the right anterior abdominal wall in mesojejunal hernia (p = 0.0033). Location of the hernial orifice near the distal anastomosis (p = 0.0431) and jejunojejunal suture widening (p = 0.0005) indicated jejunojejunal hernia. CONCLUSIONS: None of the four IH seems associated with a higher risk of SBO. Certain MDCT features, such as the position of clustered SBL and hernial orifice, help distinguish between the four IH and may permit straightforward surgery.
Resumo:
PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.
Resumo:
Parallel tracks for clinical scientists, basic scientists, and pediatric imagers was the novel approach taken for the highly successful 8th Annual Scientific Sessions of the Society for Cardiovascular Magnetic Resonance, held in San Francisco, California, January 21 to 23, 2005. Attendees were immersed in information on the latest scientific advances in cardiovascular magnetic resonance (CMR) from mice to man and technological advances from systems with field strengths from 0.5 T to 11.7 T. State-of-the-art applications were reviewed, spanning a wide range from molecular imaging to predicting outcome with CMR in large patient populations.
Resumo:
The adaptive function of melanin located in the integument is well known. Although pigments are also deposited in various internal organs, their function is unclear. A review of the literature revealed that 'internal melanin' protects against parasites, pollutants, low temperature, oxidative stress, hypoxemia and UV light, and is involved in the development and function of organs. Importantly, several studies have shown that the amount of melanin deposited on the external body surface is correlated with the amount located inside the body. This finding raises the possibility that internal melanin plays more important physiological roles in dark than light-colored individuals. Internal melanin and coloration may therefore not evolve independently. This further emphasizes the major role played by indirect selection in evolutionary processes.
Resumo:
Instead of standard rigid thoracoscopes, we used a modified gastroscope for video assistance during 12 minimally invasive left internal mammary harvesting. Flexibility and remote control of its last centimeters give to the gastroscope a total freedom of movements, and perfect positioning in every direction. The scope is equipped with cold light, a suction canal and an irrigation canal, which allow for in situ washing without needing to remove it from the thoracic cavity. Thanks to these advantages, vision and lighting are always perfect.
Resumo:
PURPOSE: To determine and compare the diagnostic performance of magnetic resonance imaging (MRI) and computed tomography (CT) for the diagnosis of tumor extent in advanced retinoblastoma, using histopathologic analysis as the reference standard. DESIGN: Systematic review and meta-analysis. PARTICIPANTS: Patients with advanced retinoblastoma who underwent MRI, CT, or both for the detection of tumor extent from published diagnostic accuracy studies. METHODS: Medline and Embase were searched for literature published through April 2013 assessing the diagnostic performance of MRI, CT, or both in detecting intraorbital and extraorbital tumor extension of retinoblastoma. Diagnostic accuracy data were extracted from included studies. Summary estimates were based on a random effects model. Intrastudy and interstudy heterogeneity were analyzed. MAIN OUTCOME MEASURES: Sensitivity and specificity of MRI and CT in detecting tumor extent. RESULTS: Data of the following tumor-extent parameters were extracted: anterior eye segment involvement and ciliary body, optic nerve, choroidal, and (extra)scleral invasion. Articles on MRI reported results of 591 eyes from 14 studies, and articles on CT yielded 257 eyes from 4 studies. The summary estimates with their 95% confidence intervals (CIs) of the diagnostic accuracy of conventional MRI at detecting postlaminar optic nerve, choroidal, and scleral invasion showed sensitivities of 59% (95% CI, 37%-78%), 74% (95% CI, 52%-88%), and 88% (95% CI, 20%-100%), respectively, and specificities of 94% (95% CI, 84%-98%), 72% (95% CI, 31%-94%), and 99% (95% CI, 86%-100%), respectively. Magnetic resonance imaging with a high (versus a low) image quality showed higher diagnostic accuracies for detection of prelaminar optic nerve and choroidal invasion, but these differences were not statistically significant. Studies reporting the diagnostic accuracy of CT did not provide enough data to perform any meta-analyses. CONCLUSIONS: Magnetic resonance imaging is an important diagnostic tool for the detection of local tumor extent in advanced retinoblastoma, although its diagnostic accuracy shows room for improvement, especially with regard to sensitivity. With only a few-mostly old-studies, there is very little evidence on the diagnostic accuracy of CT, and generally these studies show low diagnostic accuracy. Future studies assessing the role of MRI in clinical decision making in terms of prognostic value for advanced retinoblastoma are needed.