101 resultados para Ileal-pouch anastomosis
Resumo:
BACKGROUND: Gastric banding (GB) is one of the most popular bariatric procedures for morbid obesity. Apart from causing weight loss by alimentary restriction, it can interfere with functions of the esophagus and upper stomach. The aim of this study was to evaluate if the results of extensive preoperative upper GI testing were correlated with long-term outcome and complications after GB. METHODS: Using a prospectively maintained computerized database including all the patients undergoing bariatric operations in both our hospitals, we performed a retrospective analysis of the patients who underwent complete upper gastrointestinal (GI) testing (endoscopy, pH monitoring, and manometry) before GB. RESULTS: One hundred thirty-four patients underwent complete testing before GB. Abnormal pH monitoring (increased total reflux time, increased diurnal reflux time, increased number of reflux episodes) predicted the development of complications and especially pouch dilatation and food intolerance. The mean De Meester score was higher among patients who developed complications than in the remaining ones (25.4 vs 17.7, P=0.03). High lower esophageal sphincter pressure also predicted progressive long-term food intolerance. Endoscopic findings were not predictive of the long-term outcome. CONCLUSIONS: There is some association between the function of the upper digestive tract and long-term complications after gastric banding. Abnormal pH monitoring predicts overall long-term complications, especially food intolerance with or without reflux, and pouch dilatation, and a high lower esophageal sphincter pressure predicts long-term food intolerance. Extended upper gastrointestinal testing with endoscopy, 24-h pH monitoring, and esophageal manometry is probably worthwhile in selecting patients for gastric banding.
Resumo:
OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.
Resumo:
Human cytomegalovirus-induced lesions resembling malignancies have been described in the gastrointestinal tract and include ulcerated or exophytic large masses. The aim of this study was to review the cases registered in the databases of two academic hospitals and formulate a hypothesis concerning the pathogenic mechanisms responsible for cytomegalovirus-induced pseudotumor development. All the diagnoses of human cytomegalovirus infections of the upper gastrointestinal tract recorded from 1991 to 2013 were reviewed. Cases of mucosal alterations misdiagnosed endoscopically as malignancies were selected. Large ulcers occurring in the stomach (three cases) and an irregular exophytic mass at the gastro-jejunal anastomosis were misdiagnosed endoscopically as malignancies (4 cases out of 53). Histologically, all lesions reflected hyperplastic mucosal changes with a prevalence of epithelial and stroma infected cells, without signs of cell atypia. The hypothesis presented is that the development of human cytomegalovirus-induced pseudotumors may be the morphological expression of chronic mucosa damage underlying long-term infection.
Resumo:
The in situ saphenous vein bypass has been introduced in our department since 1989. A total of 26 bypasses in 22 patients have been followed prospectively. Indications for revascularisation have been severe arterial insufficiency in 73% of the cases (stage III or IV). With the exception of one postoperative death (myocardial infarction), all the patients have recovered uneventfully, with a regression to stage I. No amputation has been necessary. Morbidity has been 30%, with mainly minor local complications. The primary patency rate is 83% at one year and 78% after 2 and 3 years, whereas the secondary patency rate is 91% at one year, and remains constant thereafter up to 3 years. Considering our results and those from the literature, we believe that the in situ technique is very valuable, especially for below-knee vascular reconstruction. Technical difficulties of the method are analysed.
Resumo:
The treatment of biliary lithiasis has changed during the past 20 years. Cholecystectomy remains the gold standard for cholelithiasis, but many options are available for calculi of the common bile duct. Among them are surgical open or laparoscopic choledochotomy, biliary-enteric anastomosis, transduodenal sphincterotomy (TDS), endoscopic sphincterotomy. With the aim to describe the current place of TDS, we reviewed the patients operated on in our department between 1976 and 1992. We found 78 patients with a mean age of 58 years (26-89 years). 34 (43%) of them had acute cholecystitis, with 26 being operated on urgently. 47 (60%) were jaundiced, 15 (19%) had pancreatitis and 12 (15%) had cholangitis before operation. Indications for TDS have been impacted stone or absence of progression of the contrast medium on intraoperative cholangiography in 71 patients (91%). 3 patients died (1 pulmonary embolism, 1 sepsis of pulmonary origin, 1 MOF syndrome complicating preoperative necrotizing pancreatitis). 30 patients (38%) had complications, of which 20 were directly related to TDS. Hemorrhage occurred in 4 cases, and resolved spontaneously without transfusion. Hyperamylasemia occurred in 17 instances, but clinical pancreatitis developed in only 1 case, with complete resolution. 1 duodenal fistula healed after conservative therapy. No death is attributable directly to TDS. Today, the importance of endoscopic sphincterotomy is increasing. This retrospective study shows that TDS, if performed with caution, does not increase the operative risks even in emergent operations. During surgical exploration of the common bile duct, TDS is indicated to remove an impacted stone, or as a bilio-enteric anastomosis if multiple stones are present with a thin common duct.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
OBJECTIVES: Repair of the right ventricular outflow tract (RVOT) in paediatric cardiac surgery remains challenging due to the high reoperation rate. Intimal hyperplasia and consequent arteriosclerosis is one of the most important limitation factors for graft durability. Since local shear stress and pressure are predictive elements for intimal hyperplasia and wall degeneration, we sought to determine in an oversized 12-mm RVOT model, with computed fluid dynamics simulation, the local haemodynamical factors that may explain intimal hyperplasia. This was done with the aim of identifying the optimal degree of oversizing for a 12-mm native RVOT. METHODS: Twenty domestic pigs, with a weight of 24.6 ± 0.89 kg and a native RVOT diameter of 12 ± 1.7 mm, had valve conduits of 12, 16, 18 and 20 mm implanted. Pressure and flow were measured at 75, 100 and 125% of normal flow at RVOT at the pulmonary artery, pulmonary artery bifurcation and at the left and right pulmonary arteries. Three-dimensional computed fluid dynamics (CFD) simulation in all four geometries in all flow modalities was performed. Local shear stress and pressure conditions were investigated. RESULTS: Corresponding to 75, 100 and 125% of steady-state flow, three inlet velocity profiles were obtained, 0.2, 0.29 and 0.36 m/s, respectively. At inflow velocity profiles, low shear stress areas, ranged from 0 to 2 Pa, combined with high-pressure areas ranging from 11.5 to 12.1 mmHg that were found at distal anastomosis, at bifurcation and at the ostia of the left and right pulmonary arteries in all geometries. CONCLUSIONS: In all three oversized geometries, the local reparation of shear stress and pressure in the 16-mm model showed a similar local profile as in the native 12 mm RVOT. According to these findings, we suggest oversizing the natural 12-mm RVOT by not more than 4 mm. The elements responsible for wall degeneration and intimal hyperplasia remain very similar to the conditions present in native RVOT.
Resumo:
NlmCategory="UNASSIGNED">Crohn's disease (CD) evolution is characterized by increasing proportions of patients developing complications such as strictures, abscesses and fistulas that require surgical management. After resection of a diseased intestinal segment, CD recurrence concerns up to 60% of patients within a year post surgery. The mucosa just above the site of the intestinal anastomosis is at particularly high risk of relapse. Prophylactic medical therapy to prevent recurrence has been shown to be effective with a variety of medications, but the recurrence rate remains high, demanding that a better risk stratification of patients be achieved. Recognized risk factors for postsurgical CD recurrence include young age at diagnosis and at surgery, smoking, need for repeated surgeries and penetrating disease. These patients require full dose immunosuppressive or anti-tumor necrosis factor (anti-TNF) therapy, which should be initiated in the immediate postoperative period, to prevent the onset of an inflammatory activity in the bowel. Systematic follow-up by endoscopy to monitor treatment benefit should also be part of the management, as endoscopic recurrence heralds clinical relapse in these patients. The role of noninvasive markers of mucosal inflammation, such as stool calprotectin levels, show promise to complete this monitoring. Although the efficacy of mesalazine and imidazole antibiotics has been long recognized, more aggressive approaches, such as thiopurines and anti-TNF antibodies, have shown higher efficacies in direct comparison trials. The potential place of anti-homing agents is not yet defined, but these agents should in principle be of interest for this prophylactic indication due to their mode of action and interesting side-effect profile. The current recommendations are based on a step-up approach that includes immunosuppressors and/or imidazole antibiotics, followed by an anti-TNF agent, such as infliximab and adalimumab, both already tested in randomized trials in this indication. When endoscopic recurrence is identified during follow-up, upscaling to anti-TNF or dose escalation is advocated.
Resumo:
AIM: According to the French GRECCAR III randomized trial, full mechanical bowel preparation (MBP) for rectal surgery decreases the rate of postoperative morbidity, in particular postoperative infectious complications, but MBP is not well tolerated by the patient. The aim of the present study was to determine whether a preoperative rectal enema (RE) might be an alternative to MBP. METHODS: An analysis was performed of 96 matched cohort patients undergoing rectal resection with primary anastomosis and protective ileostomy at two different university teaching hospitals, whose rectal cancer management was comparable except for the choice of preoperative bowel preparation (MBP or RE). Prospective databases were retrospectively analysed. RESULTS: Patients were well matched for age, gender, body mass index and Charlson index. The surgical approach and cancer characteristics (level above anal verge, stage and use of neoadjuvant therapy) were comparable between the two groups. Anastomotic leakage occurred in 10% of patients having MBP and in 8% having RE (P = 1.00). Pelvic abscess formation (6% vs 2%, P = 0.63) and wound infection (8% vs 15%, P = 0.55) were also comparable. Extra-abdominal infection (13% vs 13%, P = 1.00) and non-infectious abdominal complications such as ileus and bleeding (27% and 31%, P = 0.83) were not significantly different. Overall morbidity was comparable in the two groups (50% vs 54%, P = 0.83). CONCLUSION: A simple RE before rectal surgery seems not to be associated with more postoperative infectious complications nor a higher overall morbidity than MBP.
Resumo:
We describe a unique case of anorectal malformation (ARM) with a non-terminal colovesical fistula. While some aspects are similar to the congenital pouch colon (CPC), the differences make it a distinct form.
Resumo:
Off-pump coronary bypass grafting may decrease the rate of stroke, due to minimal aortic manipulation. For venous grafts, clampless hemostasis when performing the proximal anastomosis can be achieved using the Heartstring device. We describe a technique using a single device to suture two veins to one aortotomy. This technique requires less space and could be advantageous in very short, small, and calcified aortas. In to our experience, this technique is rapid, simple, easy to reproduce, and cost-saving.
Improving coronary artery bypass graft durability: use of the external saphenous vein graft support.
Resumo:
Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.