243 resultados para Fibre comparison
Resumo:
In the context of the investigation of the use of automated fingerprint identification systems (AFIS) for the evaluation of fingerprint evidence, the current study presents investigations into the variability of scores from an AFIS system when fingermarks from a known donor are compared to fingerprints that are not from the same source. The ultimate goal is to propose a model, based on likelihood ratios, which allows the evaluation of mark-to-print comparisons. In particular, this model, through its use of AFIS technology, benefits from the possibility of using a large amount of data, as well as from an already built-in proximity measure, the AFIS score. More precisely, the numerator of the LR is obtained from scores issued from comparisons between impressions from the same source and showing the same minutia configuration. The denominator of the LR is obtained by extracting scores from comparisons of the questioned mark with a database of non-matching sources. This paper focuses solely on the assignment of the denominator of the LR. We refer to it by the generic term of between-finger variability. The issues addressed in this paper in relation to between-finger variability are the required sample size, the influence of the finger number and general pattern, as well as that of the number of minutiae included and their configuration on a given finger. Results show that reliable estimation of between-finger variability is feasible with 10,000 scores. These scores should come from the appropriate finger number/general pattern combination as defined by the mark. Furthermore, strategies of obtaining between-finger variability when these elements cannot be conclusively seen on the mark (and its position with respect to other marks for finger number) have been presented. These results immediately allow case-by-case estimation of the between-finger variability in an operational setting.
Resumo:
Aim This study compares the direct, macroecological approach (MEM) for modelling species richness (SR) with the more recent approach of stacking predictions from individual species distributions (S-SDM). We implemented both approaches on the same dataset and discuss their respective theoretical assumptions, strengths and drawbacks. We also tested how both approaches performed in reproducing observed patterns of SR along an elevational gradient.Location Two study areas in the Alps of Switzerland.Methods We implemented MEM by relating the species counts to environmental predictors with statistical models, assuming a Poisson distribution. S-SDM was implemented by modelling each species distribution individually and then stacking the obtained prediction maps in three different ways - summing binary predictions, summing random draws of binomial trials and summing predicted probabilities - to obtain a final species count.Results The direct MEM approach yields nearly unbiased predictions centred around the observed mean values, but with a lower correlation between predictions and observations, than that achieved by the S-SDM approaches. This method also cannot provide any information on species identity and, thus, community composition. It does, however, accurately reproduce the hump-shaped pattern of SR observed along the elevational gradient. The S-SDM approach summing binary maps can predict individual species and thus communities, but tends to overpredict SR. The two other S-SDM approaches the summed binomial trials based on predicted probabilities and summed predicted probabilities - do not overpredict richness, but they predict many competing end points of assembly or they lose the individual species predictions, respectively. Furthermore, all S-SDM approaches fail to appropriately reproduce the observed hump-shaped patterns of SR along the elevational gradient.Main conclusions Macroecological approach and S-SDM have complementary strengths. We suggest that both could be used in combination to obtain better SR predictions by following the suggestion of constraining S-SDM by MEM predictions.
Resumo:
Purpose:To functionally and morphologically characterize the retina and optic nerve after transplantation of Brain-derived neurotrophic factor (BDNF) and Glial-derived neurotrophic factor (GDNF) secreting mesenchymal stem cells (MSCs) into glaucomatous rat eyes. Methods:Chronic ocular hypertension (COH) was induced in Brown Norway rats. Lentiviral constructs were used to transduce rat MSCs to produce BDNF, GDNF, or green fluorescent protein (GFP). The fellow eyes served as internal controls. Two days following COH induction, eyes received intravitreal injections of transduced MSCs. Electroretinography was performed to assess retinal function. Tonometry was performed throughout the experiment to monitor IOP. 42 days after MSC transplantation, rats were euthanized and the eyes and optic nerves were prepared for analysis. Results:Increased expression and secretion of BDNF and GDNF from lentiviral-transduced MSCs was verified using ELISA, and a bioactivity assay. Ratio metric analysis (COH eye/ Internal control eye response) of the Max combined response A-Wave showed animals with BDNF-MSCs (23.35 ± 5.15%, p=0.021) and GDNF-MSCs (28.73 ± 3.61%, p=0.025) preserved significantly more visual function than GFP-MSC treated eyes MSCs (18.05 ± 5.51%). Animals receiving BDNF-MSCs also had significantly better B-wave (33.80 ± 7.19%) and flicker ERG responses (28.52 ± 10.43%) than GFP-MSC treated animals (14.06 ± 12.67%; 3.52 ± 0.07%, respectively). Animals receiving GDNF-MSC transplants tended to have better function than animals with GFP-MSC transplants, but were not statistically significant (p=0.057 and p=0.0639). Conclusions:Mesenchymal stem cells are an excellent source of cells for autologous transplantation for the treatment of neurodegenerative diseases. We have demonstrated that lentiviral- transduced MSCs can survive following transplantation and preserve visual function in glaucomatous eyes. These results suggest that MSCs may be an ideal cellular vehicle for delivery of specific neurotrophic factors to the retina.
Resumo:
Photons participate in many atomic and molecular interactions and processes. Recent biophysical research has discovered an ultraweak radiation in biological tissues. It is now recognized that plants, animal and human cells emit this very weak biophotonic emission which can be readily measured with a sensitive photomultiplier system. UVA laser induced biophotonic emission of cultured cells was used in this report with the intention to detect biophysical changes between young and adult fibroblasts as well as between fibroblasts and keratinocytes. With suspension densities ranging from 1-8 x 106 cells/ml, it was evident that an increase of the UVA-laser-light induced photon emission intensity could be observed in young as well as adult fibroblastic cells. By the use of this method to determine ultraweak light emission, photons in cell suspensions in low volumes (100 microl) could be detected, in contrast to previous procedures using quantities up to 10 ml. Moreover, the analysis has been further refined by turning off the photomultiplier system electronically during irradiation leading to the first measurements of induced light emission in the cells after less than 10 micros instead of more than 100 milliseconds. These significant changes lead to an improvement factor up to 106 in comparison to classical detection procedures. In addition, different skin cells as fibroblasts and keratinocytes stemming from the same donor were measured using this new highly sensitive method in order to find new biophysical insight of light pathways. This is important in view to develop new strategies in biophotonics especially for use in alternative therapies.
Resumo:
An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.
Resumo:
The importance of direct and indirect alcohol markers to evaluate alcohol consumption in clinical and forensic settings is increasingly recognized. While some markers are used to prove abstinence from ethanol, other markers are suitable for detection of alcohol misuse. Phosphatidyl ethanol (PEth) is ranked among the latter. There is only little information about the correlation between PEth and other currently used markers (ethyl glucuronide, ethyl sulfate, carbohydrate deficient transferrin, gamma-glutamyl transpeptidase, and methanol) and about their decline during detoxification. To get more information, 18 alcohol-dependent patients in withdrawal therapy were monitored for these parameters in blood and urine for up to 19 days. There was no correlation between the different markers. PEth showed a rapid decrease at the beginning of the intervention, a slow decline after the first few days, and could still be detected after 19 days of abstinence from ethanol.
Resumo:
The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.
Resumo:
A questionnaire investigating adolescents' opinions and experiences regarding marijuana use was administered to 163 adolescents and young adults (96 boys and 67 girls) aged 13 to 20 (mean age = 16.8, s.d. = 1.5). Items referred to marijuana and other substances' dangerousness, representations regarding the positive and negative consequences of marijuana use. Responses were compared according to marijuana use status (classified into never/occasional use, current regular use and past regular use). Results show that adolescents' opinions differ according to their experience with marijuana use. Current regular users evaluate marijuana as less dangerous, but alcohol and heroin as more dangerous in comparison with never/occasional and past users. Current and past users are more likely to define marijuana as a medical drug and a plant used in agriculture, and less likely to define it as an illegal drug. Current and past users evaluate marijuana use as a way to cope with stress, to relax to a greater extent than do never/occasional users do. The latter attribute more negative consequences to marijuana use such as diminished driving ability and school performance and a pathway to hard drugs.
Resumo:
OBJECTIVE: To estimate the incremental cost-effectiveness of the first-line pharmacotherapies (nicotine gum, patch, spray, inhaler, and bupropion) for smoking cessation across six Western countries-Canada, France, Spain, Switzerland, the United States, and the United Kingdom. DESIGN AND STUDY POPULATION: A Markov-chain cohort model to simulate two cohorts of smokers: (1) a reference cohort given brief cessation counselling by a general practitioner (GP); (2) a treatment cohort given counselling plus pharmacotherapy. Effectiveness expressed as odds ratios for quitting associated with pharmacotherapies. Costs based on the additional physician time required and retail prices of the medications. INTERVENTIONS: Addition of each first-line pharmacotherapy to GP cessation counselling. MAIN OUTCOME MEASURES: Cost per life-year saved associated with pharmacotherapies. RESULTS: The cost per life-year saved for counselling only ranged from US190 dollars in Spain to 773 dollars in the UK for men, and from 288 dollars in Spain to 1168 dollars in the UK for women. The incremental cost per life-year saved for gum ranged from 2230 dollars for men in Spain to 7643 dollars for women in the US; for patch from 1758 dollars for men in Spain to 5131 dollars for women in the UK; for spray from 1935 dollars for men in Spain to 7969 dollars for women in the US; for inhaler from 3480 dollars for men in Switzerland to 8700 dollars for women in France; and for bupropion from 792 dollars for men in Canada to 2922 dollars for women in the US. In sensitivity analysis, changes in discount rate, treatment effectiveness, and natural quit rate had the strongest influences on cost-effectiveness. CONCLUSIONS: The cost-effectiveness of the pharmacotherapies varied significantly across the six study countries, however, in each case, the results would be considered favourable as compared to other common preventive pharmacotherapies.
Resumo:
This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.
Resumo:
Three different short versions of the NEO-PI-R were compared: The NEO-FFI, the NEO-FFI-R, and a new short version developed in the current study (NEO-60). This new version is intended to improve the psychometric characteristics of the original NEO-FFI, specially in regard to the factor structure at the item-level. A French version of the NEO-PI-R was given to 1090 Swiss subjects, whereas the Spanish (Castilian) version of the NEO-PI-R was administered to 1006 Spanish subjects. Results replicate the limitations of the NEO-FFI already found in other countries. Compared to the NEO-FFI, reliability coefficients and factor structure was enhanced by the NEO-FFI-R and the NEO-60 in both samples, although substantial differences were not found. The factor structure of the NEO-60 shows the best fit since only three items do not load mainly on their own factor in both samples. Besides, correlations between items and NEO-PI-R domain scores are also higher for the items included in the NEO-60 version. On the other hand, convergent correlations with the NEO-PI-R dimensions were satisfactory irrespective of the version, and confirmatory factor analyses show slight differences among the different models generated after the three short versions.
Resumo:
This study compared the Spanish (Castilian) and French versions of the 16PF5 and of the NEO-PI-R in Spanish and Swiss samples. The five-factor solution for the 16PF5 only seems clear for the Castilian version, but not for the French version. Indeed, the congruence coefficients for the Tough-Mindedness and the Self-Control dimensions are low. On the other hand, the five-factor solutions are highly similar for both countries concerning the NEO-PI-R, and the congruence coefficients are above .95 for all five dimensions. The low cross-cultural replicability for the 16PF5 makes it difficult to analyze the differences at the mean level for this inventory. For the NEO-PI-R, the differences are generally very small and globally account for 2.6% of the total variance. Spaniards seem to have slightly lower scores on Actions and slightly higher scores on Dutifulness. These differences could either be due to translation problems, sample selection, or cultural differences.