131 resultados para 3D PIV


Relevância:

20.00% 20.00%

Publicador:

Resumo:

For radiotherapy treatment planning of retinoblastoma inchildhood, Computed Tomography (CT) represents thestandard method for tumor volume delineation, despitesome inherent limitations. CT scan is very useful inproviding information on physical density for dosecalculation and morphological volumetric information butpresents a low sensitivity in assessing the tumorviability. On the other hand, 3D ultrasound (US) allows ahigh accurate definition of the tumor volume thanks toits high spatial resolution but it is not currentlyintegrated in the treatment planning but used only fordiagnosis and follow-up. Our ultimate goal is anautomatic segmentation of gross tumor volume (GTV) in the3D US, the segmentation of the organs at risk (OAR) inthe CT and the registration of both. In this paper, wepresent some preliminary results in this direction. Wepresent 3D active contour-based segmentation of the eyeball and the lens in CT images; the presented approachincorporates the prior knowledge of the anatomy by usinga 3D geometrical eye model. The automated segmentationresults are validated by comparing with manualsegmentations. Then, for the fusion of 3D CT and USimages, we present two approaches: (i) landmark-basedtransformation, and (ii) object-based transformation thatmakes use of eye ball contour information on CT and USimages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In the present study, the impact of the two different fat suppression techniques was investigated for free breathing 3D spiral coronary magnetic resonance angiography (MRA). As the coronary arteries are embedded in epicardial fat and are adjacent to myocardial tissue, magnetization preparation such as T(2)-preparation and fat suppression is essential for coronary discrimination. MATERIALS AND METHODS: Fat-signal suppression in three-dimensional (3D) thin- slab coronary MRA based on a spiral k-space data acquisition can either be achieved by signal pre-saturation using a spectrally selective inversion recovery pre-pulse or by spectral-spatial excitation. In the present study, the performance of the two different approaches was studied in healthy subjects. RESULTS: No significant objective or subjective difference was found between the two fat suppression approaches. CONCLUSION: Spectral pre-saturation seems preferred for coronary MRA applications due to the ease of implementation and the shorter cardiac acquisition window.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A precise classification and an optimal understanding of tibial plateau fractures are the basis of a conservative treatment or adequate surgery. The aim of this prospective study is to determine the contribution of 3D CT to the classification of fractures (comparison with standard X-rays) and as an aid to the surgeon in preoperative planning and surgical reconstruction. Between November 1994 and July 1996, 20 patients presenting 22 tibial plateau fractures were considered in this study. They all underwent surgical treatment. The fractures were classified according to the Müller AO classification. They were all investigated by means of standard X-rays (AP, profile, oblique) and the 3D CT. Analysis of the results has shown the superiority of 3D CT in the planning (easier and more acute), in the classification (more precise), and in the exact assessment of the lesions (quantity of fragments); thereby proving to be of undeniable value of the surgeon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME L'Institut de Géophysique de l'Université de Lausanne a développé au cours de ces dernières années un système d'acquisition de sismique réflexion multitrace à haute résolution 2D et 3D. L'objectif de cette thèse était de poursuivre ce développement tout améliorant les connaissances de la géologie sous le lac Léman, en étudiant en particulier la configuration des grands accidents sous-lacustres dans la Molasse (Tertiaire) qui forme l'essentiel du substratum des formations quaternaires. En configuration 2D, notre système permet d'acquérir des profils sismiques avec une distance inter-CDP de 1,25 m. La couverture varie entre 6 et 18 selon le nombre de traces et la distance inter-tir. Le canon à air (15/15 eu. in.), offre une résolution verticale de 1,25 ni et une pénétration maximale de 300 m sous le fond de l'eau. Nous avons acquis au total plus de 400 km de sections 2D dans le Grand Lac et le Haut Lac entre octobre 2000 et juillet 2004. Une campagne de sismique 3D a fourni des données au large d'Evian sur une surface de 442,5 m sur 1450 m, soit 0,64 km2. La navigation ainsi que le positionnement des hydrophones et de la source ont été réalisés avec des GPS différentiels. Nous avons utilisé un traitement sismique conventionnel, sans appliquer d'AGC et en utilisant une migration post-stack. L'interprétation du substratum antéquaternaire est basée sur l'identification des sismofaciès, sur leurs relations avec les unités géologiques adjacentes au lac, ainsi que sur quelques données de forages. Nous obtenons ainsi une carte des unités géologiques dans le Grand Lac. Nous précisons la position du chevauchement subalpin entre la ville de Lausanne, sur la rive nord, et le bassin de Sciez, sur la rive sud. Dans la Molasse de Plateau, nous avons identifié les décrochements de Pontarlier et de St. Cergue ainsi que plusieurs failles non reconnues jusqu'ici. Nous avons cartographié les accidents qui affectent la Molasse subalpine ainsi que le plan de chevauchement du flysch sur la Molasse près de la rive sud du lac. Une nouvelle carte tectonique de la région lémanique a ainsi pu être dressée. L'analyse du substratum ne montre pas de failles suggérant une origine tectonique de la cuvette lémanique. Par contre, nous suggérons que la forme du creusement glaciaire, donc de la forme du lac Léman, a été influencée par la présence de failles dans le substratum antéquaternaire. L'analyse des sédiments quaternaires nous a permis de tracer des cartes des différentes interfaces ou unités qui les composent. La carte du toit du substratum antéquaternaire montre la présence de chenaux d'origine glaciaire dont la profondeur maximale atteint la cote -200 ni. Leur pente est dirigée vers le nord-est, à l'inverse du sens d'écoulement actuel des eaux. Nous expliquons cette observation par l'existence de circulations sous-glaciaires d'eau artésienne. Les sédiments glaciaires dont l'épaisseur maximale atteint 150 ni au centre du lac ont enregistré les différentes récurrences glaciaires. Dans la zone d'Evian, nous mettons en évidence la présence de lentilles de sédiments glaciolacustres perchées sur le flanc de la cuvette lémanique. Nous avons corrélé ces unités avec des données de forage et concluons qu'il s'agit du complexe inférieur de la pile sédimentaire d'Evian. Celui-ci, âgé de plus de 30 000 ans, serait un dépôt de Kame associé à un lac périglaciaire. La sismique réflexion 3D permet de préciser l'orientation de l'alimentation en matériel détritique de l'unité. La finesse des images obtenues nous permet également d'établir quels types d'érosion ont affecté certaines unités. Les sédiments lacustres, dont l'épaisseur maximale imagée atteint plus de 225 m et sans doute 400 ni sous le delta du Rhône, indiquent plusieurs mécanismes de dépôts. A la base, une mégaturbidite, épaisse d'une trentaine de mètres en moyenne, s'étend entre l'embouchure de la Dranse et le delta du Rhône. Au-dessus, la décantation des particules en suspension d'origine biologique et détritique fournit l'essentiel des sédiments. Dans la partie orientale du lac, les apports détritiques du Rhône forment un delta qui prograde vers l'ouest en s'imbriquant avec les sédiments déposés par décantation. La structure superficielle du delta a brutalement évolué, probablement à la suite de l'évènement catastrophique du Tauredunum (563 A.D.). Sa trace probable se marque par la présence d'une surface érosive que nous avons cartographiée. Le delta a ensuite changé de géométrie, avec notamment un déplacement des chenaux sous-lacustres. Sur l'ensemble de nos sections sismiques, nous n'observons aucune faille dans les sédiments quaternaires qui attesterait d'une tectonique postglaciaire du substratum. ABSTRACT During the last few years the institute of Geophysics of the University of Lausanne cleveloped a 2D and 3D high-resolution multichannel seismic reflection acquisition system. The objective of the present work was to carry on this development white improving our knowledge of the geology under Lake Geneva, in particular by studying the configuration of the large accidents affecting the Tertiary Molasse that makes up the basement of most Quaternary deposits. In its 2D configuration, our system makes it possible to acquire seismic profiles with a CDP interval of 1.25 m. The fold varies from 6 to 18 depending on the number of traces and the shooting interval. Our air gun (15/15 cu. in.) provides a vertical resolution of 1.25 m and a maximum penetration depth of approximately 300 m under water bottom. We acquired more than 400 km of 2D sections in the Grand Lac and the Haut Lac between October 2000 and July 2004. A 3D seismic survey off the city of Evian provided data on a surface of 442.5 m x 1450 m (0.64 km2). Ship's navigation as well as hydrophone- and source positioning were carried out with differential GPS. The seismic data were processed following a conventional sequence without .applying AGC and using post-stack migration. The interpretation of the pre-Quaternary substratum is based on sismofacies, on their relationships with terrestrial geological units and on some borehole data. We thus obtained a map of the geological units in the Grand Lac. We defined the location of the subalpine thrust from Lausanne, on the north shore, to the Sciez Basin, on the south shore. Within the Molasse de Plateau, we identified the already know Pontarlier and St Cergue transforms Fault as well as faults. We mapped faults that affect subalpine Molasse as well as the thrust fault plane between alpine flysch and Molasse near the lake's south shore. A new tectonic map of the Lake Geneva region could thus be drawn up. The substratum does not show faults indicating a tectonic origin for the Lake Geneva Basin. However, we suggest that the orientation of glacial erosion, and thus the shape of Lake Geneva, vas influenced by the presence of faults in the pre-Quaternary basement. The analysis of Quaternary sediments enabled us to draw up maps of various discontinuities or internal units. The top pre-Quaternary basement map shows channels of glacial origin, the deepest of them reaching an altitude of 200 m a.s.l. The channel's slopes are directed to the North-East, in opposite direction of the present water flow. We explain this observation by the presence of artesian subglacial water circulation. Glacial sediments, the maximum thickness of which reaches 150 m in the central part of the lake, record several glacial recurrences. In the Evian area, we found lenses of glacio-lacustrine sediments set high up on the flank of the Lake Geneva Bassin. We correlated these units with on-land borehole data and concluded that they represent the lower complex of the Evian sedimentary pile. The lower complex is aider than 30 000 years, and it could be a Kame deposit associated with a periglacial lake. Our 3D seismic reflexion survey enables us to specify the supply direction of detrital material in this unit. With detailed seismic images we established how some units were affected by different erosion types. The lacustrine sediments we imaged in Lake Geneva are thicker than 225 m and 400 m or more Linder the Rhone Delta. They indicate several depositional mechanisms. Their base is a major turbidite, thirty meters thick on average, that spreads between the Dranse mouth and the Rhone delta. Above this unit, settling of suspended biological and detrital particles provides most of the sediments. In the eastern part of the lake, detrital contribution from the Rhone builds a delta that progrades to the west and imbricates with the settling sediments. The shallow structure of the Rhone delta abruptly evolved, probably after the catastrophic Tauredunum event (563 A.D.). It probably coincides with an erosive surface that we mapped. As a result, the delta geometry changed, in particular associated with a displacement of water bottom channels. In all our seismic sections, we do not observe fault in the Quaternary sediments that would attest postglacial tectonic activity in the basement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to use the plantar pressure insole for estimating the three-dimensional ground reaction force (GRF) as well as the frictional torque (T(F)) during walking. Eleven subjects, six healthy and five patients with ankle disease participated in the study while wearing pressure insoles during several walking trials on a force-plate. The plantar pressure distribution was analyzed and 10 principal components of 24 regional pressure values with the stance time percentage (STP) were considered for GRF and T(F) estimation. Both linear and non-linear approximators were used for estimating the GRF and T(F) based on two learning strategies using intra-subject and inter-subjects data. The RMS error and the correlation coefficient between the approximators and the actual patterns obtained from force-plate were calculated. Our results showed better performance for non-linear approximation especially when the STP was considered as input. The least errors were observed for vertical force (4%) and anterior-posterior force (7.3%), while the medial-lateral force (11.3%) and frictional torque (14.7%) had higher errors. The result obtained for the patients showed higher error; nevertheless, when the data of the same patient were used for learning, the results were improved and in general slight differences with healthy subjects were observed. In conclusion, this study showed that ambulatory pressure insole with data normalization, an optimal choice of inputs and a well-trained nonlinear mapping function can estimate efficiently the three-dimensional ground reaction force and frictional torque in consecutive gait cycle without requiring a force-plate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several molecular therapies require the implantation of cells that secrete biotherapeutic molecules and imaging the location and microenvironment of the cellular implant to ascertain its function. We demonstrate noninvasive in vivo magnetic resonance imaging (MRI) of self-assembled microcontainers that are capable of cell encapsulation. Negative contrast was obtained to discern the microcontainer with MRI; positive contrast was obtained in the complete absence of background signal. MRI on a clinical scanner highlights the translational nature of this research. The microcontainers were loaded with cells that were dispersed in an extracellular matrix, and implanted both subcutaneously and in human tumor xenografts in SCID mice. MRI was performed on the implants, and microcontainers retrieved postimplantation showed cell viability both within and proximal to the implant. The microcontainers are characterized by their small size, three dimensionality, controlled porosity, ease of parallel fabrication, chemical and mechanical stability, and noninvasive traceability in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While 3D thin-slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k-space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k-space gradient-echo and spiral k-space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T(2) preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R-R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) (both P < 0.001) and image quality. The single spiral per R-R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6-fold increase in SNR. The double-interleaf spiral approach showed a 50% reduction in scanning time, a 1.8-fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be "traded" for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The noise power spectrum (NPS) is the reference metric for understanding the noise content in computed tomography (CT) images. To evaluate the noise properties of clinical multidetector (MDCT) scanners, local 2D and 3D NPSs were computed for different acquisition reconstruction parameters.A 64- and a 128-MDCT scanners were employed. Measurements were performed on a water phantom in axial and helical acquisition modes. CT dose index was identical for both installations. Influence of parameters such as the pitch, the reconstruction filter (soft, standard and bone) and the reconstruction algorithm (filtered-back projection (FBP), adaptive statistical iterative reconstruction (ASIR)) were investigated. Images were also reconstructed in the coronal plane using a reformat process. Then 2D and 3D NPS methods were computed.In axial acquisition mode, the 2D axial NPS showed an important magnitude variation as a function of the z-direction when measured at the phantom center. In helical mode, a directional dependency with lobular shape was observed while the magnitude of the NPS was kept constant. Important effects of the reconstruction filter, pitch and reconstruction algorithm were observed on 3D NPS results for both MDCTs. With ASIR, a reduction of the NPS magnitude and a shift of the NPS peak to the low frequency range were visible. 2D coronal NPS obtained from the reformat images was impacted by the interpolation when compared to 2D coronal NPS obtained from 3D measurements.The noise properties of volume measured in last generation MDCTs was studied using local 3D NPS metric. However, impact of the non-stationarity noise effect may need further investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Quantification of daily upper-limb activity is a key determinant in evaluation of shoulder surgery. For a number of shoulder diseases, problem in performing daily activities have been expressed in terms of upper-limb usage and non-usage. Many instruments measure upper-limb movement but do not focus on the differentiations between the use of left or right shoulder. Several methods have been used to measure it using only accelerometers, pressure sensors or video-based analysis. However, there is no standard or widely used objective measure for upper-limb movement. We report here on an objective method to measure the movement of upper-limb and we examined the use of 3D accelerometers and 3D gyroscopes for that purpose. Methods. We studied 8 subjects with unilateral pathological shoulder (8 rotator cuff disease: 53 years old ± 8) and compared them to 18 control subjects (10 right handed, 8 left handed: 32 years old ± 8, younger than the patient group to be almost sure they don_t have any unrecognized shoulder pathology). The Simple Shoulder Test (SST) and Disabilities of the Arm and Shoulder Score (DASH) questionnaires were completed by each subject. Two modules with 3 miniature capacitive gyroscopes and 3 miniature accelerometers were fixed by a patch on the dorsal side of the distal humerus, and one module with 3 gyroscopes and 3 accelerometers were fixed on the thorax. The subject wore the system during one day (8 hours), at home or wherever he/she went. We used a technique based on the 3D acceleration and the 3D angular velocities from the modules attached on the humerus. Results. As expected, we observed that for the stand and sit postures the right side is more used than the left side for a healthy right-handed person(idem on the left side for a healthy left-handed person). Subjects used their dominant upper-limb 18% more than the non-dominant upper-limb. The measurements on patients in daily life have shown that the patient has used more his non affected and non dominant side during daily activity if the dominant side = affected shoulder. If the dominant side affected shoulder, the difference can be showed only during walking period. Discussion-Conclusion. The technique developed and used allowed the quantification of the difference between dominant and non dominant side, affected and unaffected upper-limb activity. These results were encouraging for future evaluation of patients with shoulder injuries, before and after surgery. The feasibility and patient acceptability of the method using body fixed sensors for ambulatory evaluation of upper limbs kinematics was shown.