203 resultados para Evaluation Studies as Topic


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Classically, clinical trials are based on the placebo-control design. Our aim was to analyze the placebo effect in Huntington's disease. METHODS: Placebo data were obtained from an international, longitudinal, placebo-controlled trial for Huntington's disease (European Huntington's Disease Initiative Study Group). One-hundred and eighty patients were evaluated using the Unified Huntington Disease Rating Scale over 36 months. A placebo effect was defined as an improvement of at least 50% over baseline scores in the Unified Huntington Disease Rating Scale, and clinically relevant when at least 10% of the population met it. RESULTS: Only behavior showed a significant placebo effect, and the proportion of the patients with placebo effect ranged from 16% (first visit) to 41% (last visit). Nondepressed patients with better functional status were most likely to be placebo-responders over time. CONCLUSIONS: In Huntington's disease, behavior seems to be more vulnerable to placebo than overall motor function, cognition, and function

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Insight into the function of sleep may be gained by studying animals in the ecological context in which sleep evolved. Until recently, technological constraints prevented electroencephalogram (EEG) studies of animals sleeping in the wild. However, the recent development of a small recorder (Neurologger 2) that animals can carry on their head permitted the first recordings of sleep in nature. To facilitate sleep studies in the field and to improve the welfare of experimental animals, herein, we test the feasibility of using minimally invasive surface and subcutaneous electrodes to record the EEG in barn owls. The EEG and behaviour of four adult owls in captivity and of four chicks in a nest box in the field were recorded. We scored a 24-h period for each adult bird for wakefulness, slow-wave sleep (SWS), and rapid-eye movement (REM) sleep using 4 s epochs. Although the quality and stability of the EEG signals recorded via subcutaneous electrodes were higher when compared to surface electrodes, the owls' state was readily identifiable using either electrode type. On average, the four adult owls spent 13.28 h awake, 9.64 h in SWS, and 1.05 h in REM sleep. We demonstrate that minimally invasive methods can be used to measure EEG-defined wakefulness, SWS, and REM sleep in owls and probably other animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Characterize ethylbenzene and xylene air concentrations, and explore the biological exposure markers (urinary t,t-muconic acid (t,t-MA) and unmetabolized toluene) among petroleum workers offshore. Offshore workers have increased health risks due to simultaneous exposures to several hydrocarbons present in crude oil. We discuss the pooled benzene exposure results from our previous and current studies and possible co-exposure interactions. BTEX air concentrations were measured during three consecutive 12-h work shifts among 10 tank workers, 15 process operators, and 18 controls. Biological samples were collected pre-shift on the first day of study and post-shift on the third day of the study. The geometric mean exposure over the three work shifts were 0.02 ppm benzene, 0.05 ppm toluene, 0.03 ppm ethylbenzene, and 0.06 ppm xylene. Benzene in air was significantly correlated with unmetabolized benzene in blood (r = 0.69, p < 0.001) and urine (r = 0.64, p < 0.001), but not with urinary t,t-MA (r = 0.27, p = 0.20). Toluene in air was highly correlated with the internal dose of toluene in both blood (r = 0.70, p < 0.001) and urine (r = 0.73, p < 0.001). Co-exposures were present; however, an interaction of metabolism was not likely at these low benzene and toluene exposures. Urinary benzene, but not t,t-MA, was a reliable biomarker for benzene at low exposure levels. Urinary toluene was a useful biomarker for toluene exposure. Xylene and ethylbenzene air levels were low. Dermal exposure assessment needs to be performed in future studies among these workers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With some 30,000 dependent persons, opiate addiction constitutes a major public health problem in Switzerland. The Swiss Federal Office of Public Health (FOPH) has long played a leading role in the prevention and treatment of opiate addiction and in research on effective means of containing the epidemic of opiate addiction and its consequences. Major milestones on that path have been the successive "Methadone reports" published by that Office and providing guidance on the care of opiate addiction with substitution treatment. In view of updating the recommendations for the appropriateness of substitution treatment for opiate addiction, in particular for the prescription of methadone, the FOPH commissioned a multi-component project involving the following elements. A survey of current attitudes and practices in Switzerland related to opiate substitution treatment Review of Swiss literature on methadone substitution treatment Review of international literature on methadone substitution treatment National Methadone Substitution Conference Multidisciplinary expert panel to evaluate the appropriateness of substitution treatment. The present report documents the process and summarises the results of the latter element above. The RAND appropriateness method (RAM) was used to distil from literature-based evidence and systematically formulated expert opinion, areas where consensus exist on the appropriateness (or inappropriateness) of methadone maintenance treatment (MMT) and areas where disagreement or uncertainty persist and which should be further pursued. The major areas which were addressed by this report are Initial assessment of candidates for MMT Appropriate settings for initiation of MMT (general and special cases) Appropriateness of methadone supportive therapy Co-treatments and accompanying measures Dosage schedules and pharmacokinetic testing Withdrawal from MMT Miscellaneous questions Appropriateness of other (non-methadone) substitution treatment Summary statements for each of the above categories are derived from the panel meeting and presented in the report. In the "first round", agreement was observed for 31% of the 553 theoretical scenarios evaluated. The "second round" rating, following discussion of divergent ratings, resulted in a much higher agreement among panellists, reaching 53% of the 537 scenarios. Frank disagreement was encountered for 7% of all scenarios. Overall 49% of the clinical situations (scenarios) presented were considered appropriate. The areas where at least 50% of the situations were considered appropriate were "initial assessment of candidates for MMT", the "appropriate settings for initiation of MMT", the "appropriate settings for methadone supportive treatment" and "Appropriateness of other (non-methadone) substitution treatment". The area where there was the least consensus on appropriateness concerned "appropriateness of withdrawal from MMT" (6%). The report discusses the implications and limitations of the panel results and provides recommendations for the dissemination, application, and future use of the criteria for the appropriateness of MMT. The RAND Appropriateness Method proved to be an accepted and appreciated method to assess the appropriateness of methadone maintenance treatment for opiate addicts. In the next step, the results of the expert panel process must now be combined with those of the Swiss and international literature reviews and the survey of current attitudes and practices in Switzerland, to be synthesized into formal practice guidelines. Such guidelines should be disseminated to all concerned, promoted, used and rigorously evaluated for compliance and outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cellular protease subtilisin kexin isozyme-1 (SKI-1)/site-1 protease (S1P) is implicated in the proteolytic processing of the viral envelope glycoprotein precursor (GPC) of arenaviruses, a step strictly required for production of infectious progeny. The small molecule SKI-1/S1P inhibitor PF-429242 was shown to have anti-viral activity against Old World arenaviruses. Here we extended these studies and show that PF-429242 also inhibits GPC processing and productive infection of New World arenaviruses, making PF-429242 a broadly active anti-arenaviral drug. In combination therapy, PF-429242 potentiated the anti-viral activity of ribavirin, indicating a synergism between the two drugs. A hallmark of arenaviruses is their ability to establish persistent infection in vitro and in vivo. Notably, PF-429242 was able to efficiently and rapidly clear persistent infection by arenaviruses. Interruption of drug treatment did not result in re-emergence of infection, indicating that PF-429242 treatment leads to virus extinction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Prospective studies have shown that quantitative ultrasound (QUS) techniques predict the risk of fracture of the proximal femur with similar standardised risk ratios to dual-energy x-ray absorptiometry (DXA). Few studies have investigated these devices for the prediction of vertebral fractures. The Basel Osteoporosis Study (BOS) is a population-based prospective study to assess the performance of QUS devices and DXA in predicting incident vertebral fractures. METHODS: 432 women aged 60-80 years were followed-up for 3 years. Incident vertebral fractures were assessed radiologically. Bone measurements using DXA (spine and hip) and QUS measurements (calcaneus and proximal phalanges) were performed. Measurements were assessed for their value in predicting incident vertebral fractures using logistic regression. RESULTS: QUS measurements at the calcaneus and DXA measurements discriminated between women with and without incident vertebral fracture, (20% height reduction). The relative risks (RRs) for vertebral fracture, adjusted for age, were 2.3 for the Stiffness Index (SI) and 2.8 for the Quantitative Ultrasound Index (QUI) at the calcaneus and 2.0 for bone mineral density at the lumbar spine. The predictive value (AUC (95% CI)) of QUS measurements at the calcaneus remained highly significant (0.70 for SI, 0.72 for the QUI, and 0.67 for DXA at the lumbar spine) even after adjustment for other confounding variables. CONCLUSIONS: QUS of the calcaneus and bone mineral density measurements were shown to be significant predictors of incident vertebral fracture. The RRs for QUS measurements at the calcaneus are of similar magnitude as for DXA measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As part of the ACuteTox project aimed at the development of non-animal testing strategies for predicting human acute oral toxicity, aggregating brain cell cultures (AGGR) were examined for their capability to detect organ-specific toxicity. Previous multicenter evaluations of in vitro cytotoxicity showed that some 20% of the tested chemicals exhibited significantly lower in vitro toxicity as expected from in vivo toxicity data. This was supposed to be due to toxicity at supracellular (organ or system) levels. To examine the capability of AGGR to alert for potential organ-specific toxicants, concentration-response studies were carried out in AGGR for 86 chemicals, taking as endpoints the mRNA expression levels of four selected genes. The lowest observed effect concentration (LOEC) determined for each chemical was compared with the IC20 reported for the 3T3/NRU cytotoxicity assay. A LOEC lower than IC20 by at least a factor of 5 was taken to alert for organ-specific toxicity. The results showed that the frequency of alerts increased with the level of toxicity observed in AGGR. Among the chemicals identified as alert were many compounds known for their organ-specific toxicity. These findings suggest that AGGR are suitable for the detection of organ-specific toxicity and that they could, in conjunction with the 3T3/NRU cytotoxicity assay, improve the predictive capacity of in vitro toxicity testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the feasibility of high-resolution selective three-dimensional (3D) magnetic resonance coronary angiography (MRCA) in the evaluation of coronary artery stenoses. MATERIALS AND METHODS: In 12 patients with coronary artery stenoses, MRCA of the coronary artery groups, including the coronary segments with stenoses of 50% or greater based on conventional x-ray coronary angiography (CAG), was performed with double-oblique imaging planes by orienting the 3D slab along the major axis of each right coronary artery-left circumflex artery (RCA-LCX) group and each left main trunk-left anterior descending artery (LMT-LAD) group. Ten RCA-LCX and five LMT-LAD MR angiograms were obtained, and the results were compared with those of conventional x-ray angiography. RESULTS: Among 70 coronary artery segments expected to be covered, a total of 49 (70%) segments were fully demonstrated in diagnostic quality. The identification of segmental location of stenoses showed as high an accuracy as 96%. The retrospective analysis for stenosis of 50% or greater yielded the sensitivity, specificity, and accuracy of 80%, 85%, and 84%, respectively. CONCLUSION: Selective 3D MRCA has the potential for segment-by-segment evaluation of major portions of the right and left coronary arteries with high accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Extension of retinoblastoma cells anterior to the vitreous surface is a criteria used to categorize retinoblastomas in Group E. In some cases, the assessment of anterior chamber invasion is readily visible by slit lamp examination, but in other cases, invasion of the posterior chamber is clinically difficult to determinate. Ultrasound biomicroscopy (UBM) allows high-resolution images of the anterior segment and structures normally hidden from clinical visualization such as ciliary body, zonule or posterior chamber. This prompted us to evaluate the value of UBM in the assessment of posterior and anterior chamber involvement in patients with peripheral extending retinoblastomas. Methods: We retrospectively reviewed all retinoblastoma cases that underwent enucleation in our institution from 1.1996 till 12.2009 in which UBM ( 35-MHz or 50-MHz) evaluation was available. The UBM results were compared with the histopathological data. Results: From 1.1996 till 12.2009, 146 enucleations were performed in our institution. UBM information was available in 18 cases. There were 8 males and 10 females. The mean age was 4 years old. UBM allowed correct assessement of posterior chamber invasion in 15 cases (13 cases with retinoblastoma in the posterior chamber and 2 cases without retinoblastoma in the posterior chamber). There was a significant correlation between the presence of retinoblastoma cells in the posterior chamber detected by UBM and the histopathological confirmation of posterior chamber involvement (p=0,0008). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity 100%. UBM allowed correct assessment of anterior chamber invasion in 13 cases. The sensitivity of UBM for this purpose was 50% and the specificity 60 %. Conclusions: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the evaluation of the precise extension of the disease. Although our series encompasses only a limited number of cases, the sensitivity and specificity of UBM in the assessment of retinoblastoma anterior extension is interesting. Further prospective multi-centered clinical studies would be necessary to better delineate the utility of this method in the precise categorization of retinoblastoma anterior extension

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Management of patients with atypical squamous cells of undetermined significance (ASCUS) remains controversial. We chose to repeat the Pap smear after four months. If ASCUS persisted in this second test, the patient was advised to undergo colposcopy. Our objective is to determine the clinical significance and the prediction of neoplasia among these patients through a colposcopic examination. METHODS: Of 29,827 patients who had a Pap smear, ASCUS were detected in 1387 (5%) and persisted in the repeat smear of 225 (16%). Colposcopy and an additional Pap smear were performed on 186 patients. RESULTS: Out of 186 colposcopic evaluations, 91 (49%) were normal and the patients had a negative Pap smear. Colposcopy was abnormal in 95/186 patients (51%) (Table 1). Histology of the directed biopsies revealed 38 (21%) low-grade squamous intraepithelial lesions (LSIL) and 17 (9%) high-grade squamous intraepithelial lesions (HSIL). Forty patients (21%) with normal biopsies had ASCUS for the third time in the Pap smear. CONCLUSIONS: Colposcopic evaluation after a repeated Pap smear with ASCUS is an appropriate cost-effective management. Finding 30% of LSIL or HSIL justifies this additional investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to evaluate the direct effect of surgical treatment of subfoveolar neovascular membranes in age related macular degeneration to macular functions. PATIENTS AND METHODS: Thirteen eyes of 13 patients were included in this study. Macular function was assayed by visual acuity and central visual field using the Octopus perimeter before surgery and in the first three post operative months. Pre and post operative fluorescein angiography frames were digitalized and the size of each lesions were compared. RESULTS: After a 3 months follow up, visual acuity remained stable or improved in 66% of the patients. However, visual acuity was better than 0.1 in 15% of the patients. Central visual field comparison disclosed a significant worsening of the retinal sensitivity in the 3 degree field surrounding the central point. On fluorescein frames, submacular scar was 141% of the size of the neovascular membrane. After a mean follow up of 6.9 months (range 3-14), one case of recurrence occurred. A cataract was observed in 85% of the phakic patients followed for more than six months. CONCLUSION: After a short term follow up, surgery can stabilise visual acuity, even though it remains poor. A worsening of the scotoma in the 3 degrees surrounding the central point is observed. However, patients noticed a subjective visual improvement in 62% of the case.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A decline in human sperm quality and quantity has been reported in numerous Western countries. This observation was also accompanied by an increase in urogenital malformations. The need for epidemiological studies dealing with unbiased populations in order to understand the causes of these observations is obvious. In Switzerland, the large majority of young men are asked to attend a military camp to be drafted into the army. A few weeks before this camp, conscripts were contacted and invited to participate in a large national study on semen quality. The participation was totally voluntary and anonymous. From September 2005 to June 2007, 770 volunteers filled out a questionnaire, underwent a clinical examination and provided sperm, blood and urine samples. Using self-rated health assessments, the observed cohort could be considered as healthy and no testicular cancer was found. Moreover, the testicular volumes, measured using Prader's orchidometry and ultrasonography, were comparable to those already published for young male populations. The median sperm concentration was 47 x 10(6)/ml, which is close to the concentration reported in Denmark, known to have the highest incidence of testicular cancer in Europe. Statistically significant differences were observed between regions with a lower sperm concentration for men residing in the Alps (43 x 10(6)/ml) and in the Zurich area (36 x 10(6)/ml) compared to men from West Plateau (54 x 10(6)/ml) and from the Jura (54 x 10(6)/ml). Such a regional discrepancy could be related to environmental factors, including endocrine disruptors. In order to confirm such regional differences more volunteers from the already studied regions should be studied and other parts of the country should be investigated. The rather low sperm concentration of Swiss young volunteers should be considered as a national health issue and investigated further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Many patients with an implantable cardioverter-defibrillator (ICD) have indications for magnetic resonance imaging (MRI). However, MRI is generally contraindicated in ICD patients because of potential risks from hazardous interactions between the MRI and ICD system. OBJECTIVE: The purpose of this study was to use preclinical computer modeling, animal studies, and bench and scanner testing to demonstrate the safety of an ICD system developed for 1.5-T whole-body MRI. METHODS: MRI hazards were assessed and mitigated using multiple approaches: design decisions to increase safety and reliability, modeling and simulation to quantify clinical MRI exposure levels, animal studies to quantify the physiologic effects of MRI exposure, and bench testing to evaluate safety margin. RESULTS: Modeling estimated the incidence of a chronic change in pacing capture threshold >0.5V and 1.0V to be less than 1 in 160,000 and less than 1 in 1,000,000 cases, respectively. Modeling also estimated the incidence of unintended cardiac stimulation to occur in less than 1 in 1,000,000 cases. Animal studies demonstrated no delay in ventricular fibrillation detection and no reduction in ventricular fibrillation amplitude at clinical MRI exposure levels, even with multiple exposures. Bench and scanner testing demonstrated performance and safety against all other MRI-induced hazards. CONCLUSION: A preclinical strategy that includes comprehensive computer modeling, animal studies, and bench and scanner testing predicts that an ICD system developed for the magnetic resonance environment is safe and poses very low risks when exposed to 1.5-T normal operating mode whole-body MRI.