174 resultados para Dental Impression Technique
Resumo:
INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique. METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm. RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85 %). Conversion to an exchange maneuver was necessary in 38/246 (15 %). There were no arterial perforations or ischemic events related to the handling of both microcatheters. CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.
Resumo:
PURPOSE: To objectively characterize different heart tissues from functional and viability images provided by composite-strain-encoding (C-SENC) MRI. MATERIALS AND METHODS: C-SENC is a new MRI technique for simultaneously acquiring cardiac functional and viability images. In this work, an unsupervised multi-stage fuzzy clustering method is proposed to identify different heart tissues in the C-SENC images. The method is based on sequential application of the fuzzy c-means (FCM) and iterative self-organizing data (ISODATA) clustering algorithms. The proposed method is tested on simulated heart images and on images from nine patients with and without myocardial infarction (MI). The resulting clustered images are compared with MRI delayed-enhancement (DE) viability images for determining MI. Also, Bland-Altman analysis is conducted between the two methods. RESULTS: Normal myocardium, infarcted myocardium, and blood are correctly identified using the proposed method. The clustered images correctly identified 90 +/- 4% of the pixels defined as infarct in the DE images. In addition, 89 +/- 5% of the pixels defined as infarct in the clustered images were also defined as infarct in DE images. The Bland-Altman results show no bias between the two methods in identifying MI. CONCLUSION: The proposed technique allows for objectively identifying divergent heart tissues, which would be potentially important for clinical decision-making in patients with MI.
Resumo:
Superior vena cava (SVC) clamping can be required during thoracic surgery for SVC replacement or repair. In such cases, bypass techniques can be necessary to avoid hemodynamic instability, cerebral venous hypertension and hypoperfusion. Here, we report a novel and simple SVC bypass technique which does not require full systemic heparinization, specialized cannulation techniques or pumping devices and which can be applied percutaneously in the preoperative phase or intraoperatively. The preoperative shunt consisted in two Swan-Ganz catheters inserted in the jugular and femoral veins and connected by perfusion tubing with a three way stopcock. The intraoperative shunt consisted of a Pruitt(®)-catheter inserted in the left innominate vein and connected to a femoral Swan-Ganz catheter by perfusion tubing. We validated our system in seven patients undergoing SVC reconstruction. We monitored the systemic arterial blood pressures, the heart rate and vasoactive peptide requirements throughout the procedure. We also determined the neurological status and the in-hospital morbidity and mortality for each patient. Using this bypass, SVC clamping caused no hemodynamic instability, no neurological impairments and no in-hospital complications or deaths. This simple temporary SVC bypass procedure is safe and avoids hemodynamic instability and cerebral venous hypertension.
Resumo:
We have developed a digital holographic microscope (DHM), in a transmission mode, especially dedicated to the quantitative visualization of phase objects such as living cells. The method is based on an original numerical algorithm presented in detail elsewhere [Cuche et al., Appl. Opt. 38, 6994 (1999)]. DHM images of living cells in culture are shown for what is to our knowledge the first time. They represent the distribution of the optical path length over the cell, which has been measured with subwavelength accuracy. These DHM images are compared with those obtained by use of the widely used phase contrast and Nomarski differential interference contrast techniques.
Resumo:
Rats with periodontitis and catheter-induced aortic valve vegetations underwent dental extractions. Cultures of blood obtained 1 min later showed polymicrobial bacteremia in 19 of 19 rats, mostly due to viridans streptococci (18 of 19), Morganella (15 of 19), group G streptococci (13 of 19), and Staphylococcus aureus (10 of 19). Viridans streptococci circulated in higher numbers than did group G streptococci and S. aureus (P less than .01). Three days after dental extractions, 18 of 20 rats had endocarditis. Fifteen (83%) of 18 infections were due to group G streptococci, 9 (50%) of 18 were due to S. aureus, and 2 (11%) of 18 were due to viridans streptococci (P less than .05). In vitro, adherence to platelet-fibrin matrices of endocarditis strain 8 of group G streptococcus was two times greater than that of endocarditis strain S. aureus 23 and three to four times greater than that of Streptococcus sanguis 44 and Morganella morganii 93 (P less than 10(-5)). The inoculum size that produced endocarditis in 90% of rats after iv challenge was 10(5) cfu for group G streptococcus strain 8 and 10(7) for S. sanguis 44.
Resumo:
OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.
Resumo:
BACKGROUND: Chest wall resection and reconstruction can be performed with minimal mortality and excellent functional and cosmetic results using synthetic meshes, methylmethacrylate, or other substitutes. However, these techniques are less easily applicable if chest wall resections have to be performed for infections. METHODS: We report a novel technique for this purpose using a modified latissimus dorsi flap harvested in continuity with the thoracolumbar fascia. The vascularized fascia was sutured into the chest wall defect, providing a stable base for the muscular component of the flap. Three patients requiring large full-thickness resections of the anterolateral chest wall for chronic infections were treated accordingly, two presenting with chronic radionecrosis and osteomyelitis and one with chest wall invasion by pulmonary aspergillosis. RESULTS: There were no intraoperative or postoperative complications and immediate extubation was possible in all 3 patients without the need for postoperative ventilation or tracheotomy. Healing of the infected chest wall was observed in all 3 patients. Postoperative cinemagnetic resonance imaging revealed concordant movements of the replaced segments without evidence of paradoxical motion during inspiration and expiration. CONCLUSIONS: This technique is easy and safe. It allows a stable and satisfactory reconstruction after large anterolateral full-thickness chest wall resections of infected, previously irradiated tissues, using only well-vascularized autologous tissue.
Resumo:
Treatment of symptomatic pharyngeal and esophageal strictures requires endoscopic dilatation. The Savary-Gilliard bougienage was developed by our department and has been used since 1980 for this purpose. We report our experience using this technique. The records of patients seen from January 1, 1963 to December 31, 2005, who had pharyngeal and esophageal strictures needing dilatation, were reviewed. The prevalence of different etiologies, and the incidence of complications using the Savary-Gilliard dilators were assessed. Efficiency of dilatation was assessed over a 17-year segment of this period, using number of dilatations and time intervals between dilatations until resolution of symptoms as outcome measures. Of the 2,652 pharyngeal and esophageal strictures reviewed, 90% were of organic origin (45% benign and 55% malignant stenoses), and 10% were of functional etiology. The most common etiologies were peptic strictures before the era of proton pump inhibitors, and postoperative anastomotic strictures thereafter. A total of 1,862 dilatations using the Savary-Gilliard technique were analyzed. Complication and mortality rates were 0.18 and 0.09% for benign and 4.58 and 0.81% for malignant etiologies, respectively. The number of dilatations per stricture and the time interval between different sessions were dependent on the type of strictures, varying from 1 to 23 dilatations and 7 days to 16 years, respectively. Pharyngeal and esophageal dilatations using the Savary-Gilliard technique were safe when used together with fluoroscopy. Overall, the efficiency of the dilatation procedure was good, but some types of strictures (e.g., caustic, post-surgical and/or post radiotherapy) were refractory to treatment and required repeated dilatations.
Resumo:
OBJECTIVES: A straightforward original Chimney Graft (CG) protocol has been developed at our institution in selected cases of juxtarenal aortic aneurysm (JRAA). The aim of this study was to present our clinical experience of consecutive series with use of uncovered self-expanding stent (SES) as "Open Chimney" (OCh) in the endovascular repair (EVAR) of JRAA. METHODS: A standard endograft with suprarenal fixation struts is delivered with its proximal covered edge just below the highest RA in JRAA presenting the ostium of the two renal arteries at a different aortic level and the distance between the highest renal artery and the beginning of the aneurysm (improved landing zone) ≥10 mm. The low-lying renal artery is maintained patent by the OCh graft (standard SES) delivered from left brachial access (6 Fr). All clinical, anatomical, and operative data were prospectively collected and retrieved for the study analysis. RESULTS: From July 2010 to November 2012, OCh EVAR was offered to 22 consecutive patients considered unfit for JRAA open repair. All procedures were technically successful with aneurysm exclusion and patent OCh graft. One small perioperative type Ia endoleak spontaneously disappeared at the 3-month CT control. One patient died because of acute decompensated heart failure. One patient presented a left hemispheric stroke. The median follow-up of 18 months (range 7-35) showed aneurysm exclusion in all patients without type I and III endoleaks, SES stenosis, and/or renal impairment. CONCLUSIONS: OCh-EVAR is a straightforward technique that can be employed in selected cases of JRAA, avoiding the more complex and expensive fenestrated EVAR.
Resumo:
The success of anatomic repair of Bankart lesion diminishes in the presence of a capsule stretching and/or attenuation is reported in a variable percentage of patients with a chronic gleno-humeral instability. We introduce a new arthroscopic stitch, the MIBA stitch, designed with a twofold aim: to improve tissue grip to reduce the risk of soft tissue tear, particularly cutting through capsular-labral tissue, to and address capsule-labral detachment and capsular attenuation using a double loaded suture anchor. This stitch is a combination of horizontal mattress stitch passing through the capsular-labral complex in a "south-to-north" direction and an overlapping single vertical suture passing through the capsule and labrum in a "east-to-west" direction. The mattress stitch is tied before the vertical stitch in order to reinforce the simple vertical stitch, improving grip and contact force between capsular-labral tissue and glenoid bone.