148 resultados para GENERALIZED PSEUDOSPECTRAL METHOD
Resumo:
AbstractFor a wide range of environmental, hydrological, and engineering applications there is a fast growing need for high-resolution imaging. In this context, waveform tomographic imaging of crosshole georadar data is a powerful method able to provide images of pertinent electrical properties in near-surface environments with unprecedented spatial resolution. In contrast, conventional ray-based tomographic methods, which consider only a very limited part of the recorded signal (first-arrival traveltimes and maximum first-cycle amplitudes), suffer from inherent limitations in resolution and may prove to be inadequate in complex environments. For a typical crosshole georadar survey the potential improvement in resolution when using waveform-based approaches instead of ray-based approaches is in the range of one order-of- magnitude. Moreover, the spatial resolution of waveform-based inversions is comparable to that of common logging methods. While in exploration seismology waveform tomographic imaging has become well established over the past two decades, it is comparably still underdeveloped in the georadar domain despite corresponding needs. Recently, different groups have presented finite-difference time-domain waveform inversion schemes for crosshole georadar data, which are adaptations and extensions of Tarantola's seminal nonlinear generalized least-squares approach developed for the seismic case. First applications of these new crosshole georadar waveform inversion schemes on synthetic and field data have shown promising results. However, there is little known about the limits and performance of such schemes in complex environments. To this end, the general motivation of my thesis is the evaluation of the robustness and limitations of waveform inversion algorithms for crosshole georadar data in order to apply such schemes to a wide range of real world problems.One crucial issue to making applicable and effective any waveform scheme to real-world crosshole georadar problems is the accurate estimation of the source wavelet, which is unknown in reality. Waveform inversion schemes for crosshole georadar data require forward simulations of the wavefield in order to iteratively solve the inverse problem. Therefore, accurate knowledge of the source wavelet is critically important for successful application of such schemes. Relatively small differences in the estimated source wavelet shape can lead to large differences in the resulting tomograms. In the first part of my thesis, I explore the viability and robustness of a relatively simple iterative deconvolution technique that incorporates the estimation of the source wavelet into the waveform inversion procedure rather than adding additional model parameters into the inversion problem. Extensive tests indicate that this source wavelet estimation technique is simple yet effective, and is able to provide remarkably accurate and robust estimates of the source wavelet in the presence of strong heterogeneity in both the dielectric permittivity and electrical conductivity as well as significant ambient noise in the recorded data. Furthermore, our tests also indicate that the approach is insensitive to the phase characteristics of the starting wavelet, which is not the case when directly incorporating the wavelet estimation into the inverse problem.Another critical issue with crosshole georadar waveform inversion schemes which clearly needs to be investigated is the consequence of the common assumption of frequency- independent electromagnetic constitutive parameters. This is crucial since in reality, these parameters are known to be frequency-dependent and complex and thus recorded georadar data may show significant dispersive behaviour. In particular, in the presence of water, there is a wide body of evidence showing that the dielectric permittivity can be significantly frequency dependent over the GPR frequency range, due to a variety of relaxation processes. The second part of my thesis is therefore dedicated to the evaluation of the reconstruction limits of a non-dispersive crosshole georadar waveform inversion scheme in the presence of varying degrees of dielectric dispersion. I show that the inversion algorithm, combined with the iterative deconvolution-based source wavelet estimation procedure that is partially able to account for the frequency-dependent effects through an "effective" wavelet, performs remarkably well in weakly to moderately dispersive environments and has the ability to provide adequate tomographic reconstructions.
Resumo:
An important statistical development of the last 30 years has been the advance in regression analysis provided by generalized linear models (GLMs) and generalized additive models (GAMs). Here we introduce a series of papers prepared within the framework of an international workshop entitled: Advances in GLMs/GAMs modeling: from species distribution to environmental management, held in Riederalp, Switzerland, 6-11 August 2001.We first discuss some general uses of statistical models in ecology, as well as provide a short review of several key examples of the use of GLMs and GAMs in ecological modeling efforts. We next present an overview of GLMs and GAMs, and discuss some of their related statistics used for predictor selection, model diagnostics, and evaluation. Included is a discussion of several new approaches applicable to GLMs and GAMs, such as ridge regression, an alternative to stepwise selection of predictors, and methods for the identification of interactions by a combined use of regression trees and several other approaches. We close with an overview of the papers and how we feel they advance our understanding of their application to ecological modeling.
Resumo:
PURPOSE: Aerodynamic drag plays an important role in performance for athletes practicing sports that involve high-velocity motions. In giant slalom, the skier is continuously changing his/her body posture, and this affects the energy dissipated in aerodynamic drag. It is therefore important to quantify this energy to understand the dynamic behavior of the skier. The aims of this study were to model the aerodynamic drag of alpine skiers in giant slalom simulated conditions and to apply these models in a field experiment to estimate energy dissipated through aerodynamic drag. METHODS: The aerodynamic characteristics of 15 recreational male and female skiers were measured in a wind tunnel while holding nine different skiing-specific postures. The drag and the frontal area were recorded simultaneously for each posture. Four generalized and two individualized models of the drag coefficient were built, using different sets of parameters. These models were subsequently applied in a field study designed to compare the aerodynamic energy losses between a dynamic and a compact skiing technique. RESULTS: The generalized models estimated aerodynamic drag with an accuracy of between 11.00% and 14.28%, and the individualized models estimated aerodynamic drag with an accuracy between 4.52% and 5.30%. The individualized model used for the field study showed that using a dynamic technique led to 10% more aerodynamic drag energy loss than using a compact technique. DISCUSSION: The individualized models were capable of discriminating different techniques performed by advanced skiers and seemed more accurate than the generalized models. The models presented here offer a simple yet accurate method to estimate the aerodynamic drag acting upon alpine skiers while rapidly moving through the range of positions typical to turning technique.
Resumo:
AIM: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). METHODS: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biomicroscopy was performed at 3 and 12 months. RESULTS: Mean follow-up period was 18.6+/-5.9 (VDSCI) and 18.9+/-3.6 (DSCI) months (P=NS). Mean preoperative IOP was 22.4+/-7.4 mm Hg for VDSCI and 20.4+/-4.4 mm Hg for DSCI eyes (P=NS). Mean postoperative IOP was 3.9+/-2.3 (VDSCI) and 6.3+/-4.3 (DSCI) (P<0.05) at day 1, and 12.2+/-3.9 (VDSCI) and 13.3+/-3.4 (DSCI) (P=NS) at month 24. At the last visit, the complete success rate (defined as an IOP of < or =18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eyes (P=NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9+/-4.2 mm3 (VDSCI) and 6.8+/-7.5 mm3 (DSCI) (P=0.426) and 5.2+/-3.6 mm3 (VDSCI) and 5.4+/-2.9 mm3 (DSCI) (P=0.902) for the intrascleral space. CONCLUSIONS: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
Resumo:
BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
Resumo:
PURPOSE: Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS: Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. RESULTS: The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. CONCLUSION: Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
The trabecular bone score (TBS) is a gray-level textural metric that can be extracted from the two-dimensional lumbar spine dual-energy X-ray absorptiometry (DXA) image. TBS is related to bone microarchitecture and provides skeletal information that is not captured from the standard bone mineral density (BMD) measurement. Based on experimental variograms of the projected DXA image, TBS has the potential to discern differences between DXA scans that show similar BMD measurements. An elevated TBS value correlates with better skeletal microstructure; a low TBS value correlates with weaker skeletal microstructure. Lumbar spine TBS has been evaluated in cross-sectional and longitudinal studies. The following conclusions are based upon publications reviewed in this article: 1) TBS gives lower values in postmenopausal women and in men with previous fragility fractures than their nonfractured counterparts; 2) TBS is complementary to data available by lumbar spine DXA measurements; 3) TBS results are lower in women who have sustained a fragility fracture but in whom DXA does not indicate osteoporosis or even osteopenia; 4) TBS predicts fracture risk as well as lumbar spine BMD measurements in postmenopausal women; 5) efficacious therapies for osteoporosis differ in the extent to which they influence the TBS; 6) TBS is associated with fracture risk in individuals with conditions related to reduced bone mass or bone quality. Based on these data, lumbar spine TBS holds promise as an emerging technology that could well become a valuable clinical tool in the diagnosis of osteoporosis and in fracture risk assessment.
Resumo:
Objectives: The aim of this study was to compare specificity and sensitivity of different biological markers that can be used in a forensic field to identify potentially dangerous drivers because of their alcohol habits. Methods: We studied 280 Swiss drivers after driving while under the alcohol influence. 33 were excluded for not having CDT N results, 247 were included (218 men (88%) and 29 women (12%). Mean age was 42,4 (SD:12, min: 20 max: 76). The evaluation of the alcohol consumption concerned the month before the CDT test and was considered as such after the interview: Heavy drinkers (>3 drinks per day): 60 (32.7%), < 3 drinks per day and moderate: 127 (51.4%) 114 (46.5%), abstinent: 60 (24.3%) 51 (21%). Alcohol intake was monitored by structured interviews, self-reported drinking habits and the C-Audit questionnaire as well as information provided by their family and general practitioner. Consumption was quantified in terms of standard drinks, which contain approximately 10 grams of pure alcohol (Ref. WHO). Results: comparison between moderate (less or equal to 3 drinks per day) and excessive drinkers (more than 3 drinks) Marker ROC area 95% CI cut-off sensitivity specificity CDT TIA 0.852 0.786-0917 2.6* 0.93 LR+1.43 0.35 LR-0.192 CDT N latex 0.875 0.821-0.930 2.5* 0.66 LR+ 6.93 0.90 LR- 0.369 Asialo+disialo-tf 0.881 0.826-0.936 1.2* 0.78 LR+4.07 0.80 LR-0.268 1.7° 0.66 LR+8.9 0.93 LR-0.360 GGT 0.659 0.580-0.737 85* 0.37 LR+2.14 0.83 LR-0.764 * cut-off point suggested by the manufacturer ° cut-off point suggested by our laboratory Conclusion: With the cut-off point established by the manufacturer, CDT TIA performed poorly in term of specificity. N latex CDT and CZE CDT were better, especially if a 1.7 cut-off is used with CZE
Resumo:
PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.
Resumo:
To report the case of a child with short absences and occasional myoclonias since infancy who was first diagnosed with an idiopathic generalized epilepsy, but was documented at follow-up to have a mild phenotype of glucose transporter type 1 deficiency syndrome. Unlike other reported cases of Glut-1 DS and epilepsy, this child had a normal development as well as a normal head growth and neurological examination. Early onset of seizures and later recognized episodes of mild confusion before meals together with persistent atypical EEG features and unexpected learning difficulties led to the diagnosis. Seizure control and neuropsychological improvements were obtained with a ketogenic diet.
Resumo:
Peripheral venous cannulation is the preferred method of inserting central venous silastic catheters in premature infants. The standard techniques are placement of the catheter using a breakaway introducer needle or introduction of the catheter through a cannula. In extremely low birth weight infants (<1000 g) successful cannulation is impeded by the small size of the vessels. After repeated attempts, both procedures can be time-consuming and stressful to the infant. We present a modified insertion technique of the standard 2-French silastic catheter with an increased success rate, thus reducing insertion time, stress to the infant, and costs. The method uses the tip of a 20-gauge cannula as dilator/introducer for the 2-French catheter. This tip is inserted into the vessel with a standard 24-gauge cannula. After successful insertion of the dilator/introducer cannula, the standard 2-French catheter can then be advanced easily.