154 resultados para tiroxina total
Resumo:
Rheumatoid arthritis is an autoimmune disease that may affect multiple joints, both small and large, and leads to numerous complications. The standard surgical treatment for a rheumatoid arthritic ankle has been an arthrodesis. The ideal candidate for an ankle replacement in a rheumatoid patient is one who is moderately active, has a well-aligned ankle and heel, and a fair range of motion in the ankle joint. Good surgical technique and correction of any hindfoot deformity will result in satisfactory alignment of the ankle with regard to the mechanical axis, and this will lead to increased prosthetic longevity.
Resumo:
Infection of total hip arthroplasties (THA) leads to significant long-termmorbidity and high healthcare costs. We evaluated the differentreasons for treatment failure using different surgical modalities in a12-year prosthetic joint infection cohort study.Method: All patients hospitalized at our institution with infected THAwere included either retrospectively (1999-2007) or prospectively(2008-2010). THA infection was defined as growth of the same microorganismin ≥2 tissue or synovial fluid culture, visible purulence, sinustract or acute inflammation on tissue histopathology. Outcome analysiswas performed at outpatient visits, followed by contacting patients,their relatives and/or treating physicians afterwards.Results: During the study period, 117 patients with THA were identified.We exclude 2 patients due to missing data. The median age was69 years (range, 33-102 years); 42% were women. THA was mainlyperformed for osteoarthritis (n = 84), followed by trauma (n = 22),necrosis (n = 4), dysplasia (n = 2), rheumatoid arthritis (n = 1), osteosarcoma(n = 1) and tuberculosis (n = 1). 28 infections occurred early(≤3 months), 25 delayed (3-24 months) and 63 late (≥24 months aftersurgery). Infected THA were treated with (i) two-stage exchange in59 patients (51%, cure rate: 93%), (ii) one-stage exchange in 5 (4.3%,cure rate: 100%), (iii) debridement with change of mobile parts in18 (17%, cure rate: 83%), (iv) debridement without change of mobileparts in 17 (14%, cure rate: 53% ), (v) Girdlestone in 13 (11%, curerate: 100%), and (vi) two-stage exchange followed by removal in 3(2.6%). Patients were followed for a mean of 3.9 years (range, 0.1 to 9years), 7 patients died unrelated to the infected THA. 15 patients (13%)needed additional operations, 1 for mechanical reasons (dislocationof spacer) and 14 for persistent infection: 11 treated with debridementand retention (8 without change and 3 with change of mobile parts)and 3 with two-stage exchange. The mean number of surgery was 2.2(range, 1 to 5). The infection was finally eradicated in all patients, butthe functional outcome remained unsatisfactory in 20% (persistentpain or impaired mobility due to spacer or Girdlestone situation).Conclusions: Non-respect of current treatment concept leads totreatment failure with subsequent operations. Precise analysis of eachtreatment failures can be used for improving the treatment algorithmleading to better results.
Resumo:
During episodes of trauma carnitine-free total parenteral nutrition (TPN) may result in a reduction of the total body carnitine pool, leading to a diminished rate of fat oxidation. Sixteen patients undergoing esophagectomy were equally and randomly divided and received isonitrogenous (0.2 gN/kg.day) and isocaloric (35 kcal/kg.day TPN over 11 days without and with L-carnitine supplementation (12 mg/kg.day). Compared with healthy controls, the total body carnitine pool was significantly reduced in both groups prior to the operation. Without supplementation carnitine concentrations were maintained, while daily provision of carnitine resulted in an elevation of total carnitine mainly due to an increase of the free fraction. Without supplementation the cumulative urinary carnitine losses were 11.5 +/- 6.3 mmol corresponding to 15.5% +/- 8.5% of the estimated total body carnitine pool. Patients receiving carnitine revealed a positive carnitine balance in the immediate postoperative phase, 11.1% +/- 19.0% of the infused carnitine being retained. After 11 days of treatment comparable values for respiratory quotient, plasma triglycerides, free fatty acids, ketone bodies, and cumulative nitrogen balance were observed. It is concluded that in the patient population studied here carnitine supplementation during postoperative TPN did not improve fat oxidation or nitrogen balance.
Resumo:
BACKGROUND: The association between smoking and total energy expenditure (TEE) is still controversial. We examined this association in a multi-country study where TEE was measured in a subset of participants by the doubly labeled water (DLW) method, the gold standard for this measurement. METHODS: This study includes 236 participants from five different African origin populations who underwent DLW measurements and had complete data on the main covariates of interest. Self-reported smoking status was categorized as either light (<7 cig/day) or high (≥7 cig/day). Lean body mass was assessed by deuterium dilution and physical activity (PA) by accelerometry. RESULTS: The prevalence of smoking was 55% in men and 16% in women with a median of 6.5 cigarettes/day. There was a trend toward lower BMI in smokers than non-smokers (not statistically significant). TEE was strongly correlated with fat-free mass (men: 0.70; women: 0.79) and with body weight (0.59 in both sexes). Using linear regression and adjusting for body weight, study site, age, PA, alcohol intake and occupation, TEE was larger in high smokers than in never smokers among men (difference of 298 kcal/day, p = 0.045) but not among women (162 kcal/day, p = 0.170). The association became slightly weaker in men (254 kcal/day, p = 0.058) and disappeared in women (-76 kcal/day, p = 0.380) when adjusting for fat-free mass instead of body weight. CONCLUSION: There was an association between smoking and TEE among men. However, the lack of an association among women, which may be partly related to the small number of smoking women, also suggests a role of unaccounted confounding factors.
Resumo:
PURPOSE: Continuous positive airway pressure (CPAP) is the gold standard treatment for obstructive sleep apnea. However, the physiologic impact of CPAP on cerebral blood flow (CBF) is not well established. Ultrasound can be used to estimate CBF, but there is no widespread accepted protocol. We studied the physiologic influence of CPAP on CBF using a method integrating arterial diameter and flow velocity (FV) measurements obtained for each vessel supplying blood to the brain. METHODS: FV and lumen diameter of the left and right internal carotid, vertebral, and middle cerebral arteries were measured using duplex Doppler ultrasound with and without CPAP at 15 cm H(2)O, applied in a random order. Transcutaneous carbon dioxide (PtcCO(2)), heart rate (HR), blood pressure (BP), and oxygen saturation were monitored. Results were compared with a theoretical prediction of CBF change based on the effect of partial pressure of carbon dioxide on CBF. RESULTS: Data were obtained from 23 healthy volunteers (mean ± SD; 12 male, age 25.1 ± 2.6 years, body mass index 21.8 ± 2.0 kg/m(2)). The mean experimental and theoretical CBF decrease under CPAP was 12.5 % (p < 0.001) and 11.9 % (p < 0.001), respectively. The difference between experimental and theoretical CBF reduction was not statistically significant (3.84 ± 79 ml/min, p = 0.40). There was a significant reduction in PtcCO(2) with CPAP (p = <0.001) and a significant increase in mean BP (p = 0.0017). No significant change was observed in SaO(2) (p = 0.21) and HR (p = 0.62). CONCLUSION: Duplex Doppler ultrasound measurements of arterial diameter and FV allow for a noninvasive bedside estimation of CBF. CPAP at 15 cm H(2)O significantly decreased CBF in healthy awake volunteers. This effect appeared to be mediated predominately through the hypocapnic vasoconstriction coinciding with PCO(2) level reduction. The results suggest that CPAP should be used cautiously in patients with unstable cerebral hemodynamics.
Resumo:
Introduction: The aim of this study is to compare the walking activity of a cohort of individuals before and after total ankle arthroplasty (TAA). Methods: Nineteen consecutive patients (ten males and nine females) with mean age of 58.72, selected for TAA between January and June 2006, were prospectively reviewed with the use of a dedicated ambulatory activity-monitoring device to assess their natural ambulatory activity. Patients were tested in the community for two weeks duration, one month prior to and at least eighteen months after surgery. The ambulatory parameters were assessed through measurement of the number of steps at different cadence, and the time spent walking at different walking paces. Data were analyzed by using specific statistical methods. Results: This study revealed a significant improvement in the number of steps walked at normal cadence (b = 331.63, p = .00) and significantly reduced at low cadence (b = -402.52, p = .00) and medium cadence (b = -386.29, p = .00), before and after TAA. However, there are no significant different between two phases of assessment in term of time spent walking. Conclusion: These quantitative data allow a clear comparative assessment of walking ability following TAR and demonstrates that this intervention improves patient's walking pace.
Resumo:
The aim of the present study was to investigate the effects of continuous and acute L-carnitine supplementation of total parenteral nutrition (TPN) on protein and fat oxidation in severe catabolism. A critically ill and severely malnourished male patient received TPN (non protein energy = 41 kcal/kg/day, provided equally as fat and glucose) over 38 days, without L-carnitine for 23 days and with carnitine supplements (15 mg/kg/day) for the following 15 days. Subsequently, he was given carnitine-free enteral nutrition for 60 more days. A four-hour infusion of 100 mg L-carnitine was given on day 11 of each TPN period. Indirect calorimetry was carried out after 11 days of either carnitine-free or supplemented TPN and at the initiation of enteral nutrition. Additional measurements were performed 4 hours and 24 hours after the acute infusions of carnitine. The rate of protein oxidation and the respiratory quotient were found to be higher, and the rate of fat oxidation to be lower, with carnitine-supplemented TPN, than with either carnitine-free TPN or enteral nutrition. Acute infusion of carnitine resulted in an increased rate of protein oxidation and a reduced rate of fat oxidation on both TPN-regimens. These unfavourable effects on protein metabolism may be due to an impairment of fat oxidation by excess amounts of carnitine.
Resumo:
OBJECTIVE: To assess the prevalence of cardiovascular (CV) risk factors in Seychelles, a middle-income African country, and compare the cost-effectiveness of single-risk-factor management (treating individuals with arterial blood pressure >/= 140/90 mmHg and/or total serum cholesterol >/= 6.2 mmol/l) with that of management based on total CV risk (treating individuals with a total CV risk >/= 10% or >/= 20%).METHODS: CV risk factor prevalence and a CV risk prediction chart for Africa were used to estimate the 10-year risk of suffering a fatal or non-fatal CV event among individuals aged 40-64 years. These figures were used to compare single-risk-factor management with total risk management in terms of the number of people requiring treatment to avert one CV event and the number of events potentially averted over 10 years. Treatment for patients with high total CV risk (>/= 20%) was assumed to consist of a fixed-dose combination of several drugs (polypill). Cost analyses were limited to medication.FINDINGS: A total CV risk of >/= 10% and >/= 20% was found among 10.8% and 5.1% of individuals, respectively. With single-risk-factor management, 60% of adults would need to be treated and 157 cardiovascular events per 100 000 population would be averted per year, as opposed to 5% of adults and 92 events with total CV risk management. Management based on high total CV risk optimizes the balance between the number requiring treatment and the number of CV events averted.CONCLUSION: Total CV risk management is much more cost-effective than single-risk-factor management. These findings are relevant for all countries, but especially for those economically and demographically similar to Seychelles.
Resumo:
BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.
Resumo:
The loss of presynaptic markers is thought to represent a strong pathologic correlate of cognitive decline in Alzheimer's disease (AD). Spinophilin is a postsynaptic marker mainly located to the heads of dendritic spines. We assessed total numbers of spinophilin-immunoreactive puncta. in the CA I and CA3 fields of hippocampus and area 9 in 18 elderly individuals with various degrees of cognitive decline. The decrease in spinophilin-immunoreactivity was significantly related to both Braak neurofibrillary tangle (NFT) staging and clinical severity but not A beta deposition staging. The total number of spinophilin-immunoreactive puncta in CA I field and area 9 were significantly related to MMSE scores and predicted 23.5 and 61.9% of its variability. The relationship between total number of spinophilin-immunoreactive puncta in CA I field and MMSE scores did not persist when adjusting for Braak NFT staging. In contrast, the total number of spinophilin-immunoreactive puncta in area 9 was still significantly related to the cognitive outcome explaining an extra 9.6% of MMSE and 25.6% of the Clinical Dementia Rating scores variability. Our data suggest that neocortical dendritic spine loss is an independent parameter to consider in AD clinicopathologic correlations.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.